• Title/Summary/Keyword: Location Reference

Search Result 616, Processing Time 0.027 seconds

Improved LTE Fingerprint Positioning Through Clustering-based Repeater Detection and Outlier Removal

  • Kwon, Jae Uk;Chae, Myeong Seok;Cho, Seong Yun
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제11권4호
    • /
    • pp.369-379
    • /
    • 2022
  • In weighted k-nearest neighbor (WkNN)-based Fingerprinting positioning step, a process of comparing the requested positioning signal with signal information for each reference point stored in the fingerprint DB is performed. At this time, the higher the number of matched base station identifiers, the higher the possibility that the terminal exists in the corresponding location, and in fact, an additional weight is added to the location in proportion to the number of matching base stations. On the other hand, if the matching number of base stations is small, the selected candidate reference point has high dependence on the similarity value of the signal. But one problem arises here. The positioning signal can be compared with the repeater signal in the signal information stored on the DB, and the corresponding reference point can be selected as a candidate location. The selected reference point is likely to be an outlier, and if a certain weight is applied to the corresponding location, the error of the estimated location information increases. In order to solve this problem, this paper proposes a WkNN technique including an outlier removal function. To this end, it is first determined whether the repeater signal is included in the DB information of the matched base station. If the reference point for the repeater signal is selected as the candidate position, the reference position corresponding to the outlier is removed based on the clustering technique. The performance of the proposed technique is verified through data acquired in Seocho 1 and 2 dongs in Seoul.

Noninformative priors for the common location parameter in half-t distributions

  • Kang, Sang-Gil;Kim, Dal-Ho;Lee, Woo-Dong
    • Journal of the Korean Data and Information Science Society
    • /
    • 제21권6호
    • /
    • pp.1327-1335
    • /
    • 2010
  • In this paper, we want to develop objective priors for the common location parameter in two half-t distributions with unequal scale parameters. The half-t distribution is a non-regular class of distribution. One can not develop the reference prior by using the algorithm of Berger of Bernardo (1989). Specially, we derive the reference priors and prove the propriety of joint posterior distribution under the developed priors. Through the simulation study, we show that the proposed reference prior matches the target coverage probabilities in a frequentist sense.

자동 고장 판별 및 거리 측정 기능을 갖는 휴대용 케이블 고장 검출 장치 개발 (Development of Portable Cable Fault Detection System with Automatic Fault Distinction and Distance Measurement)

  • 김재진;전정채
    • 전기학회논문지
    • /
    • 제65권10호
    • /
    • pp.1774-1779
    • /
    • 2016
  • This paper proposes a portable cable fault detection system with automatic fault distinction and distance measurement using time-frequency correlation and reference signal elimination method and automatic fault classification algorithm in order to have more accurate fault determination and location detection than conventional time domain refelectometry (TDR) system despite increased signal attenuation due to the long distance to cable fault location. The performance of the developed system method was validated via an experiment in the test field constructed for the standardized performance test of power cable fault location equipments. The performance evaluation showed that accuracy of the developed system is less than 1.34%. Also, an error of automatic fault type and location by detection of phase and peak value through elimination of the reference signal and normalization of correlation coefficient and automatic fault classification algorithm not occurred.

심자도 센서의 위치 효과에 대한 연구 (Effect of the Sensor Location on Magnetocardiography)

  • 임현균;김기웅;권혁찬;이용호
    • Progress in Superconductivity
    • /
    • 제10권1호
    • /
    • pp.1-5
    • /
    • 2008
  • Magnetocardiography (MCG) is a non-contact, non-invasive, and harmless diagnostic tool to detect the abnormal electrical conductivities of the heart caused by the various coronary artery disease or cardiac muscular disease. The purpose of this study is to identify whether MCG signals and MCG parameter values vary depending on the location of sensor assembly. It will be an important reference for the standard measurement. Four healthy male subjects (33.3$\pm$6.3 years) participated in this study. Basal recording was made at 20 mm apart from the chest surface. All subjects were requested to take a regular breathe while MCG was taken. The gap between the chest surface and the bottom of the sensor assembly was 20, 40, 60, and 80 mm. Recording was made using 64 channel MCG system (Axial type, first order gradiometer) developed by Korea Research Institute of Standards and Science (KRISS). After resting for two minutes in a supine position on the bed in magnetically shielded room, MCG were recorded for 30 s. As the sensor location is getting away from the chest surface signal, the amplitude of R and T wave peak decreases to 70% (at 40 mm gap), 50% (at 60 mm), and 37% (at 80 mm) of the reference strength measured (y = $1.3903e^{-0.0169x}$, $R^2$ = 0.99; where y=amplitude remained after reduction, x=distance between chest surface and sensor location). The regression equations may be used as a good reference to calculate how much strength will be decreased by the distance. In MCG parameters, most values of parameters were decreased as the gap was increased. As an example, the current moment at T-wave peak reduced to 52% (at 40 mm gap), 33% (at 60 mm), and 19% (at 80 mm). However, the difference caused by the gap could be reduced by considering the distance when the MCG parameters were calculated. The study results can be used as a useful reference to design the baseline and the sensor location.

  • PDF

An Architecture and Protocol for Mobile Emergency Service

  • Jang Jeong-Ah;Choi Hae-Ock;Choi Wan-sik
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2005년도 Proceedings of ISRS 2005
    • /
    • pp.608-611
    • /
    • 2005
  • The existing wired emergency call such as 119, 112 have its own location information to serving immediate rescue service. For the case of wireless emergency call by mobile phone, the location information should be provided by wireless network. This paper describes the network architecture and protocol for mobile emergency service referring TIAlEWJ-SID-036-A with reviews about technical issues, legacy factors and related researches. The mobile emergency service is divided into mobile emergency rescue service and mobile emergency alert service. The network reference model for mobile emergency rescue service is released in KOREA. In this paper, the interfaces between elements of the network reference model, and service scenarios, message flows are defined. Supplement to mobile emergency rescue service, the network reference model, interfaces and message flows for mobile emergency alert service are developed. The protocol is described by DID, and the proposed works are on processing for domestic standard of TTA.

  • PDF

RFID를 이용한 이동체의 위치 결정에서 리더 태그간 인식율 연구 (A Study on Reader and Tag Sensing Rate of Location Detection Using RFID)

  • 전성희
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2007년도 하계종합학술대회 논문집
    • /
    • pp.33-34
    • /
    • 2007
  • LBS has many issues of wireless sensor networks and mobile communication parts. Location tracking or location sensing will be the opening of ubiquitous society's a big challenge and the beginning of infinite ubiquitous society's a chance. The purpose of this paper is study of sensing rate per reader antenna's placement and tag location and placement using RFID as location reference point with many advantages for location detection.

  • PDF

위치정보 제공 서비스를 위한 유비쿼터스 기준점 설계 연구 (Design of Ubiquitous Reference Point for Location Service)

  • 박재민;오윤석;강진아;김병국
    • Spatial Information Research
    • /
    • 제15권3호
    • /
    • pp.301-310
    • /
    • 2007
  • 현재 우리나라에는 전국에 약 21,000점의 측량용 국가기준점이 표석 형태로 매설되어 있으며, 대부분이 시통을 위해 산 정상에 매설되어 있어 일반인들의 사용과 접근이 어렵다. 최근 유비쿼터스 환경이 구축되어 감에 따라 위치정보 및 위치정보 기반의 정보를 일반인들에게 손쉽게 제공할 수 있는 서비스가 요구되고 있다. 본 연구에서는 RFID 태그와 2차원 바코드를 이용하여 위치정보를 손쉽게 제공할 수 있는 새로운 개념의 기준점 프로토타입을 제작하였다. 본 논문에서는 개발된 인텔리전트 기준점을 실용화하여 실제로 서비스하기 위해 필요한 사항에 대해 고려하여 보았으며, 실제 테스트를 통해 사용 가능성을 검증해보았다.

  • PDF

Objective Bayesian testing for the location parameters in the half-normal distributions

  • Kang, Sang-Gil;Kim, Dal-Ho;Lee, Woo-Dong
    • Journal of the Korean Data and Information Science Society
    • /
    • 제22권6호
    • /
    • pp.1265-1273
    • /
    • 2011
  • This article deals with the problem of testing the equality of the location parameters in the half-normal distributions. We propose Bayesian hypothesis testing procedures for the equality of the location parameters under the noninformative prior. The non-informative prior is usually improper which yields a calibration problem that makes the Bayes factor to be defined up to arbitrary constants. This problem can be deal with the use of the fractional Bayes factor or intrinsic Bayes factor. So we propose the default Bayesian hypothesis testing procedures based on the fractional Bayes factor and the intrinsic Bayes factors under the reference priors. Simulation study and an example are provided.

Extraction of location of 3-D object from CIIR method based on blur effect of reconstructed POI

  • Park, Seok-Chan;Kim, Seung-Cheol;Kim, Eun-Soo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.1363-1366
    • /
    • 2009
  • A new recognition method is used to find the three-dimensional target object on integral imaging. For finding the location of a target image, amount of reconstructed reference image is needed. This method is giving accurate information of target image by correlated among reconstructed target images and reference images.

  • PDF

상대적인 위치지각의 왜곡: 참조자극의 위치가 왜곡에 미치는 영향 (Relative localization errors: The effect of reference location on the errors)

  • Li, Hyung-Chul
    • 인지과학
    • /
    • 제15권3호
    • /
    • pp.15-24
    • /
    • 2004
  • 추적 눈 운동 동안에 순간적으로 노출되는 표적의 위치는 표적 주위에 참조자극이 존재하지 않을 때에 일반적으로 눈 운동 방향으로 왜곡되어 지각된다. 본 연구는 안정적이고 정적인 참조자극이 존재하는 경우에 순간적으로 노출되는 표적의 참조자극에 대한 상대적인 위치가 얼마나 정확하게 지각되는지를 검증하였다. 참조자극에 대한 표적의 상대적인 위치가 왜곡되게 지각되었으며 상대적인 위치 지각 왜곡의 양상이 참조자극과 표적의 상대적인 위치에 따라서 체계적으로 변화하였다. 동일한 실험결과가 추적 눈 운동의 방향이 상이하거나 참조자극과 표적의 다양한 물리적인 거리 조건에서도 일관되게 관찰되었다. 본 연구의 실험결과가 위치지각에 관하여 제안된 기존의 이론에 의해 어떻게 설명될 수 있는지를 논의하였다.

  • PDF