• Title/Summary/Keyword: Losses

Search Result 5,298, Processing Time 0.526 seconds

동기 정류기를 이용한 고효율 역률보상형 AC/DC 컨버터 (High Efficiency PFC AC/DC Converter with Synchronous Rectifier)

  • 박한웅
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.266-269
    • /
    • 2000
  • This paper presents a novel single-stage unity power factor converter which features the reduced switching losses by zero-voltage switching and zero-current switching (ZVZCS). Hence the turn-on and turn-off losses of switches are sufficiently reduced. And the reduced conduction losses are achieved by the elimination of one leg of front-end rectifier. And low on-resistance MOSFETs (Synchronous Rectifier) are used in the rectifier at the secondary side of high frequency transformer instead of diodes. Theoretical analysis simulated results of a AC to DC 150W(5V, 30A) converter are presented.

  • PDF

적층형 필라멘트와 방사형 필라멘트 구조를 갖는 원형 초전도선의 결합손실 (Coouping Losses of the Round HTS Wires with Stacked Filaments and Radial Filaments)

  • 신정욱;차귀수;이지광;한송엽
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제2권1호
    • /
    • pp.40-44
    • /
    • 2000
  • The round HTS wire is easier to handle than the rectangular HTS tape. This paper describes the coupling losses of the round HTS wires by finite element method. Effect of the round HTS wire are considered. Two types of Filaments arrangement, stacked filament and radial filaments, are considered. Calculation results show that coupling losses of the round HTS wire vary only a little with the direction of external magnetic field.

  • PDF

손실배분계수를 이용한 송전선로 유효전력 손실의 배분법 (A Method to Allocate Real Power Losses of Transmission Lines using Loss Distribution factors)

  • 노경수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1259-1261
    • /
    • 1999
  • The paper proposes a simple method to calculate the portion of real power losses allocated to individual loads. The method is implemented by loss distribution factors, and analyses the share of loads in transmission line losses. Effectiveness of the algorithm is verified by a computer simulation. The results can be used to compute the cost of ancillary services under deregulated environment in electric power industries.

  • PDF

다이오드 역방향 회복에 의한 손실을 감소시킨 부스트 컨버터 (A Technique for Reducing Diode Reverse-Recovery-Related Losses in Boost converters)

  • 송기승;이종규;이성백
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.1857-1859
    • /
    • 1998
  • This paper proposes a circuit technique that reduces losses cauased by reverse-recovery characteristics of the diode in converters. In high voltage, high power, Reverse recovery characteristics of the diode gives large stresses to switching devices. To solve the problem, we propose a circuit with active snubber between diode and switch. By controling di/dt rate of thr diode, the proposed technique reduces the losses and the stresses of switching devices.

  • PDF

찰손을 고려한 동기형 릴럭턴스 전동기의 유한요소해석 (Finite Element Analysis of Synchronous Reluctance Motor Considering Iron Core Loss)

  • 이중호;김정철;현동석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.55-57
    • /
    • 1998
  • A finite element analysis for a synchronous reluctance motor (SynRM) is presented with emphasis on the effect of saturation and iron losses. Preisachs model, which allows accurate prediction of iron losses, is adopted in this procedure to provide a nonlinear solution. This technique provide significant properties of proposed SynRM under the magnetic saturation and iron losses effect.

  • PDF

An Effective Carrier-Based Modulation Strategy to Reduce the Switching Losses for Indirect Matrix Converters

  • Tran, Quoc-Hoan;Lee, Hong-Hee
    • Journal of Power Electronics
    • /
    • 제15권3호
    • /
    • pp.702-711
    • /
    • 2015
  • In this paper, an effective carrier-based modulation (CBM) strategy to reduce the switching losses for indirect matrix converters (IMCs) is presented. The discontinuous pulse width modulation method is applied to decrease the switching numbers in one carrier cycle, and an optimum offset voltage is selected to avoid commutations of the high output phase currents. By decreasing the switching numbers along with avoiding commutation of the high currents, the proposed CBM strategy significantly reduces the switching losses in IMCs. In addition, the proposed CBM strategy is independent of load conditions, such as load power and power factor, and it has good performance in terms of the input/output waveforms. Simulation and experimental results are provided to verify the effectiveness of the proposed CBM strategy.

직사각형 맨홀의 내부형상변화에 따른 흐름특성 분석 (An Analysis of Flow Characteristics with Changing the Inside Shapes in Square Manhole)

  • 장석진;윤영노;김정수;윤세의
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2007년도 정기총회 및 학술발표대회
    • /
    • pp.199-202
    • /
    • 2007
  • In storm sewer networks a lot of manholes are installed to maintain and connect a sewer of urban area. There are some shapes of manhole such as circular type, square type, and so on. Square shape manholes are installed to connect the large diameter drainage pipes in general and have lager head losses than circular one. Consequently, it is important to analyze the head losses in square manhole because the head losses in square manhole are much bigger than the friction losses in pipes. Hydraulic experimental apparatus which can be changed the inside shape in square manhole was installed for this study. The experimental discharge was $16{\ell}/sec$. The head loss coefficients in the manhole were calculated by the experimental results. The range of head loss coefficients in the general square manhole were from 0.33 to 0.48 and the range of head loss coefficients in the square manhole changed inside shape were from 0.23 to 0.28.

  • PDF

소형 터보펌프에 대한 실험적 평가와 성능해석 (Experimental Evaluation and Performance Analysis for a Mini Turbo-pump)

  • 김수원;박무룡;황순찬;오형우;윤의수
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.54-60
    • /
    • 2002
  • A mini turbo-pump having 44mm diameter impeller for hydraulic power control have been tested to evaluate hydraulic performance and losses. The characteristics of the losses such as mechanical, friction, balancing rib losses were investigated. The investigation revealed that the friction loss is relatively large but the balancing rib loss small. It was found that the hydraulic efficiency of the pump at design point is very low($27\%$) due to low specific speed and large friction losses. A computational fluid dynamics(CFD) method also has been utilized for performance prediction of the mini turbo-pump to compare the computed results with the test data.

  • PDF

능동 클램프형 포워드 DC-DC 컨버터의 효율에 관한 연구 (A Study on Efficiency of Active Clamp Type Forward DC-DC Converter)

  • 안태영
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권5호
    • /
    • pp.351-357
    • /
    • 2004
  • In this paper, we present an analytical method that provides fast and efficient evaluation of the conversion efficiency for switching power supplies. In the proposed method, the conduction losses are evaluated by calculating the effective values of the ideal current waveform first and incorporating them into an exact equivalent circuit model of the switching power supply that includes all the parasitic resistances of the circuit components. While the winding losses and core losses are accurately accounted for the magnetic components, the skin and proximity effects are assumed to be negligible in order to simplify the analysis. The validity and accuracy of the proposed method are verified with experiments on a prototype active-clamped forward converter with synchronous rectification. An excellent correlation between the experiments and theories are obtained for the input voltages of 36-75 V with 4-6 MOSFETs employed for the synchronous rectification.

운전조건을 고려한 고속 영구자석형 동기전동기의 회전자 손실 해석 (Analysis on the Rotor Losses in High-Speed Permanent Magnet Synchronous Motor Considering the Operating Condition)

  • 장석명;최장영;조한욱
    • 전기학회논문지
    • /
    • 제56권1호
    • /
    • pp.48-56
    • /
    • 2007
  • In this paper, the rotor losses in high-speed permanent synchronous motor (PMSM) considering the operating condition are discussed. In order to maintain the mechanical integrity of a high-speed permanent magnet machine rotor intended for high-speed operation, the rotor assembly is often retained within a stainless steel or Carbon-Fiber/Epoxy sleeve. The sleeve is exposed to fields produced by the stator from either the slotting or the mmf harmonics that are not synchronous with rotor losses. On the basis of analytical field analysis, the rotor losses are analyzed. In particular, the no-load, rated with air-cooled, and forced water cooled conditions are considered. The results are validated extensively by comparison with non-linear finite element method (FEM).