Condensation heat transfer coefficients of CFC-11 and its alternative refrigerants (CFC-11과 그 대체냉매의 응축 열전달 계수)

  • Joo, Jae-Kil;Cho, Seong-Joon;Jung, Dong-Soo;Kim, Chong-Bo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.6
    • /
    • pp.830-840
    • /
    • 1997
  • In this study, condensation heat transfer coefficients(HTCs) of CFC-11, HCFC-123 and HCFC-141b are measured, which are used/or considered as working fluids in centrifugal chillers. The main objectives of this study are to measure and compare the HTCs of various refrigerants on plain and low fin tubes and also to find out the optimum fin density of the low fin tubes. To accomplish these goals, HTCs of three refrigerants are measured for the plain tube as well as 4 types of low fin tubes. All measurements are carried out at the vapor temperature of 39.deg. C with the wall temperature difference of 3 .deg. C ~ 8.deg. C. For all the refrigerants tested, a low fin tube of 28 fins per inch yielded the best performance among all the tubes tested. For the plain tube, the HTCs of CFC-11 and HCFC-141b were very similar and those of HCFC-123 were 10% lower than those of CFC-11.Thus, it can be concluded that HCFC-123 and HCFC-141b are acceptable as alternative refrigerants for CFC-11 from the view point of condensation heat transfer.

Effect of Condensation on Spray Characteristics of Simplex Swirl Nozzle (응축이 심플렉스 와류 노즐의 분무 특성에 미치는 영향)

  • Koh, Kwang-Uoong;Lee, Sang-Yong
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.107-112
    • /
    • 2001
  • The effect of ambient gas (steam) condensation on swirl spray characteristics were studied experimentally for low subcooling condition of the liquid. The configuration of the liquid(water) sheet and the breakup modes were examined. Also variation of the discharge coefficient, breakup length, local and the cross-sectional area-averaged SMD of droplets with the liquid flow(injection) rate were obtained. The perforation breakup mode appears dominant with condensation while the aerodynamic wave breakup mode is dominant without condensation(in the air environment). The discharge coefficient, breakup length and the mean drop sizes decrease in a same manner with increasing of the liquid flow rate for both cases(with and without condensation). The condensation effects are insignificant with the discharge coefficient. However, the local and cross-sectional area-averaged SMD are larger and the breakup length becomes shorter in the steam environment. The spray angle predicted from the volumetric flux distribution along the radial direction of the sprays in the steam environment becomes larger with condensation.

  • PDF

Efficacy of testicular sperm chromatin condensation assay using aniline blue-eosin staining in the IVF-ET cycle

  • Park, Yong-Seog;Kim, Myo-Kyung;Lee, Sun-Hee;Cho, Jae-Won;Song, In-Ok;Seo, Ju-Tae
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.38 no.3
    • /
    • pp.142-147
    • /
    • 2011
  • Objective: This study was performed to evaluate testicular sperm chromatin condensation using aniline blue-eosin (AB-E) staining and its effects on IVF-ET. Methods: Chromatin condensation was analyzed using AB-E staining in 27 cases of testicular sperm extraction. There were 19 cases of obstructive azoospermia (OA) and 8 cases of non-obstructive azoospermia (NOA) in IVF-ET. Mature sperm heads were stained red-pink whereas immature sperm heads were stained dark blue. The percentage of sperm chromatin condensation was calculated from the ratio of the number of red-pink sperm to the total number of sperm analyzed. Results: The overall percentages of chromatin condensation in OA and NOA were $31.1{\pm}11.2%$ and $26.3{\pm}14.4%$, respectively. The fertilization rate was significant higher in OA than NOA ($p$ <0.05); however, the rates of good embryos and clinical pregnancy did not show statistical differences. In OA and NOA, statistical differences were not observed in the rate of chromatin condensation, fertilization, good embryos, and clinical pregnancy between the pregnant group and non-pregnant group. Conclusion: Chromatin condensation is less stable than OA and showed a low fertilization rate in NOA. While there were no significant differences in chromatin condensation results between NOA and OA, we propose that a pattern of decreased chromatin condensation in NOA is one of the factors of low fertilization results requiring further study.

An Experimental Study on Condensation Heat Transfer Characteristics and Pressure Drop of Plate Heat Exchangers using the Alternative Refrigerant R410A (대체 냉매 R410A를 적용한 판형열교환기의 응축열전달 특성 및 압력강하에 대한 실험적 연구)

  • Kim, Y.H.;Han, D.H.;Lee, K.J.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.220-225
    • /
    • 2001
  • The plate heat exchanger is characterized. by low pressure drop and high heat transfer coefficient. The experimental study has been performed on the condensation heat transfer and pressure drop characteristics of the plate heat exchangers in this study. In the present study, a brazed type plate heat exchanger was investigated at a chevron angle of $45^{\circ},\;55^{\circ},\;and\;70^{\circ}$ with R410A. Condensation temperatures were varied from $20^{\circ}C\;and\;30^{\circ}C$, and mass flux was ranged from $13{\sim}34\;kg/m^{2}s$ with constant heat flux ($=5\;kw/m^{2}$). The heat transfer coefficient and pressure drop increased with the chevron angle. Average condensation heat transfer coefficients and pressure drops are decreased with increasing condensation tempeature.

  • PDF

Forced Ventilation Method for Preventing Surface Condensation of Magazine of Igloo type in Summer (강제환기를 이용한 하절기 군 저장시설의 표면결로 방지에 관한 연구)

  • Park, Sun-Hyo;Yoon, Sung-Do;Sohn, Jang-Yeul
    • KIEAE Journal
    • /
    • v.10 no.2
    • /
    • pp.57-62
    • /
    • 2010
  • In case of earth-covered storage, the condensation occurs on surface of wall and stores in summer with high humidity because of low temperature of constructional mass. Therefore, the preventive plans should be considered to protect stores from the damage by corrosion in earth-covered storages. This study aims to suggest the methods of forced ventilation by the air, to solve the problems of construction's surface condensation at the Magazine of igloo type which is similar to earth-covered storages. A fan was installed at the air outlet for exhaust gas to conduct forced ventilation. The surface and indoor temperature were measured, and then the influence of those on condensation was analyzed. The results of this research are follows; 1) Forced ventilation by a fan affects the rise in surface temperature of walls and stores. 2) The condensation on surface of walls and stores was reduced after operating a fan.

Study on Estimate of Window Condensation performance Due to Temperature Depreciation Ratio (표면 온도 저하율에 따른 창호부 결로성능 예측에 관한 연구)

  • Sung, Uk-Joo;Cho, Soo;Jang, Cheul-Yong;Lee, Jin-Seong;Peak, Sang-Hun
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1255-1260
    • /
    • 2006
  • This present study analyzed temperature depreciation ratio of window inside surface by KS F 2295 'Procedure for determining fenestration product condensation resistance values'. it estimated window indoor surface condensation due to variable environmental condition. Performance of condensation resistance by using temperature depreciation ratio until applied Low-e and Ar glazing improved about 45% from 24 mm clear. Temperature depreciation ratio by KS F 2295 considers analytic index of window condensation due to variable boundary condition.

  • PDF

Condensation heat transfer characteristics of alternative refrigerants for CFC-11, CFC-12 for enhanced tubes (열전달 촉진관에서 CFC-11 및 CFC-12 대체냉매의 응축 열전달 특성 연구)

  • 조성준;황수민;정동수;김종보
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.5
    • /
    • pp.569-580
    • /
    • 1998
  • In this study, condensation heat transfer coefficients(HTCs) of a plain tube, low fin tube, and Turbo-C enhanced tube for CFC-11, HCFC-123, CFC-12, HFC-l34a are measured and compared against each other. All data are taken at the vapor temperature of 39$^{\circ}C$ with a wall subcooling temperature 3~8$^{\circ}C$. Test results show that HTCs of a low vapor pressure refrigerant, HFC-123, for a plain, low fin, and Turbo-C tubes are 10.5~20.5%, 8.2~12.2%, 16.5~19.2% lower than those of CFC-11, respectively. On the other hand, HTCs of a medium vapor refrigerant, HFC-l34a, for a plain, low fin, and Turbo-C tubes are 20.6~31.8%, 0.0~8.0%, 13.2~20.9% higher than those of CFC-12, respectively. For all refrigerants tested, HTCs of Turbo-C tube are the highest among the three tubes showing almost 8 times increase in HTCs as compared to those of a plain tube. Nusselt's prediction equation for a plain tube yielded 12% deviation for all plain tube data while Realty and Katz's prediction equation for a low fin tube yielded 20% deviation for all low tube data.

  • PDF

External Condensation Heat Transfer Coefficients of R1234yf (신냉매 R1234yf의 외부 응축 열전달계수)

  • Park, Ki-Jung;Lee, Cheol-Hee;Kang, Dong-Gyu;Jung, Dong-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.6
    • /
    • pp.345-352
    • /
    • 2010
  • In this study, external condensation heat transfer coefficients(HTCs) of R134a and R1234yf are measured on a plain, low fin, and Turbo-C tubes at the saturated vapor temperature of $39^{\circ}C$ with the wall subcooling of $3{\sim}8^{\circ}C$. R1234yf is a new alternative refrigerant of low greenhouse warming potential for replacing R134a which is one of the greenhouse gases controlled by Kyoto protocol and is used extensively in mobile air-conditioners. Test results show that the external condensation HTCs of R1234yf are very similar to those of R134a for all three surfaces tested. For the application of condensation heat transfer correlations to the design of condensers charged with R1234yf, thorough property measurements are needed for R1234yf in the near future.

A Study on The Drying and Hot Water System Using Condensation Waste Heat (응축폐열을 이용한 건조 및 온수장치에 관한 연구)

  • Park N. H.;Koh H. Y.;Jeong J. W.;Kang T. S.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.15 no.4
    • /
    • pp.362-371
    • /
    • 1986
  • In the normal Refrigeration process, the condensation heat of refrigerant s not been used because of its low-temperature waste heat. To recover the condensation waste heat of R-12 refrigerator, a drying and hot water system was designed and experimented. The results obtained were summarized as follows: 1. As the temperature a temosphere was increased, the temperature of discharge gas of compressor was increased. And the temperature was $80-84^{\circ}C$ for air condensing type and was $68-71^{\circ}C$ for water condensing type during summer. 2. The condensation waste heat could be obtained up to $50-55^{\circ}C$ of drying heat-source and Hot water in summer. In this case, recovered rate was about $73\%$. And the more temperature of drying Heat-source and Hot water were increased, the more a recovered rate were decreased. 3. When comparing drying characteristics of Agro-products in dryer of waste heat utilization and Hot air, there was no quality difference in products. But drying time of the former was 3 Hours longer than the latter. 4. The condensation waste heat of compressor could be applied into the drying of marine products, the predrying of agro-products and making hot water. And showed high possibility of the waste heat using in low-temperature storage.

  • PDF

Condensation Heat Transfer Coefficients of Flammable Refrigerants on Various Enhanced Tubes

  • Park Ki-Jung;Jung Dongsoo
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.10
    • /
    • pp.1957-1963
    • /
    • 2005
  • In this study, external condensation heat transfer coefficients (HTCs) of six flammable refrigerants of propylene (RI270), propane (R290), isobutane (R600a), butane (R600), dimethylether (RE170), and HFC32 were measured at the vapor temperature of $39^{\circ}C$ on a 1023 fpm low fin and Turbo-C tubes. All data were taken under the heat flux of $32\~116\;and\;42\~142kW/m^2$ for the low fin and Turbo-C tubes respectively. Flammable refrigerants' data obtained on enhanced tubes showed a typical trend that external condensation HTCs decrease with increasing wall subcooling. HFC32 and DME showed up to $30\%$ higher HTCs than those of HCFC22 due to their excellent thermophysical properties. Propylene, propane, isobutane, and butane showed similar or lower HTCs than those of HCFC22. Beatty and Katz' correlation predicted the HTCs of the flammable refrigerants obtained on a low fin tube within a mean deviation of $7.3\%$. Turbo-C tube showed the best performance due to its 3 dimensional surface geometry for fast removal of condensate.