• Title/Summary/Keyword: Low Vibration

Search Result 2,166, Processing Time 0.032 seconds

The Effects of Vibration Frequency and Amplitude on Serratus Anterior Muscle Activation During Knee Push-up Plus Exercise in Individuals with Scapular Winging (어깨뼈 익상에 대한 푸쉬업플러스 시 부가적 진동의 주파수와 진폭이 어깨안정근 근활성도에 미치는 영향)

  • Park, Won-Young;Koo, Hyun-Mo
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.13 no.4
    • /
    • pp.67-74
    • /
    • 2018
  • PURPOSE: This study was conducted to investigate the effects of vibration frequency and amplitude on scapular winging during the knee push-up plus exercise. METHODS: A total of 26 female subjects with scapular winging were evaluated while performing the knee push-up plus exercise with no vibration, low-frequency/low-amplitude (5 Hz/3 mm) vibration, low-frequency/high-amplitude (5 Hz/9 mm) vibration, high-frequency/low-amplitude (15 Hz/3 mm) vibration, and high-frequency/high-amplitude (15 Hz/9 mm) vibration. The surface EMG of the serratus anterior (SA) muscle was compared between the vibration frequency and amplitude. The EMG amplitude was normalized using the maximal voluntary isometric contraction (MVIC). The statistical significance of the results was evaluated using one-way ANOVA. RESULTS: The SA muscle EMG values increased at low-frequency/low-amplitude vibration and at low-frequency/high-amplitude vibration compared to no vibration. Furthermore, the same values increased at high-frequency/low-amplitude vibration and high-frequency/high-amplitude vibration compared to no vibration. In general, a higher vibration frequency and amplitude was associated with higher EMG values of the SA muscle, with particularly greater increases observed during high-frequency/high-amplitude vibration. There was also a significant difference between each condition with a high-frequency/high-amplitude vibration (p<.05). CONCLUSION: This study suggests that there were remarkable clinical effect of the knee push-up plus exercise with vibration, which enhanced the SA muscle activation in persons with scapular winging. Furthermore, applying a higher vibration frequency and amplitude more effectively increased for increasing SA muscle activation.

The Development and Application of Low Vibration Explosives(NewFINECKER) (미진동 화약(NewFINECKER) 개발 및 현장 적용에 관한 연구)

  • Park, Yun-Seok;Jeong, Min-Su
    • Explosives and Blasting
    • /
    • v.28 no.1
    • /
    • pp.11-18
    • /
    • 2010
  • This study improved construction and cost efficiency that are disadvantages of existing low vibration crackers(low vibration cracker, plasma, etc) and introduced cases of development and practical applications of Low vibration explosives(NewFINECKER) that minimizes blast vibration. The low vibration explosives(NewFINECKER) is suitable to Type-1 among standard blasting patterns of Ministry of Land, Transport and Maritime Affairs(MLTM) and delay blasting is possible. Moreover, the low vibration explosives improve construction and work efficiency while the level of vibration is shown to be about 60~70% of normal emulsion explosives. Additionally, this study suggested standard blasting patterns, the prediction equation of blasting vibration, and construction methods.

Low Frequency Vibration of the Sprung Mass on Front Outer Wheel in Cornering (선회 시 차량의 외측전륜 스프링 상질량의 저주파 진동)

  • Lee, Byung-Rim;Lee, Jae-Eung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1889-1893
    • /
    • 2000
  • During the test drive of developing vehicle, a low frequency vibration of sprung mass on front outer wheel has been frequently observed in cornering with some speed. The purpose of this paper is to investigate the low frequency vibration of the sprung mass. The analysis result shows that the low frequency vibration is caused by sudden migration of the center of gravity of vihicle and it is determined by geometric points of suspension.

  • PDF

Characteristic analysis of low frequency vibration forming (저주파 가진 성형의 특성 분석)

  • Park, C.J.;Choi, J.P.;Park, D.Y.;Hong, N.P.;Lee, H.J.;Lee, N.K.;Kim, S.O.;Chu, Andy;Kim, B.H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.10a
    • /
    • pp.254-258
    • /
    • 2009
  • In this paper, the low frequency vibration forming system is developed for micro-patterns formation on the metal substrate. many researchers have studied about micro-forming technologies such as micro deep drawing, press forming, forging, extrusion etc. for the formation of precise micro-patterns on the surface of metal substrates, multi-step forming process must be used to improve qualifies of the deformed patterns. Since the low frequency vibration forming system could easily deform the surface of metal substrates, several steps of multi-step forming process should be removed by using the low frequency vibration forming system. In order to find optimal process conditions, we have carried out low frequency vibration forming process with varying the vibration frequency from 110Hz to 500Hz.

  • PDF

A Case Study on the Application of Low Vibration Explosives(LoVEX) in Tunnel Blasting (미진동화약을 적용한 터널발파 사례 연구)

  • Lee, Dong-Hoon;Park, Yun-Seok;Lee, Dong-Hee;Yoo, Joung-Hoon
    • Explosives and Blasting
    • /
    • v.30 no.2
    • /
    • pp.59-65
    • /
    • 2012
  • This study improved constructability and cost efficiency that are disadvantages of existing a mechanical excavation & similar blasting methods(plasma, gel, etc) and introduced cases of development and practical applications of Low vibration explosives(LoVEX) that minimizes blast vibration. The low vibration explosives(LoVEX) is suitable to Type-1 in standard blasting patterns of Ministry of Land, Transport and Maritime Affairs(MLTM) and delay blasting is possible. Moreover, the low vibration explosives improve construction and work efficiency while the level of vibration is reduced to about 60~70% of normal emulsion explosives. Additionally, this study suggested standard blasting patterns, the prediction equation of blasting vibration, and construction methods.

A Study on the Noise and Vibration Characteristics during Construction of Screw Concrete Pile for Reduction of Noise and Vibration (소음 및 진동 저감을 위한 스크류콘크리트말뚝의 시공 중 소음과 진동 특성에 관한 연구)

  • Kim, Dongchul;Choi, Yongkyu
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.9
    • /
    • pp.21-30
    • /
    • 2013
  • Because the noise and vibration regulations in domestic areas are being tightened more and more, a more environmentfriendly method than the current low-noise & low-vibration methods is needed. In this study, the characteristics of screw concrete piles for reduction of noise and vibration were explained, and during pilot tests the noise and vibration were measured. The measured vibration value is satisfied with the vibration regulations at 7.5m distance from the source. The measured noise value is exceeded over about 2dB(A) at the 15.0m distance from the source but these values are about 5~20dB(A) less than the measured values of the current low-noise & low-vibration method.

Case History of Low Vibration and Low Noise Granular Pile Method in the Area of Incurred the Popular Enmity (민원발생지역에서의 저진동$\cdot$저소음 Granular Pile의 시공사례)

  • Chun, Byung-Sik;Kim, Baek-Young
    • Proceedings of the KSR Conference
    • /
    • 2003.10b
    • /
    • pp.176-181
    • /
    • 2003
  • Damages by vibration and noise due to the construction performance are increasing. The rise of construction demand and enlargement of equipments are major reasons of this damage. As a result, the enmity of the people is provoked and this appears to be an obstacle of construction work. Especially, in case of ground improvement construction. Casing pipe is inserted into the Sand Drain, Sand Compaction Pile and Vibrated Crushed-stone Pile by vibration power when carrying out. Hence, a pillar is formed and it creates vibration and noise. This causes a lot of restrictions to construction condition. The low Vibration and low noise construction equipments uses earth auger and hydrulic cylinder for insertion and chopping operation instead of vibro hammer, which is the source of vibration and noise. This minimize ground disturbanceand decrease vibration and noise successfully, but increase chopping effect greatly. Thus, this new equipment is not only suitable for environment but also excellent engineering method of construction.

  • PDF

A State of the Art on a Noise & Vibration - Free PHC Screw Pile Method (무소음.무진동 스크류 PHC 말뚝공법에 관한 기술적 수준 고찰)

  • Ha, Young-Min;Jung, Ho-Young;Kim, Young-Pil;Kim, Sung-Su;Choi, Yong-Kyu
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.496-506
    • /
    • 2009
  • Various the low noise & vibration pile methods were developed and used in many construction sites. Low noise & vibration pile methods must be used essentially from the sites where popular complints would be expected. In this paper, low noise & vibration pile methods and screw pile methods were investigated, noise & vibration-free screw PHC pile method, also, was studied and its constructibility and applicability were analyzed.

  • PDF

Influence of Local Vibratory Stimulation of Acute Low Back Pain (급성 요통에 대한 국소진동 자극의 영향)

  • Kang, Jong-Ho;Bang, Hyun-Soo;Choen, Song-Hee;Park, Soo-Jin;Kim, Jin-Sang
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.2 no.2
    • /
    • pp.135-142
    • /
    • 2007
  • Purpose : To investigate the effectiveness of local vibration and interferential therapy for patient with acute low back pain. Methods : A randomized trial designed to compare interferential therapy and local vibration therapy for acute low back pain in primary care setting Results : A total of 60 patients were recruited. The two treatment groups had similar demographic and clinical baseline characteristics. The mean VAS scores before treatment was 8.290 for interferental therapy group and 8.572 for local vibration therapy groups. After treatment, this VAS score had dropped to 4.812(interferental therapy group, at 7 days), and 4.945(local vibration group, at 7 days). Conclusion : This study shows a progressive fall in visual analog scale scores in patients with acute low back pain treated with either interferential therapy and local vibration therapy. There was some difference in the improvement between the two groups at 1 to 4 days, VAS score of vibration therapy groups was low better than interferential therapy groups.

  • PDF

Experimental Study for Prediction of Ground Vibration Responses by the Low-vibration Pile Driving Methods (저진동 파일시공법에 따른 지반진동 응답 예측을 위한 실험적 연구)

  • Kang, Sung-Hoo;Jeoung, Sug-Kyu;Park, Sun-Joon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.4
    • /
    • pp.299-306
    • /
    • 2011
  • This study investigated the SIP-method as a low-vibration, low-noise engineering method. The ground vibrations caused by the SIP-method were measured and analyzed in each step. From the analysis results, quantitative ground vibration values and reliable vibration estimation equations were proposed. Furthermore, the ground vibrations caused by the SIP-method were compared with the ground vibrations caused by other methods presented by existing studies. Based on the vibration estimation equation with 50 % reliability, the ground vibration values by the SIP-method at the distance of 10~150 m corresponded to 17~57 % of the ground vibration values by the equation proposed by Attewell & Famer, and 14~96 % of the ground vibration values by the equation proposed by Prof. Park in his study using a diesel drop hammer. These results showed that the ground vibration reduction effect of the SIP-method was higher those of other general engineering methods. Finally, the permissible scope of work using the SIP-method which meets the domestic vibration standards was presented.