• Title/Summary/Keyword: Low Vibration

Search Result 2,166, Processing Time 0.039 seconds

Design and Fabrication of an LPVT Embedded in a GIS Spacer (GIS 스페이서 내장형 저전력 측정용 변압기의 설계 및 제작)

  • Seung-Gwan Park;Gyeong-Yeol Lee;Nam-Hoon Kim;Cheol-Hwan Kim;Gyung-Suk Kil
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.37 no.2
    • /
    • pp.175-181
    • /
    • 2024
  • In electrical power substations, bulky iron-core potential transformers (PTs) are installed in a tank of gas-insulated switchgear (GIS) to measure system voltages. This paper proposed a low-power voltage transformer (LPVT) that can replace the conventional iron-core PTs in response to the demand for the digitalization of substations. The prototype LPVT consists of a capacitive voltage divider (CVD) which is embedded in a spacer and an impedance matching circuit using passive components. The CVD was fabricated with a flexible PCB to acquire enough insulation performance and withstand vibration and shock during operation. The performance of the LPVT was evaluated at 80%, 100%, and 120% of the rated voltage (38.1 kV) according to IEC 61869-11. An accuracy correction algorithm based on LabVIEW was applied to correct the voltage ratio and phase error. The corrected voltage ratio and phase error were +0.134% and +0.079 min., respectively, which satisfies the accuracy CL 0.2. In addition, the voltage ratio of LPVT was analyzed in ranges of -40~+40℃, and a temperature correction coefficient was applied to maintain the accuracy CL 0.2. By applying the LPVT proposed in this paper to the same rating GIS, it can be reduced the length per GIS bay by 11%, and the amount of SF6 by 5~7%.

High-rate Single-Frequency Precise Point Positioning (SF-PPP) in the detection of structural displacements and ground motions

  • Mert Bezcioglu;Cemal Ozer Yigit;Ahmet Anil Dindar;Ahmed El-Mowafy;Kan Wang
    • Structural Engineering and Mechanics
    • /
    • v.89 no.6
    • /
    • pp.589-599
    • /
    • 2024
  • This study presents the usability of the high-rate single-frequency Precise Point Positioning (SF-PPP) technique based on 20 Hz Global Positioning Systems (GPS)-only observations in detecting dynamic motions. SF-PPP solutions were obtained from post-mission and real-time GNSS corrections. These include the International GNSS Service (IGS)-Final, IGS real-time (RT), real-time MADOCA (Multi-GNSS Advanced Demonstration tool for Orbit and Clock Analysis), and real-time products from the Australian/New Zealand satellite-based augmentation systems (SBAS, known as SouthPAN). SF-PPP results were compared with LVDT (Linear Variable Differential Transformer) sensor and single-frequency relative positioning (SF-RP) solutions. The findings show that the SF-PPP technique successfully detects the harmonic motions, and the real-time products-based PPP solutions were as accurate as the final post-mission products. In the frequency domain, all GNSS-based methods evaluated in this contribution correctly detect the dominant frequency of short-term harmonic oscillations, while the differences in the amplitude values corresponding to the peak frequency do not exceed 1.1 mm. However, evaluations in the time domain show that SF-PPP needs high-pass filtering to detect accurate displacement since SF-PPP solutions include trends and low-frequency fluctuations, mainly due to atmospheric effects. Findings obtained in the time domain indicate that final, real-time, and MADOCA-based PPP results capture short-term dynamic behaviors with an accuracy ranging from 3.4 mm to 8.5 mm, and SBAS-based PPP solutions have several times higher RMSE values compared to other methods. However, after high-pass filtering, the accuracies obtained from PPP methods decreased to a few mm. The outcomes demonstrate the potential of the high-rate SF-PPP method to reliably monitor structural and earthquake-induced ground motions and vibration frequencies of structures.

Development of a Finger Tactile Stimulator Based on E-Prime Software (E-Prime에 기반한 손가락 촉각 자극기의 개발)

  • Kim, Hyung-Sik;Min, Yoon-Ki;Kim, Bo-Seong;Min, Byung-Chan;Yang, Jae-Woong;Lee, Su-Jeong;Choi, Mi-Hyun;Yi, Jeong-Han;Tack, Gye-Rae;Lee, Bong-Soo;Jun, Jae-Hoon;Chung, Soon-Cheol
    • Science of Emotion and Sensibility
    • /
    • v.13 no.4
    • /
    • pp.703-710
    • /
    • 2010
  • In this study, a tactile stimulator was developed to resolve some problems from the previous version of the system such as system configuration, inappropriate stimulation control and additional problems. The developed tactile stimulator consists of control unit, drive unit and vibrator unit. The control unit was controlled by E-Prime software to generate appropriate vibration pulses. The drive unit supplies enough energy to the vibrator to generate effective stimulation pulses. The vibrator unit consists of small coin type vibrator and velcro, and was made to be attached at the hand easily. The developed tactile stimulator was designed by small-size, light-weight, low-power, simple-fabrication, max 35 channels and little delay time from instruction signal of E-Prime software to vibrator. The duration and magnitude of stimulation was controlled by 10 grades and the problems concerning stimulation control were compensated by wideband frequency ranges. Additionally, the electrical safety was ensured by low voltage operation. Vibrator was made to be attached on finger as well as on any part of the subject. Since this tactile stimulator is developed based on E-Prime software which is widely used in cognitive science, it is believed that this stimulator be suitable for the wide application of cognitive science study.

  • PDF

The Study on the Relationship Between the Duration of Chest Vibration prior to Endotracheal Suctioning and the Changes in Oxygen Saturation in Low-Birth-Weight Infants (저체중아에 있어 기관내 흡인전 흉부진동법의 기관과 산소포화 변화간의 관계 연구)

  • Ahn, Young-Mee
    • Journal of Korean Academy of Nursing
    • /
    • v.25 no.3
    • /
    • pp.597-607
    • /
    • 1995
  • 1960년대 이후 인공호흡기(mechanical ventilator)의 보급과 최근 의료과학의 발달, 간호의 질적 향상의 결과로 저체중출생아를 포함한 고위험 신생아의 생존율이 높아져왔다. 호흡장애증후군(RDS)은 일차적으로 폐포의 완전한 확장을 위해 필요한 계면활성물질(surfactant)의 부족, 미발달된 심폐기능에 의한 병리적 현상으로 저체중아의 가장 큰 원인이 되어왔다. RDS로 인해 인공호흡기에 의존해 있는 저체중아의 경우 적절한 산소공급과 이를 위한 호흡의 유지는 치료의 가장 큰 핵심이 되며, 이를 위한 기관내 흑은 비인두 흡인 (nasopharyngeal suction)은 신생아 중환자실(NICU)의 가장 중요한 간호행위가 되어왔다. 인공호흡기를 위한 기관삽관은 그 자체가 기도의 성모운동을 방해하고 기침반사를 억제시켜 폐 분비물의 효과적 배출을 억제하며, 특히 저체중아의 경우 조산과 관련하여 미발달된 흥곽운등과 심폐기능은 폐분비물의 이동을 저해하는 요소이다. 따라서 기도내의 분비물의 이동을 효과적으로 하여 흡인 시에 최대한의 효과를 돕기 위해 흥곽 물리요법(chest physiotheraphy : CPT)의 한 형태인 흉곽진동법 (Chest Vibration : CV)가 행해져 왔다. 그러나 저체중아를 위한CV의 임상적 적용은 그 대상의 생리적 특성, CV의 적용부위(site)와 기간(duration)에 대한 과학적 근거 없이 만성감염이나 폐질환을 가진 성인이나 cystic fibrosis환자를 위한 CV protocol을 무분별하게 채택하여 저체중아에게 행하여져 왔다 이에 본 연구자는 저체중아에 대한 CV의 안전성을 평가하고, 이에 기초하여 저체중아에게 바람직한CV의 형태를 알아보고자 본 연구를 시작하였다. 연구설계는 CV의 안전성을 평가하기 위한 실험연구이다. CV의 안전성은 RDS치료의 가장 일차적 목표인 oxygenation변화에 의해 평가될 수 있으므로, 본 실험 연구에서는 Pulse oximeter에 의해 계속적으로 측정된 산소포화 변화(oxygen saturation change)를 측정하였다. 실험대상은 미국동부에 위치한 대학병원의 NICU에 입원하여 RDS와 관련된 호흡장애로 인공호흡기에 의존해 있는 10명의 저체중아였다. 인공호흡기에 의존된 모든 저체중아는 Pulse oximeter와 심폐기능 측정기(cardiopulmonary monitor)에 의해 산소공급과 호흡상태가 계속 측정되고 있었다. 실험대상의 평균 출생시 몸무게는 평균 1,3050gm(SD=580.6)이었고, 임신월령 은 평균 28.6주(SD=3.1)였다. RDS가 그들의 일차적 진단명이었고, 그중 4명은 pneumonia, atelectasis의 합병증을 가지고 있었다. 10명중 6명은 intermittent mandatory ventilation(IMV)의 형태로, 4명은 continuous positive airway pressure(CPAP)의 형태로 인공호흡기에 의존되어 있었고 CV시의 FiO2는 평균 42.3(SD=21.2)였다. CV는 중환아용 소형진동기 (minivibrator)를 이용해 가각 10명 의 간호사에 의해 행하여 졌고, 최소 22초에서 최대 100초 동안 실시되었다. 50%의 간호사는 30초에서 40초간 CV를 실시하였으며, CV의 적용부위도, 전후 흉곽부위, 혹은 병변이 있는 좌 우측, 흑은 양쪽 흉벽 등으로 다양했고, 적용방법도 원형으로 돌려가며(circular motion), 혹은 아래에서 위로, 혹은 아무런 기준없이 간호사의 기호에 따라 다양하게 적용되었다. 산소포화의 변화는 CV가 행해지기 전.후로 5초동안 관찰되었다. 연구의 결과, 산소포화 변화는 비 모수통계(non parametric statistics)의 일종인 Matched Paired Wilcoxon test로 분석 한 결과 CV후에 3%의 감소를 보였다(P<.05). 저체중아에 있어 산소포화의 3%감소는 임상적으로 중요한 의미가 없다고 사료되어지며, 실제 흡인전의 과도호흡에 의해 CV를 행하기 이전의 산소공급수준으로 돌아 왔다. CV실시 기간과 산소포화와의 상관관계는 비 모수통계인 Spearman rho correlation coefficient를 이용하여 분석하였는데, 이 두 변수는 서로 관계가 없는 것으로 나타났다(P>.05) 또한 CV와 흡인 후에 각각의 간호사들에게 CV를 필요로 한 저체중아의 기준, 적용부위, 기간, 방법등에 대한 기준을 물었으나 대상의 특성에 따른 간호사정에 의존하기보다는 간호사 각자의 선호하는 방법이나 습관에 라 행하는 것으로 나타났다. 결론적으로 CV와 산소포화 변화와의 관계, NICU에서 관찰된 CV의 임상적 적용을 기초로 저체중아에게 안전한 CV protocol은 신생아용 소형 진동기를 이용하여, 양쪽 흉곽의 늑골하측 변연 부위(low lateral costal margin)에서 시작하여 흉골 중앙부위 방향으로 30초 동안 진동기를 적용하는 것이 좋은 것으로 나타났다. 이에 CV의 효과를 평가하기 위한 보다 과학적인 접근방법으로, CV와 흡인의 결과인 가래(sputum)에 대한 연구를 제언하는 바이다.

  • PDF

Development of the Pulse Tube Cryocooler for Infrared Detector (적외선 검출기용 맥동관 극저온 냉동기 기술개발)

  • Yeom, Hankil;Park, Seoung-Je;Hong, Hong-Ju;Ko, Junseok;In, Sehwan;Kim, Hyo-Bong
    • Transactions of the KSME C: Technology and Education
    • /
    • v.3 no.4
    • /
    • pp.241-248
    • /
    • 2015
  • Most of the Stirling cryocoolers used for infrared detector cooling in domestic is imported. Because the cooler has a high price, short life and poor durability, demand for the coolers continues steadily. However, the cooler is highly related to defense and space technology, technology transfer or co-development with the countries having experties in cooler design is very limited. The pulse tube cooler to be developed in this study is such that the mechanical piston in low temperature actuating part is replaced by the gas piston and linear compressor is adopted, which results in low vibration, long life and better durability. It is expected that development of the pulse tube cooler will not only improve our technology to the level of advanced countries, but also enhance the skills in designing and manufacturing of the infrared detector.

Dynamic Analyses on Embedded Piles Based on Wave Equation (파동방정식에 근거한 매입말뚝의 동적 분석)

  • Seo, Mi-Jeong;Park, Jong-Bae;Park, Yong-Boo;Lee, Jong-Sub
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.11
    • /
    • pp.5-13
    • /
    • 2015
  • For the bearing capacity evaluation, dynamic pile tests instead of static pile tests have been commonly used in embedded piles, which are known to have low noise and low vibration construction method. The objective of this study is to analyze the bearing capacity and penetration behaviors of embedded piles, which are constructed in different ground conditions, by using force and velocity signals obtained in the final blows during construction of embedded piles. For the dynamic pile analyses, the CAse Pile Wave Analysis Program (CAPWAP) and Wave Equation Analysis of Piles (WEAP) have been commonly used. In this study, the CAPWAP and WEAP are used for the analyses of the dynamic pile tests, which are conducted on embedded piles. The input values, output values, and force-velocity graphs of CAPWAP determined by analyzing the measured force-velocity signals are investigated. In addition, similar force-velocity singals are obtained from the WEAP by analyzing the input values of the WEAP. Considering the subsurface investigation results around the pile tips, if the N-value increases exponentially along the depth, toe quake value should be small, and therefore large bearing capacity is identified. On the contrary, if the N-value increases linearly, the bearing capacity is small because of large toe quake value. Furthermore, the stiffness of hammer cushion and pile cushion, which is difficult to find correct values, is recommended lower than 500 kN/mm. This study demonstrates that the results of WEAP may be similar to those of CAPWAP and the WEAP can be used to estimate the bearing capacity of embedded piles.

New Gain Function Based on Attenuation Characteristics of Ballast Track for GPR Analysis (GPR 분석을 위한 자갈궤도 자갈의 감쇄특성을 이용한 이득함수 개발)

  • Shin, Jihoon;Choi, Yeongtae;Jang, SeungYup
    • Journal of the Korean GEO-environmental Society
    • /
    • v.18 no.4
    • /
    • pp.13-21
    • /
    • 2017
  • Ballasted track has been used as track system for more than 100 years. Ballasted track has advantages of low construction cost, flexible maintenance, low noise and vibration, and so on. However, ballasted track leads to continuous settlement which causes maintenance. Recently, increase in speed, traffic volume, and weight of train requires more frequent maintenance. Fouling, well-known phenomenon of accumulation of fine materials due to intrusion of subgrade and breakage of ballast materials, expedites the settlement (i.e., irregular settlement) of track. Ground Penetrating Radar (GPR) can be one of non-destructive tools that can evaluate fouling level of ballast. In this paper, a gain function based on the attenuation characteristics of ballast material is suggested in conjunction with Hilbert transform. Lab box tests and full-scale tests indicate that the suggested method reasonably classifies clean, fouled layers, and subgrade. However, additional study to eliminate effect of sleeper and to include the scattering features of the electromagnetic wave in ballast voids should be required in order to enhance the accuracy.

The Detailed Design of the NISS onboard NEXTSat-1

  • Jeong, Woong-Seob;Park, Sung-Joon;Moon, Bongkon;Lee, Dae-Hee;Park, Won-Kee;Lee, Duk-Hang;Ko, Kyeongyeon;Pyo, Jeonghyun;Kim, Il-Joong;Park, Youngsik;Nam, Ukwon;Kim, Minjin;Ko, Jongwan;Im, Myungshin;Lee, Hyung Mok;Lee, Jeong-Eun;Shin, Goo-Hwan;Chae, Jangsoo;Matsumoto, Toshio
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.2
    • /
    • pp.39.3-40
    • /
    • 2015
  • The NISS (Near-infrared Imaging Spectrometer for Star formation history) onboard NEXTSat-1 is the near-infrared instrument optimized to the first small satellite of NEXTSat series. The capability of both imaging and low spectral resolution spectroscopy in the near-infrared range is a unique function of the NISS. The major scientific mission is to study the cosmic star formation history in local and distant universe. For those purposes, the main targets are nearby galaxies, galaxy clusters, star-forming regions and low background regions. The off-axis optical design of the NISS with two linear variable filters is optimized to have a wide field of view ($2deg.{\times}2deg.$) as well as the wide wavelength range from 0.95 to $3.8{\mu}m$. The mechanical structure is considered to endure the launching condition as well as the space environment. The dewar inside the telescope is designed to operate the infrared detector at 80K stage. From the thermal analysis, we confirmed that the telescope and the dewar can be cooled down to around 200K and 80K, respectively in order to reduce the large amount of thermal noise. The stray light analysis is shown that a light outside a field of view can be reduced below 1%. After the fabrications of the parts of engineering qualification model (EQM), the NSS EQM was successfully assembled and integrated into the satellite. To verify operations of the satellite in space, the space environment tests such as the vibration, shock and thermal-vacuum test were performed. Here, we report the results of the critical design review for the NISS.

  • PDF

A Study on Design of Earth-Retaining Structure Constructed by a Row of Bored Piles (주열식(柱列式) 흙막이벽(壁)의 설계(設計)에 관한 연구(研究))

  • Hong, Won Pyo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.5 no.2
    • /
    • pp.11-18
    • /
    • 1985
  • A row of bored piles has been used in several excavation works to retain the earth. This excavation bracing system has much effect on low-vibration and low-noise during construction. The system is also effective to provide protection to the adjacent existing ground and structures. For the purpose of establishment of a logical design method for the bored piles, first, a theoretical equation to estimate the resistance of piles is derived. Because arching action of soils between piles is considered in the equation, the characteristics of soils and the installation condition of piles would be considered logically from the beginning. Then a method is investigated to decide the interval ratio of piles. According to the method, the interval between piles can be decided from the information of the Peck's stability number, the coefficient of lateral earth pressure and the internal friction angle of soil. Finally, a design method is presented for the bored piles used for excavation work. In the presented design method, such factors as depth of excavation, pile diameter, interval between piles, pile length below bottom of excavation and pile stiffness, can be selected systematically.

  • PDF

Rotordynamic Analysis of a Dual-Spool Turbofan Engine with Focus on Blade Defect Events (블레이드 손상에 따른 이축식 터보팬 엔진의 동적 안정성 해석)

  • Kim, Sitae;Jung, Kihyun;Lee, Junho;Park, Kihyun;Yang, Kwangjin
    • Tribology and Lubricants
    • /
    • v.36 no.2
    • /
    • pp.105-115
    • /
    • 2020
  • This paper presents a numerical study on the rotordynamic analysis of a dual-spool turbofan engine in the context of blade defect events. The blades of an axial-type aeroengine are typically well aligned during the compressor and turbine stages. However, they are sometimes exposed to damage, partially or entirely, for several operational reasons, such as cracks due to foreign objects, burns from the combustion gas, and corrosion due to oxygen in the air. Herein, we designed a dual-spool rotor using the commercial 3D modeling software CATIA to simulate blade defects in the turbofan engine. We utilized the rotordynamic parameters to create two finite element Euler-Bernoulli beam models connected by means of an inter-rotor bearing. We then applied the unbalanced forces induced by the mass eccentricities of the blades to the following selected scenarios: 1) fully balanced, 2) crack in the low-pressure compressor (LPC) and high pressure compressor (HPC), 3) burn on the high-pressure turbine (HPT) and low pressure compressor, 4) corrosion of the LPC, and 5) corrosion of the HPC. Additionally, we obtained the transient and steady-state responses of the overall rotor nodes using the Runge-Kutta numerical integration method, and employed model reduction techniques such as component mode synthesis to enhance the computational efficiency of the process. The simulation results indicate that the high-vibration status of the rotor commences beyond 10,000 rpm, which is identified as the first critical speed of the lower speed rotor. Moreover, we monitored the unbalanced stages near the inter-rotor bearing, which prominently influences the overall rotordynamic status, and the corrosion of the HPC to prevent further instability. The high-speed range operation (>13,000 rpm) coupled with HPC/HPT blade defects possibly presents a rotor-case contact problem that can lead to catastrophic failure.