• 제목/요약/키워드: Local injection

검색결과 647건 처리시간 0.028초

수근관증후군에서 국소 스테로이드 주사 후 임상적, 전기생리학적 변화 (Clinical and Electrophysiological Changes after Local Steroid Injection in the Carpal Tunnel Syndrome)

  • 김지훈;이기욱;윤보라;김용덕;정언석;나상준
    • Annals of Clinical Neurophysiology
    • /
    • 제15권1호
    • /
    • pp.7-12
    • /
    • 2013
  • Background: Local steroid injection is used to treat carpal tunnel syndrome (CTS). The aim of this study was to evaluate the clinical and electrophysiological effects of local steroid injection in patients with CTS over a 3-months period. Methods: Twenty-one patients (35 hands) with clinical and electrophysiological evidence of CTS were treated by injection of triamcinolone 40 mg to the carpal tunnel. Visual analog scale (VAS), Boston Carpal Tunnel Questionnaire (BCTQ), rates of paresthesia, night awakening, and electrophysiological studies were used as outcomes. Clinical and electrophysiological assessments were performed before, 1 and 3 months after treatment. Results: Prior to treatment, 86% of patients complained of night awakening. At 1 and 3 months after injection, only 17% and 29% of the patients, respectively, had night awakening (p<0.001). All patients complained of paresthesia before the treatment. This symptom disappeared in 60% and 31% of the patients after 1 and 3 months, respectively (p<0.001). Compared to baseline, both BCTQ and VAS show significant improvement during the 3 months of the study (p<0.005). Although significant improvements in clinical parameters were shown, electrophysiological parameters were not significantly improved at 1 and 3 months. Conclusions: Local corticosteroid injection for the treatment of CTS provides significant improvement in symptoms for 3 months. On the other hand, no significant improvement was observed in electrophysiological parameters.

Effect of the new needle-free injection system on pain perception and dental anxiety during anesthesia: randomized controlled split-mouth study

  • Melek Belevcikli;Halenur Altan;Osman Demir
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제23권1호
    • /
    • pp.1-8
    • /
    • 2023
  • Backgrounds: Pain management is one of the most important factors affecting the success of pediatric dentistry. Therefore, new needle- and pain-free local anesthesia techniques have been developed in parallel with technological advancements. The purpose of this study is to compare the pain perception and dental anxiety levels associated with a needle-free injection system (Comfort-inTM) and the classic needle method during treatment-required infiltration anesthesia in children. Methods: This randomized controlled crossover split-mouth clinical study included 94 children who required dental treatment with local anesthesia using a dental needle or needle-free injection system for the bilateral primary molars. The Wong-Baker Scale (WBS) was used to measure pain perception at different times, and the Modified Child Dental Anxiety Scale (MCDAS) was used to measure the anxiety level of the child. A statistical software package was used to process the data. Statistical significance was set at P < 0.05. Results: There was no significant difference between the needle-free injection system and dental needle method during the induction stage for filling and pulpotomy (P > 0.05). "Pain on postoperative 1st day" was similar in both types of anesthesia (P = 0.750). Conclusions: The needle-free injection system was as effective as the dental needle method. The Comfort-inTM system was an acceptable alternative for patients during the postoperative period. Understanding how pain management may be provided during local anesthesia administration and a child's fear and anxiety regarding the dentist may lead to better dental compliance.

Buccal infiltration injection without a 4% articaine palatal injection for maxillary impacted third molar surgery

  • Sochenda, Som;Vorakulpipat, Chakorn;Kumar, K C;Saengsirinavin, Chavengkiat;Rojvanakarn, Manus;Wongsirichat, Natthamet
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제46권4호
    • /
    • pp.250-257
    • /
    • 2020
  • Objectives: Palatal infiltration is the most painful and uncomfortable anesthesia technique for maxillary impacted third molar surgery (MITMS). This approach could cause patients distress and aversion to dental treatment. The aim of this study was to evaluate the anesthetic efficacy of a buccal infiltration injection without a palatal injection in MITMS. Materials and Methods: This prospective research study was a crossover split mouth-randomized controlled trial. Twenty-eight healthy symmetrical bilateral MITMS patients (mean age, 23 years) were randomly assigned to two groups. Buccal infiltration injections without palatal injections were designated as the study group and the buccal with palatal infiltration cases were the control group, using 4% articaine and 1:100,000 epinephrine. The operation started after 10 minutes of infiltration. Pain assessment was done using a visual analogue scale and a numeric rating scale after each injection and extraction procedure. Similarly, the success rate, hemodynamic parameters, and additional requested local anesthetic were assessed. Results: The results showed that the pain associated with local anesthetic injections between both groups were significantly different. However, the success rates between the groups were not significantly different. Postoperative pain was not significant between both groups and a few patients requested an additional local anesthetic, but the results were not statistically significant. For hemodynamic parameters, there was a significant difference in systolic pressure during incision, bone removal, and tooth elevation. In comparison, during the incision stage there was a significant difference in diastolic pressure; however, other steps in the intervention were not significantly different between groups. Conclusion: We concluded that buccal infiltration injection without palatal injection can be an alternative technique instead of the conventional injection for MITMS.

Effectiveness of anterior middle superior alveolar injection using a computer-controlled local anesthetic delivery system for maxillary periodontal flap surgery

  • Tandon, Shruti;Lamba, Arundeep Kaur;Faraz, Farrukh;Aggarwal, Kamal;Ahad, Abdul;Yadav, Neha
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제19권1호
    • /
    • pp.45-54
    • /
    • 2019
  • Background: Profound anesthesia with adequate duration is required in periodontal flap surgery, which involves the manipulation of both hard and soft tissues. The anterior middle superior alveolar (AMSA) injection may be an alternative to multiple injections required for this purpose in the maxilla. The present study aimed to assess the effectiveness of AMSA injection using computer-controlled local anesthetic delivery (CCLAD) system to anesthetize buccal hard tissue (BHT), buccal soft tissue (BST), palatal hard tissue (PHT), and palatal soft tissue (PST) around the maxillary teeth. Methods: Thirty-five patients who were indicated for open flap debridement in a whole maxillary quadrant were given AMSA injection using the CCLAD. The effectiveness of anesthesia was evaluated using subjective and objective parameters around each tooth. Supraperiosteal infiltrations were administered to complete the surgery wherever the AMSA injection was ineffective. Results: The AMSA injection was more effective on the palatal tissues than on the buccal tissues, as 94.14% of PST and 87.89% of PHT sites were anesthetized compared to 49.22% and 43.75% of BHT and BST sites, respectively. There was no significant difference in the frequency of anesthesia around the anterior and posterior teeth. The PHT was significantly more anesthetized (P = 0.003) in males than in females. Conclusions: The AMSA injection using CCLAD is highly effective on palatal tissues and could be used as a first-line anesthesia for periodontal flap surgery. However, its effect on buccal tissues is less predictable, with supraperiosteal infiltration often required to supplement the AMSA injection.

DA-3585(recombinant human erythropoietin)의 국소자극성에 관한 연구 (Studies on Local Irritation of DA-3585, A Recombinant Human Erythropoietin, in Rabbits)

  • 조현;김동환;강경구;박장현;이성희;김원배
    • Toxicological Research
    • /
    • 제14권3호
    • /
    • pp.393-400
    • /
    • 1998
  • As a series of safety studies on DA-3585, a recombinant human erythropoietin, its local irritancy was examined in rabbits after the following treatments; application into the conjunctival sac of the eye(single), subcutaneous injection (single and -day repeated)and intravenous injection (7-day repeated.)In addition, perivascular irritation of DA-3585 was investigated in mice. In the result of ocular irritation test, 10,000IU/ml solution of DA-3585 could be considered as a non-irritating material. The local irritation of DA-3585 by a single and 7-day repeated subcutaneous injection was negligible and not so much different from that of saline. In the vascular irritancy test, macro-and microscopic observations revealed that local irritation of DA-3585 was comparable to that of saline when injected into retroauricular vein of rabbits for 7 consecutive days. Furthermore the perivascular administration of DA-3585 upto the concentration of 10,000 IU/ml did not induce any morphological abnormalities at injection sites. The results obtained from the present study suggest that the local irritancy of DA-3585 is not different from that of saline when injected through intravenous or subcutaneous route for clinical practice.

  • PDF

고분자용액에 의한 유체수송관벽의 저항감소 -II. 난류흐름에서 국소저항감소- (Drag Reduction of Pipe Wall For Fluid Flow due to Injected Polymer Solution - II. Local Drag Reduction in Turbulent Flow-)

  • 추낙준;유경옥
    • 한국화재소방학회논문지
    • /
    • 제5권2호
    • /
    • pp.11-20
    • /
    • 1991
  • Dilute polymer solutions were injected into turbulent pipe flow of a Newtonian fluid. The local drag reduction for injection of polymer solution at the pipe wall was larger than that at centerline. From the above result we may conclude that the polymer additives were found to influence the flow in the neighborhood of the wall. The effects of the injection apparatus on the local drag reduction are small compared to the drag-reducing effects. The extent of drag reduction increased with polymer concentration and injection flow rate, and the maximum drag reduction obtained were 47% for Polyox Coagulant and 35% for Separan AP-273. In respect to polymer degradation, the polyacrylamide showed better shear stability than the polyethyleneoxide and thus the former expected to have a sharper molecular weight distribution.

  • PDF

치과용 Lidocaine 28 앰플로 국소마취 하에 1차 봉합한 악안면 심부 관통성 열창 -증례 보고- (Primary Closure of Deep Penetrating Wounds under Local Anesthesia with Dental Lidocaine HCL 28 Ampules in Maxillofacial Regions -Report of two cases -)

  • 김종배;유재하
    • 대한치과마취과학회지
    • /
    • 제1권1호
    • /
    • pp.26-31
    • /
    • 2001
  • The wide deep penetrating wound of maxillofacial region should be early closed under emergency general anesthesia for the prevention of complications of bleeding, infection, shock & residual scars. But, if the emergency general anesthesia wound be impossible because of pneumoconiosis, obstructive pulmonary disease & hypovolemic shock, early primary closure should be done under local anesthesia by use of much amount of the anesthetic solution. The maximum dose of dental lidocaine (2% lidocaine with 1 : 100,000 epinephrine) is reported to 7 mg/kg under 500 mg (13.8 ampules) in normal adult. But the maximum permissible dose of dental lidocaine can be changed owing to the general health, rapidity of injection, resorption, distribution & excretion of the drug. The blood level of overdose toxicity is above $4.0{\mu}g/ml$ in central nervous & cardiovascular system. The injection of dental lidocaine 1-4 ampules is attained to the blood level of $1{\mu}g/ml$ in normal healthy adult. The duration of anesthetic action in the dental 2% lidocaine hydrochloride with 1 : 100.000 epinephrine is 45 to 75 minutes and the period to elimination is about 2 to 4 hours. Therefore, authors selected the following anesthetic methods that the first injection of 6 ampules is applied into the deeper periosteal layer for anesthetic action during 1 hour, the second injection into the deeper muscle & fascial layer, the third injection into the superficial muscle and fascial layer, the fourth injection into the proximal skin & subcutaneous tissue and the fifth final injection into the distal skin & subcutaneous tissue. The total 26-28 ampules of dental lidocaine were injected into the wound as the regular time interval during 5-6 hours, but there were no systemic complications, such as, agitation, talkativeness, convulsion and specific change of vital signs and consciousness.

  • PDF

분사 압력에 따른 수소 제트의 형상과 LIBs를 적용한 국부 당량비 계측 (Hydrogen Jet Structure and Measurement of Local Equivalence Ratio by LIBs under the Different Injection Pressure)

  • 이상욱;김정호;배충식
    • 한국분무공학회지
    • /
    • 제27권2호
    • /
    • pp.84-93
    • /
    • 2022
  • To implement carbon-neutrality in transportation sectors until 2050, hydrogen is considered a promising fuel for internal combustion engines because hydrogen does not contain carbon itself. Although hydrogen does not emit CO2 emission from its combustion process, the low energy density in a volume unit hinders the adoption of hydrogen. Therefore, the understanding of hydrogen jet behavior and measurement of equivalence ratio must be conducted to completely implement the high-pressure hydrogen direct injection. The main objective of this research is feasibility test of hydrogen local equivalence ratio measurement by laser-induced breakdown spectroscopy (LIBs). To visualize the macroscopic structure of hydrogen jet, high-speed schlieren imaging was conducted. Moreover, LIBs has been adopted to validate the feasibility of hydrogen local equivalence ratio measurement. The hydrogen injection pressure was varied from 4 MPa to 8 MPa and injected in a constant volume chamber where the ambient pressure was 0.5 MPa. The increased injection pressure extends the vertical penetration of hydrogen jet. Due to the higher momentum supply when the injection pressure is high, the hydrogen has easily diffused in all directions. As the laser trigger timing has delayed, the low hydrogen atomic emission was detected due to the longer mixture formation time. Based on equivalence ratio measurement results, LIBs could be applied as a methodology for hydrogen local equivalence ratio measurement.

치과용 국소마취제에 포함된 Epinephrine이 당뇨 환자의 소수술시 혈당에 미치는 영향에 관한 연구 (A STUDY ON THE INFLUENCE OF EPINEPHRINE CONTAINED IN DENTAL LOCAL ANESTHETIC AGENTS ON THE BLOOD SUGAR OF DIABETES DURING MINOR ORAL SURGERY)

  • 윤형진;임재석
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제27권5호
    • /
    • pp.463-471
    • /
    • 2005
  • Recently, the number of diabetic patients have been increased with westernized living way and meal habitation. The regulation of blood sugar concentration is very important for diabetic patients to keep homeostasis and, to prevent acute or chronic complications. Epinephrine combined with lidocaine is used in dental clinic extensively. And epinephrine combined with lidocaine also effects on decreasing the blood leakage volume by constricting micro vessle and arteriole. But, So far there are few researches about the effect of epinephrine contained in dental local anesthetic agent on the blood sugar of diabetes during minor oral surgery. The purpose of this study was intended to investigate whether epinephrine which combined with dental local anesthetics influence body glucose level in diabetes patients by glucose monitoring. The subject of this study were 38 diabetic patients and 38 normal adults, each patient was checked body glucose after a meal 2 hours later with resting state, and injection 1:100000 epinephrine with dental lidocaine 54 ml or lidocaine 54 ml only. And then the body glucose level was checked 5 minutes and 30 minutes after injection. The results were analyzed by two way ANOVA test (p<0.05). The results were as follows: In the experimental group 1, the mean of the blood sugar level was 180.3 mg/dl before an anesthetic injection, 182.8 mg/dl after 5minutes of the anesthetic injection and 182.2 mg/dl after 30minutes of the anesthetic injection. The change of the blood sugar level was not statistically by two-way ANOVA tests (p<0.05). In the experimental group 2, the mean of the blood sugar level was 237 mg/dl before an anesthetic injection, 234.5 mg/dl after 5minutes of the anesthetic injection and 231.8 mg/dl after 30minutes of the anesthetic injection. The change of the blood sugar level was not statistically by two-way ANOVA tests (p<0.05). In the controlled group 1, the mean of the blood sugar level was 117.6 mg/dl before an anesthetic injection, 119.1 mg/dl after 5minutes of the anesthetic injection and 129.3 mg/dl after 30minutes of the anesthetic injection. The change of the blood sugar level was not statistically by two-way ANOVA tests (p<0.05). In the controlled group 2, the mean of the blood sugar level was 104.2 mg/dl before an anesthetic injection, 102 mg/dl after 5minutes of the anesthetic injection and 105.3 mg/dl after 30minutes of the anesthetic injection. The change of the blood sugar level was not statistically by two-way ANOVA tests (p<0.05).

국부 가열 금형을 이용한 플라스틱 나노 구조표면 사출성형 연구 (A Study on Plastic Injection Molding of NanosStructured Surface with a Local Mold Heating System)

  • 라문우;박장민;김동언
    • 한국기계가공학회지
    • /
    • 제14권4호
    • /
    • pp.8-13
    • /
    • 2015
  • In this study, we fabricated and characterized a nanostructured surface based on a plastic injection molding with a local mold heating (LMH) system. A metal mold core with a closed packed nano convex array (CVA) was achieved by integrated engineering procedures: (1) master template fabrication by anodic aluminum oxidation (AAO), (2) nickel electroforming (NE) process, and (3) post-processing by precision machining. The nickel mold core was utilized to replicate a surface with a closed packed nano concave-array (CCA) based on injection molding using cyclic olefin copolymer (COC) as a plastic material. In particular, an LMH system was introduced to enhance transcription quality of the nano structures by delaying solidification of molten polymer near the surface of the mold core.