• 제목/요약/키워드: Low Voltage Electrical Installation

검색결과 291건 처리시간 0.028초

Asymmetry Effects on Optical Duobinary Transmitters

  • Lee, Dong-Soo;Huh, Hyun-Gue
    • 조명전기설비학회논문지
    • /
    • 제22권3호
    • /
    • pp.1-7
    • /
    • 2008
  • We have theoretically investigated the asymmetry effects on 10[Gb/s] optical duobinary transmitters from the viewpoint of the driving voltage ratios by computer simulations. For driving voltage ratios(=driving voltage/switching voltage) with smaller than 100[%], the transmission performance has been greatly affected by the asymmetry of the bandwidth of LPFs than that of the Mach-Zehnder Modulator driving voltage. On the other hand, for driving voltage ratios with 100[%], the transmission performance has been degraded by the asymmetry of the driving voltage and is not sensitive to that of the bandwidth of LPFs. For the transmission performance within 1[dB] power penalty under the asymmetry condition, the driving voltage ratio with 100[%] has performed better than the low driving voltage ratios.

전압강하를 고려한 저압간선의 설계 알고리즘 (Algorithm for the Low-Voltage Feeder Design in Consideration of Voltage Drop)

  • 고영곤;최홍규;조계술
    • 조명전기설비학회논문지
    • /
    • 제16권3호
    • /
    • pp.84-92
    • /
    • 2002
  • 저압간선의 굵기는 계통의 전압강하, 간선의 포설조건별 온도 보정계수를 적용한 허용 전류 및 간션의 임피 던스 값에 따라 결정된다. 따라서, 간선의 허용전류 값올 결정하기 위하여 간선의 포셜조건에 따른 적정 보정계 수가 적용되어야 하며, 저압간선의 정확한 임피던스 값을 분석하기 위하여 간선의 종류, 간선의 규격, 포셜조건 에 따른 온도, 표피효과 및 근접 효과 둥이 고려되어야 한다. 본 연구는 저압계통의 전압강하를 고려한 간선의 굵기 산정에 대한 체계적인 설계 흐름도를 제시 하였으며, 일반적인 계산 방식에 비하여 오차가 적은 계수로서 저압간선 굵기 선정 설계 실무에 적용할 수 있는 계산 방식을 연구하였다.

낮은 스위칭 주파수로 구동되는 유도전동기의 모델예측토크제어 (MPTC of Induction Motor Driven with Low Switching Frequency)

  • 최유현;한정호;송중호
    • 조명전기설비학회논문지
    • /
    • 제29권3호
    • /
    • pp.61-68
    • /
    • 2015
  • When medium and large induction motors are driven by 2-level inverters with low switching frequency, induction motors provoke deteriorated performances resulted from large torque ripples, flux ripples, and large current distortion. Model predictive torque control(MPTC) for a fast torque control of induction motors is also suffered from large torque ripples when the induction motors are fed by 2-level inverters that are based on 6 active voltage vectors with low switching frequency restricted. To solve this problem, this paper proposes a new MPTC method based on both a 12 active voltage vector and an optimized duty ratio calculation. The proposed control strategy illustrates its effectiveness under the various operating conditions through simulation works.

특별저전압 직류 전원회로에 유용한 서지방호장치의 설계와 특성 (Design and Behavior of Validating Surge Protective Devices in Extra-low Voltage DC Power Lines)

  • 심서현;이복희
    • 조명전기설비학회논문지
    • /
    • 제29권3호
    • /
    • pp.81-87
    • /
    • 2015
  • In order to effectively protect electrical and electronic circuits which are extremely susceptible to lightning surges, multi-stage surge protection circuits are required. This paper presents the operational characteristics of the two-stage hybrid surge protection circuit in extra-low voltage DC power lines. The hybrid surge protective device consists of the gas discharge tube, transient voltage suppressor, and series inductor. The response characteristics of the proposed hybrid surge protective device to combination waves were investigated. As a result, the proposed two-stage surge protective device to combination wave provides the tight clamping level of less than 50V. The firing of the gas discharge tube to lightning surges depends on the de-coupling inductance and the rate-of-change of the current flowing through the transient voltage suppressor. The coordination between the upstream and downstream components of the hybrid surge protective device was satisfactorily achieved. The inductance of a de-coupler in surge protective circuits for low-voltage DC power lines, relative to a resistance, is sufficiently effective. The voltage drop and power loss due to the proposed surge protective device are ignored during normal operation of the systems.

저압회로에서의 TVS와 Varistor의 ESD 방지특성 비교 (The comparison of ESD prevention characteristic of TVS with a Varistor at low voltage)

  • 최홍규;송영주;이완윤
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2002년도 학술대회논문집
    • /
    • pp.105-109
    • /
    • 2002
  • A TVS and Varistor are preservative equipment against electro static discharge(ESD). We use a TVS for I/O protection of a circuit which has faster response time than a Varistor. And a Varistor has large power capability, therefore, which be used in input stage for internal pressure prevention. This paper will compare a TVS with a Varistor with respect to response characteristic to ESD in DC 24[V] low voltage circuit.

  • PDF

30AF 차단기 순시 Trip 동작 특성분석을 통한 저압차단기의 안전성 개선방안 (A Safety Improvement of Low Voltage Circuit-breakers through Analysis of Instantaneous Trip Characteristics of 30AF Circuit-Breakers)

  • 김주철;임정균;이상중
    • 조명전기설비학회논문지
    • /
    • 제24권12호
    • /
    • pp.78-83
    • /
    • 2010
  • The domestic 30AFs that are currently being produced show many problems due to different instantaneous trip characteristics in case of short-circuit. The troubles may cause explosion by excessive short-circuit capacities and arc emission, which results in a wide range of blackout. The function and safety of the low voltage circuit breakers installed before the end load are very important. This paper presents an idea on the safety improvement of the low voltage circuit-breakers through the analysis of instantaneous trip characteristics of domestic 30AF circuit-breakers.

원격 통제형 UPS 개발 (Development of High Performance & Remote controlled UPS)

  • 이왕하;박가우;이진희;김덕규
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2002년도 학술대회논문집
    • /
    • pp.369-374
    • /
    • 2002
  • This paper presented the development trend of UPS and SPS system has focused on large scale system and more convenient system to maintenance and management. In this paper, we proposed low price and high performance SPSs which can de voltage regulation, harmonic reduction, and capable capacity extension in power. These SPSs are composed by two SPSs in their functional structure, one is power control part including voltage regulation and instant voltage compensaton. The others part is web based monitoring and trend management part for more convenient to SPS operator.

  • PDF

Investigation of Interplay between Driving Voltage of MZ Modulators and Bandwidth of Low-pass Filters in Duobinary Modulation Formats

  • Lee, Dong-Soo
    • 조명전기설비학회논문지
    • /
    • 제20권9호
    • /
    • pp.11-17
    • /
    • 2006
  • We have theoretically investigated the effects of the interplay between the driving voltage of Mach-Zehnder(MZ) modulators and the bandwidth of low-pass filters(LPF) in 10[Gb/s] duobinary modulation systems. For the change of driving voltage ratios(driving voltage/switching voltage), the transmission performance has been evaluated over 200[km] of single-mode fiber(SMF) systems. For driving voltage ratios with smaller than 100[%], the transmission performance has been maintained and greatly affected by the bandwidth of LPFs than the driving voltage. For driving voltage ratios with larger than 100[%], the transmission performance has been degraded and is not sensitive to the bandwidth of LPFs. To see the limitation of driving voltage, we have reduced the driving voltage ratio to 50[%]. Our results suggest that 10[Gb/s] duobinary signals with driving voltage ratio with smaller than 100[%] have been transmitted over 200[km] SMF within 2[dB] power penalty without dispersion compensation. For the driving voltage ratio with 50[%], we have verified that the transmission performance was maintained.

국내.외 저압지중함 감전사고사례 및 점검결과의 분석 (Analysis of Electric Shock Accidents and Check Results in Domestic and Foreign low-Voltage Handhole)

  • 김종민;한운기;방선배;김한상;심건보
    • 조명전기설비학회논문지
    • /
    • 제22권1호
    • /
    • pp.124-131
    • /
    • 2008
  • 최근 도심지의 미관을 중요시함에 따라 전력설비의 지중화가 활발히 추진되고 있다. 지중선로의 분기나 접속을 인한 저압 지중함은 주로 사람의 통행이 빈번한 보도나 이면도로에 설치되어 있으며, 지중함 내 누전이 발생할 경우 행인이 감전될 위험이 있다. 더욱이 최근 기상이변으로 인한 폭우로 도로 침수가 자주 발생하고 있으며, 이러한 경우 인체는 물에 젓은 상태이므로 감전에 치명적일 수 있다. 본 논문에서는 저압 지중함에서 발생한 국내 외 감전사고사례의 원인과 점검결과를 분석하였으며, 분석결과 국내 외 감전사고의 사고원인은 통일하나 저압 지중함의 환경조건은 다른 것으로 나타났다. 향후 분석 자료는 저압 지중함에서의 감전사고를 방지하는데 활용필 수 있으며, 저압 지중함의 설치개선을 위한 기초 자료로 이용될 수 있을 것이다.