• 제목/요약/키워드: Losses analysis

검색결과 1,580건 처리시간 0.034초

손실해석을 통한 능동 클램프 포워드 컨버터의 동작 특성비교 (A Comparative Study of Operation characteristics of Active Clamp Forward Converter Based on Loss Analysis)

  • 오덕진;김희준;김창선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.2039-2041
    • /
    • 1998
  • In this paper, Operation characteristics of the active clamp(ACL) zero-voltage-switching(ZVS) forward converter(FC) and active clamp hard- switching(HS) forward converter are compared with respect to loss analysis. The losses of semiconductor (including conduction losses and switching losses), transformer(containing the core loss and copper loss) and parasitic element of passive element (capacitor, inductor) are measured and compared for each type. For an experiment we have built 50W ACL ZVS-FC and ACL HS-FC, in which the switching frequency is 200kHz, and test it. The experimental results show that both types of operation have nearly same characteristics.

  • PDF

고온초전도동기모터의 시변자계에 따른 회전자의 손실 해석에 관한 연구 (A Study on the Analysis for Electrical Losses of the Rotor considering Time Varying Field of High Tc Superconducting Synchronous Motor)

  • 송명곤;윤용수;장원갑;장인배;이상진;고태국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.340-342
    • /
    • 1998
  • This paper presents the ac losses simulation in the rotor having an high-Tc superconducting field winding using Ag sheathed Bi-2223. The analysis was conducted with an equivalent model of the high-Tc superconducting motor under transition condition during the load that varies from 250watt to 500watt. The simulation results show that the transient state lasts for about 2 seconds, and the ac losses decreased exponentially from the initial value above 2 watts.

  • PDF

고온초전도동기모터의 교류손실에 따른 ?치 해석에 관한 연구 (A Study on the Quench characteristics Analysis considering Ac-Losses of High-Tc Superconducting Synchronous Motor)

  • 윤용수;송명곤;문창욱;홍계원;이상진;고태국
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 1999년도 제1회 학술대회논문집(KIASC 1st conference 99)
    • /
    • pp.93-96
    • /
    • 1999
  • This paper deals with the quench characteristic analysis in high-Tc superconducting synchronous motor of five to six hundred watts capacity. First, the magnetic field distribution and ac losses of high-Tc superconducting motor with the additive flux damper circuit was derived and computer simulation was performed with the equivalent model using FEM. The simulation results show that the quench state lasts for about 0.3 seconds.

  • PDF

철도차량용 매입형 영구자석 동기전동기의 영구자석 와전류 손실 분석 연구 (Analysis of Eddy Current Loss on Permanent Magnets of Interior Permanent Magnet Synchronous Motor for Railway Transit)

  • 박찬배;이형우;이병송;김남포
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.2310-2316
    • /
    • 2011
  • In order to apply Interior Permanet Magnet Synchronous Motor(IPMSM) to the propulsion system of the railway transit, 110 (kW) class IPMSMs with high-power density are designed as a concentrated winding model and a distributed winding model in this study. The concentrated winding model designed in this study is 6 poles/9 slots and the distributed winding model is 6 poles/36 slots. In general, the eddy current losses in the permanent magnets of IPMSM are caused by the slot harmonics. The thermal demagnetization of the magnet by the eddy current losses at high rotational speed often becomes one of the major problems in the IPMSM with a concentrated windings especially. A design to reduce eddy current losses in permanent magnets design is important in IPMSM for the railway vehicle propulsion system which requires high-speed operation. Therefore, a method to devide the permanent magnet is proposed to reduce the eddy current losses in permanent magnet in this study. Authors analyze the variation characteristics of the eddy current losses generated in permanent magnet of the concentrated winding model by changing the number of the division of the permanent magnets.

  • PDF

Power Loss and Junction Temperature Analysis in the Modular Multilevel Converters for HVDC Transmission Systems

  • Wang, Haitian;Tang, Guangfu;He, Zhiyuan;Cao, Junzheng
    • Journal of Power Electronics
    • /
    • 제15권3호
    • /
    • pp.685-694
    • /
    • 2015
  • The power loss of the controllable switches in modular multilevel converter (MMC) HVDC transmission systems is an important factor, which can determine the design of the operating junction temperatures. Due to the dc current component, the approximate calculation tool provided by the manufacturer of the switches cannot be used for the losses of the switches in the MMC. Based on the enabled probabilities of each SM in an arm, the current analytical models of the switches can be determined. The average and RMS currents can be obtained from the corresponding current analytical model. Then, the conduction losses can be calculated, and the switching losses of the switches can be estimated according to the upper limit of the switching frequency. Finally, the thermal resistance model of the switches can be utilized, and the junction temperatures can be estimated. A comparison between the calculation and PSCAD simulation results shows that the proposed method is effective for estimating the junction temperatures of the switches in the MMC.

상호 연관성을 갖는 연속적인 패킷 손실에 대한 TCP 손실 복구 성능 분석 (Performance Analysis of TCP Loss Recovery for Correlated Packet Losses over Wireless Networks)

  • 김범준;김석규;이재용
    • 한국통신학회논문지
    • /
    • 제29권7B호
    • /
    • pp.660-666
    • /
    • 2004
  • 처리율로 대표되는 전반적인 TCP의 성능은 패킷 손실이 발생했을 때 이를 복구하는 과정의 효율성에 의해 크게 좌우된다. 특히, 무선 링크를 통한 전송 과정에서의 비트 오류로 인해 발생하는 비 혼잡 패킷 손실은 TCP의 손실 복구 성능을 크게 저하시키는 문제점이 있다. 본 논문에서는 무선 채널에 존재하는 다중 경로 페이딩(multipath fading)에 의해서 상호 연관성을 가지고 연속적으로 발생하는 패킷 손실(correlated packet Losses)에 대해 TCP 손실 복구 과정의 성능을 모델링을 통해서 분석한다. Markov 프로세스를 이용한 분석 결과를 바탕으로 전체적인 패킷 손실 확률이 매우 낮더라도 패킷 손실의 연속성이 손실 복구 차원에서의 TCP의 성능을 크게 저하시킬 수 있음을 보인다.

고온초전도선재의 교류손실 해석 및 실험 (AC loss analysis and experimental evaluation of a high temperature superconductor)

  • 류경우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.96-100
    • /
    • 2001
  • Bi-2223 tapes have been developed for low-field power applications at liquid nitrogen temperature. When the Bi-2223 tapes are used in an application such as a power transmission cable or a power transformer, they are supplied with an AC transport current and exposed to an external magnetic field generated by neighboring tape's AC currents simultaneously. AC loss taking into account such real applications is a crucial issue for power applications of the Bi-2223 tapes to be feasible. In this paper, the transport losses for different AC current levels and arrangements of the neighboring tapes have been measured in a 1.5 m long Bi-2223 tape. The significant increase of the transport losses due to neighboring tape's AC currents is observed. An increase of the transport losses caused by a decrease of the Bi-2223 tape's critical current is a minor effect. The measured transport losses could not be explained by a dynamic resistance loss based on DC voltage-current characteristics in combination with the neighboring tape's AC currents. The transport losses do not depend on the frequency of the neighboring tape's AC currents but its arrangements in the range of small current especially.

  • PDF

시간가동률 척도에 의한 Lean OEE의 연계지표 개발 및 적용 (Development and Implementation of Chain Metrics for Obtaining Lean Overall Equipment Effectiveness Using Availability Measures)

  • 최성운
    • 대한안전경영과학회지
    • /
    • 제14권2호
    • /
    • pp.147-158
    • /
    • 2012
  • This paper aims to develop a new chain metrics for obtaining lean Overall Equipment Effectiveness(OEE) and present implementation strategy which considers the properties for Total Productive Maintenance(TPM) to reduce machine losses, Performance Analysis and Control(PAC) to reduce labor losses, Lean Production System(LPS) to reduce floor wastes, and Theory of Constraints(TOC) to minimize the problem of Capacity Constrained Resource(CCR). The study reviews the related literatures and reformulates the structure of machine losses, labor losses and field wastes. The research also develops the integrated productivity metrics according to time, units, reliability and maintainability. It is found that the study develops the actual productivity measure in terms of efficiency, effectiveness and standard productivity. In addition to that, it outlines and develops by using the integrated LPS and TPM, lean OEE measures such as Time Based Productivity(TBP), Unit Based Productivity(UBP), and Reliability & Maintainability Based Availability(RMBA). Implication examples are proposed to make it easier and available for practioners to understand the implementation strategies about TPM OEE, lean OEE and TOC OEE. Futhermore related to other studies, the research contributes to create a new chain productivity measures to clear the interrelationship concepts of productivity, efficiency and effectiveness. Moreover the paper develops the enhanced OEE measures by integration of TPM, PAC, LPS and TOC with the perspective of schedule, throughput, reliability, maintainability and availability.

제약조건을 고려한 경제급전 제어를 위한 다단계 최적조류계산 알고리즘 (A Multi-level Optimal Power Flow Algorithm for Constrained Power Economic Dispatch Control)

  • 송경빈
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권9호
    • /
    • pp.424-430
    • /
    • 2001
  • A multi-level optimal power flow(OPF) algorithm has been evolved from a simple two stage optimal Power flow algorithm for constrained power economic dispatch control. In the proposed algorithm, we consider various constraints such as ower balance, generation capacity, transmission line capacity, transmission losses, security equality, and security inequality constraints. The proposed algorithm consists of four stages. At the first stage, we solve the aggregated problem that is the crude classical economic dispatch problem without considering transmission losses. An initial solution is obtained by the aggregation concept in which the solution satisfies the power balance equations and generation capacity constraints. Then, after load flow analysis, the transmission losses of an initial generation setting are matched by the slack bus generator that produces power with the cheapest cost. At the second stage we consider transmission losses. Formulation of the second stage becomes classical economic dispatch problem involving the transmission losses, which are distributed to all generators. Once a feasible solution is obtained from the second stage, transmission capacity and other violations are checked and corrected locally and quickly at the third stage. The fourth stage fine tunes the solution of the third stage to reach a real minimum. The proposed approach speeds up the two stage optimization method to an average gain of 2.99 for IEEE 30, 57, and 118 bus systems and EPRI Scenario systems A through D testings.

  • PDF

고속의 유효전력 최적조류계산 알고리즘 (A Fast Optimization Algorithm for Optimal Real Power Flow)

  • 송경빈;김홍래
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.926-928
    • /
    • 1998
  • A fast optimization algorithm has been evolved from a simple two stage optimal power flow(OPF) algorithm for constrained power economic dispatch. In the proposed algorithm, we consider various constraints such as power balance, generation capacity, transmission line capacity, transmission losses, security equality, and security inequality constraints. The proposed algorithm consists of four stages. At the first stage, we solve the aggregated problem that is the crude classical economic dispatch problem without considering transmission losses. An initial solution is obtained by the aggregation concept in which the solution satisfies the power balance equations and generation capacity constraints. Then, after load flow analysis, the transmission losses of an initial generation setting are matched by the slack bus generator that produces power with the cheapest cost. At the second stage we consider transmission losses. Formulation of the second stage becomes classical economic dispatch problem involving the transmission losses, which are distributed to all generators. Once a feasible solution is obtained from the second stage, transmission capacity and other violations are checked and corrected locally and quickly at the third stage. The fourth stage fine tunes the solution of the third stage to reach a real minimum. The proposed approach speeds up the coupled LP based OPF method to an average gain of 53.13 for IEEE 30, 57, and 118 bus systems and EPRI Scenario systems A through D testings.

  • PDF