• 제목/요약/키워드: Loss Separation Method

검색결과 105건 처리시간 0.025초

속이 빈 원관에서 1차원적인 열전달 해석의 오차 (Errors in One-Dimensional Heat Transfer Analysis in a Hollow Cylinder Feedwater Pipe)

  • 강형석
    • 대한기계학회논문집B
    • /
    • 제20권2호
    • /
    • pp.689-696
    • /
    • 1996
  • A comparison is made of the heat loss from a hollow cylinder, computed using an one-dimensional analytic method and a two-dimensional separation of variables scheme. For a two-dimensional analysis, the temperature of the inner surface as a boundary condition can be varied along the length of the cylinder by varing the temperature variation factor, b. Comparisons of the heat loss from the hollow cylinder using these two methods are given as a function of non-dimensional cylinder length, the ratio of the outer radius to the inner radius, temperature variation factor and Biot number. The result shows that the value of the heat loss from the hollow cylinder obtained using the one-dimensional analytic method becomes close to the value given by the two-dimensional separation of variables scheme as the value of Biot number and the non-dimensional hollow cylinder length increase and as the ratio of the outer radius to the inner radius decreases.

파일 방파제의 소파성능 해석 (Analysis on Wave Absorbing Performance of a Pile Breakwater)

  • 조일형;고혁준
    • 한국해양공학회지
    • /
    • 제21권4호
    • /
    • pp.1-7
    • /
    • 2007
  • Based on the eigenfunction expansion method, the wave-absorbing performance of a square or circular pile breakwater was investigated. Flow separation resulting from sudden contraction and expansion is generated and is the main cause of significant energy loss. Therefore, evaluation of an exact energy loss coefficient is critical to enhancing the reliability of the mathematical model. To obtain the energy loss coefficient, 2-dimensional turbulent flow is analyzed using the FLUENT commercial code, and the energy loss coefficient can be obtained from the pressure difference between upstream and downstream. It was found that energy loss coefficient of circular pile is 20% that of a square pile. To validate the fitting equation for the energy loss coefficient, comparison between the analytical results and the experimental results (Kakuno and Liu, 1993) was made for square and circular piles with good agreement. The array of square piles also provides better wave-absorbing efficiency than the circular piles, and the optimal porosity value is near P=0.1.

Optimization of a 3-D Thermally Asymmetric Rectangular Fin

  • 강형석
    • Journal of Mechanical Science and Technology
    • /
    • 제15권11호
    • /
    • pp.1541-1547
    • /
    • 2001
  • The non-dimensional fin length for optimum heat loss from a thermally asymmetric rectangular fin is represented as a function of the ratio of the bottom surface Biot number to the top surface Biot number, fin tip surface Biot number and the non-dimensional fin width. Optimum heat loss is taken as 98% of the maximum heat loss. For this analysis, three dimensional separation of variables method is used. Also, the relation between the ratio of the bottom surface Biot number to the top surface Biot number and the ratio of the right surface Biot number to the left surface Biot number is presented.

  • PDF

사각 환형 핀에 대한 1차원과 2차원 해석의 열전달 비교 (Comparison of Heat Transfer Between 1-D and 2-D Analyses for a Rectangular Annular Fin)

  • 강형석
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1177-1181
    • /
    • 2009
  • Heat loss from a convective rectangular profile annular fin with variable inside fluid heat transfer coefficient and fin height is calculated by using both the one dimensional analytic method and two dimensional variables separation method. Heat loss from the two dimensional method and the relative error of heat loss between the one dimensional method and two dimensional method are presented as a function of the fin length, ambient convection characteristic number and fin height. One of the results shows that the relative error of heat loss between one dimensional method and two dimensional method is within 0.7% in the range of given parameters in this study.

  • PDF

가스발생기를 이용한 분리 메카니즘 성능예측 기법 (Performance Prediction Method of Separation Mechanism by using a Gas Generator)

  • 오석진;이도형;김상화;김기언
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년도 제31회 추계학술대회논문집
    • /
    • pp.199-202
    • /
    • 2008
  • 본 논문에는 가스발생기와 분리장치 종류 중 하나인 가스푸셔의 내부 유동장 설명을 통한 수학적-물리적 모델이 기술되었다. 실험적 상수인 열손실계수와 마찰계수는 시험에 의해 결정되었다. 그레인 형상설계에 기초한 가스발생기와 가스푸셔 내부의 연소과정, 유동과 피스톤 거동이 수치해석적 방법으로 시뮬레이션 되었다. 개발된 예측기법은 향후 분리 메카니즘 시스템 설계 시에 유용하게 사용될 수 있을 것이다.

  • PDF

0.75[kW]급 삼상유도전동기 효율의 불확도 평가에 관한 연구 (Study on the Evaluation of Uncertainty for the Efficiency of 0.75[kW] Class Three Phase Induction Motor)

  • 전희득;박한석;김대경;우경일
    • 전기학회논문지
    • /
    • 제64권4호
    • /
    • pp.653-659
    • /
    • 2015
  • In the last few years, the regulations for efficiency grade of the three phase induction motor are internationally being discussed and upgraded for the protection of environment and energy saving. So the efficiency improvement and the reliable test result are essential to determine the premium grade three phase induction motor. While a study on developing the efficiency motor is active, there is little research about the guarantee for efficiency. So in this paper, the dispersion characteristic of the efficiency is studied using uncertainty theory for the three phase induction motor to improve the reliability of efficiency. The values such as input voltage, current, speed, torque were obtained by loss separation method to evaluate the uncertainty. From the result, it was known that the important loss factor could affect the uncertainty is the stray loss.

수학적 이론을 이용한 이차원 곡면 덕트의 최적형상 설계 (Optimal Shape Design of a 2-D Curved Duct Using a Mathematical Theory)

  • 임석현;최해천
    • 대한기계학회논문집B
    • /
    • 제22권9호
    • /
    • pp.1325-1334
    • /
    • 1998
  • The objectives of the present study are to develop a systematic method rather than a conventional trial-and-error method for an optimal shape design using a mathematical theory, and to apply it to engineering problems. In the present study, an optimal condition for a minimum pressure loss in a two-dimensional curved duct flow is derived and then an optimal shape of the curved duct is designed from the optimal condition. In the design procedure, one needs to solve the adjoint Navier-Stokes equations which are derived from the Navier-Stokes equations and the cost function. Therefore, a computer code of solving both the Navier-Stokes and adjoint Navier-Stokes equations together with an automatic grid generation is developed. In a curved duct flow, flow separation occurs due to an adverse pressure gradient, resulting in an additional pressure loss. Optimal shapes of a curved duct are obtained at three different Reynolds numbers of 100, 300 and 800, respectively. In the optimally shaped curved ducts, the separation region does not exist or is significantly reduced, and thus the pressure loss along the curved duct is significantly reduced.

The Iron loss Estimation of IPMSM According to Current Phase Angle

  • Cho, Gyu-Won;Kim, Dong-Yeong;Kim, Gyu-Tak
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1345-1351
    • /
    • 2013
  • Variable iron loss as function of current phase angle of Interior Permanent Magnet Synchronous Motor(IPMSM) was calculated through Curve Fitting Method(CFM). Also, a magnetic flux density distribution of iron core according to current phase angle was analyzed, and an iron loss calculation was performed including harmonic distortion. The experiment was performed by production of non-magnetizing model for the separation of mechanical loss, and the iron loss was calculated by the measurement of input using power analyzer and output power using dynamometer. Some error was generated between experimental results and calculation value, but an iron loss diminution according to current phase angle followed a same pattern. So, errors were generated by measurement, vibration, noise, harmonic distortion loss, etc.

심랭식공기분리공정에서 질소증류탑의 엑서지 해석 (Exergy Analysis of Nitrogen Distillation Column in the Cryogenic Air Separation Process)

  • 용평순;이성철
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권1호
    • /
    • pp.145-150
    • /
    • 2002
  • The distillation column is one of large energy consumable units in the cryogenic air separation process and the accurate energy analysis of this unit is necessary for choice of energy saving process. In this work, the energy method was adopted for energy analysis of a cryogenic nitrogen distillation column. In order to designing the energy saving distillation column, the exergy distribution of feed air, exergy efficiency and exergy loss for process condition was investigated and the optimal process condition to minimize the exergy loss was found. The result from this work can be used as a guideline for the choice of the process design conditions and efficiency improvement of cryogenic distillation column.

자력선별법을 이용한 화력 발전소 매립회의 지오폴리머 원료화 연구 (The study of geopolymer utilization of reclaimed ash by using magnetic separation method)

  • 김강덕
    • 한국결정성장학회지
    • /
    • 제27권5호
    • /
    • pp.249-255
    • /
    • 2017
  • 화력발전소에서 발생되는 매립회의 지오폴리머 원료화를 위하여 자력선별 공정을 이용하여 자성체와 비자성체로 분리하였으며, 매립회의 입도 및 자석의 세기에 따른 미연탄소의 선별 특성을 관찰하였다. 3000 G 자석을 이용한 세립(0.15~0.84 mm)과 조립(0.84~2.4 mm) 매립회의 자력선별 결과, 매립회는 입도에 상관없이 비자성체의 무게분율과 강열감량이 자성체보다 높게 나타났으며, 세립 매립회의 경우 자석의 세기를 3000 G에서 10000 G로 증가시키면, 약한 자성을 띠는 물질들도 자성체로 분리됨에 따라 자성체의 무게 분율이 급격히 증가되면서 낮은 강열감량에도 불구하고 전체 강열감량의 32.6 wt%의 66.9 %(22.8 wt%)를 차지하였다. 자력 선별된 조립 매립회로 제조된 지오폴리머의 재령일별 압축강도 측정결과, 미연탄이 적게 포함된 자성체로 제조된 지오폴리머의 압축강도가 20 MPa를 나타내었다.