An Analysis of Intake System using BEM and 1-D Solution (경계 요소법과 평면파 이론을 이용한 흡기계 해석)

  • Lee, C.M.;Kwon, O.S.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.3 no.1
    • /
    • pp.89-96
    • /
    • 1995
  • The application of the 4-pole parameter method with 1 - D theory is acceptable for intake system analysis. However, the limitaion appears during the analysis of complicated intake system since this method is developed based on the plane wave thoery. For the intake system analysis, the usage of BEM(Boundary Element Method) is introduced describing its disadvantage. To combine benefits of both method. a hybrid method is introduced. This hybrid method consists of the 4-pole parameter with I-D theory and BEM. The developed method is applied to an automobile intake system analysis to obtain the transmission loss.

  • PDF

Experimental Study On Power Flow Analysis of Vibration of a Coupled Plate (연성 평판 진동에 대한 파워흐름해석법의 실험적 연구)

  • Lee, G.H.;Kil, H.G.;Hwang, S.G.;Hong, S.Y.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.797-800
    • /
    • 2006
  • The power flow analysis(PFA) can be effectively used to predict structural vibration in medium-to-high frequency ranges. In this paper, vibration experiment has been performed to observe the analytical characteristics of the power flow analysis of the vibration of a plate. In the experiment, the loss factor of the plate and the input mobility at a source point have been measured. The data for the loss factor has been used as the input data to predict the vibration of the plate with PFA. The frequency response functions have been measured over the surface of the plate. The comparison between the experimental results and the predicted results for the frequency responsefunctionshasbeenperformed.

  • PDF

Analysis of Mechanical Fixation Made of Aluminum Alloy in an Axial Flux Permanent Magnet Machine

  • Lee, Jiyoung;Park, Byounggung;Koo, Daehyun
    • Journal of Magnetics
    • /
    • v.19 no.3
    • /
    • pp.309-313
    • /
    • 2014
  • This paper presents an eddy current loss analysis of a Mechanical Fixation (MF) made of 6061 aluminum alloy, which is used for an NS type double-rotor single-stator axial flux permanent magnet machine. The prototype MF made of aluminum alloy shows good mechanical performance, but poor electro-magnetic performance, since the machine's efficiency can decrease because of eddy current loss in the MF. In order to prevent efficiency decrease, a modification of the MF structure is also introduced. Three-dimensional finite element analysis (FEA) is used for magnetic field analysis, and eddy current losses are computed. The analysis results are compared to, and verified by the test results.

Voltage Stability Analysis considering Static Voltage Dependent Load Model and Loss Redistribution (손실재분배와 정적전압의존형 부하모델을 고려한 전압안정도 해석)

  • Kim, K.S.;Chae, M.S.;Shin, J.R.;Lim, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.215-217
    • /
    • 1997
  • In many conventional analysis of voltage stability the effect of load characteristics is ignored. But in the real system the load is composed of various components. Therefore if the load composition could be modeled then it will plays an important role in the analysis of static voltage stability. And also, if the system loss generally imposed to slack bus in the conventional load flow calculation is redistributed to each generator the accuracy of static voltage stability analysis can be improved. This paper presents the effect of load composition in the analysis of system stability as well the loss redistribution algorithm. And this paper will compare the result of conventional method with that of the proposed method.

  • PDF

Thermal Network Analysis of Interior Permanent Magnet Machine (매입형 영구자석 전동기의 열 등가 회로 해석)

  • Lim, Jae-Won;Seo, Jang-Ho;Lee, Sang-Yub;Jung, Hyun-Kyo
    • Proceedings of the KSR Conference
    • /
    • 2009.05b
    • /
    • pp.527-532
    • /
    • 2009
  • Recently, Interior Permanent Magnet Machine(IPM) is widely used for traction motor in the high speed train. Due to the high efficiency and high power density of the IPM, it has lots of heat sources such as iron loss and copper loss. These heat sources can cause the demagnetization of permanent magnet, losses in output power and even irreversible defect of the IPM. To prevent the power loss caused by heat sources, the accurate thermal analysis has to be carried out. For the thermal analysis of the IPM, the thermal network is designed for this traction motor. The thermal analysis has executed at rated speed operation. The result of thermal network analysis can be used for the IPM design process.

  • PDF

Some Insights into the Basic QA/QC for the Greenhouse Gas Analysis: Methane and Carbon Dioxide (온실가스 기기분석의 정도관리를 위한 고려사항 연구 - CH4과 CO2를 중심으로 -)

  • Jeong, Jae-Hak;Lim, Ho-Soo;Kim, Ki-Hyun;Bae, Wi-Sup;Jeon, Eui-Chan
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.5
    • /
    • pp.712-718
    • /
    • 2006
  • In order to investigate the analytical uncertainties associated with sampling and analysis of major greenhouse gaseous pollutants(carbon dioxide and methane), we attempted to quantify their adsorptive loss due to the contact with the container wall(such as Tedlar bag and vial). Using the GC/FID method, some basic experimental parameters(such as reproducibility and method detection limit) have been evaluated as part of the essential QA/QC The reproducibilities of carbon dioxide and methane were estimated as 2.02 and 0.2%, respectively. In addition, method detection limits were measured as 0.61 and 0.06 ng, respectively. A test of sample loss rate has also been made for Tedlar bag and vial by assessing the absolute amount of sample loss on the wall. By transferring the samples contained in Tedlar bag to various sizes of Tedlar bags, we measured differences in the absolute loss quantity due to such transfer. In addition, we also examined such loss mechanism as a function of elapsed time and light penetration rate for vial. As results, carbon dioxide and methane have shown about 2% of sample loss due to such contact. It is also noticed that the amount of loss with vial surface is lower than that of Tedlar bag. Therefore, field collection of greenhouse gases using various container types should be made more cautiously to minimize the possibility of sample loss and bias related to such loss.

Core Loss Analysis of Non-oriented Electrical Steel Under Magnetic Induction Including Higher Harmonics

  • Cho, Chuhyun;Son, Derac;Cho, Youk
    • Journal of Magnetics
    • /
    • v.6 no.2
    • /
    • pp.66-69
    • /
    • 2001
  • The actual magnetic induction waveform of cores in electrical machines is not sinusoidal i.e. higher harmonics are always included. Thus the core loss in actual electrical machines is different from the core loss which is measured by the standard method, because the waveform of magnetic induction should be sinusoidal in the standard testing method. Core loss analysis under higher harmonic induction is always important in electric machine design. In this works we measured the core loss when a hysteresis loop has only one period of an ac minor loop of higher harmonic frequency, depending on the position of the ac minor loop of relative to the fundamental harmonic frequency. From this experiment, the core loss P(B/sub 0/f/sub 0/, B/sub h/, nf/sub 0/)) under a higher harmonic magnetic induction B/sub h/ could be expressed by the linear combination the core loss at fundamental harmonic frequency P/sub c/(B/sub 0/, f/sub 0/), the core loss of ac minor loop at zero induction region of the major hysteresis loop P/sub cL/ (B/sub h/, nf/sub 0/), and the core loss of an ac minor loop in the high induction region of the major hysteresis loop P/sub cH/ (B/sub h/, nf/sub 0/) i.e., P/sub c/, (B/sub 0/, f/sub 0/, B/sub h/, nf/sub 0/)=P/sub c/ (B/sub 0/, f/sub 0/,)+(n-1)[k₁(B/sub 0/) P/sub cL/ (B/sub h/, nf/sub 0/)+(1-k₁(B/sub 0/)) P/sub cH/ (B/sub h/, nf/sub 0/)]. This will be useful formula for electrical machine designers and one of effective methods to predict core loss including higher harmonic induction.

  • PDF

Operational Risk Measurement of Financial Institutions via AHP (AHP 분석을 이용한 금융기관 운영리스크 측정)

  • Choi, Seung-Il
    • Korean Management Science Review
    • /
    • v.28 no.3
    • /
    • pp.73-82
    • /
    • 2011
  • Basel II advanced measurement approaches for operational risk need to estimate the frequency and severity distribution of operational losses. Due to lack of internal loss data, the estimation is impossible in many cases and so external loss data might be used by scaling on asset or gross income. To get around lack of loss data, scenario analysis combined with loss distribution approach can be useful in calculating the capital charge of operational risk. However, scenario based loss distribution approach requires much time and effort. Instead we may apply the analytic hierarchy process to measure operational risk of financial institutions. The analytic hierarchy process combined with loss distribution approach is to estimate the capital charge of operational risk in other areas based on the operational VaR in an area with sufficient loss data. AHP provides a tool for timely measurement of operational risk in this rapidly changing global environment.

Loss characteristics analysis of HTS DC cable using FEM (FEM을 이용한 초전도 직류 케이블의 손실 특성 분석)

  • Kim, Sung-Kyu;Kim, Seok-Ho;Kim, Jin-Geun;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.822-823
    • /
    • 2011
  • The authors analyzed harmonic current based loss of a high temperature superconducting (HTS) DC model cable. The loss in HTS DC cable is generated due to the variation of magnetic field caused by harmonic current in a HVDC transmission system. The authors designed and fabricated two meters of HTS DC model cable for verification of real loss characteristic. In this paper, the loss characteristics caused by harmonic current in the HTS DC model cable are analyzed using commercial finite element method software package. The loss of the HTS DC cable is much less than the loss of the HTS AC cable but the loss should be considered to decide a proper capacity of cooling system.

  • PDF

Numerical Analysis on Iron Loss and PM Loss of Permanent Magnet Synchronous Motor Considering the Carrier Harmonics

  • Lee, Dongsu;Kim, Yong-Jae;Jung, Sang-Yong
    • Journal of Magnetics
    • /
    • v.18 no.2
    • /
    • pp.216-219
    • /
    • 2013
  • In this paper, the influence of inverter switching harmonics on iron loss and PM loss of Permanent Magnet Synchronous Motor (PMSM) is numerically investigated by Finite Element Method (FEM). In particular, nonlinear FEM is applied for a multi-layered PM Synchronous Motors (PMSMs), Interior buried PMSM (IPMSM) and PM assisted Synchronous Reluctance Motor (PMa-SynRM), which are adoptively designed and compared for Electric Vehicle (EV) propulsion. In particular, iron loss and PM eddy-current loss under the real current waveform including the carrier harmonics from inverter switching are numerically analyzed with nonlinear FEM by considering the skewed stator structure employed for minimizing spatial harmonics.