• 제목/요약/키워드: Location distribution

검색결과 2,301건 처리시간 0.025초

행렬의 역정리를 이용한 전력공급 선로의 상간단락 사고지점 검출 방법 (A Novel Fault Location Method for a Line to Line Fault Using Inverse Theorem of Matrix on Electric Power Lines)

  • 이덕수;최면송;현승호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 춘계학술대회 논문집
    • /
    • pp.1321-1324
    • /
    • 2004
  • Unbalanced systems, such as distribution systems, have difficulties in fault locations due to single-phase laterals and loads. In this paper, a novel fault location algorithm is suggested for a line to line faults using inverse theorem of matrix on electric power lines. The fault location for balanced systems has been studied using the current distribution factor, by a conventional symmetrical transformation, but that for unbalanced systems has not been investigated due to their high complexity The proposed algorithms overcome the limit of the conventional algorithm using the conventional symmetrical transformation, which requires the balanced system and are applicable to any electric power system but are particularly useful for unbalanced distribution systems. The simulation results oriented by the real distribution system are presented to show its effectiveness and accuracy.

  • PDF

배전선로 고장점 표정 알고리즘 (A fault location algorithm for distribution feeder systems)

  • 이덕수;진보건;이승재;강상희;최면송;안복신;윤남선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.251-253
    • /
    • 2001
  • This paper presents a fault location algorithm for distribution feeder systems. Distribution feeders include single phase and three phase laterals. The proposed algorithm achieves a high accuracy by continuously updating voltage and current phasor using the symmetrical components and admittance load model.

  • PDF

Noninformative priors for the common location parameter in half-t distributions

  • Kang, Sang-Gil;Kim, Dal-Ho;Lee, Woo-Dong
    • Journal of the Korean Data and Information Science Society
    • /
    • 제21권6호
    • /
    • pp.1327-1335
    • /
    • 2010
  • In this paper, we want to develop objective priors for the common location parameter in two half-t distributions with unequal scale parameters. The half-t distribution is a non-regular class of distribution. One can not develop the reference prior by using the algorithm of Berger of Bernardo (1989). Specially, we derive the reference priors and prove the propriety of joint posterior distribution under the developed priors. Through the simulation study, we show that the proposed reference prior matches the target coverage probabilities in a frequentist sense.

전류분배계수를 사용하는 병행 2회선 송전선로 고장점 표정 알고리즘 (Current Distribution Factor Based Fault Location Algorithms for Double-circuit Transmission Lines)

  • 안용진;강상희;최면송;이승재
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권3호
    • /
    • pp.146-152
    • /
    • 2001
  • This paper describes an accurate fault location algorithm based on sequence current distribution factors for a double-circuit transmission system. The proposed method uses the voltage and current collected at only the local end of a single-circuit. This method is virtually independent of the fault resistance and the mutual coupling effect caused by the zero-sequence current of the adjacent parallel circuit and insensitive to the variation of source impedance. The fault distance is determined by solving the forth-order KVL(Kirchhoff's Voltage Law) based distance equation. The zero-sequence current of adjacent circuit is estimated by using a zero-sequence current distribution factor and the zero-sequence current of the self-circuit. Thousands of fault simulation by EMTP have proved the accuracy and effectiveness of the proposed algorithm.

  • PDF

기후변화에 따른 하수관거시설의 계획우수량 산정을 위한 일반극치분포 분석 (Analysis of Generalized Extreme Value Distribution to Estimate Storm Sewer Capacity Under Climate Change)

  • 이학표;류재나;유순유;박규홍
    • 상하수도학회지
    • /
    • 제26권2호
    • /
    • pp.321-329
    • /
    • 2012
  • In this study, statistical analysis under both stationary and non-stationary climate was conducted for rainfall data measured in Seoul. Generalised Extreme Value (GEV) distribution and Gumbel distribution were used for the analysis. Rainfall changes under the non-stationary climate were estimated by applying time variable (t) to location parameter (${\xi}$). Rainfall depths calculated in non-stationary climate increased by 1.1 to 6.2mm and 1.0 to 4.6mm for the GEV distribution and gumbel distribution respectively from those stationary forms. Changes in annual maximum rainfall were estimated with rate of change in the location parameter (${\xi}1{\cdot}t$), and temporal changes of return period were predicted. This was also available for re-evaluating the current sewer design return period. Design criteria of sewer system was newly suggested considering life expectance of the system as well as temporal changes in the return period.

자기단 전원 임피던스 추정 기법을 사용한 병행 2회선 송전선로 고장점 표정 알고리즘 (A Fault Location Algorithm Using Adaptively Estimated Local Source Impedance for a Double-Circuit Transmission Line System)

  • 박건호;강상희;김석일;신종한
    • 전기학회논문지
    • /
    • 제61권3호
    • /
    • pp.373-379
    • /
    • 2012
  • This paper presents a fault location algorithm based on the adaptively estimated value of the local sequence source impedance for faults on a parallel transmission line. This algorithm uses only the local voltage and current signals of a faulted circuit. The remote current signals and the zero-sequence current of the healthy adjacent circuit are calculated by using the current distribution factors together with the local terminal currents of the faulted circuit. The current distribution factors consist of local equivalent source impedance and the others such as fault distance, line impedance and remote equivalent source impedance. It means that the values of the current distribution factors can change according to the operation condition of a power system. Consequently, the accuracy of the fault location algorithm is affected by the two values of equivalent source impedances, one is local source impedance and the other is remote source impedance. Nevertheless, only the local equivalent impedance can be estimated in this paper. A series of test results using EMTP simulation data show the effectiveness of the proposed algorithm. The proposed algorithm is valid for a double-circuit transmission line system where the equivalent source impedance changes continuously.

Disruptive Factors and Customer Satisfaction at Chain Stores in Karachi, Pakistan

  • RASHID, Aamir;RASHEED, Rizwana;AMIRAH, Noor Aina;AFTHANORHAN, Asyraf
    • 유통과학연구
    • /
    • 제20권10호
    • /
    • pp.93-103
    • /
    • 2022
  • Purpose: This study aims to determine the relationship between disruptive factors and customer satisfaction at chain stores. Survey-based questionnaires were designed in the distribution technique to measure the findings in this study. Research design, data, and methodology: In terms of the sampling technique, the researchers adopted the simple random sampling technique with a total of 200 sample sizes. For the statistical method, the researchers applied multiple linear regression analysis to determine the potential factors that affect customer satisfaction at chain stores. The analysis of this study measured how product quality, pricing policies of chain stores, design and layout, responsiveness, and location of chain stores impart their roles in customer satisfaction. Results: This study found a significant relationship between the product quality and location of chain stores on customer satisfaction. In addition, the responsiveness, pricing policy, and physical design of chain stores impart an insignificant role in customer satisfaction. However, it is proven that the location of chain stores and product quality positively impact customer satisfaction. Conclusions: The study is geographically limited to the region of Karachi, Pakistan. Therefore, the findings may differ in the context of study implications in the other areas.

Sea state description of Asabo offshore in Nigeria

  • Jasper, Agbakwuru A.;Bernard, Akaawase T.;Gudmestad, Ove T.
    • Ocean Systems Engineering
    • /
    • 제10권1호
    • /
    • pp.25-47
    • /
    • 2020
  • A study of the wave conditions for the Asabo offshore location at the Qua Iboe oil field in Eastern Nigeria has been carried out. Statistical analysis was applied to three (3) years of data comprising spectral periods, Tp and significant wave heights, Hs. The data was divided into two (2); data from October to April represents one set of data and data from May to September represents another set of data. The results were compared with similar studies at other locations offshore of West Africa. It was found that there is an absence of direct swellwaves from the Southern Ocean reaching the location under study (the Asabo site). This work suggests that the wave system is largely emanating from the North Atlantic storms. The presence of numerous islands near the Asabo location shields the site from effects of storms from south west and therefore swells from the Southern Ocean. It is noted that the local wind has little or no contribution. An Hs maximum of 2 m is noted at the Asabo offshore location. It is found that the Weibull distribution best describes the wave distribution at Asabo. Thus, the Weibull distribution is suggested to be adequate for long term prediction of extreme waves needed for offshore design and operations at this location.

Single Line-to-ground Fault Location and Information Modeling Based on the Interaction between Intelligent Distribution Equipment

  • Wang, Lei;Luo, Wei;Weng, Liangjie;Hu, Yongbo;Li, Bing
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권5호
    • /
    • pp.1807-1813
    • /
    • 2018
  • In this paper, the fault line selection and location problems of single line-to-ground (SLG) fault in distribution network are addressed. Firstly, the adaptive filtering property for empirical mode decomposition is formulated. Then in view of the different characteristics showed by the intrinsic mode functions(IMF) under different fault inception angles obtained by empirical mode decomposition, the sign of peak value about the low-frequency IMF and the capacitance transient energy is chosen as the fault line selection criteria according to the different proportion occupied by the low-frequency components. Finally, the fault location is determined based upon the comparison result with adjacent fault passage indicators' (FPI) waveform on the strength of the interaction between the distribution terminal unit(DTU) and the FPI. Moreover, the logic nodes regarding to fault line selection and location are newly expanded according to IEC61850, which also provides reference to acquaint the DTU or FPI's function and monitoring. The simulation results validate the effectiveness of the proposed fault line selection and location methods.

배전계통 고장위치 확인을 위한 고장점 표정기법 (The Fault Distance Computation Method for Fault Location Identification of Distribution System)

  • 고윤석
    • 한국전자통신학회논문지
    • /
    • 제3권4호
    • /
    • pp.276-281
    • /
    • 2008
  • 배전계통은 여러 가지 이유로 잦은 고장을 경험하기 때문에 고장위치 추정은 전력공급 신뢰도 측면에서 매우 중요하다. 그렇지만 배전계통은 주 선로에서 분기되는 3상 및 단상 분기선을 가지는 수지상 구조로 설계되며 각 구간 상에 수개의 로드 탭을 가지기 때문에 고장점 표정이 어렵다. 따라서 본 연구에서는 기존의 전력계통 고장점 표정기법에 대해서 조사, 분석하여 배전자동화시스템의 중앙제어장치에서 효과적으로 실행할 수 있는 고장거리 계산 기법을 결정한다. 그리고 EMTP 모의 결과를 통해 결정된 방법의 유효성을 검증한다.

  • PDF