• Title/Summary/Keyword: Lock-on

Search Result 884, Processing Time 0.042 seconds

A Study on the Operational Utilization Levels of Lock Gates in Incheon Port (인천항 갑문의 운영 수준에 관한 연구)

  • Koo, Ja-Yun
    • Journal of Navigation and Port Research
    • /
    • v.26 no.2
    • /
    • pp.177-182
    • /
    • 2002
  • In inner harbour of Incheon port, there are two lock gates (50KT, 10KT) which have two gates per lock gate in inner/outer sides except a gate in inner harbour side of 10KT. Due to the lack of the fore-mentioned gate, the use of 10KT lock gate is suspended in energy 3 years for regular maintenance. Now an additional gate is under construction in order to improve the efficiency of the 10KT lock gate. This paper will be aimed to evaluate the operational utilization levels of lock gates in present and future. The operational utilization levels of lock gates in 1998 are evaluated 0.2119 in 10KT lock gate, 0.2061 in 50KT lock gate which were considered the 46.5 closed days every 3 years for 10KT regular maintenance. The levels are estimated to 0.2246(10KT), 0.2539(50KT0 in 2006 and 0.2241(10KT), 0.2560(50KT) in 2011. The levels of 50KT lock gate in 2011 are evaluated to be more rapidly increased up to 24.5% from the levels in 1998.

An Analog Multi-phase DLL for Harmonic Lock Free (Harmonic Locking을 제거하기 위한 아날로그 Multi- phase DLL 설계)

  • 문장원;곽계달
    • Proceedings of the IEEK Conference
    • /
    • 2001.06b
    • /
    • pp.281-284
    • /
    • 2001
  • This paper describes an analog multi-phase delay-locked loop (DLL) to solve the harmonic lock problem using current-starved inverter and shunt-capacitor delay cell. The DLL can be used not only as an internal clock buffer of microprocessors and memory It's but also as a multi-phase clock generator for gigabit serial interfaces. The proposed circuit was simulated in a 0.25${\mu}{\textrm}{m}$ CMOS technology to solve harmonic lock problem and to realize fast lock-on time and low-jitter we verified time interval less than 40 ps as the simulation results.

  • PDF

Lock-on Characteristics of Wake Behind a Rotationally Oscillating Circular Cylinder (주기적으로 회전진동하는 원주 후류의 공진특성에 관한 연구)

  • Lee, Jung-Yeop;Lee, Sang-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.8 s.239
    • /
    • pp.895-902
    • /
    • 2005
  • Lock-on characteristics of flow around a circular cylinder oscillating rotationally with a relatively high forcing frequency have been investigated experimentally. Dominant governing parameters are Reynolds number (Re), angular amplitude of oscillation (${\theta}_A$), and frequency ratio $F_R=f_f/f_n,\;where\;f_f$ is a forcing frequency and $f_n$ is a natural frequency of vortex shedding. Experiments were carried out under the conditions of $Re=4.14{\times}10^3,\;{\pi}/90{\leq}{\theta_A}{\leq}{\pi}/3,\;and\;F_R=1.0$. The effect of this active flow control technique on the lock-on flow characteristics of the cylinder wake was evaluated with wake velocity measurements and spectral analysis of hot-wire signals. The rotational oscillation modifies the flow structure of near wake significantly. The lock-on phenomenon always occurs at $F_R=1.0$, regardless of the angular amplitude ${\theta}_A$. In addition, when the angular amplitude is less than a certain value, the lock-on characteristics appear only at $F_R=1.0$,. The range of lock-on phenomena expands and vortex formation length is decreased, as the angular amplitude increases. The rotational oscillation create a small-scale vortex structure in the region just near the cylinder surface. At ${\theta}_A=60^{\circ}$, the drag coefficient was reduced about $43.7\%$ at maximum.

Comparative Study of Current Limiting Characteristics for Hybrid Type and Flux-Lock Type SFCLs

  • Lim, Sung-Hun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.8 no.5
    • /
    • pp.222-225
    • /
    • 2007
  • In this paper, we compared the current limiting characteristics of both the hybrid type and the flux-lock type superconducting fault current limiters(SFCLs), which have a magnetic coupling structure between a primary winding and several secondary windings. The limiting impedances of two SFCLs were derived from each equivalent circuit considering the design parameters of SFCL such as the self-inductance of secondary winding and the resistance of $high-T_C$ superconducting(HTSC) element. Through the comparison for the limiting impedances of two SFCLs considering the dependence of the HTSC element's resistance on the applying voltage into the SFCL, the hybrid type SFCL was confirmed to have larger limiting impedance with smaller resistance of HTSC element than the flux-lock type SFCL. It was expected from the analysis that the hybrid type SFCL was more advantageous than the flux-lock type SFCL from the viewpoint of the fault current limiting level.

Development of a Lock-In Amplifier Array for Capacitive Type Pressure Mapping Sensor (정전용량 형 압력맵핑센서를 위한 록인 증폭기 어레이 개발)

  • Kim, Cheong-Worl;Lee, Young-Tae
    • Journal of the Semiconductor & Display Technology
    • /
    • v.16 no.4
    • /
    • pp.63-67
    • /
    • 2017
  • In this study, We developed a simple and low cost capacitive pressure mapping sensor and microcontroller-base lock-in amplifier array. We developed capacitive type pressure mapping sensor by forming the electrode and adhesives on plastic films using only the printing process, and the finishing the process by bonding the two films. Lock-in amplifier array was based on a general purpose microcontroller and had only a charge amplifier as analog circuits. In this study, a $10{\times}10$ capacitive type pressure mapping sensor and lock-in amplifier array was fabricated and its characteristics were analyzed.

  • PDF

A Study on Continued Usage of Mobile Telecommunication Companies by Killer-app Lock-in (킬러앱 고착화(Lock-in)로 인한 이동통신사의 지속적 사용의도에 관한 연구)

  • Lee, Jong-Oh;Han, Dong Gyun;Lee, Jong Gab;Lee, Sunro
    • Journal of Digital Convergence
    • /
    • v.12 no.6
    • /
    • pp.297-310
    • /
    • 2014
  • This study is about the influence between usages of smartphone by studying the characteristics of killer-app on smartphone in a perspective of switching cost and lock-in and studied about influence between killer-app and continued usage of mobile telecommunication companies. As a result of the study, information characteristics and network externality has a positive effect on switching cost and lock-in. Switching cost has a positive influence on lock-in but not on intention of continued usage of killer-app. It has shown that lock-in has a positive influence on intention of continued usage of killer-app and plays a mediating role between switching cost and continued usage of killer-app. Finally, intention of continued usage of killer-app has a positive influence on intention of continued usage of mobile telecommunication companies.

Theoretical Analysis of the Lock-on Range of a Man-portable Air Defense System Under Foggy Conditions with the Radiative-transfer Equation (복사전달방정식을 활용한 안개 조건에서의 휴대용 대공 유도미사일 Lock-on range에 대한 이론적 분석)

  • Seok, In Cheol;Lee, Chang Min;Hahn, Jae W.
    • Korean Journal of Optics and Photonics
    • /
    • v.30 no.1
    • /
    • pp.1-7
    • /
    • 2019
  • MANPADS (man-portable air defense system) is a counterweapon system against enemy aircraft, tracking the MWIR (mid-wavelength of infrared) signature of the plume. Under foggy conditions, however, multiple scattering phenomenon caused by the particles affects the MWIR transmittance, and the MANPADS detection performance. Therefore, in this study we analyzed the lock-on range of MANPADS with varying fog conditions and plume characteristics. To analyze the optical extinction properties and transmittance in fog, Mie scattering theory and analytic solution of the radiative-transfer equation are utilized. In addition, we used flare signature as an alternative MWIR light source. We confirmed that the lock-on range could be noticeably reduced under conditions of mist, and proportional to the flare temperature.

An Experimental Research on the Flexural Behavior of Concrete Beams with Lock Joint Coupler Bars (커플러 이음 철근을 사용한 철근콘크리트 보의 휨 거동에 대한 실험적 연구)

  • Park, Sun-Kyu;Lee, Kwal;Ko, Won-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.4 no.3
    • /
    • pp.197-204
    • /
    • 2000
  • Tensile strength (stress) of bar splice is important in the research of mechanical behavior of reinforced concrete structures-beam, column etc.- with bar splice. The purpose of this research is to evaluate the flexural behavior - deflection of beam specimens, strain of main bars - of reinforced concrete beam with Lock Joint Coupler. To make a comparative research, reinforced concrete beam specimens with normal deformed bar and lap splice are tested and analyzed. Test results, Comparing a deflection of three types flexural specimens, a flexural specimen with Lock Joint Coupler is 40% greater than the other flexural specimens. At the center of flexural specimen, the strain of main bar(D29) with lock joint coupler is 50% less, and vice versa, at the point of 14cm far from the center of flexural specimen, the strain of main bar(D29) with lock joint coupler is 9% larger than the strain of main bar(D29) which calculated using the classical flexure theory. A discords, between a deflection behavior of the flexural specimens and a strain of the main bar, are caused by the difference of strain between the lock joint coupler and main bar, near the lock joint coupler. So, additional research is need to verify as stated above discords.

  • PDF

Analysis of Operational Characteristics of Separated Three-Phase Flux-Lock SFCL (삼상 분리형 자속구속형 전류제한기의 동작 특성 분석)

  • Doo, Seung-Gyu;Du, Ho-Ik;Park, Chung-Ryul;Kim, Min-Ju;Kim, Yong-Jin;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.289-289
    • /
    • 2008
  • We investigated the operational characteristics of the separated three-phase flux-lock type superconducting fault current limiter (SFCL). The single-phase lock type SFCL consist of two coils, which are wound in parallel through an iron core. The high-$T_c$ superconducting(HSTC) thin film connected in series with secondary coil. The separated three-phase flux-lock type SFCL consist of three single-phase flux-lock type SFCL. In a normal condition, the SFCL is not operate. When a fault occurs, the current of a HSTC thin film exceeds its critical current by fault current, the resistance of the HSTC thin film generated. Therefore fault current was limited by SFCL. The separated three-phase flux-lock type SFCL are operated in fault condition such as the the single line-to-ground fault, the double line-to-ground fault and the triple line-to-ground fault. The experimental results, the SFCL operational characteristics was dependent on fault condition.

  • PDF

Adaptive Lock Escalation in Database Management Systems (데이타베이스 관리 시스템에서의 적응형 로크 상승)

  • Chang, Ji-Woong;Lee, Young-Koo;Whang, Kyu-Young;Yang, Jae-Heon
    • Journal of KIISE:Databases
    • /
    • v.28 no.4
    • /
    • pp.742-757
    • /
    • 2001
  • Since database management systems(DBMSS) have limited lock resources, transactions requesting locks beyond the limit mutt be aborted. In the worst carte, if such transactions are aborted repeatedly, the DBMS can become paralyzed, i.e., transaction execute but cannot commit. Lock escalation is considered a solution to this problem. However, existing lock escalation methods do not provide a complete solution. In this paper, we prognose a new lock escalation method, adaptive lock escalation, that selves most of the problems. First, we propose a general model for lock escalation and present the concept of the unescalatable look, which is the major cause making the transactions to abort. Second, we propose the notions of semi lock escalation, lock blocking, and selective relief as the mechanisms to control the number of unescalatable locks. We then propose the adaptive lock escalation method using these notions. Adaptive lock escalation reduces needless aborts and guarantees that the DBMS is not paralyzed under excessive lock requests. It also allows graceful degradation of performance under those circumstances. Third, through extensive simulation, we show that adaptive lock escalation outperforms existing lock escalation methods. The results show that, compared to the existing methods, adaptive lock escalation reduces the number of aborts and the average response time, and increases the throughput to a great extent. Especially, it is shown that the number of concurrent transactions can be increased more than 16 ~256 fold. The contribution of this paper is significant in that it has formally analysed the role of lock escalation in lock resource management and identified the detailed underlying mechanisms. Existing lock escalation methods rely on users or system administrator to handle the problems of excessive lock requests. In contrast, adaptive lock escalation releases the users of this responsibility by providing graceful degradation and preventing system paralysis through automatic control of unescalatable locks Thus adaptive lock escalation can contribute to developing self-tuning: DBMSS that draw a lot of attention these days.

  • PDF