Application Optimal Reconfiguration Algorithm for Distribution Power System to KEPCO System (배전계통 최적 재구성 알고리즘의 실계통 적용)

  • Seo, Gyu-Seok;Baek, Young-Sik;Kim, Jung-Nyun;Chae, Woo-Gyu
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.125-127
    • /
    • 2008
  • This paper shows application of optimal reconfiguration algorithm for distributing power system to KEPCO(Korea Electric Power Corporation) system for loss minimization and load balancing. That is, it suggests additional algorithm to check potential problems caused in case of theoretical algorithm being applied to real system and recover from them. Also, comparing the results of reconfiguration algorithm Tabu-Search Algorithm applied to current KEPCO distribution power system and those of Branch Exchange Algorithm using initial operation point suggested in this paper, it shows how much the results are improved in aspects of load balancing, loss reduction and calculating time.

  • PDF

Analysis on the Temperature Distribution for the Billet in a Furnace (가열로내 피열재의 온도분포 해석)

  • Kwon, O.B.;Kim, M.K.;Chang, K.Y.;Kwon, H.C.;Bae, D.S.
    • Journal of Power System Engineering
    • /
    • v.8 no.2
    • /
    • pp.24-30
    • /
    • 2004
  • In this paper, the optimal heating pattern of the furnace is sought to reduce the unnecessary energy loss. A finite difference method was used to estimate the transient temperature field of the billet in a furnace. Heat conduction equations were used in the interior nodes of the billet, while energy balances for conduction, convection, and radiation were considered in the boundary nodes. Several heating patterns for the furnace were tested and subsequently compared each other. The results showed that the temperature in the preheating zone should be set to relatively low. The temperature distributions of the billet are quite different from each other when different heating pattern are used, even though the heating patterns have the same amount of energy consumption. It reveals that there exists an optimal heating pattern to save the energy loss.

  • PDF

Bootstrap Simulation for Performance Evaluation of Optical Multifiber Connectors (붓스크랩 기법을 이용한 다심 광커넥터 손실특성 예측)

  • 전오곤;강기훈
    • Journal of Korean Society for Quality Management
    • /
    • v.26 no.4
    • /
    • pp.250-264
    • /
    • 1998
  • The purpose of the thesis is to develop simulation program for forecasting of optical connector. So we can achieve the time and the money saving for making the optical connector. Optical performance (insertion loss) of optical connector mainly relies on 3 misalignment factors-ferrule factor due to mis-manufacture from design, auto-centering effect that is fiber behavior phenomena between hole and fiber, fiber misalignment factor. Simulation use experimental data with auto-centering effect and fiber factor and use pseudo data with ferrule through random number generation because it is developing stage. In this study we a, pp.y kernel density estimation method with experimental data in order to know whether it belong to or not specific parametric distribution family. And we simulate to forecast insertion loss of optical multifiber connector under specific design model using nonparametric bootstrap resampling data and parametric pseudo samples from uniform distribution. We obtain the tolerance specifications of misalignment factors satisfying not exceed in maximum 1.0dB and choose optimal hole diameter.

  • PDF

Optimal Routing for Distribution System Planning using heuristic strategy (휴리스틱 탐색전략을 이용한 배전계통 계획의 최적경로탐색)

  • Choi, Nam-Jin;Kim, Byung-Seop;Shin, Joong-Rin;Chae, Myung-Suk
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.142-146
    • /
    • 2000
  • This paper Presents a heuristic algorithm based on branch exchange method to solve ORP (Optimal Routing Problem) for distribution system planning. The ORP is a complex task which is generally formulated as a combinatorial optimization problem with various constraints. The cost function of ORP is consisted of the investment cost and the system operation cost that is generally expressed with system power loss. This paper also adopt an specialy designed selection method of maximum loss reduction loop and branch to reduce optimization time. The effectiveness of the proposed algorithm was shown with 32, 69 bus example system.

  • PDF

SOME POINT ESTIMATES FOR THE SHAPE PARAMETERS OF EXPONENTIATED-WEIBULL FAMILY

  • Singh Umesh;Gupta Pramod K.;Upadhyay S.K.
    • Journal of the Korean Statistical Society
    • /
    • v.35 no.1
    • /
    • pp.63-77
    • /
    • 2006
  • Maximum product of spacings estimator is proposed in this paper as a competent alternative of maximum likelihood estimator for the parameters of exponentiated-Weibull distribution, which does work even when the maximum likelihood estimator does not exist. In addition, a Bayes type estimator known as generalized maximum likelihood estimator is also obtained for both of the shape parameters of the aforesaid distribution. Though, the closed form solutions for these proposed estimators do not exist yet these can be obtained by simple appropriate numerical techniques. The relative performances of estimators are compared on the basis of their relative risk efficiencies obtained under symmetric and asymmetric losses. An example based on simulated data is considered for illustration.

Lindley Type Estimators with the Known Norm

  • Baek, Hoh-Yoo
    • Journal of the Korean Data and Information Science Society
    • /
    • v.11 no.1
    • /
    • pp.37-45
    • /
    • 2000
  • Consider the problem of estimating a $p{\times}1$ mean vector ${\underline{\theta}}(p{\geq}4)$ under the quadratic loss, based on a sample ${\underline{x}_{1}},\;{\cdots}{\underline{x}_{n}}$. We find an optimal decision rule within the class of Lindley type decision rules which shrink the usual one toward the mean of observations when the underlying distribution is that of a variance mixture of normals and when the norm ${\parallel}\;{\underline{\theta}}\;-\;{\bar{\theta}}{\underline{1}}\;{\parallel}$ is known, where ${\bar{\theta}}=(1/p){\sum_{i=1}^p}{\theta}_i$ and $\underline{1}$ is the column vector of ones.

  • PDF

Lindley Type Estimation with Constrains on the Norm

  • Baek, Hoh-Yoo;Han, Kyou-Hwan
    • Honam Mathematical Journal
    • /
    • v.25 no.1
    • /
    • pp.95-115
    • /
    • 2003
  • Consider the problem of estimating a $p{\times}1$ mean vector ${\theta}(p{\geq}4)$ under the quadratic loss, based on a sample $X_1,\;{\cdots}X_n$. We find an optimal decision rule within the class of Lindley type decision rules which shrink the usual one toward the mean of observations when the underlying distribution is that of a variance mixture of normals and when the norm $||{\theta}-{\bar{\theta}}1||$ is known, where ${\bar{\theta}}=(1/p)\sum_{i=1}^p{\theta}_i$ and 1 is the column vector of ones. When the norm is restricted to a known interval, typically no optimal Lindley type rule exists but we characterize a minimal complete class within the class of Lindley type decision rules. We also characterize the subclass of Lindley type decision rules that dominate the sample mean.

  • PDF

CFD Analysis on a Flow Channel of a Bipolar Plate with Varying Cross-sectional Area in a PEM Fuel Cell (PEM 연료전지용 Bipolar Plate의 변화단면 유로에 대한 CFD 해석)

  • Yang, Dong-Jin;Park, Woon-Jean
    • New & Renewable Energy
    • /
    • v.3 no.3
    • /
    • pp.14-19
    • /
    • 2007
  • A flow channel model of a bipolar plate with varying cross-sectional area was newly designed for improving performance and efficiency of a PEM fuel cell stack. As a result, the varying cross-sectional area model showed poor uniformity in velocity distribution, however, maximum velocity in the flow path is about 30% faster than that of the uniform cross-sectional area model. The proposed varying cross-sectional area model is expected to diffuse operating fluids more easily into diffusion layer because it has relatively higher values in pressure distribution compared with other flow channel models. It is expected that the implementation of the varying cross-sectional area model can reduce not only the mass transport loss but also the activation loss in a PEM fuel cell, and open circuit voltage of a fuel cell can thus be increased slightly.

  • PDF

Lindley Type Estimators When the Norm is Restricted to an Interval

  • Baek, Hoh-Yoo;Lee, Jeong-Mi
    • Journal of the Korean Data and Information Science Society
    • /
    • v.16 no.4
    • /
    • pp.1027-1039
    • /
    • 2005
  • Consider the problem of estimating a $p{\times}1$ mean vector $\theta(p\geq4)$ under the quadratic loss, based on a sample $X_1$, $X_2$, $\cdots$, $X_n$. We find a Lindley type decision rule which shrinks the usual one toward the mean of observations when the underlying distribution is that of a variance mixture of normals and when the norm $\parallel\;{\theta}-\bar{{\theta}}1\;{\parallel}$ is restricted to a known interval, where $bar{{\theta}}=\frac{1}{p}\;\sum\limits_{i=1}^{p}{\theta}_i$ and 1 is the column vector of ones. In this case, we characterize a minimal complete class within the class of Lindley type decision rules. We also characterize the subclass of Lindley type decision rules that dominate the sample mean.

  • PDF

The Effects of Harmonic Current in the Operating Characteristics of High Temperature Superconducting Cable (고조파가 고온 초전도 케이블의 운전특성에 미치는 영향)

  • Lee, Geun-Joon;Lee, Jong-Bae;Hwang, Si-Dole;Sohn, Song-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.12
    • /
    • pp.2065-2071
    • /
    • 2007
  • This paper suggests the harmonic effects on HTS(High Temperature Superconducting) power cable. HTS cable is regarded as not only one of the important countermeasure to supply high density power demand area, but also one of countermeasures greenhouse technology. However, with the development of digital society, the distribution line power is much contaminated with harmonics generated by various power electronic equipments. This paper describes how the HTS cable responds to the harmonic and increases AC losses caused by hysteresis phenomenon. EMTDC based harmonic simulation results are compared with AC loss measured values.