• 제목/요약/키워드: Long-range Correlation

검색결과 211건 처리시간 0.036초

병원 간호사의 업무환경, 감정노동이 이직의도에 미치는 영향 (The Effects of Work Environment, Emotional Labor on Turnover Intention by Hospital Nurses)

  • 남문희
    • 한국임상보건과학회지
    • /
    • 제3권1호
    • /
    • pp.256-267
    • /
    • 2015
  • Purpose. The objective of this study was to investigate factors influencing turnover intention index of work environment, emotional labor by hospital nurses Methods. A survey was conducted with 290 nurses who were working hospital. Data were analyzed using descriptive statistics, t-test, ANOVA, Pearson correlation coefficients and multiple regression with SPSS window 18.0 program. Result. Findings revealed that; 1) The mean scores were 2.81 [range : 1-5] for work environment, 3.24 [range : 1-5] for emotional labor, 3.43 [range : 1-5] for turnover intention. 2) Pearson's correlation revealed work environment was negatively correlated with turnover intention but emotional labor positively correlated with the turnover intention. 3) Hrarchical multiple regression analysis showed work environment, ages, assign ward, period in current hospital, emotional labor significantly influenced turnover intention in hospital nurses. Conclusion. These findings can be utilized to development of strategies to improving the work environment, managing the emotional labor for decreasing turnover intention of hospital nurses so that can be long time.

Simulations of Two-Dimensional Electronic Correlation Spectra

  • 김학진;전성준
    • Bulletin of the Korean Chemical Society
    • /
    • 제22권8호
    • /
    • pp.807-815
    • /
    • 2001
  • Two-dimensional (2D) correlation method, which generates the synchronous and the asynchronous 2D spectrum by complex cross correlation of the Fourier transformed spectra, is an analysis method for the changes of the sample spectrum induced by vari ous perturbations. In the present work, the 2D electronic correlation spectra have been simulated for the cases where the sample spectrum composed of two gaussian bands changes linearly. When only the band amplitudes of the sample spectrum change, the synchronous spectrum shows strong peaks at the band centers of the sample spectrum, but the asynchronous spectrum does not make peaks. When the sample spectrum shifts without changing intensity and width, the synchronous spectrum shows peaks around the initial and final positions of the band maximum and the asynchronous spectrum shows long peaks spanning the shifting range. The band width change produces the complex 2D correlation spectra. When the sample spectrum shifts with band broadening, the width change by 50% of full width at half maximum (FWHM) does not give so large an effect on the correlation spectrum as the spectral shift by one half of FWHM of the sample spectrum.

A Statistic Correlation Analysis Algorithm Between Land Surface Temperature and Vegetation Index

  • Kim, Hyung-Moo;Kim, Beob-Kyun;You, Kang-Soo
    • Journal of Information Processing Systems
    • /
    • 제1권1호
    • /
    • pp.102-106
    • /
    • 2005
  • As long as the effective contributions of satellite images in the continuous monitoring of the wide area and long range of time period, Landsat TM and Landsat ETM+ satellite images are surveyed. After quantization and classification of the deviations between TM and ETM+ images based on approved thresholds such as gains and biases or offsets, a correlation analysis method for the compared calibration is suggested in this paper. Four time points of raster data for 15 years of the highest group of land surface temperature and the lowest group of vegetation of the Kunsan city Chollabuk_do Korea located beneath the Yellow sea coast, are observed and analyzed their correlations for the change detection of urban land cover. This experiment based on proposed algorithm detected strong and proportional correlation relationship between the highest group of land surface temperature and the lowest group of vegetation index which exceeded R=(+)0.9478, so the proposed Correlation Analysis Model between the highest group of land surface temperature and the lowest group of vegetation index will be able to give proof an effective suitability to the land cover change detection and monitoring.

MCP방법을 이용한 장기간 풍속 및 풍력에너지 변동 특성 분석 (Variability Characteristics Analysis of the Long-term Wind and Wind Energy Using the MCP Method)

  • 현승건;장문석;고석환
    • 한국태양에너지학회 논문집
    • /
    • 제33권5호
    • /
    • pp.1-8
    • /
    • 2013
  • Wind resource data of short-term period has to be corrected a long-term period by using MCP method that Is a statistical method to predict the long-term wind resource at target site data with a reference site data. Because the field measurement for wind assessment is limited to a short period by various constraints. In this study, 2 different MCP methods such as Linear regression and Matrix method were chosen to compare the predictive accuracy between the methods. Finally long-term wind speed, wind power density and capacity factor at the target site for 20 years were estimated for the variability of wind and wind energy. As a result, for 20 years annual average wind speed, Yellow sea off shore wind farm was estimated to have 4.29% for coefficient of variation, CV, and -9.57%~9.53% for range of variation, RV. It was predicted that the annual wind speed at Yellow sea offshore wind farm varied within ${\pm}10%$.

동북아 장거리 수송 과정에서 적운 모수화 및 미세물리과정이 오존 모사농도에 미치는 영향 연구 (A Study on the Effect of Cumulus Parameterization and Microphysics on Ozone Simulations during Long-range Transport Process over Northeast Asia)

  • 강정언;김철희
    • 한국대기환경학회지
    • /
    • 제29권2호
    • /
    • pp.135-151
    • /
    • 2013
  • This study has been carried out to analyze the sensitivity of ozone concentrations by employing different options of cumulus parameterization schemes (CPSs) and microphysics schemes in MM5 models. These sensitivity tests were applied to long-range transport case of higher ozone over Northeast Asia. Employed CPS schemes are Betts-Miller (BM), Grell (GR), Kain-Fritsch2 (KF2), Anthes-Kuo (AK), None scheme (grid scale physics only), and four microphysics used here are Simple ice, Reisner1, Reisner2, Schultz scheme in MM5. We chose two cases of high ozone long range transport case by employing both concentrations ozone level and backward trajectory model. The results showed that modeled ozone concentrations indicated about 10% differences among CPSs. Of the all options, GR and KF2 (for CPS), and Rersiner-1 and Resiner-2 (for microphysics) showed relatively good and stable variations against ensemble mean values. For both CPS and microphysics schemes, the difference of precipitation arising from different parameterization schemes was significant by itself, but the resultant ozone variations showed only marginal. But the cloud fraction differences arising from different parameterization schemes showed better correlation with ozone variations than precipitation differences, indicating that the photochemical ozone generation variations is more dominant by cloud fraction than wet removal process for high and long-ranged transported ozone cases over Northeast Asia.

Development of Water Supply System under Uncertainty

  • Chung, Gun-Hui;Kim, Tae-Woong;Kim, Joong-Hoon
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2009년도 학술발표회 초록집
    • /
    • pp.2179-2183
    • /
    • 2009
  • As urbanization is progressed, the network for distributing water in a basin become complex due to the spatial expansion and parameter uncertainties of water supply systems. When a long range water supply plan is determined, the total construction and operation cost has to be evaluated with the system components and parameter uncertainties as many as possible. In this paper, the robust optimization approach of Bertsimas and Sim is applied in a hypothetical system to find a solution which remains feasible under the possible parameter uncertainties having the correlation effect between the uncertain coefficients. The system components to supply, treatment, and transport water are included in the developed water supply system and construction and expansion of the system is allowed for a long-range period. In this approach, the tradeoff between system robustness and total cost of the system is evaluated in terms of the degree of conservatism which can be converted to the probability of constraint violation. As a result, the degree of conservatism increases, the total cost is increased due to the installation of large capacity of treatment and transportation systems. The applied robust optimization technique can be used to determine a long-range water supply plan with the consideration of system failure.

  • PDF

ON THE LONG TIME SPECTRAL VARIABILITY OF NGC 5548

  • ISMAILOV, NARIMAN Z.;BASHIROVA, ULVIYYE Z.
    • 천문학논총
    • /
    • 제30권2호
    • /
    • pp.531-533
    • /
    • 2015
  • We have investigated the long term variability of the intensities of the broad-line region emission lines in the UV spectra of Seyfert I galaxy NGC 5548 from 1973-1996. We have obtained the following results: 1) a high level correlation between the intensities of emission lines as well as between intensities of emission lines and continuum fluxes was discovered. With increasing wavelength the correlation in both cases becomes weaker, 2) the relationship between the intensity of emission lines and the flux radiation in the continuum can be expressed by a power law function with coefficients of ${\alpha}{\approx}0.8-1.1$ for different lines. When the difference between the wavelengths of spectral lines and the continuum is increased, the value of the power function decreases, and 3) it was found that the magnitude of the variability of the line intensities are weaker than the range of variability of the continuum fluxes. The magnitude of the variability of the line intensities and the continuum fluxes increase at longer wavelengths.

변동환경 대응을 위한 난방System의 쾌적 알고리즘 개발 (Development of comfort algorism for Indoor temperature chagne in Heating System)

  • 김동규;정용현;금종수
    • 수산해양교육연구
    • /
    • 제18권3호
    • /
    • pp.229-235
    • /
    • 2006
  • This study investigated physiology and psychological response of subjects, when heat pump was operated long time within comfort temperature range. Eight subjects were participated for the experiment. Their age was from 22 to 25 years old. The results of this experiment will propose basic data for improving comfort control algorithm in fluctuating environment by using heat pump. When indoor temperature was controlled by heat pump, the conclusion was as follows. 1) When votes of subjects was considered, the thermal comfort neutrality or lower range helped formation of comfort sensation for subjects. 2) When room temperature was lower, thermal comforts of shoulder, knee and foot with subjects thermal comfort showed high correlation. And when room temperature was higher, thermal comfort of face region with subjects thermal comfort showed high correlation. 3) The necessity of temperature change after 50 minutes from initially operating heat pump demands the additional analysis against the physiological signal.

당화혈색소 측정을 위한 Norudia® HbA1c 키트의 평가 (Evaluation of Norudia® HbA1c Kit for Glycohemoglobin Assay)

  • 홍승복;김은중
    • 대한임상검사과학회지
    • /
    • 제41권1호
    • /
    • pp.37-41
    • /
    • 2009
  • Measurement of hemoglobin A1c is used as an objective indicator of long-term blood glucose control in diabetic patients. We evaluated recently introduced Norudia$^{(R)}$ HbA1c (Daiichi Pure Chemical Co. Ltd, Tokyo, Japan) test reagent using enzyme method for HbA1c assay. Linearity, precision and correlation with VARIANT$^{TM}$ II Turbo HbA1c analyzer (BIO-RAD, Hercules, CA, USA) were evaluated. The reference range was determined from 201 healthy subjects. The Norudia$^{(R)}$ HbA1c test reagent was founded to be linear in a range of 5.6% to 14.0% ($r^2=0.9885$). The within-run and between-day precision were 0.954% and 1.03% for low level (HbA1c 5.24%), 0.67% and 1.28% for high level (HbA1c 9.01%), respectively. Comparison study between Norudia$^{(R)}$ HbA1c test reagent and VARIANT$^{TM}$ II Turbo showed good correlation with a slope of 1.0489. an intercept at -0.9717, and coefficient of correlation was 0.9907. The reference range of HbA1c obtained from this reagent was 4.07-5.50%. The Norudia$^{(R)}$ HbA1c test reagent showed good linearity, precision and correlation with HbA1c analyzer with HPLC method. In addition, the exclusive analyzer is not required for assay and then this kit may be useful for HbA1c assay in clinical laboratory.

  • PDF

Shifting-Level Process에 기반한 영상트래픽 모델 (1부: 모델링과 대기체계 영향 분석) (A Video Traffic Model based on the Shifting-Level Process (Part I : Modeling and the Effects of SRD and LRD on Queueing Behavior))

  • 안희준;강상혁;김재균
    • 한국통신학회논문지
    • /
    • 제24권10B호
    • /
    • pp.1971-1978
    • /
    • 1999
  • 본 논문에서는‘shifting-level (SL) process’을 기초로 한 모델을 사용하여, VBR 부호화된 영상트래픽의 long-range dependence (LRD) 특성이 대기체계에 미치는 영향에 대해서 연구하였다. 연구 내용은 제1부와 제2부로 나누어 전개된다. 제 1부에서는 실제 영상트래픽의 자기상관함수가 exponential과 hyperbolic의 복합함수로 매우 정확히 표현될 수 있음을 보이고, 이러한 조건을 만족하는 SL process with compound correlations(SLCC)를 제안한다. 대표적인 SRD 모델인 DAR(1)모델과의 대기성능 비교를 통하여 hyperbolic한 상관도가 대기체계에 끼치는 영향을 분석한다. 분석결과 영상의 LRD 특성이 대기체계에 끼치는 영향의 중요도는 단순히‘Yes/No’로 답할 수 없으며, 트래픽 부하가 높아지면 그 영향이 강하게 나타나고, 반대로 트래픽 부하가 낮은 경우에는 무시할 수 있을 정도로 약하게 나타남을 알 수 있다. 여기에 사용하는 SL/D/1/K 대기체계의 해석방법을 제2부에서 다루게 된다.

  • PDF