• 제목/요약/키워드: Long cable

검색결과 497건 처리시간 0.032초

Simulation of vibrations of Ting Kau Bridge due to vehicular loading from measurements

  • Au, F.T.K.;Lou, P.;Li, J.;Jiang, R.J.;Zhang, J.;Leung, C.C.Y.;Lee, P.K.K.;Lee, J.H.;Wong, K.Y.;Chan, H.Y.
    • Structural Engineering and Mechanics
    • /
    • 제40권4호
    • /
    • pp.471-488
    • /
    • 2011
  • The Ting Kau Bridge in Hong Kong is a cable-stayed bridge comprising two main spans and two side spans. The bridge deck is supported by three towers, an end pier and an abutment. Each of the three towers consists of a single reinforced concrete mast strengthened by transverse cables and struts. The bridge deck is supported by four inclined planes of cables emanating from anchorages at the tower tops. In view of the heavy traffic on the bridge, and threats from typhoons and earthquakes originated in areas nearby, the dynamic behaviour of long-span cable-supported bridges in the region is always an important consideration in their design. Baseline finite element models of various levels of sophistication have been built not only to match the bridge geometry and cable forces specified on the as-constructed drawings but also to be calibrated using the vibration measurement data captured by the Wind and Structural Health Monitoring System. This paper further describes the analysis of axle loading data, as well as the generation of random axle loads and simulation of vibrations of the bridge using the finite element models. Various factors affecting the vehicular loading on the bridge will also be examined.

Aerodynamic performance evaluation of different cable-stayed bridges with composite decks

  • Zhou, Rui;Ge, Yaojun;Yang, Yongxin;Du, Yanliang;Zhang, Lihai
    • Steel and Composite Structures
    • /
    • 제34권5호
    • /
    • pp.699-713
    • /
    • 2020
  • The aerodynamic performance of long-span cable-stayed bridges is much dependent on its geometrical configuration and countermeasure strategies. In present study, the aerodynamic performance of three composite cable-stayed bridges with different tower configurations and passive aerodynamic countermeasure strategies is systematically investigated by conducting a series of wind tunnel tests in conjunction with theoretical analysis. The structural characteristics of three composite bridges were firstly introduced, and then their stationary aerodynamic performance and wind-vibration performance (i.e., flutter performance, VIV performance and buffeting responses) were analyzed, respectively. The results show that the bridge with three symmetric towers (i.e., Bridge I) has the lowest natural frequencies among the three bridges, while the bridge with two symmetric towers (i.e., Bridge II) has the highest natural frequencies. Furthermore, the Bridge II has better stationary aerodynamic performance compared to two other bridges due to its relatively large drag force and lift moment coefficients, and the improvement in stationary aerodynamic performance resulting from the application of different countermeasures is limited. In contrast, it demonstrates that the application of both downward vertical central stabilizers (UDVCS) and horizontal guide plates (HGP) could potentially significantly improve the flutter and vortex-induced vibration (VIV) performance of the bridge with two asymmetric towers (i.e., Bridge III), while the combination of vertical interquartile stabilizers (VIS) and airflow-depressing boards (ADB) has the capacity of improving the VIV performance of Bridge II.

FRP-콘크리트 합성 바닥판의 사장교 적용 (Application of FRP-Concrete Composite Deck to Cable Stayed Bridge)

  • 조근희;박성용;김성태;김병석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.217-220
    • /
    • 2008
  • FRP-콘크리트 합성 바닥판을 개선하여 사장교에 경제적으로 적용 가능한 바닥판을 개발하고, 이의 설계 및 경제성 등을 제시한다. 기존의 FRP-콘크리트 합성 바닥판은 탄성계수가 낮은 GFRP 패널의 채용으로 인하여 낮은 단면 강성을 갖게 되는데, 이는 바닥판의 처짐 등과 같은 사용성 문제를 야기할 수 있다. 그래서 기존 FRP-콘크리트 합성 바닥판의 양단을 콘크리트로 감싸서 순지간이 줄어드는 효과를 얻을 수 있는 프리캐스트 FRP-콘크리트 바닥판을 고안하였다. 이 바닥판은 기존 바닥판에 비해 바닥판 지간은 늘어나면서 자중은 크게 늘지 않는 장점을 가진다. 이러한 개선된 바닥판에 대해 거더와 합성하는 경우, 거더 위에서 단순지지하는 경우로 나누어 단면 최적화를 수행하였다. 최적화된 바닥판을 중앙지간 540m인 사장교에 적용한 결과, 상부구조 및 케이블 물량의 감소 효과를 얻을 수 있어 경제적으로 적용될 수 있음을 확인하였다.

  • PDF

Ultrasonic guided wave approach incorporating SAFE for detecting wire breakage in bridge cable

  • Zhang, Pengfei;Tang, Zhifeng;Duan, Yuanfeng;Yun, Chung Bang;Lv, Fuzai
    • Smart Structures and Systems
    • /
    • 제22권4호
    • /
    • pp.481-493
    • /
    • 2018
  • Ultrasonic guided waves have attracted increasing attention for non-destructive testing (NDT) and structural health monitoring (SHM) of bridge cables. They offer advantages like single measurement, wide coverage of acoustical field, and long-range propagation capability. To design defect detection systems, it is essential to understand how guided waves propagate in cables and how to select the optimal excitation frequency and mode. However, certain cable characteristics such as multiple wires, anchorage, and polyethylene (PE) sheath increase the complexity in analyzing the guided wave propagation. In this study, guided wave modes for multi-wire bridge cables are identified by using a semi-analytical finite element (SAFE) technique to obtain relevant dispersion curves. Numerical results indicated that the number of guided wave modes increases, the length of the flat region with a low frequency of L(0,1) mode becomes shorter, and the cutoff frequency for high order longitudinal wave modes becomes lower, as the number of steel wires in a cable increases. These findings were used in design of transducers for defect detection and selection of the optimal wave mode and frequency for subsequent experiments. A magnetostrictive transducer system was used to excite and detect the guided waves. The applicability of the proposed approach for detecting and locating wire breakages was demonstrated for a cable with 37 wires. The present ultrasonic guided wave method has been found to be very responsive to the number of brokenwires and is thus capable of detecting defects with varying sizes.

Solar-powered multi-scale sensor node on Imote2 platform for hybrid SHM in cable-stayed bridge

  • Ho, Duc-Duy;Lee, Po-Young;Nguyen, Khac-Duy;Hong, Dong-Soo;Lee, So-Young;Kim, Jeong-Tae;Shin, Sung-Woo;Yun, Chung-Bang;Shinozuka, Masanobu
    • Smart Structures and Systems
    • /
    • 제9권2호
    • /
    • pp.145-164
    • /
    • 2012
  • In this paper, solar-powered, multi-scale, vibration-impedance sensor node on Imote2 platform is presented for hybrid structural health monitoring (SHM) in cable-stayed bridge. In order to achieve the objective, the following approaches are proposed. Firstly, vibration- and impedance-based hybrid SHM methods are briefly described. Secondly, the multi-scale vibration and impedance sensor node on Imote2-platform is presented on the design of hardware components and embedded software for vibration- and impedance-based SHM. In this approach, a solar-powered energy harvesting is implemented for autonomous operation of the smart sensor nodes. Finally, the feasibility and practicality of the smart sensor-based SHM system is evaluated on a full-scale cable-stayed bridge, Hwamyung Bridge in Korea. Successful level of wireless communication and solar-power supply for smart sensor nodes are verified. Also, vibration and impedance responses measured from the target bridge which experiences various weather conditions are examined for the robust long-term monitoring capability of the smart sensor system.

Performance of passive and active MTMDs in seismic response of Ahvaz cable-stayed bridge

  • Zahrai, Seyed Mehdi;Froozanfar, Mohammad
    • Smart Structures and Systems
    • /
    • 제23권5호
    • /
    • pp.449-466
    • /
    • 2019
  • Cable-stayed bridges are attractive due to their beauty, reducing material consumption, less harm to the environment and so on, in comparison with other kinds of bridges. As a massive structure with long period and low damping (0.3 to 2%) under many dynamic loads, these bridges are susceptible to fatigue, serviceability disorder, damage or even collapse. Tuned Mass Damper (TMD) is a suitable controlling system to reduce the vibrations and prevent the threats in such bridges. In this paper, Multi Tuned Mass Damper (MTMD) system is added to the Ahvaz cable stayed Bridge in Iran, to reduce its seismic vibrations. First, the bridge is modeled in SAP2000 followed with result verification. Dead and live loads and the moving loads have been assigned to the bridge. Then the finite element model is developed in OpenSees, with the goal of running a nonlinear time-history analysis. Three far-field and three near-field earthquake records are imposed to the model after scaling to the PGA of 0.25 g, 0.4 g, 0.55 g and 0.7 g. Two MTMD systems, passive and active, with the number of TMDs from 1 to 8, are placed in specific points of the main span of bridge, adding a total mass ratio of 1 to 10% to the bridge. The parameters of the TMDs are optimized using Genetic Algorithm (GA). Also, the optimum force for active control is achieved by Fuzzy Logic Control (FLC). The results showed that the maximum displacement of the center of the bridge main span reduced 33% and 48% respectively by adding passive and active MTMD systems. The RMS of displacement reduced 37% and 47%, the velocity 36% and 42% and also the base shear in pylons, 27% and 47%, respectively by adding passive and active systems, in the best cases.

HVDC 해저케이블의 연속허용전류 계산에 관한 연구 (A Study on the Calculation of Allowable Continuous Current for HVDC Submarine Power Cables)

  • 임충환;박흥석;문채주
    • 한국전자통신학회논문지
    • /
    • 제17권5호
    • /
    • pp.815-824
    • /
    • 2022
  • 해상풍력발전과 같은 간헐성 재생에너지원의 급격한 성장은 바다를 횡단하는 장거리의 전기에너지의 변환 필요성을 증가시키고 있다. 넓고 깊은 바다에 걸쳐서 장거리 대용량 전력송전을 위한 해법중의 하나는 HVDC 해저 전력케이블을 사용하는 것이다. 그러나 교류자계가 없는 직류전력 케이블의 다양한 해양조건을 갖는 연속허용전류와 관련한 표준이나 연구가 없다. 본 연구에서는 대표적인 두 종류의 해저케이블 모델과 남해안과 서해안 두 지역의 해양 요건을 가정하여 직류케이블의 연속허용전류를 모의하였다. 모의 결과를 보면 직류케이블의 연속허용전류는 해저 지반 깊이에 기반한 감소 구배 특성을 갖고 있는 것을 확인하였다.

A parametric analysis of the flutter instability for long span suspension bridges

  • Como, M.;Ferraro, S. Del;Grimaldi, A.
    • Wind and Structures
    • /
    • 제8권1호
    • /
    • pp.1-12
    • /
    • 2005
  • A simplified analysis able to point out the most relevant geometrical and aerodynamic parameters that can influence the flutter of long span modern bridges is the aim of the paper. With this goal, by using a continuous model of the suspension bridge and by a quasi stationary approach, a simple formula of the combined vertical/torsional flutter wind speed is given. A good agreement is obtained comparing the predictions from the proposed formula with the flutter speeds of three modern suspension or cable stayed bridges: the Great Belt East Bridge, the Akashi and Normandie bridges. The paper ends with some comments and comparisons with the well known Selberg formula.

진동 지반다짐 공법에 대한 장기간 진동계측 사례 (Vibration monitoring at Vibrating Compaction Works for Ground Improvement)

  • 김덕영;김선웅
    • 화약ㆍ발파
    • /
    • 제33권2호
    • /
    • pp.40-43
    • /
    • 2015
  • 본 연구에서는 싱가폴 창이 국제공항 신규 터미널(5번) 확장 지반 보강공사에 적용된 진동다짐공법을 소개하고 이에 따라 발생되는 진동을 장기간 실시간으로 측정하기 위하여 최적의 진동 분석 S/W 개발을 완료하였다. 아울러 이와 유사한 파일항타 작업 진동이나, 방파제 설계를 위한 주기적 반복적으로 발생하는 파도에 의한 진동이나 초고층 건물, 터널, 교량 등 대형구조물에서 발생하는 진동을 장시간에 걸쳐 실시간으로 측정이 가능함을 알아보고자 하였다.

다중 지진파 입력을 고려한 장대교량의 지진응답해석 (Earthquake Response Analysis of Long-Span Bridges with Multiple Input Motions)

  • 최준혁;최준성;이종세
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 추계 학술발표회논문집
    • /
    • pp.376-383
    • /
    • 2003
  • For more rational and economical seismic design of long span bridges, it is essential to include in the analysis the effects of multiple input motions and structural or soil nonlinearity which are not considered in the current design practice. In this paper, the effects of these factors on the seismic behavior of long span bridges are studied. First, for the effect of multiple input motions, we take into account the differences in arrival times of seismic waves. To consider nonlinear soil properties we utilize SHAKE which is based on the equivalent linearization method. As a numerical example, a cable-stayed bridge is modelled using the analytical procedures described above. It is shown from the results that the these factors influence the seismic response of the bridge significantly and should never be neglected in design.

  • PDF