• Title/Summary/Keyword: Long Life Test

Search Result 611, Processing Time 0.039 seconds

The study on Comparison Evaluation of Shear Bond Strength of Co-Cr Based Alloy using for Porcelain Fused Metal (도재용착주조관용 Co-Cr계 비귀금속 합금의 전단결합강도 비교평가에 관한 연구)

  • Kim, Hee-Jin;Kim, Bu-Sob
    • Journal of Technologic Dentistry
    • /
    • v.32 no.3
    • /
    • pp.195-207
    • /
    • 2010
  • Purpose: The purpose of this study was to observe the microstructural changes of surface in the specimens, performing the shear bond strength testing. The currently most used non-precious alloys are nickel-chromium based alloys with or without beryllium. However, their biocompatibility has been questioned concerning possible damages to the health of the patient and professionals involved in the fabrication of prosthesis caused by long exposure to Ni and Be. An option to nickel-chromium alloys is the cobalt-chromium alloy, an alternative that does not sacrifice the physical properties of the metal porcelain systems. Studies in the animals substantially show that the cobalt-chromium alloys are relatively well tolerated, being therefore more biocompatible than the nickel-chromium alloys. Methods: Non-addition Be to nickel-chromium based alloy(Bellabond plus) and cobalt-chromium alloy which has been widely used(Wirobond C) fused with ZEO light porcelain classified control group and cobalt-chromium alloy which is developing alloy of Alphadent company in Korea(Alphadent alloy) fused with ZEO light porcelain classified experimental group. The specimens of $4mm{\times}4mm{\times}0.5mm$ were prepared as-cast and as-opaque to cast body to analyze the mechanical characteristic change, the microstructure of alloy surface. The phase change was used to observe through XRD analysis and OM/SEM was used to observe the surface of specimens as-cast and as-opaque to cast body. Chemical formation of their elements was measured with EDS. Then hardness was measured with Micro Vicker's hardness tester. Shear bond strength test thirty specimens of $10mm{\times}10mm{\times}2mm$ was prepared, veneered, 3mm high and 3mm in diameter, over the alloy specimens. The shear bond strength test was performed in a universal testing machine(UTM) with a cross head speed of 0.5mm/min. Ultimate shear bond strength data were analyzed with one-way ANOVA and the Scheffe's test (P<0.05). Within the limits of this study, the following conclusions were drawn: The X-ray diffraction analysis results for the as-cast and as-opaque specimens showed that the major relative intensity of Bellabond plus alloy were changed smaller than Wirobond C and Alphadent Co-Cr based alloys. Results: Microstructural analysis results for the opaque specimens showed all the alloys increased carbides and precipitation(PPT). Alphadent Co-Cr based alloy showed the carbides of lamellar type. The Vickers hardness results for the opaque specimens showed Wirobond C and Alphadent Co-Cr based alloys were increaser than before ascast, but Bellabond plus alloy relatively decreased. The mean shear bond strengths (MPa) were: 33.11 for Wirobond C/ZEO light; 25.00 for Alphadent Co-Cr alloy/ZEO light; 18.02 for Bellabond plus/ZEO light. Conclusion: The mean shear bond strengths for Co-Cr and Ni-Cr based alloy were significantly different. But the all groups showed metal-metal oxide modes in shear bond strengths test at the interface.

LPI-based Assessment of Liquefaction Potential on the West Coastal Region of Korea (액상화 가능 지수를 이용한 국내 서해안 지역의 액상화 평가)

  • Seo, Min-Woo;Sun, Chang-Guk;Oh, Myoung-Hak
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.4
    • /
    • pp.1-13
    • /
    • 2009
  • Liquefaction is a significant threat to structures on loose saturated sandy soil deposits in the event of an earthquake, and can often cause catastrophic damage, economic loss, and loss of life. Nevertheless, the Korean peninsula has for a long time been recognized as a safe region with respect to the hazard of liquefaction, as the peninsula is located in a moderate seismicity region, and there have been no reports of liquefaction, with the exception of references in some historical documents. However, some earthquakes that have recently occurred in different parts of the world have led to liquefaction in non-plastic silty soils, a soil type that can be found in many of the western coastal areas of Korea. In this study, we first present procedures for evaluating the liquefaction potential, and calculate the liquefaction potential index (LPI) distribution at two western coastal sites using both piezocone penetration test (CPTu) data and standard penetration test (SPT) data. The LPI is computed by integrating liquefaction potential over a depth of 20m, and provides an estimate of liquefaction-related surface damage. In addition, we compared the LPI values obtained from CPTu and SPT, respectively. Our research found that the CRR values from CPTu were lower than those from the SPT, particularly in the range between 40 and 120 for the corrected tip resistance, (qc1N)CS, from the CPTu, or in the range of CRR less than 0.23, resulting in relatively high LPI values. Moreover, it was observed that the differences in the CRR between the two methods were relatively higher for soils with high fine contents.

Safety Test of Brown Rice Expressing Arabidopsis Calcium Transporter by Feeding Trial in Mice (애기장대 칼슘수송체를 발현하는 형질전환 현미의 생쥐 식이를 통한 안전성 평가)

  • Kim, Kyung-Min;Kim, Chang-Kil;Kim, Byung-Oh
    • Journal of Life Science
    • /
    • v.18 no.10
    • /
    • pp.1390-1394
    • /
    • 2008
  • Previously, we found that the transgenic rice plants over-expressing the Arabidopsis $H^+/Ca^{2+}$ antiporter CAX 1 (accession no. U57411) gene accumulated 2.7 to 7.5-fold more calcium in the T3 rice grains as compared to those of control. To examine physiological safety of the $T_3$ rice grains, the effect of the $T_3$ brown rice on change in levels of body weight and white blood cells was compared with that of the control Ilpum brown rice by feeding trial in mice. During the feeding trial for one month, there was no significant difference between two mice groups, which were fed by the $T_3$ brown rice or Ilpum brown rice. There were no detectable differences in their effects on immune functions including plaque-forming unit, peritoneal macrophage number, and NK-cell activity. In addition, biochemical analysis of the blood failed to exhibit any difference between two mice groups. Together, these results suggested that the $T_3$ brown rice, which was produced from a genetically modified organism (GMO), might be safe and possess a potential to be applicable as calcium-fortified feed or food. Long-term safety of the $T_3$ brown rice, however, remains to be elucidated.

Characterization of Bacillus polyfermenticus SCD for Oral Bacteriotherapy of Gastrointestinal Disorders (식품용 프로바이오틱 비스루트균의 주요 생균제 특성)

  • Paik, Hyun-Dong;Jung, Min-Yong;Jung, Hwang-Young;Kim, Won-Seok;Kim, Kee-Tae
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.1
    • /
    • pp.73-78
    • /
    • 2002
  • Bacillus polyfermenticus SCD, which is commonly called as Bisroot strain, is being used for functional foods through the treatment of long-term intestinal disorders, since the live strains in the form of active endospores can successfully reach the target intestine in both humans and animals. The cells of B. polyfermenticus SCD were treated for 24 h in artifical bile after incubation for 2 h in artificial gastric juice and final number of the strain was reached to around $3.3{times}10^7\;CFU/mL$. In test of API ZYM kit, ${\beta}-glucuronidase$ or ${\beta}-glucosidase$ was not produced by B. polyfermenticus SCD. B. polyfermenticus SCD was resistant to antibiotics, such as nisin, streptomycin, tetracycline, and rifamycin. B. polyfermenticus SCD was also affected by alcohol concentration up to 4%, but more than 8%, their growth was not affected significantly. Finally, B. polyfermenticus SCD was shown to inhibit the growth of Listeria monocytogenes ATCC 19111 completely within 24 h of incubation, which indicated its bactericidal nature.

Effects of Community-based Case Management Program for Clients with Hypertension (고혈압 대상자의 지역사회 중심 사례관리 프로그램 효과)

  • So, Ae-Young;Kim, Yun-Mi;Kim, Eun-Young;Kim, Chang-Yup;Kim, Cheol-Hwan;Kim, Hee-Gerl;Shin, Eun-Young;Yoo, Weon-Seob;Yi, Ggod-Me;June, Kyung-Ja
    • Journal of Korean Academy of Nursing
    • /
    • v.38 no.6
    • /
    • pp.822-830
    • /
    • 2008
  • Purpose: The purpose of this study was to analyze effects of a community-based case management program for clients with hypertension living in the community. Methods: The research design was a one group pre and post-test design with 30 participants with hypertension who agreed to participate in the 8-12 week case management program provided by case managers from the National Health Insurance Corporation in 2002. Data were collected three times, before and after the case management services, and 6 months later. Outcomes included changes in blood pressure, knowledge of hypertension and daily life practices, including alcohol consumption, smoking, exercise, and medication adherence. Results: Repeated-measures ANOVA and post-hoc tests of means revealed significant differences before and after service for systolic blood pressure, daily life practices (monitoring body weight and BP, low salt and cholesterol and high vegetable diet, and stress-relief practices), and exercise. The goal for medication adherence was attained after service. Significant improvements from baseline to 6 months after service were observed in measures of salt and vegetables in diet. There were no significant differences on hypertension knowledge, alcohol consumption or smoking behavior between before service and after, and at 6 months. Conclusion: The findings provide preliminary evidence that case management intervention can have positive outcomes on BP control, daily life practices, exercise, and medication adherence for clients with hypertension. However, additional interventions are needed to sustain long-term effects.

Vibration Characteristics of the Oriental Melon by Vibration Test (진동시험에 의한 참외의 진동특성)

  • Kim, Man-Soo;Jung, Hyun-Mo;Kim, Ghi-Seok;Park, Chung-Gil
    • Korean Journal of Agricultural Science
    • /
    • v.32 no.1
    • /
    • pp.29-42
    • /
    • 2005
  • During a long journey of agricultural products from the production area to markets, the quality of agricultural products was always affected by some degree of vibration. The vibration input during the transportation may cause serious agricultural product injury, and this damage is particularly severe whenever the vegetable inside package is free to bounce, and is vibrated at its resonant frequency. The objectives of this study were to determine the resonant frequency of the oriental melon and to investigate the relationships between resonant frequency and physical properties of the oriental melon such as mass, volume and major and minor axes. In this study vibration testing device was constructed to determine the vibration response of the oriental melon in frequency ranges of 5 to 150 Hz. The computer program for controlling the vibration shaker and the function generator and measuring the vibration characteristics of the oriental melon was developed. The ranges of resonant frequency and peak acceleration at resonance of the oriental melon were 51 to 73 Hz and 1.24 to 1.92 G-rms, respectively. The resonant frequency and the peak acceleration decreased with the increase of the sample mass, volume, major and minor axes of the oriental melon. Multiple regression models for resonant frequency and peak acceleration of the oriental melon as a function of mass, major axis and minor axis of the sample were developed and analyzed.

  • PDF

Clinical Experience of Long-term Home Oxygen Therapy (재택산소요법을 받고 있는 환자들에 대한 임상 관찰)

  • Lee, Young-Suk;Cha, Seung-Ick;Han, Chun-Duk;Kim, Chang-Ho;Kim, Yeun-Jae;Park, Jae-Yong;Jung, Tae-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.3
    • /
    • pp.283-291
    • /
    • 1993
  • Background: Long-term low flow oxygen therapy not only increases survival, but also improves the quality of life in patients with chronic obstructive pulmonary disease (COPD) with chronic hypoxemia. For the assessment and improvement of the status of home oxygen therapy, we analyzed clinical experience of 26 patients who have been administered low flow oxygen at home. Method: Twenty-six patients (18 men and 8 women) who have been received long-term oxygen therapy (LTOT) at home were examined. We reviewed physical characteristics, clinical history, pulmonary function test, ECG, arterial blood gas analysis, hemoglobin and hematocrit, types of oxygen devices, inhalation time per day, concentration of administered $O_2$, duration of $O_2$ therapy, and problems in the home oxygen therapy. Results: The underlying diseases of patients were COPD 14 cases, far advanced old pulmonary tuberculosis 9 cases, bronchiectasis 2 cases, and idiopathic pulmonary fibrosis 1 case. The reasons for LTOT at home were noted for cor pulmonale 21 cases, for dyspnea on exertion and severe ventilatory impairment 4 cases, and for oxygen desaturation during sleep 1 case. The mean values of aterial blood gas analysis before home oxygen therapy were $PaO_2$ 57.7 mmHg, $PaCO_2$ 48.2 mmHg, and $SaO_2$ 87.7%. And the mean values of each parameters in the pulmonary function test were VC 2.05 L, $FEV_1$ 0.92 L, and $FEV_1$/FVC% 51.9%. Nineteen patients have used oxygen tanks as oxygen devices, 1 patient oxygen concentrator, 2 patients oxygen tank and liquid oxygen, and other 4 patients oxygen tank together with portable oxygen. The duration of oxygen therapy was below 1 year in 3 cases, 1~2 years in 15 cases, 3~5 years in 6 cases, 9 years in 1 case, and 10 years in 1 case. All patients have inhalated oxygen with flow rate less than 2.5 L/min. And only 10 patients have inhalated oxygen more than 15 hours per day, but most of them short time per day. Conclusion: For the effective oxygen administration, it is necessary that education for long-term low flow oxygen therapy to patients, their family and neighbor should be done, and also the institutional backup for getting convenient oxygen devices is required.

  • PDF

Fire Detection Signal Processing Method Using an Optical Fiber Linear Detector and the Development of an Optical Signal Processing Test Module (광섬유선형감지기를 이용한 화재감지 신호처리방법 및 광신호처리 시험모듈 개발에 관한 연구)

  • Kim, Si-Kuk;Lee, Young-Sin;Kim, Dong-Eun;Lim, Woo-Sub;Lee, Chun-Ha
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.27-34
    • /
    • 2016
  • This paper studies a fire detection system using an optical fiber linear detector which can minimize damage from a fire by the most adaptable even in poor environmental conditions such as a tunnel or utility-pipe conduit vulnerable to fire. Using a strand of optical fiber, temperature can be displayed in intervals of meters and a fire can be detected remotely from a distance of several kilometers. Thanks to its strengths such as high reliability and long life, it is widely applied in harsh environments in the overseas. Therefore demands are expected to grow greatly in Korea as well. However, all optical signal drive and analysis module except for the optical fiber linear detector, tend to rely on import. Firstly this study deduced the location and the method of processing signals measuring temperature by using the optical fiber linear detector in order to develop a technology for a domestic model of fire detection system. Secondly this study designed and manufactured the optical analysis test module, and then we checked its performance.

Effect of Reflow Number and Surface Finish on the High Speed Shear Properties of Sn-Ag-Cu Lead-free Solder Bump (리플로우 횟수와 표면처리에 따른 Sn-Ag-Cu계 무연 솔더 범프의 고속전단 특성평가)

  • Jang, Im-Nam;Park, Jai-Hyun;Ahn, Yong-Sik
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.16 no.3
    • /
    • pp.11-17
    • /
    • 2009
  • The drop impact reliability comes to be important for evaluation of the life time of mobile electronic products such as cellular phone. The drop impact reliability of solder joint is generally affected by the kinds of pad and reflow number, therefore, the reliability evaluation is needed. Drop impact test proposed by JEDEC has been used as a standard method, however, which requires high cost and long time. The drop impact reliability can be indirectly evaluated by using high speed shear test of solder joints. Solder joints formed on 3 kinds of surface finishes OSP (Organic Solderability Preservation), ENIG (Electroless Nickel Immersion Gold) and ENEPIG (Electroless Nickel Electroless Palladium Immersion Gold) was investigated. The shear strength was analysed with the morphology change of intermetallic compound (IMC) layer according to reflow number. The layer thickness of IMC was increased with the increase of reflow number, which resulted in the decrease of the high speed shear strength and impact energy. The order of the high speed shear strength and impact energy was ENEPIG > ENIG > OSP after the 1st reflow, and ENEPIG > OSP > ENIG after 8th reflow.

  • PDF

Serum Leakage Control using PP/PDMS Composite Membrane (PP/PDMS 복합막을 이용한 혈청누출 제어)

  • 김기범;이삼철;정순량;정경락
    • Membrane Journal
    • /
    • v.10 no.1
    • /
    • pp.47-53
    • /
    • 2000
  • The artificial lung is a device used to replace the function of the lungs. The major function of the lung is to remove carbon dioxide from the venous blood and replace it with oxygen, or arterialize the blood. And the function of the artificial lung is to provide an adequate amount of oxygenated blood to all the tissues of body during the open heart surgery. Extracorporeal life support(ECLS or ECMO) is standard treatment for severe respiratory failure but poses many contributions to future lung transplantation. Artificial Lung or membrane oxygenators available today, based on microporous polypropylene fibers, are associated with two major problems. They require systemic anticoagulation of the patient and they allow serum leakage across the membrane from the blood side to the gas side during long-term use. We obtained newly fabricated polypropylene(PP)/polydimethylsiloxane(PDMS) membranes which combined PP membrane, a microporous support layer with PDMS, and we had investiaged a technique for minimizing serum lekage of polypropylene(PP) membrane. The gas permeability of each PP/PDMS membrane was almost constant before and after the whole blood test by Lee-White method, while that of PP membrane was significantly reduced. Therefore the PP/PDMS membrane could be prevented serum leakage of PP membrane. In addition, the gas permeability of $CO_2$ in PP/PDMS membrane was 11.5 times higher as compared with that of $O_2$.

  • PDF