• Title/Summary/Keyword: Low Dose Radiation

Search Result 944, Processing Time 0.026 seconds

A Study for Effects of Image Quality due to Scatter Ray produced by Increasing of Tube Voltage (관전압 증가에 기인한 산란선 발생의 화질 영향 연구)

  • Park, Ji-Koon;Jun, Je-Hoon;Yang, Sung-Woo;Kim, Kyo-Tae;Choi, Il-Hong;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.663-669
    • /
    • 2017
  • In diagnostic medical imaging, it is essential to reduce the scattered radiation for the high medical image quality and low patient dose. Therefore, in this study, the influence of the scattered radiation on medical images was analyzed as the tube voltage increases. For this purpose, ANSI chest phantom was used to measure the scattering ratio, and the scattering effect on the image quality was investigated by RMS evaluation, RSD and NPS analysis. It was found that the scattering ratio with increasing x-ray tube voltage gradually increased to 48.8% at 73 kV tube voltage and to 80.1% at 93 kV tube voltage. As a result of RMS analysis for evaluating the image quality, RMS value according to increase of tube voltage was increased, resulting in low image quality. Also, the NPS value at 2.5 lp/mm spatial frequency was increased by 20% when the tube voltage was increased by 93 kV compared to the tube voltage of 73 kV. From this study, it can be seen that the scattering radiation have a significant effect on the image quality according to the increase of x-ray tube voltage. The results of this study can be used as basic data for the improvement of medical imaging quality.

Development of Neutron, Gamma ray, X-ray Radiation Measurement and Integrated Control System (중성자, 감마선, 엑스선 방사선 측정 및 통합 제어 시스템 개발)

  • Ko, Tae-Young;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.21 no.4
    • /
    • pp.408-411
    • /
    • 2017
  • In this paper, we propose an integrated control system that measures neutrons, gamma ray, and x-ray. The proposed system is able to monitor and control the data measured and analyzed on the remote or network, and can monitor and control the status of each part of the system remotely without remote control. The proposed system consists of a gamma ray/x-ray sensor part, a neutron sensor part, a main control embedded system part, a dedicated display device and GUI part, and a remote UI part. The gamma ray/x-ray sensor part measures gamma ray and x-ray of low level by using NaI(Tl) scintillation detector. The neutron sensor part measures neutrons using Proportional Counter Detector(low-level neutron) and Ion Chamber Type Detector(high-level neutron). The main control embedded system part detects radiation, samples it in seconds, and converts it into radiation dose for accumulated pulse and current values. The dedicated display device and the GUI part output the radiation measurement result and the converted radiation amount and radiation amount measurement value and provide the user with the control condition setting and the calibration function for the detection part. The remote UI unit collects and stores the measured values and transmits them to the remote monitoring system. In order to evaluate the performance of the proposed system, the measurement uncertainty of the neutron detector was measured to less than ${\pm}8.2%$ and the gamma ray and x-ray detector had the uncertainty of less than 7.5%. It was confirmed that the normal operation was not less than ${\pm}15$ percent of the international standard.

TID and SEL Testing on PWM-IC Controller of DC/DC Power Buck Converter (DC/DC 강압컨버터의 PWM-IC 제어기의 TID 및 SEL 실험)

  • Lho, Young Hwan;Hwang, Eui Sung;Jeong, Jae-Seong;Han, Changwoon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.1
    • /
    • pp.79-84
    • /
    • 2013
  • DC/DC switching power converters are commonly used to generate a regulated DC output voltage with high efficiency. The DC/DC converter is composed of a PWM-IC (pulse width modulation-integrated circuit) controller, a MOSFET (metal-oxide semiconductor field effect transistor), inductor, capacitor, etc. It is shown that the variation of threshold voltage and the offset voltage in the electrical characteristics of PWM-IC increase by radiation effects in TID (Total Ionizing Dose) testing at the low energy ${\gamma}$ rays using $^{60}Co$, and 4 heavy ions applied for SEL (Single Event Latch-up) make the PWM pulse unstable. Also, the output waveform for the given input in the DC/DC converter is observed by the simulation program with integrated circuit emphasis (SPICE). TID testing on PWM-IC is accomplished up to the total dose of 30 krad, and the cross section($cm^2$) versus LET($MeV/mg/cm^2$) in the PWM operation is studied at SEL testing after implementation of the controller board.

Fast Neutron Dosimetry in Criticality Accidents (핵임계사고시(核臨界事故時)에 있어서 속중성자선량(速中性子線量)의 해석(解析))

  • Ro, Seung-Gy;Yook, Chong-Chul
    • Journal of Radiation Protection and Research
    • /
    • v.1 no.1
    • /
    • pp.1-9
    • /
    • 1976
  • A suggestion has been made for neutron dosimetric techniques using activation and threshold detectors in criticality accidents. Neutron dosimetrical parameters, namely, the fission spectrum-averaged cross-sections of some threshold reactions and fluence-to-dose conversion factors have been calculated by the use of an electronic computer. It appears that detectors having comparatively high threshold energy give more fine information on spectral deformation in criticality accidents, while detectors with low threshold energy are of usefulness for measuring fast neutron fluence regardless of fissioning types. Unexpectedly it is found that the fission spectrum-averaged cross sections of the $^{32}S(n,\;p)^{32}P$ reaction is not sensitive to analytical forms of fission neutron spectrum: the modified Cran-berg and Maxwellian forms. In addition, the fluence-to-dose conversion factors seem to be insensitive to both spectral functions and fissioning types.

  • PDF

Radiation Effect on Airway Obstruction from Lung Cancer (폐암으로 유발된 무기폐에 대한 방사선 치료의 효과)

  • Shin, Sei-One;Kim, Sung-Kyu;Kim, Myung-Se
    • Journal of Yeungnam Medical Science
    • /
    • v.6 no.2
    • /
    • pp.121-125
    • /
    • 1989
  • Total 21 patients with airway obstruction from lung cancer treated with radiotherapy at Department of Therapeuctic Radiology, Yeungnam University College of Medicine, between April 1986 and December 1988 are retrospectively analysed by means of roentgenologic findings. Obtained results are as follows. 1. 15 out of 21 patients(71%) showed complete or partial response. 2. Patients with small cell lung cancer showed 100% response in spite of low dose(30GY/10 fractions). 3. Patients with non-small cell lung cancer treated with 50GY or over showed better response than below 45GY or below. 4. There is no relationship between the response and site of airway obstruction. These data suggested that high dose irradiation is more effective in the management of airway obstruction from lung cancer and meticulous radiotherapy planning with appropriate protection of normal lung and critical organs should be investigated in order to maximize radiation effect and minimize side effect, complication or sequelae.

  • PDF

Development of Ready-to-Eat Bulgogi Sauce with No Change of Sensory Properties after High-Dose Irradiation

  • Shin, Mee-Hye;Park, Jin-Gyu;Kim, Cheon-Jei;Lee, Ju-Woon
    • Food Science of Animal Resources
    • /
    • v.31 no.3
    • /
    • pp.366-371
    • /
    • 2011
  • Viscosity is critically important for bulgogi sauce. However, exposure to irradiation may decrease the rheological properties of bulgogi sauce. This study was conducted to compare the effects of gamma irradiation (0-9 kGy) on viscosity, molecular weight, pH, reducing end level, and water solubility of xanthan gum, guar gum, and locust bean gum as thickening agents/stabilizers in bulgogi sauce. The physicochemical properties of all samples changed (p<0.05) from 3965 to 0 cP (viscosity), from 6048 to 28 kDa (molecular weight), from 5.79 to 4.62 (pH), from 0.13 mg/mL to 1.72 mg/mL (reducing end level), and from 6% to 87% (water solubility) following gamma irradiation. Viscosity after irradiation was most stable (p<0.05) in xanthan gum (from 1249 to 92 cP) compared with guar gum (from 3965 to 0 cP) and locust bean gum (from 1631 to 0 cP). The sensory properties (texture and taste) of bulgogi sauce prepared with xanthan gum (1%, w/w) were highly maintained (about 7.0-5.0) after high-dose irradiation of up to 40 kGy. These results indicate that xanthan gum can be effectively used as a thickening agent/stabilizer in bulgogi sauce, which had low viscosity after irradiation.

Effects of Uranyl Nitrate on $Na^{+}-K^{+}$Adenosine Triphosphatase Activity and Excretion of $Na^{+}\;and\;K^{+}$in Rats (Rat에서 $Na^{+}-K^{+}$ATPase 활성도와 $Na^{+},\;K^{+}$ 배설에 미치는 질산 우라늄의 영향)

  • Lee, Kee-Ho;Yun, Taik-Koo
    • Journal of Radiation Protection and Research
    • /
    • v.14 no.1
    • /
    • pp.1-7
    • /
    • 1989
  • In order to evalulate the cause of polyuric acute tubular necrosis, we measured electrolytes, $Na^{+}\;and\;K^{+}$ excreted in urine, and activities of $Na^{+}-K^{+}$adenosine triphosphatase ($Na^{+}-K^{+}$ATPase) Excretion of $Na^{+}\;and\;K^{+}$ significantly increased in 24hr exposure on the uranyl nitrate and then decreased below the normal level after 3 days. The concentration of $Na^{+}\;and\;K^{+}$ in urines of the rats treated uranyl nitrate was less than that of the normal rats. The activities of $Na^{+}-K^{+}$ATPase decreased only in the group treated with high dose group of uranyl nitrate (30mg/kg BW) on the 3rd day but were not changed in the low dose groups(5 mg/kg BW and 15mg/kg BW).

  • PDF

Effects of different UV-8 levels on the growth, photosynthesis and pigments in cucumber(Cucumis sativus L.) (UV-B 강도 변화가 오이(Cucumis sativus L.)의 생장, 광합성 및 색소에 미치는 영향)

  • Kim, Hak-Yoon;Lee, In-Jung;Shin, Dong-Hyun;Kim, Kil-Ung
    • Journal of Life Science
    • /
    • v.8 no.3
    • /
    • pp.272-278
    • /
    • 1998
  • To investigate the effects of different UV-B levels on plant growth, cucumber plants were subjected to three levels of biologically effective ultraviolet-B(UV--$B^{BE}$ radiation [daily dose : 0.03(No UV-B), 6.40(Low UV-B) and 11.30 (High UV-B) kJ $m^{-2}$, UV--$B^{BE}$] in the growth chambers for 3 weeks during the early growth period. High and low levels of UV-B irradiation drastically decreased both dry weight and leaf area, but increased specific leaf weight of cucumber. Plants subjected to UV-B resulted in 30% and 20% reduction of photosynthesis rate by high and low UV-B, respectively. However, respiration rate was not affected by the UV-B. With increasing UV-B intensity, total chlorophyll contents were decreased linearly, while the contents of flavonoid were increased linearly. These results suggest that the present levels of UV-B may affect the growth of cucumber plant compared with a UV-B-free condition. It is likely that the growth of cucumber will be affected by enhanced UV-B due to ozone depletion in the near future.

  • PDF

Prognostic value of pretreatment 18F-FDG PET-CT in radiotherapy for patients with hepatocellular carcinoma

  • Jo, In Young;Son, Seok-Hyun;Kim, Myungsoo;Sung, Soo Yoon;Won, Yong Kyun;Kang, Hye Jin;Lee, So Jung;Chung, Yong-An;Oh, Jin Kyoung;Kay, Chul-Seung
    • Radiation Oncology Journal
    • /
    • v.33 no.3
    • /
    • pp.179-187
    • /
    • 2015
  • Purpose: The purpose of this study was to investigate the predictable value of pretreatment $^{18}F$-fluorodeoxyglucose positron emission tomography-computed tomography ($^{18}F$-FDG PET-CT) in radiotherapy (RT) for patients with hepatocellular carcinoma (HCC) or portal vein tumor thrombosis (PVTT). Materials and Methods: We conducted a retrospective analysis of 36 stage I-IV HCC patients treated with RT. $^{18}F$-FDG PET-CT was performed before RT. Treatment target was determined HCC or PVTT lesions by treatment aim. They were irradiated at a median prescription dose of 50 Gy. The response was evaluated within 3 months after completion of RT using the Response Evaluation Criteria in Solid Tumors (RECIST). Response rate, overall survival (OS), and the pattern of failure (POF) were analyzed. Results: The response rate was 61.1%. The statistically significant prognostic factor affecting response in RT field was maximal standardized uptake value (maxSUV) only. The high SUV group (maxSUV ${\geq}5.1$) showed the better radiologic response than the low SUV group (maxSUV < 5.1). The median OS were 996.0 days in definitive group and 144.0 days in palliative group. Factors affecting OS were the %reduction of alpha-fetoprotein (AFP) level in the definitive group and Child-Pugh class in the palliative group. To predict the POF, maxSUV based on the cutoff value of 5.1 was the only significant factor in distant metastasis group. Conclusion: The results of this study suggest that the maxSUV of $^{18}F$-FDG PET-CT may be a prognostic factor for treatment outcome and the POF after RT. A %reduction of AFP level and Child-Pugh class could be used to predict OS in HCC.

Radiation Exposure of an Astronaut subject to Various Space Radiation Environments and Shielding Conditions (다양한 우주방사선 환경과 차폐 조건에서 우주인이 받는 방사선 피폭량)

  • Chae, Myeong-Seon;Chung, Bum-Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.10
    • /
    • pp.1038-1048
    • /
    • 2010
  • Radiation exposures of an astronaut during the space travels to the International Space Station(ISS) of the Soyuz and the Moon of the Apollo, were calculated considering the altitude, boarding time, period of stay, kinds of spaceships and space suits. The calculated radiation exposures decrease dramatically according to the thickness of the shielding by the wall of the spaceships and by the space suits. For the space travel to the ISS of Soyuz at Low Earth orbit, the thickness of the spaceship required to optimally reduce the radiation exposure is 3 cm. For the Extravehicle Mobility Unit(EMU) the exposures are minimized at 4 cm of the aluminized Mylar and 5 cm of the Demron, respectively. The aluminized Mylar showed better radiation shielding than the Demron which contains the high Z materials. The radiation exposures of an astronaut were $4.2\times10^{-6}$ Sv for the ISS travel and $4.3\times10^{-5}$ Sv for the Moon explore. The high concentration of the high energy proton flux at the surface of the Moon results in high radiation exposure. The calculation scheme and results of this study can be used in the design of the shielding performance of a spaceship and space suits.