• 제목/요약/키워드: Longitudinal Steel

검색결과 713건 처리시간 0.023초

강섬유 철근콘크리트의 균열특성 (Crack Behavior of Steel Fiber Reinforced Concrete)

  • 강보순;황성춘;심형섭
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 추계학술대회 논문집
    • /
    • pp.336-343
    • /
    • 2000
  • Crack behavior of steel fiber concrete(SFC) and reinforced steel fiber concrete(RSFC) specimens has been experimentally and analytical investigated. Clack behavior of RSFC beams influenced by longitudinal reinforcement ratio, volume and type of steel fiber, strenth of concrete. It can be observed from experimental result that addition of steel fiber to concrete specimen reduce crack width and increases stiffness, and thus enhances the behavior in serviceability limit states also high cyclic loading

  • PDF

유한대판법을 사용한 강상판 교량의 해석 (Analysis of the Steel Deck Bridges using the Finite Strip Method)

  • 최창근;홍현석
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1998년도 봄 학술발표회 논문집
    • /
    • pp.77-84
    • /
    • 1998
  • The finite strip method is presented for the analysis of steel deck bridges. Like the Pelikan-Esslinger design method for the steel deck bridges, steel deck is treated as an equivalent orthotropic plate. In the presented method, the deck is discretised by finite strips in the longitudinal direction and the effect of main girder or floor beam deflection can also be accounted for. In this method, the terms of harmonic series at elastically support such as transverse floor or diaphragm in steel deck become coupled. Solutions of this method are compared with other available analytical and numerical solution, and good agreement is observed.

  • PDF

Short- and long-term analyses of composite beams with partial interaction stiffened by a longitudinal plate

  • Ranzi, Gianluca
    • Steel and Composite Structures
    • /
    • 제6권3호
    • /
    • pp.237-255
    • /
    • 2006
  • This paper presents a novel analytical formulation for the analysis of composite beams with partial shear interaction stiffened by a bolted longitudinal plate accounting for time effects, such as creep and shrinkage. The model is derived by means of the principle of virtual work using a displacement-based formulation. The particularity of this approach is that the partial interaction behaviour is assumed to exist between the top slab and the joist as well as between the joist and the bolted longitudinal stiffening plate, therefore leading to a three-layered structural representation. For this purpose, a novel finite element is derived and presented. Its accuracy is validated based on short-and long-term analyses for the particular cases of full shear interaction and partial shear interaction of two layers for which solutions in closed form are available in the literature. A parametric study is carried out considering different stiffening arrangements to investigate the influence on the short-and long-term behaviour of the composite beam of the shear connection stiffness between the concrete slab and the steel joist, the stiffness of the plate-to-beam connection, the properties of the longitudinal plate and the concrete properties. The values of the deflection obtained from the finite element simulations are compared against those calculated using the effective flexural rigidity in accordance with EC5 guidelines for the behaviour of elastic multi-layered beams with flexible connection and it is shown how the latter well predicts the structural response. The proposed numerical examples highlight the ease of use of the proposed approach in determining the effectiveness of different retrofitting solutions at service conditions.

고강도 콘크리트 기둥의 2계 거동에 관한 실험적 연구 (Experiments on Second -Order Behavior of High Strength Concrete Columns)

  • 김진근;양주경
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1992년도 가을 학술발표회 논문집
    • /
    • pp.167-172
    • /
    • 1992
  • To analyze the effects compressive strength of concrete and longitudinal steel ratio on second-order moment of columns, 30tied rein reinforced concrete columns with hinged ends were tested. The 80mm square cross section was used and the amount of eccentricity was 24mm. The compressive strengths of column specimens with slenderness ratios of 10, 60, and 100were 250, 648 and 880kg/$\textrm{cm}^2$, and the longitudinal steel ratios were 1.98%(4-D6) and 3.95%(8-D6). The ratio of ultimate load capacity to that of short column with the same eccentricity (Pu/Pn) was much decreased at high slenderness ratio with increasing the compressive strength of concrete. And the lateral displacement of slender column at the ultimate load was decreased as the strength was increased. These are due to that at high slenderness ratio the load capacity and behavior of column are affected by flexural rigidity. And, it was also found that with increasing steel ratio, the value of Pu/Pn and the lateral displacement at the ultimate load were larger for the same slenderness ratio.

  • PDF

편심을 받는 고강도콘크리트 장주의 2차모멘트에 관한 실험적 연구 (Experimental Study on Secondary Moment of High-Strength RC Slender Columns under Eccentric Loads)

  • 박동규;배성용;이재훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 가을 학술발표논문집(II)
    • /
    • pp.571-576
    • /
    • 1998
  • This paper is a part of a research plan aimed at the verification of basic design rules of high-strength concrete columns. A total of 19 slender column specimens were tested to measure secondary moment and stiffness of eccentrically loaded reinforced concrete tied columns. Main variables included in this test program were concrete compressive strength, steel amount, eccentricity, and slenderness ratio. The concrete compressive strength varied from 356kg/$\textrm{cm}^2$ to 951kg/$\textrm{cm}^2$, the longitudinal steel ratios were between 1.13% and 5.51%, and slenderness ratios were 40 and 61. Calculated moment magnification factors and column stiffness based on design codes are higher than the test results for high axial load under small eccentricity, for higher slenderness ratio, for lower longitudinal steel ratio, and for high-strength concrete. The moment magnification method of the current design codes may provide a very conservative design for high-strength concrete slender column.

  • PDF

R/C 연속보의 아치작용에 대한 연구 (Arch Action in Continuous Reinforced Concrete Beams)

  • 김준성;김대중;김우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회논문집(I)
    • /
    • pp.629-634
    • /
    • 2000
  • In this study, 9 reinforced concrete(RC) continuous beams were tested to investigate the arch action. By measuring longitudinal steel strains during the whole loading stages up to failure, the development of arch action is evaluated. Variables included are span length, longitudinal steel ratio and the presence of stirrups. As a result, it was known that measured steel tension in the span is substantially higher than the conventionally calculated values, and it was appeared that near the middle of the shear span the measured values exceeded the calculated values by factors of up to 1.4 or more.

  • PDF

보강띠철근의 상세에 따른 중공 사각형 교각 압축부의 파괴 거동 (Behavior of Rectangular Hollow Bridge Compression Section by Detail of Cross-tie)

  • 이재훈;김호영;곽임종
    • 한국지진공학회논문집
    • /
    • 제21권1호
    • /
    • pp.21-29
    • /
    • 2017
  • Purpose of this study is to investigate structural behavior of the rectangular hollow column with various transverse reinforcement details. Experimental variables are diameter, arrangement details and lateral spacing of cross tie. A total of 66 column specimens have been prepared and tested under axial compressive load. Test results showed that behaviors of column specimens were different depending on the cross tie details. Specimens with cross tie wrapping longitudinal steel and transverse steel have greater strength and ductility than specimens with cross tie wrapping the longitudinal steel.

Basis for the design of lateral reinforcement for high-strength concrete columns

  • Mendis, P.A.;Kovacic, D.;Setunge, S.
    • Structural Engineering and Mechanics
    • /
    • 제9권6호
    • /
    • pp.589-600
    • /
    • 2000
  • This paper attempts to provide a theoretical basis for the design of high-strength concrete columns in terms of the spacing of lateral reinforcement. In order to achieve this, important concepts had to be addressed such as the choice of a measure of ductile behaviour and a realistic high-strength concrete stress-strain model, as well as limiting factors such as longitudinal steel buckling and lateral steel fracture. A design method incorporating above factors are suggested in the paper. It is shown that both buckling of longitudinal steel and hoop fracture will not demand a reduction in spacing of lateral ties with increase in compressive strength of concrete.

FRP Rods로 보강한 콘크리트 보의 전단 내하력의 평가 (Estimation of Shear Carrying Capacity on Concrete Beams, Reinforced with FRP Rods)

  • 최익창;연준희;고재용
    • 한국해양공학회지
    • /
    • 제18권1호
    • /
    • pp.63-68
    • /
    • 2004
  • The purpose of this study is to estimate the contribution of concrete and shear reinforcement, in shear carrying capacity, on concrete beams, reinforced with steel and/or FRP rods. The experimental tests for 12 concrete beams, reinforced with steel and/or FRP rods, are carried out. Experimental parameters includes the mechanical properties of reinforcements in shear and bending, and the ratio of shear reinforcement. This study compares the experimental results of shear carrying capacity in concrete beams, reinforced with steel and/or FRP rods, with the proposed equations. According to the experimental results, the effect of the concrete in concrete beams reinforced with FRP rods is decreased with decreasing Young's modulus of longitudinal tensile reinforcement. This results from the large deflection of concrete beams reinforced with decreasing Young's modulus of longitudinal tensile reinforcement. Also, the contribution of shear reinforcement is smaller than the calculated value, using the truss analogy. This results from the fact that the stress redistribution is not exhibited after the break of shear reinforcement.

Attenuation of Fundamental Longitudinal Cylindrical Guided Wave Propagating in Liquid-Filled Steel Pipes

  • NA WON-BAE;RYU YEON-SUN;KIM JEONG-TAE
    • 한국해양공학회지
    • /
    • 제19권5호
    • /
    • pp.26-33
    • /
    • 2005
  • Attenuation of fundamental longitudinal guided wave propagating liquid-filled steel pipes is numerically investigated. Several liquids such as water, diesel oil, castor oil etc. are considered for the filing materials in the pipes. Sink is considered for numerical models for abandoning standing wave modes; hence the attenuation dispersion curves become much simpler. Those attenuation calculations can be utilized for guided-wave-based nondestructive testing of pipelines when one inspects pipelines, using monitoring sensors, which are installed outside pipes.