• Title/Summary/Keyword: Low Illumination

Search Result 358, Processing Time 0.034 seconds

A Study of the Relationship between Visual Charts and Illumination (시표와 조명 사이의 상호관계에 대한 연구)

  • Kim, Douk-Hoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.2
    • /
    • pp.91-96
    • /
    • 1999
  • This study involves the research about relationship between visual charts and illumination. The subjects were both males and females in their teens and twenties. The examination instrument used was a B-VAT II BVS(Mentol) which was produced in the USA, and the illumination used was a low illumination of 100LUX and a high illumination of 1500LUX in the clinical examination room. The results were as follows: 1. Different types of illumination resulted in similar values of visual acuity. 2. In the male teen subjects, the Snellen visual acuity was better than the numerical visual acuity when using low illumination. But the Landolt visual acuity presented similar results when using both low and high illumination. 3. In male subjects in their twenties, the Numerical visual acuity was better than the Landolt and Snellen visual acuity under low illumination. 4. In the female teen subjects, The Snellen visual acuity was better than the Landolt and Numerical visual acuity under low illumination. 5. In the female subjects in their twenties, The Snellen, Landolt and numerical visual acuities were high under low illumination. 6. Different types of illumination resulted in 0.3 or 0.4 variation of visual acuity. 7. The males and females was similar to the visual acuity.

  • PDF

Comparison of the Refracting Power and Aberration according to the Measurement Change in Illumination and Area of the Pupils (조도와 동공 영역의 측정 변화에 따른 굴절력과 수차의 비교)

  • Kim, Bong-Hwan;Han, Seon-Hee;Park, Byeong-Gyu;Hwang, Hyeon-Ju;Bae, Ye-Sol;Seo, Jeong-Bin;Yeo, Ye-Eun;Yoon, Min-Jeong;Kim, Hak-Jun
    • Journal of Korean Clinical Health Science
    • /
    • v.4 no.2
    • /
    • pp.550-555
    • /
    • 2016
  • Purpose. We compared with the refracting power and aberration according to the measurement change in illumination and the pupils area by using the auto refraction instruments. Methods. In this study it were examined 64 eyes without eye disease, 21.4 (${\pm}2.54$) age, 32 (male 10, female 22) patients. Experiments in general illumination using the auto refraction instruments (HRK-8000A, Huvitz, Korea) was measured in both eyes 3 times and after scotopic for 30 minutes in a dark room blocked the light was measured in the same way. Aberration were measured coma, spherical aberration, high and low order aberrations in a general illumination (3500 lux) and low illumination (5 lux) of the pupil area 3.96 mm and 5.96 mm. Results. In the general illumination for measuring of the pupil area, the refractive power, coma, spherical aberration and low order aberration was no significant difference. In the low illumination, spherical aberration of the pupil area was $0.005({\pm}0.015){\mu}m$ in a 3.96mm, $0.014({\pm}0.020){\mu}m$ in a 5.96 mm and appeared a significant difference(p = 0.003). In general and low illumination on the results of comparing the measured values of the refractive power and aberration at the pupil area 3.96 mm, high order aberrations was $0.205({\pm}0.145){\mu}m$ in general illumination, $0.132({\pm}0.075){\mu}m$ in low illumination and appeared a significant differences(p = 0.001). High order aberrations at the pupil area 5.96 mm was $0.278({\pm}0.244){\mu}m$ in general illumination, $0.150({\pm}0.092){\mu}m$ in low illumination and appeared a significant differences(p = 0.000). Conclusions. When the eye refractive power measured by the automatic refraction does not depend on the illumination conditions and size of the observation pupil area, it was found that aberrations are affected by the illumination and the observation pupil area. It was found that the eye examination chamber illumination to obtain accurate measurement produces better results to decrease than to increase.

Changes of Walking Pattern for Young Adults dur ing Level Walking under Low Illumination (20대 남성의 낮은 조도의 평지 보행 시 보행 패턴 변화)

  • Choi, Jin-Seung;Kang, Dong-Won;Bang, Yun-Hwan;Tack, Gye-Rae
    • Korean Journal of Applied Biomechanics
    • /
    • v.20 no.4
    • /
    • pp.381-386
    • /
    • 2010
  • This study examined the changes in the walking pattern during level walking under low illumination conditions. Fourteen male subjects ($22.1{\pm}2.21$ years, $174{\pm}3.74\;cm$, $68.86{\pm}10.81\;kg$) with normal vision and no disabilities were enrolled in this study. All experiments were performed on a level walkway with three conditions: normal walking (preferred & low speed) and walking with low illumination. 3D motion capturing system was used for acquisition and analysis of the walking motion data with a sampling frequency of 120Hz. The walking speed, normalized jerk(NJ) at the center of mass(COM), wrist and heel, knee and elbow joint angle, ratio of the knee joint angle to elbow joint angle and the toe clearance on stance phase were used to compare the differences in walking pattern between the two illumination conditions, The results showed that the walking speed and joint angles decreased in low illumination, whereas the NJ and toe minimum clearance increased. In low illumination, most variables were similar to effects of low speed walking, but toe clearance was different from the effects of low speed. These results can be used as primary data for examining the changes in the level walking pattern of young adults under low illumination. Further study will be needed to compare these results in young adults with those in the elderly.

Effects of mobile texting and gaming on gait with obstructions under different illumination levels

  • Cha, Jaeyun;Kim, Hyunjin;Park, Jaemyoung;Song, Changho
    • Physical Therapy Rehabilitation Science
    • /
    • v.4 no.1
    • /
    • pp.32-37
    • /
    • 2015
  • Objective: This study was conducted to test the effects of mobile texting and gaming on gait with obstructions under different illumination levels. Design: Cross-sectional study. Methods: Twelve healthy adults aged 20 to 36 years (mean 23.5 years) were tested under six different conditions. All participants used touchscreen smartphones. Testing conditions included: 1) Walking with an obstruction under a bright illumination level; 2) walking with an obstruction with a low level of illumination; 3) walking with an obstruction while texting under a bright illumination level; 4) walking with an obstruction while texting with a low level of illumination; 5) walking with an obstruction while gaming under a bright illumination level; and 6) walking with an obstruction while gaming with a low level of illumination. All participants were asked to text the Korean national anthem by their own phone and play Temple Run 2 using an iPhone 5. Gait variances were measured over a distance of 3 m, and the mean value after three trials was used. A gait analyzer was used to measure the data. Results: Compared to normal gait with obstruction, gait speed, step length, stride length, step time, stride time, cadence while texting and gaming showed significant differences (p<0.05). Differences between the illumination levels included gait speed, step length, stride length, and step time (p<0.05) with no significant differences in stride time and cadence. Conclusions: Dual-tasking using a smartphone under low levels of illumination lowers the quality of gait with obstructions.

Electro-Luminescent Display(ELD) Systems for the Cave Illumination

  • Oh, Jong-Woo
    • Journal of the Speleological Society of Korea
    • /
    • no.85
    • /
    • pp.1-14
    • /
    • 2008
  • Electroluminescent Display(ELD) will be the innovative ideas to replace existed electricity illumination systems that consider to under effectiveness and environmental pollution generators in the commercial caves because ELD has less heat and low electricity consumption by the new illumination materials. Characteristics of the ELD are as following: it is a proper matter for the small merchandise ads due to its thickness is only below 3oo micoron, electricity consumption of ELD is less (1/3) than LED, ELD that is a whole face illumination system is much brighter than LED that is a dot illumination system, ELD is longer life than others due to its less light generation systems, ELD is any problems to bend, and it is a best device to use a light board ads. ELD has advantages on conservation of cave biosystems and reduce pollution when ELD is installed in touring spots and emergency corridors of weak illuminated cave internal areas by less heating and low electricity consumption using the indirect illumination of the ELD. Therefore when the high technologic ELD is installed in the commercial caves in Korea, it will be innovating cave environmental systems, saving budgets, and increasing tours.

Design of a Tele-centric Wide Field Lens with High Relative Illumination and Low Distortion Using Third-order Aberration Analysis

  • Kim, Kae-Hong;Kim, Yeong-Sik;Park, Sung-Chan
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.6
    • /
    • pp.679-686
    • /
    • 2015
  • This paper presents a design method for improving the low relative illumination and large distortion due to widening the field of a system. A tele-centric optical system in image space was suggested to increase the relative illumination. Through the analyses of the third-order aberrations affected by introducing aspherical surfaces, we have proposed a method to determine analytically what surface should be aspheric to correct each aberration effectively. By utilizing this method to design a wide field lens, a tele-centric wide field lens with f-number of F/2.0 was obtained. Even though the field angle is 120 degrees, it has a very low distortion less than -2% and high relative illumination more than 73.7%. In conclusion, this analytic method for selecting aspherical surfaces is expected to serve as a useful way to find design solutions.

Fast Correction of Nonuniform Illumination on Bi-level Images using Block Based Intensity Normalization (블록 기반 밝기 표준화를 통한 이진영상의 고속 불균일 조명 보정)

  • Joung, Ji-Hye;Kim, Jeong-Tae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.12
    • /
    • pp.1926-1931
    • /
    • 2012
  • We investigated a novel fast non-uniform illumination correction method for bi-level images. The proposed method divides a bi-level image into sub-images and roughly estimates block-wise illumination by low pass filtered maximum values of sub-images. After that, we apply bilinear interpolation using the block-wise illumination to estimate non-uniform illumination, and compensate for the effect of non-uniform illumination using the estimated illumination. Since the proposed method is not based on computation intensive iterative optimization, the proposed method can be used effectively for applications that require fast correction of non-uniform illumination. In simulations, the proposed method showed more than 20 times faster speed than existing entropy minimization method. Moreover, in simulations and experiments, the restored images by the proposed method were more close to true images than images restored by conventional method.

Insertional mutations exhibiting high cell-culture density HCD phenotypes are enriched through continuous subcultures in Chlamydomonas reinhardtii

  • Thung, Leena;He, Jing;Zhu, Qingling;Xu, Zhenyu;Liu, Jianhua;Chow, Yvonne
    • ALGAE
    • /
    • v.33 no.1
    • /
    • pp.127-141
    • /
    • 2018
  • Low efficiency in microalgal biomass production was largely attributed to the low density of algal cell cultures. Though mutations that reduced the level of chlorophyll or pigment content increased efficiency of photon usage and thus the cell-culture density under high-illumination growth conditions (e.g., >$500{\mu}mol\;photon\;m^{-2}\;s^{-1}$), it was unclear whether algae could increase cell-culture density under low-illumination conditions (e.g., ${\sim}50{\mu}mol\;photon\;m^{-2}\;s^{-1}$). To address this question, we performed forward genetic screening in Chlamydomonas reinhardtii. A pool of >1,000 insertional mutants was constructed and subjected to continuous subcultures in shaking flasks under low-illumination conditions. Complexity of restriction fragment length polymorphism (RFLP) pattern in cultures indicated the degree of heterogeneity of mutant populations. We showed that the levels of RFLP complexity decreased when cycles of subculture increased, suggesting that cultures were gradually populated by high cell-culture density (HCD) strains. Analysis of the 3 isolated HCD mutants after 30 cycles of subcultures confirmed that their maximal biomass production was 50-100% higher than that of wild type under low-illumination. Furthermore, levels of chlorophyll content in HCD mutant strains were similar to that of wild type. Inverse polymerase chain reaction analysis identified the locus of insertion in two of three HCD strains. Molecular and transcriptomic analyses suggested that two HCD mutants were a result of the gain-of-function phenotype, both linking to the abnormality of mitochondrial functions. Taken together, our results demonstrate that HCD strains can be obtained through continuous subcultures under low illumination conditions.

Characteristics of th Distribution of Night Illumination Level at Urban Neighborhood Parks (도시근린공원의 야간조도분포의 특성)

  • 최연철;김진선
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.28 no.4
    • /
    • pp.66-74
    • /
    • 2000
  • The purpose of this study is to research and analyze the distribution of night illumination level at urban neighborhood parks and to show its characteristics. And this is used basic data ensuring safety and satisfying aesthetic and psychological desires of people who use urban neighborhood parks at night. To research and analyze the distribution of illumination level at urban neighborhood parks at night. To research and analyze the distribution of illumination level at urban neighborhood parks, I selected 8 urban neighborhood parks as the subject of research in this study, set the measuring standard of illumination level, and measured the illumination level by the measuring standard. The results of this study are as follows; 1. Currently, total average illumination level of urban neighborhood parks was lower than the minimum standard of illumination level I KS A 3011-1993. 2. Average illumination level of each place in urban neighborhood parks appeared variously from low level to high level. But this was lower than the minimum standard illumination level in KS A3011-1993 like total average illumination level. 3. The higher was total average illumination level of urban neighborhood parks, the more various was brightness of places. Although users' aesthetic and mental desire or behavioral aspect relate with safety cannot be found by only survey and analyses of illumination level, it is judged that first, illumination level of the standard of the lightness should be analyzed to find user's mental states and behaviors in external space at night. Therefore, it is considered that this study, which analyzed characteristics illumination level as basic data, has a significance. The study continuing for other illuminative environmental factors suitable in the place is required because the brightness of places may not be measured by only illumination level. And the proper illumination level in outdoor places should be showed in considering psychological and behavioral aspects of human as people may have their own sense of brightness.

  • PDF