• 제목/요약/키워드: Logarithmic Detector

검색결과 20건 처리시간 0.022초

A Fast RSSI using Novel Logarithmic Gain Amplifiers for Wireless Communication

  • Lee, Sung-Ho;Song, Yong-Hoon;Nam, Sang-Wook
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제9권1호
    • /
    • pp.22-28
    • /
    • 2009
  • This paper presents a fast received signal strength indicator (RSSI) circuit for wireless communication application. The proposed circuit is developed using power detectors and an analog-to-digital converter to achieve a fast settling time. The power detector is consisted of a novel logarithmic variable gain amplifier (VGA), a peak detector, and a comparator in a closed loop. The VGA achieved a wide logarithmic gain range in a closed loop form for stable operation. For the peak detector, a fast settling time and small ripple are obtained using the orthogonal characteristics of quadrature signals. In $0.18-{\mu}m$ CMOS process, the RSSI value settles down in $20{\mu}s$ with power consumption of 20 mW, and the maximum ripple of the RSSI is 30 mV. The proposed RSSI circuit is fabricated with a personal handy-phone system transceiver. The active area is $0.8{\times}0.2\;mm^2$.

Log-Normal Clutter 환경에서 차량용 UWB 단거리 레이더 수신기의 성능분석 (UWB Automobile Short Range Radar Receivers Performance In a Log-Normal Clutter Background)

  • 난데쉬;고석준
    • 대한전자공학회논문지TC
    • /
    • 제48권9호
    • /
    • pp.59-64
    • /
    • 2011
  • 초광대역 레이더는 높은 분해 능력으로 인해 단거리 차량용 레이더로 주목받고 있다. 차량으로부터 반사된 레이더 신호는 "clutter"라는 원하지 않는 반사 신호를 갖게 되어, 목표물을 검출하는데 어려움을 갖게 된다. 그러므로 목표물에서 반사된 신호로부터 보다 확실하게 검출하기 위하여 레이더 검출기를 개발할 필요가 있다. 본 논문에서는 log-normal clutter 환경에서 다양한 평균과 분산에서 최적인 검출기를 구하였다. 비동기 방식의 검출기로 자승 검출기와 선형 검출기, 로그 검출기 등을 분석하였다. 본 논문에서는 컴퓨터 시뮬레이션을 통해 검출기의 성능을 분석하여, 차량용 레이더로 최적인 검출기를 구하였다.

X-Band 트랜스폰더 수신기의 설계 및 제작 (Design and Implementation of Receiver for X-Band Transponder)

  • 이원우;조경준;김상희;김종헌;이종철;이병제;김남영
    • 한국전자파학회논문지
    • /
    • 제13권6호
    • /
    • pp.507-513
    • /
    • 2002
  • 본 논문에서는 헤테로다인 방식을 이용한 9.4 GHz 대역의 펄스레이다용 수신기를 설계 및 제작하였다. 펄스레이다용 헤테로다인 수신기에서 큰 부피를 차지하던 IF 증폭기를 제거하고 기저대역 부분에서 검출 로그 비디오 증폭기(Detecter logarithmic video amplifier)를 사용하여 소형화시켰으며 높은 선형 영역과 높은 수신감도를 얻도록 하였다. 측정결과, 최소수신전력 -70 dBm과 선택도 55 dB를 얻었다

대수수신계통의 탐색특성개선 (An Improvement in Detection Performance of Logarithmic Receiver)

  • 윤현보;장태무;조광래
    • 한국통신학회논문지
    • /
    • 제9권1호
    • /
    • pp.45-48
    • /
    • 1984
  • A serious degradation of blocking of the detection performance in a cell aeraging-logarithmic detector/constant false alarm rate(CA-LOG/CFAR) is known to be caused by the presence of a large interfering noise in the set of sample mean. A technique consisting of the logarithmic circuit and inverter has been proposed to alleviate this problem, by modifying the conventional CA-LOG/CFAR receiver. The detection performance of the proposed technique is linearly improbed over the normal output level and the blocking characteristics of the CA-LOG/CFAR can be changed to finite output level.

  • PDF

넓은 동작영역과 고속특성을 갖는 로그 증폭기의 설계 (Design of a wide dynamic range and high-speed logarithmic amplifier)

  • 박기원;송민규
    • 대한전자공학회논문지SD
    • /
    • 제39권7호
    • /
    • pp.97-103
    • /
    • 2002
  • 본 논문은 레이더 시스템이나 위성 통신용으로 사용되어지는 LVA(Logarithmic Video Amplifier) 설계에 관한 내용이다. 제안된 LVA는 입력단, 증폭단, 그리고 출력단으로 나뉘어진다. 넓은 동작 영역과 고속특성을 갖도록 새로운 직 ${\cdot}$ 병렬 구조를 제안하였으며 LVA와 전단인 Detector Diode와의 입력 범위 조절을 위하여 새로운 입력단을 설계하였다. 제안된 LVA는 1.5 um, 2-poly, 2-Metal, n-well, BiCMOS, 공정을 사용하였으며, 유효 칩 면적은 1310 um x 1540 um 고 10V 전압에서 190 mW 의 전력 소모를 나타내었다. 모의 실험 및 측정을 통하여 60 dB의 동작영역과 100 ns의 falling time을 나타내었다.

광대역 고감도 DLVA 개발

  • 이두훈;김상진;김재연;조현룡;이정문;김상기
    • 한국전자파학회지:전자파기술
    • /
    • 제11권4호
    • /
    • pp.39-52
    • /
    • 2000
  • A design of 2 stage S-DLVA(successive detector log video amplifier) was studied to detect wide dynamic radar pulse ranging from -70 ㏈m to 0㏈m. A basic design idea was focused on the linear detection in logarithmic scale of wide dynamic range radar pulses from nosie-like weak power of -70 ㏈m to relatively high power 0 ㏈m. It is highly formidable, since it requires high speed detection less than 10 nsec over the operating frequency ranges from 6 to 18 ㎓. A limiter diode, a tunnel diode and an L17-C were used as a protecting device, a detector diode and a log video amplifier in companion as a single stage detector to give voltage output proportional to the input power of about 35 ㏈ dynamic range. A protype of 2-stage DLVA having one more single stage detector was fabricated with a 32 ㏈ low noise amplifier and a 3 ㏈ hybrid coupler to provide total 70 ㏈ dynamic range detection. The logging characteristics were measured to have log slope of 25m.V/㏈ against 70 ㏈ logging range from -55 ㏈m to +15 ㏈m, the log linearity of within +/- 1.5 ㏈, and tangential sensitivity was at -63 ㏈m. The pulse dynamics of rise time and recovery time were measured as 50 nsec and 1.2 $\mu$sec, respectively. The reason might be due to the parasitic capacitances of packaged limiter, tunnel diode, and L17-C.

  • PDF

Neural-network-based Impulse Noise Removal Using Group-based Weighted Couple Sparse Representation

  • Lee, Yongwoo;Bui, Toan Duc;Shin, Jitae;Oh, Byung Tae
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제12권8호
    • /
    • pp.3873-3887
    • /
    • 2018
  • In this paper, we propose a novel method to recover images corrupted by impulse noise. The proposed method uses two stages: noise detection and filtering. In the first stage, we use pixel values, rank-ordered logarithmic difference values, and median values to train a neural-network-based impulse noise detector. After training, we apply the network to detect noisy pixels in images. In the next stage, we use group-based weighted couple sparse representation to filter the noisy pixels. During this second stage, conventional methods generally use only clean pixels to recover corrupted pixels, which can yield unsuccessful dictionary learning if the noise density is high and the number of useful clean pixels is inadequate. Therefore, we use reconstructed pixels to balance the deficiency. Experimental results show that the proposed noise detector has better performance than the conventional noise detectors. Also, with the information of noisy pixel location, the proposed impulse-noise removal method performs better than the conventional methods, through the recovered images resulting in better quality.

Exposure Index를 이용한 이동형 디지털 X선 장치의 흉부촬영 적정노출조건에 관한 연구 (A Study on the Proper Chest Exposure Conditions of Mobile Digital X-ray Unit by Exposure Index)

  • 김재인;이양섭;장동수;정민철;배승호;이관섭;하동윤
    • 대한디지털의료영상학회논문지
    • /
    • 제13권3호
    • /
    • pp.139-144
    • /
    • 2011
  • The purpose of this report is recommending a standard indicator which reflects the radiation exposure that is incident on a detector after every exposure event and that reflects the noise levels present in the image data. The experiment was performed with mobile digital X-ray unit and used a acrylic phantom for exposure index measurement. Exposure modality was kVp, mAs, SID. After every exposure, make a data sheet for characteristic curve of detector response. The equipment performed Mobile digital X-ray unit provide the user with values ralated to the incident exposure(air kerma)to the digital detector. They are showed as a logarithmic function shaped. As a result, DEI means a relative measure of exposure to the detector, as compared to the expected exposure for a particular anatomical view. Radiographic technique is the combination of factors used to exposure an anatomical part to produce a high quality radiography and technique charts used most commonly by radiographers to produce consistently exposure level which patient dose can be kept acceptably low.

  • PDF

테놀민 정(아테놀올 50 mg)에 대한 신일아테놀올 정의 생물학적 동등성 (Bioequivalence of Sinil Atenolol Tablets to Tenormin Tablets (Atenolol 50 mg))

  • 곽혜선;강성하;전인구
    • Journal of Pharmaceutical Investigation
    • /
    • 제33권1호
    • /
    • pp.51-53
    • /
    • 2003
  • This study was conducted to compare the bioavailability of a generic product of Sinil Atenolol Tablets (Sinil Pharmaceutical Co., Ltd., Korea) with the innovator product, $Tenormin^{\circledR}$ Tablets in 20 healthy Korean volunteers. The volunteers received a single 50 mg dose of each atenolol formulation according to a randomized, two-way crossover design. Plasma samples were obtained over a 24-hour interval, and atenolol concentrations were determined by HPLC with a fluorescence detector. From the plasma atenolol concentration vs time curves, the following parameters were compared: area under the plasma concentration-time curve (AUC), peak plasma concentration $(C_{max})$, time to reach peak plasma concentration $(T_{max})$, and terminal first order elimination half-life $(t_{1/2})$. No statistically significant difference was obtained between the $T_{max}$ values, and the logarithmic transformed AUC and $C_{max}$ values of the two products. The 90% confidence for the ratio of the logarithmically transformed AUC and $C_{max}$ values of Sinil Atenolol Tablets over those of $Tenormin^{\circledR}$ Tablets were calculated to be between 0.99 and 1.07, and 1.04 and 1.16, respectively; both were within the bioequivalence limit of 0.80-1.25. The mean of $T_{max}$ in $Tenormin^{\circledR}$ Tablet group was 3.68 hour, and that in Sinil Atenolol Tablet group was 3.65 hour. The values of $t_{1/2}$ between the two products were found comparable, and the mean $t_{1/2}$ values of $Tenormin^{\circledR}$ Tablets and Sinil Atenolol Tablets were 5.9 and 6.0 hour, respectively. Based on these results, it was concluded that Sinil Atenolol Tablets were comparable to $Tenormin^{\circledR}$ Tablets in both the rate and extent of absorption, indicating that Sinil Atenolol Tablets were bioequivalent to the reference product, $Tenormin^{\circledR}$ Tablets

Bioequivalence Evaluation of Two Atenolol Tablet Preparations in Korean Healthy Male Volunteers

  • Gwak, Hye-Sun;Chun, In-Koo
    • Biomolecules & Therapeutics
    • /
    • 제15권3호
    • /
    • pp.187-191
    • /
    • 2007
  • This study was conducted to compare the bioavailability of two brands of atenolol (50 mg) tablets, which are a generic product of $Ditent^{\circledR}$ (Daewon Pharmaceutical Co., Ltd., Korea) and an innovator product $Tenormin^{\circledR}$ (Hyundai Pharm. Ind. Co., Ltd., Korea), in 20 healthy Korean male volunteers. The volunteers received a single 50 mg dose of each atenolol formulation according to a randomized, two-way cross-over design. The washout period between treatments was 1 week. Plasma samples were obtained over a 24-hour interval, and atenolol concentrations were determined by HPLC with a fluorescence detector. From the plasma atenolol concentration vs. time curves, the following parameters were compared: area under the plasma concentration-time curve ($AUC_{0-24}$), peak plasma concentration ($C_{max}$), time to reach peak plasma concentration ($T_{max}$), and terminal first order elimination half-life ($t_{1/2}$). No statistically significant difference was obtained between the $T_{max}$ values, and the logarithmic transformed $AUC_{0-24}$ and $C_{max}$ values of the two products. The 90% confidence interval for the ratio of the logarithmically transformed AUC and $C_{max}$ values of $Ditent^{\circledR}$ over those of $Tenormin^{\circledR}$ were calculated to be between 0.85 and 1.04, and 0.89 and 1.07, respectively; both were within the bioequivalence limit of 0.80-1.25. The mean of $T_{max}$ in $Tenormin^{\circledR}$ group was 3.1 hour, and that in Ditent$^{\circledR}$ group was 3.2 hour. The values of $t_{1/2}$ between the two products were found comparable, and the mean values were 5.2 hour in the both products. Based on these results, it was concluded that $Ditent^{\circledR}$ was comparable to $Tenormin^{\circledR}$ in both the rate and extent of absorption, indicating that $Ditent^{\circledR}$ was bioequivalent to the reference product, $Tenormin^{\circledR}$.