• Title/Summary/Keyword: Loop Probe

Search Result 60, Processing Time 0.028 seconds

Study on the Microwave Dielectric properties in the Dielectric Rod Resonator Method (유전체 원주공진기법에 의한 고주파 유전특성 측정에 관한 연구)

  • Kim, Kyung-Yong;Kim, Wang-Sup;Choi, Hwan
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.3
    • /
    • pp.471-481
    • /
    • 1995
  • Measurement factors for the dielectric properties of low dielectric loss materials (tan${\dalta}{\le}10^{-4}$) were investigated using the dielectric rod resonator method. It was shown that the relative conductivity (${\sigma}_{r}$) should be controlled within a 5% to obtain the standard deviations of less than 0.07 for permittivity .epsilon.r and 0.06${\times}10^{-4}$ for tan.delta.respectively. Surface resistivity (R$_s$) could be reduced when the surface roughness of parallelled conducting plate was less than 0.07 .mu.m. Measurement error for the permittivity was $\pm$0.02% independent of probe loop size, whereas the error in Q value was reduced with the decrease in probe loop size and also with the increase in the absolute values of Q. Reliable Q values were determined with the probe loop size of less than 4mm. The accurate for the distance between the measuring probe loop and the sample could be obtained when the insertion loss of resonant frequency ranged -15dB - -30dB.

  • PDF

A development of accuracy diagnostic system 2-dimensional circular interpolation of machining centers (Machining Center의 2차원 원호보간정밀도 진단 System의 개발)

  • Kim, Jeong-Soon;Namgung, Suk;Tsutusmi, Masacmi
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.10 no.2
    • /
    • pp.54-65
    • /
    • 1993
  • The paper describes and alternative method based on a new idea to measure the circular movement of machining centers. ISO has employed three testing methods for the acceptance tests of machine tools; the first is a rotating one-dimensional probe method, the second is a two-dimensional probe and a master circular ring, and the third is a kinematic ball bar. The last two methods were proposed and introduced by W. Knapp and J. B. Bryan, respectively. The newly developed method is superior to above two methods; the rotating angle can be detected and the rotating radius is variable. Circular movement errors of machining centers were investigated by the analysis of data measured by R- .THETA. method. Followint observations are obtained 1) The errors which depend on positions, i.e., periodical errors by the pitch of ball screws, errors by compensation of backlash and errors by perpendicularity of X and Y-axis, were analyzed. 2) The errors which depend on NC control system, i.e., errors by the unbalance of position-loop-gaians, errors by velocity-loop-gains and errors by feed speeds, were quantiatively analyzed. 3) The method of extracting error information, which uses moving technique of averaging angle and fourier's analysis data mesured by the R- .THETA. method, was proposed.

  • PDF

The simulator loop probe style magnetic stimulation design for a nervous system treatment (신경계 치료를 위한 루프 프로브형 자기자극기의 시뮬레이터)

  • Kim, Whi Young
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.5 no.3
    • /
    • pp.29-37
    • /
    • 2009
  • It is as result that study to apply mini magnet nerve curer in peripheral nervous system disease treatment. Simulator and embodied action power and Control Unit in cylinder form of magnet roof object firstly. Yielded service area about special quality of probe of loop object cylinder style and treatment area dimension and distance of treatment pulse secondly. Embody pulse forming course energy value by Probe's form by third, could embody treatment pulse by disease. Specially, through a special quality experiment, saved Damping pulse form and treatment digital forming etc. variously. Lately, embodied this to aid a little in disease treatment that follow that there is no invasion that there is no stimulation by medicine development. Neuralgia, muscular disease and Altzheimer, with stroke etc. is becoming the matter of concern and interest which disease of adult etc. it is same is important. And the melancholia in compliance with the modern direction of a ceremony which is complicated and garrulous, trillion it will cry and symptoms, it is a tendency where the emotional obstacle etc. nervous psychiatric disorder patient is increasing at class speed. But currently the applicator it will be able to treat like this disease almost it is a condition which is wholly lacking. Consequently like this disease it used magnetic stimulation and it diagnosed and the equipment it will be able to treat plan and it embodied.

Measurement Error Modeling for On-Machine Measurement of Sculptured Surfaces

  • Cho, Myeong-Woo;Lee, Se-Hee;Seo, Tae-Il
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.2 no.2
    • /
    • pp.73-80
    • /
    • 2001
  • The objective of this research is to develop a measurement error model for sculptured surface in On-Machine Measurement(OMM) process based on a closed-loop configuration. The geometric error model of each axis of a vertical CNC machining center is derived using a 4$\times$4 homogeneous transformation matrix. The ideal locations of a touch-type probe for the sculptured surface measurement are calculated from the parametric surface representation and X-, Y- directional geometric errors of the machine. Also the actual coordinates of the probe are calculated by considering the pre-travel variation of a probe and Z-directional geometric errors. Then, the step-by-sep measurement error analysis method is suggested based on a closed-loop configuration of the machining center including workpiece and probe errors. The simulation study shows the simplicity and effectiveness of the proposed error modeling strategy.

  • PDF

On-Machine Measurement of Sculptured Surfaces Based on CAD/CAM/CAI Integration : I. Measurement Error Modeling (CAD/CAM/CAI 통합에 기초한 자유곡면의 On-Machine Measurement : I. 측정오차 모델링)

  • Cho, Myeong-Woo;Lee, Se-Hee;Seo, Tae-Il
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.10
    • /
    • pp.172-181
    • /
    • 1999
  • The objective of this research is to develop a measurement error model for sculptured surfaces in On-Machine Measurement (OMM) process based on a closed-loop configuration. The geometric error model of each axis of a vertical CNC Machining center is derived using a 4${\times}$4 homogeneous transformation matrix. The ideal locations of a touch-type probe for the scupltured surface measurement are calculated from the parametric surface representation and X-, Y- directional geometric errors of the machine. Also, the actual coordinates of the probe are calculated by considering the pre-travel variation of a probe and Z-directional geometric errors. Then, the step-by-step measurement error analysis method is suggested based on a closed-loop configuration of the machining center including workpiece and probe errors. The simulation study shows the simplicity and effectiveness of the proposed error modeling strategy.

  • PDF

Loop Probe Design and Measurement of Electromagnetic Wave Signal for Contactless Cryptographic Analysis (비접촉 암호 분석용 루프 프로브 설계 및 전자파 신호 측정)

  • Choi, Jong-Kyun;Kim, Che-Young;Park, Jea-Hoon;Moon, Snag-Jae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.10
    • /
    • pp.1117-1125
    • /
    • 2007
  • In this paper, a study has been performed on the design of small loop probe and analysis of induced electromagnetic wave signal from a smartcard for contactless cryptographic analysis. Probes for cryptographic analysis are different from conventional EM probes, because the purpose of proposed probe is to obtain the information for secret key analysis of cryptographic system. The waveform of induced voltage on probe must be very close to radiated waveform from IC chip on smartcard because electromagnetic attack makes an attempt to analyze the radiated waveform from smartcard. In order to obtain secret key information, we need to study about cryptographic analysis using electromagnetic waves, an approximate model of source, characteristic of probe for cryptographic analysis, measurement of electromagnetic waves and calibration of probes. We measured power consumption signal on a smartcard chip and electromagnetic wave signal using proposed probe and compared with two signals of EMA point of view. We verified experimently the suitability of the proposed small loop probe for contactless cryptographic analysis by applying ARIA algorithm.

Development of Pocket Insertion style Magnetic Curer that Apply $2^{loop}\;3^{pulsed}$ Variable Magnetic type Probe for Urinary Treatment

  • Kim, Whi-Young
    • Journal of information and communication convergence engineering
    • /
    • v.6 no.1
    • /
    • pp.73-79
    • /
    • 2008
  • Result that study magnet nerve curer for treatment induced current generation and current of ion for development in main point incontinence, prostate, sphincter, nervous system, rigidity, headache, retrogression arthritis, ligament damage, Rheumatism arthritis, peripheral nerve etc., can classify by 4. Embodied do first, full bridge magnet occurrence chapter, and communication with PC is available, confirmed various action loops an experiment. Could confirm correct treatment probe second, woman and man disease person. Third, derived so that healing may be possible naturally by addition of apron form according to disease. Because composition of finally, treatment probe composes by act of negative plate form, manufacture is easy and cooling designed for easy direction. More superior result of cooling appeared than existing in incidental and ingredients, cooling efficiency, composition, complexity, convenience etc. that expense and composition manufacture very straightforwardly and experimental by 2 - Tank ways.

Mini loop coil magnetic curer for peripheral nervous system treatment (말초신경계 치료를 위한 미니 Loop - 코일 삽입형 자기치료기)

  • Kim, Whi-Young
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.49-51
    • /
    • 2007
  • It is as result that study to apply mini magnet nerve curer in peripheral nervous system disease treatment. Design and embodied action power and Control Unit in cylinder form of magnet roof object firstly. Yielded service area about special quality of probe of roof object cylinder style and treatment area dimension and distance of treatment pulse secondly. Embody pulse forming course energy value by Probe's form by third, could embody treatment pulse by disease. Specially, through a special quality experiment, saved Damping pulse torn and treatment pulse form etc. variously. Lately, embodied this to aid a little in disease treatment that follow that there is no invasion that there is no stimulation by medicine development. Go amplitude treatment pulse (traditional magneto-therapy of greatly great that strong) does curative effect greatest at short time and becomes thought that demand is magnified greatly at the future in this research.

  • PDF

Effect of RFLP Marker of the Mitochondrial DNA D-Loop Region on Milk Production in Korean Cattle (한우 Mitochondrial DNA D-Loop 영역의 RFLP Marker가 산유량에 미치는 영향)

  • Chung Eui-Ryong;Chung Ku-Young
    • Food Science of Animal Resources
    • /
    • v.25 no.2
    • /
    • pp.218-225
    • /
    • 2005
  • This study was performed to determine sequence variation and RFLP of the mt DNA D-loop region using Southern blot hybridization analysis and to develop mt DNA marker affecting milk production traits in Hanwoo cows. The PCR was used to amplify an 1142 bp fragment within the D-loop region of mt DNA using specific primers. Mt DNA were digested with seven restriction enzymes and hybridized using DIG-labeled D-loop probe. The mt DNA RFLP polymorphisms were observed in the four enzymes, BamHI, RsaI, XbaI and HpaII. Nucleotide substitutions were detected at positions 441 (G/C), 469 (T/C), 503 (C/T), 569 (G/A), 614 (C/A) and 644 (C/T) of the mt DNA D-loop region between two selected lines. Significant relationship between the XbaI RFLP type and breeding value was found(p<0.05). Cows with A type had higher estimated breeding values than those with B type (P<0.05) between high and low milk production lines. Therefore, the RFLP marker of mt DNA could be used as a selection assisted tool for individuals with high milk producing ability in Hanwoo.

Target Recognition Triggered Split DNAzyme based Colorimetric Assay for Direct and Sensitive Methicillin-Resistance Analysis of Staphylococcus aureus

  • Jin Xu;Dandan Jin;Zhengwei Wang
    • Journal of Microbiology and Biotechnology
    • /
    • v.34 no.6
    • /
    • pp.1322-1327
    • /
    • 2024
  • The accurate and rapid detection of methicillin-resistant Staphylococcus aureus (MRSA) holds significant clinical importance. This work presents a new method for detecting methicillin-resistant Staphylococcus aureus (S. aureus) in clinical samples. The method uses an aptamer-based colorimetric assay that combines a recognizing probe to identify the target and split DNAzyme to amplify the signal, resulting in a highly sensitive and direct analysis of methicillin-resistance. The identification of the PBP2a protein on the membrane of S. aureus in clinical samples leads to the allosterism of the recognizing probe, and thus provides a template for the proximity ligation of split DNAzyme. The proximity ligation of split DNAzyme forms an intact DNAzyme to identify the loop section in the L probe and generates a nicking site to release the loop sequence ("3" and "4" fragments). The "3" and "4" fragments forms an intact sequence to induce the catalytic hairpin assembly, exposing the G-rich section. The released the G-rich sequence of LR probe induces the formation of G-quadruplex-hemin DNAzyme as a colorimetric signal readout. The absorption intensity demonstrated a strong linear association with the logarithm of the S. aureus concentration across a wide range of 5 orders of magnitude dynamic range under the optimized experimental parameters. The limit of detection was calculated to be 23 CFU/ml and the method showed high selectivity for MRSA.