• Title/Summary/Keyword: Loop-pipe

Search Result 167, Processing Time 0.033 seconds

Design Optimization of a Compressor Loop Pipe using Response Surface Method (반응표면법을 이용한 압축기 루프 파이프의 최적 설계)

  • 강정환;박종찬;김좌일;왕세명;정충민
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.404-409
    • /
    • 2004
  • A compressor loop pipe is the most important part in a refrigerator from the view of structural vibration and noise. Vibration energy generated from a compressor's inner body is transmitted to the shell and outside through the loop pipe. For this reason it is very important to design a compressor loop pipe. But, for geometrical complexity and dynamic nonlinearity of the loop pipe, analysis and design of the loop pipe is very difficult. So the statistical and experimental methods have to be used for design of this system. The response surface method (RSM) becomes a popular meta-modeling technique f3r the complex system as this loop pipe. As starting point of loop pile's optimization, FEA model and simple experimental model are used instead of the real loop pipe model. After RS model was constructed, using sensitivity-based optimizer performed optimization for the loop pipe. And the moving least square method (MLSM) was applied to reduce the approximation error.

  • PDF

Optimization of the Shape of Loop-pipe in a Reciprocating Compressor Using Genetic Algorithm (유전자 알고리듬을 이용한 왕복동식 압축기 루프 파이프 형상의 최적화)

  • Lee, Yun-Gon;Jung, Byung-Kyoo;Jeong, Weui-Bong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.4
    • /
    • pp.398-405
    • /
    • 2016
  • A shape of loop-pipe in a compressor affects the vibration of compressor. In this paper, optimal design of shape of loop-pipe to decrease the stress was carried out. Body and shell were assumed to be rigid, while loop-pipe is considered to be flexible. The finite element model was derived and programmed. Genetic algorithm was used for optimization. Locations of 18 point in loop-pipe were considered as shape variables, while the shapes of loop-pipe were interpolated as polynomials or ellipses. Maximum stress of loop-pipe was used as a fitness function for optimization. The spatial constraints and acceleration response of shell were also considered in optimization. The maximum stress and acceleration could be reduced by 79 % and 49 % respectively.

Design of Closed Loop Pipe Cooling System (냉각수 순환 형태의 파이프 쿨링 공법의 설계)

  • 박찬규;왕인수;구자중
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2001.11a
    • /
    • pp.52-57
    • /
    • 2001
  • In order to control hydration heat in mass concrete, pipe cooling method has been widely used. The pipe cooling method leads to the decrease of curing period by lagging materials as well as the decrease of temperature difference between center and surface of mass concrete member, There are two methods in the pipe cooling system, which are open loop system and closed loop system. However open loop pipe cooling system cannot be applied to the mass concrete structures when cooling water supply is difficult. To control hydration heat of high strength mass foundation in the central area of city, closed loop pipe cooling system was developed to solve the cooling water supply. This paper reports the performance results of hydration heat control with closed loop pipe cooling system.

  • PDF

Flow Visualization of Bubble Jet Loop Heat Pipe (Bubble Jet Loop Heat Pipe의 유동 가시화)

  • Lee, Hyun-Jik;Kong, Sang-Woon;Ha, Soo-Jung;Hwang, Jong-Ho;Jang, Jeong-Wan;Son, Kil-Jae;Kim, Jong-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.279-283
    • /
    • 2009
  • Bubble jet loop heat pipe is what heat pipe operate in the horizontality. It is consist of one heating part creating bubble and one rounded U tube type radiator. This study shows whether the heat pipe operates well in the horizontality or not, and what optimized refrigerant charging rate is in the tube. But flow visualization of bubble jet heat pipe was not known. The purpose of this study is to visualize bubble jet loop heat pipe. The experiment was performed by changes of charging rate. Working fluid was R-141b. And heater of 220 V & 100 W was used. we take a photograph of flow visualization of bubble jet loop heat pipe in slow motion.

  • PDF

Hydartion Heat Control with Closed Loop Pipe Cooling System (냉각수 순환 형태의 파이프 쿨링 공법을 이용한 매스콘크리트 수화열 제어)

  • 박찬규;손상현;이승훈;장기욱;정재홍;김명식
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.403-408
    • /
    • 2001
  • In order to control hydration heat in mass concrete, pipe cooling method has been widely used. However, open pipe cooling system cannot be applied to the mass concrete structures when cooling water supply is difficult. To control hydration heat of high strength mass foundation, closed loop pipe cooling system was developed to solve the cooling water supply. This paper reports the performance result of hydration heat control with closed loop pipe cooling system.

  • PDF

Analysis of thermal stress and heat transfer due to circulating fluid in ground heat exchanger (지중 열교환기의 순환수에 의한 열응력 및 열전달 거동 분석)

  • Gil, Hu-Jeong;Lee, Kang-Ja;Lee, Chul-Ho;Choi, Hang-Seok;Choi, Hyo-Bum
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.385-395
    • /
    • 2009
  • In this study, a series of numerical analysis has been accomplished on the thermal performance and sectional efficiency of a closed-loop vertical ground heat exchanger (U-loop) in a geothermal heat pump system (GHP) considering the circulating fluid, pipe, grout and soil formation. A finite element analysis program, ABAQUS, was employed to evaluate the temperature distribution on the cross section of the U-loop system involving HDPE pipe/grout/formation and to compare sectional efficiency between the conventional U-loop and a new latticed HDPE pipe system. Especially, the latticed pipe is equipped with a thermal insulation zone in order to reduce thermal interference between the inflow pipe and the outflow pipe. Also, a thermal stress analysis was performed with the aid of ABAQUS. 3-D finite volume analysis program, FLUENT, was adapted to analyze a coupled system between fluid circulation in the pipe and heat transfer and simulate an operating process of the closed-loop vertical ground heat exchanger. In this analysis, the effect of the thermal properties of grout, rate of circulation pump, distance between the inflow pipe and the outflow pipe, and the effectiveness of the latticed HDPE pipe system are taken into account.

  • PDF

Development of Loop Heat Pipe Using Bubble Jet (Bubble Jet을 이용한 Loop Heat Pipe의 개발)

  • Kong, Sang-Woon;Ha, Soo-Jung;Jang, Jeong-Wan;Hwang, Jong-Ho;Son, Kil-Jae;Lee, Hyun-Jik;Kim, Jong-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1503-1506
    • /
    • 2009
  • Bubble jet loop heat pipe is a newly devised variation of heat pipe in which heat is effectively transported by the latent heat of evaporation and condensation as well as the heat capacity of circulating working fluid. The circulatory and oscillating motion of the working fluid becomes possible by the motion of bubble jet which is generated at a narrow circular gap. These bubbles are condensed at the condensing section. Bubble jet loop heat pipe makes it possible to carry heat long distances upward and horizontal directions. Because Its structure is a very simple and a low cost, it is available for the floor heating, vinyl house heating, the defrosting of heat pump system and home refrigerator.

  • PDF

Development of High Performance Bubble Jet Loop Heat Pipe for Hot Water Floor Heating System (온수 가열 바닥 난방 시스템용 고성능 버블젯 루프 히트파이프 개발)

  • Kim, Jong-Soo;Kwon, Yong-Ha;Kim, Jeong-Woong
    • Journal of Power System Engineering
    • /
    • v.18 no.4
    • /
    • pp.23-28
    • /
    • 2014
  • In order to increase the performance of conventional hot water floor heating system, the bubble jet loop heat pipe for the system was developed. This experiment was conducted under next conditions : Working fluid was R-134a, charging ratio was 50%. A temperature of hot water, room temperature and flow rate were $60^{\circ}C$, $15^{\circ}C$ and 0.5~1.5 kg/min, respectively. The experimental results, show that bubble jet loop heat pipe had a high effective thermal conductivity of $4714kW/m^{\circ}C$ and a sufficient heat flux of $73W/m^2$ to heat the floor to $35^{\circ}C$ in case of the 1.5 kg/min of flow rate. So the bubble jet loop heat pipe has a possibility for appling of the floor heating system. Additionally, the visualization of bubble jet loop heat pipe was performed to understand the operating principle. Bubbles made by the narrow gap between inner tube and outer tube of evaporating part generate pulsation at liquid surface of working fluid. The pulsation had slug flow and wavy flow. So working fluid circulates in the bubble jet loop heat pipe as two phase flow pattern. And large amount of heat is transferred by the latent heat from evaporating part to condensing part.

Numerical Evaluation of Heat Transfer un Ground Heat Exchanger Considering Flow through U-loop (파이프 순환수의 수치해석 모사를 통한 수직 밀폐형 지중열교환기 단면의 열전달 효율 평가)

  • Gil, Hu-Jeong;Lee, Chul-Ho;Lee, Kang-Ja;Choi, Hang-Seok
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.583-587
    • /
    • 2009
  • This paper presents a series of numerical simulations on the thermal performance and sectional efficiency of a closed-loop vertical ground heat exchanger (U-loop) equipped in a geothermal heat pump system (GHP). A 3-D finite volume analysis (Fluent) was used to simulate the operating process of the closed-loop vertical ground heat exchanger by considering the effect of the thickness of HDPE pipe and grout thermal properties, distance between the inflow and outflow pipes, and the effectiveness of the latticed HDPE pipe system. It was observed that the thermal interference between the two strands of U-loop is of importance in determining the efficiency of the ground heat exchanger, and thus it is highly recommendable to modify the cross section configuration of the conventional U-loop system by including a thermally insulating latice between the two strands.

  • PDF

Heat Transfer Characteristics of Loop Type Capillary Heat Pipe using R141b as a Working Fluid (R141b를 이용한 루프 세관형 히트파이프의 열전달특성)

  • Kim, Hoon;Ha, Sung-Man;Kim, Tag-Yong;Jeon, Kyung-Whan;Choi, Jae-Hyuck;Yoon, Seok-Hun
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.256-257
    • /
    • 2005
  • This paper has been carried out to investigate heat transfer characteristics of loop type capillary heat pipe using R141b as a working fluid. In an experiment heat load are changed from 50W to 250W and the temperature of cooling water is fixed to 20$^{circ}C$ . The heat pipe is composed of 10 turns and outer diameter of heat pipe is 3.2mm. The results show that heat transport rate of this type heat pipe using R141b as a working fluid is good.

  • PDF