• Title/Summary/Keyword: Local flow analysis

Search Result 623, Processing Time 0.026 seconds

Improve the Quality of Public Medical Centers for the Static, Dynamic Efficiency Analysis (공공의료기관의 품질향상을 위한 정태적.동태적 분석)

  • Moon, Jae-Young;Kim, Yong-Tea
    • Journal of Korean Society for Quality Management
    • /
    • v.38 no.3
    • /
    • pp.393-407
    • /
    • 2010
  • The purpose of this study is to analysis relative efficiency and efficiency in process of time. Thus we use panel data of 34 local public medical centers between 2003 and 2005 to use DEA and Malmquist analysis. The result of our this study is as flow; first, The results of static efficiency of 34 local public medical centers show 10 CCR model and 23 BCC model which is difference of efficiency by economic of scale. Second, a cause of increased efficiency is not only change of technology but also change of efficiency to management system index show between 2003 and 2005 by Malmquist analysis and contracting-out is higher than direct management between 2004 and 2005. That means efficiency of local public medical centers is their own effort and innovation not government subsidies.

A Study on the Combustion Characteristics of Swirling Jet Combustor (선회분류 연소기의 연소특성에 관한 연구)

  • 심순용;손강호;이창식
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.2
    • /
    • pp.492-501
    • /
    • 1994
  • This study is an analysis of the turbulent diffusion flame with swirl flow and the calculated results are compared with experimental data in case of various swirl numbers and air-fuel rations. The mathematical model is restricted to single-phase, diffusion controlled combustion with swirl flow. Values of local flow properties were obtained by solving appropriate differential equation for continuity, momentum, stagnation enthalpy, concentration, turbulence energy, dissipation rate of turbulence energy, and the mean square of concentration fluctuation. The method is proposed for calculating the local probability of chemical reaction based on the use of the probability density function for the mixture fraction.

Numerical Analysis of Ship Local Resistance (선체 국소 저항 수치 해석)

  • Park, Dong-Woo;Seo, Jang-Hoon;Yoon, Hyun-Sik;Chun, Ho-Hwan;Jung, Jae-Hwan;Kim, Mi-Jeong
    • Journal of Ocean Engineering and Technology
    • /
    • v.26 no.6
    • /
    • pp.74-79
    • /
    • 2012
  • The present study aims at suggesting the systematic approach to analyze the local drag components as the resistance performance characterized by the flow of the ship. In order to identify the local areas, the hull surface is decomposed into SVM (Station-Vertical Section Map) which consists of 20 stations along the longitudinal direction and 20 sections along the vertical direction (from the bottom to the waterline). Successively, on the SVM, the friction and pressure drag coefficients as the components of total drag coefficient have been analyzed for two different hull forms of Wigley and KVLCC by using CFD.

A Study on the Effect of the Atmospheric Pressure in the Gas Flow Measurement (대기압이 가스유량측정에 미치는 영향에 관한 연구)

  • Chung, Jong-Tae;Ha, Young-Cheol;Lee, Cheol-Gu;Her, Jae-Young
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.363-369
    • /
    • 2002
  • Orifice meter is the most widely used flowmeter in custody transfer between KOGAS and city gas companies. Absolute pressure value is needed to calculate the gas flow of orifice metering system, but the gauge pressure transmitters are mainly used in the field. In case that the gauge pressure transmitters are used, the fixed value as standard atmospheric pressure(101.325kPa) is applied for the absolute pressure value. The real, local atmospheric pressures of each metering station are different from the standard condition as the altitude and weather conditions. In this study the flow calculation errors were quantitatively analyzed through examining the atmospheric pressures of 50 stations of KOGAS. The data for analysis are such like the time data of supplied gas amount, the altitude of each metering station, the time data of atmospheric pressures and altitudes of each weather observatory. The results showed that the local atmospheric pressures were different from the standard value and the gas flow calculation errors were distributed between $-0.024\%{\~}0.025\%$ based on the supplied gas amount in the year 1999 and 2000.

  • PDF

Study on Design Parameters in a Stamping Process of an Automotive Member with the Simulation-based Approach (해석적인 방법을 이용한 복잡한 형상의 자동차 부재 스탬핑 공정에서의 주요 설계인자 연구)

  • Song J. H.;Kim S. H.;Kim S. H.;Huh H.
    • Transactions of Materials Processing
    • /
    • v.14 no.1 s.73
    • /
    • pp.21-28
    • /
    • 2005
  • This paper is concerned with the quantitative effect of design parameters on a stamped part of the auto-body. The considered parameters in this paper are the blank holding force, the draw-bead force, the blank size which greatly affect the metal flow during stamping. The indicators of formability selected in this paper are failures such as tearing, wrinkling and the amount of springback. The stamping process of the front side inner member is simulated using the finite element analysis changing the design parameters. The numerical results demonstrate that the blank holding force cannot control the local metal flow during forming although it controls the overall metal flow. The modification of the initial blank size considering the punch opening line ensures the local wrinkling and reduces the amount of springback after forming. The restraining force of draw-bead controls the metal flow in the local area and reduces the amount of excess metal. It is noted that the parametric study of design parameters such as blank holding force, the blank size and the draw-bead are very important in the process design of the complicated member.

Development of the Interfacial Area Concentration Measurement Method Using a Five Sensor Conductivity Probe

  • Euh, Dong-Jin;Yun, Byong-Jo;Song, Chul-Hwa;Kwon, Tae-Soon;Chung, Moon-Ki;Lee, Un-Chul
    • Nuclear Engineering and Technology
    • /
    • v.32 no.5
    • /
    • pp.433-445
    • /
    • 2000
  • The interfacial area concentration (IAC) is one of the most important parameters in the two-fluid model for two-phase flow analysis. The IAC can be measured by a local conductivity probe method that uses the difference of conductivity between water and air/steam. The number of sensors in the conductivity probe may be differently chosen by considering the flow regime of two-phase flow. The four sensor conductivity probe method predicts the IAC without any assumptions of the bubble shape. The local IAC can be obtained by measuring the three dimensional velocity vector elements at the measuring point, and the directional cosines of the sensors. The five sensor conductivity probe method proposed in this study is based on the four sensor probe method. With the five sensor probe, the local IAC for a given referred measuring area of the probe can be predicted more exactly than the four sensor probe. In this paper, the mathematical approach of the five sensor probe method for measuring the IAC is described, and a numerical simulation is carried out for ideal cap bubbles of which the sizes and locations are determined by a random number generator.

  • PDF

Measurement of Local Heat Transfer Coefficients and Numerical Analysis in the Flow Passage of Disc Brake with Spirally Grooved Surfaces (나선형 홈을 가진 브레이크 유로 내에서의 국소 열전달 측정 및 열 유동 해석)

  • Lee, D.H.;Park, S.B.;Lim, C.Y.;Kim, H.S.;Lee, K.S.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.6
    • /
    • pp.104-111
    • /
    • 2006
  • A ventilated disc brake having spirally fluted surface has been proposed to improve the thermal judder by way of heat transfer enhancement. The local heat transfer coefficients were measured in the flow passage of disc brake. These measured local heat transfer data were utilized to do the finite element numerical analysis which predicts the maximum temperatures on the disc brake. The results show that the maximum temperatures on the disc surface with spirally fluted surface are approximately 26.6% lower than those without them.

Analysis of mixed convective laminar flow and heat transfer about a sphere (혼합대류에 의한 구 주위의 충류유동 및 열전달 해석)

  • 이준식;김택영
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.2
    • /
    • pp.345-353
    • /
    • 1987
  • An analysis is performed to study flow and heat transfer characteristics of mixed free and forced convection about a sphere. Nonsimilar boundary layer equations which are valid over the entire regime of mixed convection are derived in terms of the mixed convection parameter, Gr/Re$^{2}$, through a dimensional analysis. The transformed conservation equations are solved by a finite difference method for the whole range of mixed convection regime. Numerical results for fluids having the Prandtl number 0.7 and 7 are presented. As the mixed convection parameter increases, the local friction coefficient and local heat transfer coefficient increases as well. For small Prandtl number, the friction coefficient is larger, while for large Prandtl number, the heat transfer coefficient is larger. Natural convection effect on the forced flow is more sensitive for small Prandtl number fluid. Flow separation migrates rearward as an increase in the mixed convection parameter. For small Prandtl number, the buoyancy effect is relatively small so that the flow separation occurs earlier.

FLOW-3D Analysis on Scouring around Offshore Wind Foundation (FLOW-3D를 이용한 해상풍력발전기초의 세굴 평가)

  • Oh, Myoung-Hak;Kwon, O-Soon;Jeong, Weon-Mu;Lee, Kwang-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.3
    • /
    • pp.1346-1351
    • /
    • 2012
  • In order to evaluate the local scour around offsshore wind foundation, mono pile and jacket foundation were simulated by using FLOW-3D. Numerical analysis results show that local increases of velocity around mono pile and jacket foundation was developed but velocity decreases in backward of pile and leg due to the wake vortex was observed. Local increases of velocity around foundation and scouring of jacket is more significant than that of mono pile, since jacket is the complex structure and has the interference effect with legs. Therefore, in order to evaluate the scour and design the scour protection method, the form and shape of substructures of offshore wind should be considered.

Predictions of non-uniform tip clearance effects on the flow field in an axial compressor

  • Kang, Young-Seok;Kang, Shin-Hyoung
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.743-750
    • /
    • 2008
  • Asymmetric tip clearance in an axial compressor induces pressure and velocity redistributions along the circumferential direction in an axial compressor. This paper presents the mechanism of the flow redistribution due to the asymmetric tip clearance with a simple numerical modeling. The flow field of a rotor of an axial compressor is predicted when an asymmetric tip clearance occurs along the circumferential direction. The modeling results are supported by CFD results not only to validate the present modeling but also to investigate more detailed flow fields. Asymmetric tip clearance makes local flow area and resultant axial velocity vary along the circumferential direction. This flow redistribution 'seed' results in a different flow patterns according to the flow coefficient. Flow field redistribution patterns are largely dependent on the local tip clearance performance at low flow coefficients. However, the contribution of the main flow region becomes dominant while the tip clearance effect becomes weak as the flow coefficient increases. The flow field redistribution pattern becomes noticeably strong if a blockage effect is involved when the flow coefficient increases. The relative flow angle at the small clearance region decreases which result in a negative incidence angle at the high flow coefficient. It causes a recirculation region at the blade pressure surface which results in the flow blockage. It promotes the strength of the flow field redistribution at the rotor outlet. These flow pattern changes have an effect on the blade loading perturbations. The integration of blade loading perturbation from control volume analysis of the circumferential momentum leads to well-known Alford's force. Alford's force is always negative when the flow blockage effects are excluded. However when the flow blockage effect is incorporated into the modeling, main flow effects on the flow redistribution is also reflected on the Alford's force at the high flow coefficient. Alford's force steeply increases as the flow coefficient increases, because of the tip leakage suppression and strong flow redistribution. The predicted results are well agreed to CFD results by Kang and Kang(2006).

  • PDF