• 제목/요약/키워드: Local Heat Transfer Coefficient

검색결과 201건 처리시간 0.026초

An Analytic Study on Laminar Film Condensation along the Interior Surface of a Cave-Shaped Cavity of a Flat Plate Heat Pipe

  • Lee, Jin-Sung;Kim, Tae-Gyu;Park, Tae-Sang;Kim, Choong-Sik
    • Journal of Mechanical Science and Technology
    • /
    • 제16권7호
    • /
    • pp.966-974
    • /
    • 2002
  • An analytic approach has been employed to study condensate film thickness distribution inside cave-shaped cavity of a flat plate heat pipe. The results indicate that the condensate film thickness largely depends on mass flow rate and local velocity of condensate. The increasing rate of condensate film for circular region reveals about 50% higher value than that of vertical region. The physical properties of working fluid affect significantly the condensate film thickness, such as the condensate film thickness for the case of FC-40 are 5 times larger than that of water. In comparison with condensation on a vertical wall, the average heat transfer coefficient in the cave-shaped cavity presented 10∼15% lower values due to the fact that the average film thickness formed inside the cave-shaped cavity was larger than that of the vertical wall with an equivalent flow length. A correlation formula which is based on the condensate film analysis for the cave-shaped cavity to predict average heat transfer coefficient is presented. Also, the critical minimum fill charge ratio of working fluid based on condensate film analysis has been predicted, and the minimum fill charge ratios for FC-40 and water are about Ψ$\_$crit/=3∼7%, Ψ$\_$crit/=0.5∼1.3% respectively, in the range of heat flux q"=5∼90kW/㎡.

Experimental investigation of two-phase natural circulation loop as passive containment cooling system

  • Lim, Sun Taek;Kim, Koung Moon;Kim, Haeseong;Jerng, Dong-Wook;Ahn, Ho Seon
    • Nuclear Engineering and Technology
    • /
    • 제53권12호
    • /
    • pp.3918-3929
    • /
    • 2021
  • In this study, we experimentally investigate of a two-phase natural circulation loop that functions as a passive containment cooling system (PCCS). The experimental apparatus comprises two loops: a hot loop, for simulating containment under severe accidents, and a natural circulation loop, for simulating the PCCS. The experiment is conducted by controlling the pressure and inlet temperature of the hot loop in the range of 0.59-0.69 MPa (abs) and 119.6-158.8 ℃, respectively. The heat balance of the hot loop is established and compared with a natural circulation loop to assess the thermal reliability of the experimental apparatus, and an additional system is installed to measure the vapor mass flow rate. Furthermore, the thermal-hydraulic characteristics are considered in terms of a temperature, mass flow rate, heat transfer coefficient (HTC), etc. The flow rate of the natural circulation loop is induced primarily by flashing, and a distortion is observed in the local HTC because of the fully develop as well as subcooled boiling. As a result, we present the amount of heat capacity that the PCCS can passively remove according to the experimental conditions and compared the heat transfer performance using Chen's and Dittus-Boelter correlation.

비예혼합 역류화염에서 열전대 측정을 적용하기 위한 복사보정에 관한 연구 (A Study On the Radiation Corrections Applied to Thermocouple Measurements in Non-premixed Counterflow Flames)

  • 오율권;허준영;차경옥
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제26권2호
    • /
    • pp.209-218
    • /
    • 2002
  • The temperature field of a counterflow non-premixed flame is investigated using thermocouples of two sizes. A thermal balance is performed on the thermocouple in order to calculate the magnitude of the radiation corrections involved. Both the thermocouple wire and bead are separately considered to be the relevant thermal surface to which convective heat transfer takes place, and from which radiation lasses occur. The flame is also simulated by using a detailed chemical kinetic mechanism in a previously developed computer code. The local thermo-physical properties of the gas mixture, required to calculate the corrections, are determined both from the simulation, and by approximating the properties of the mixture as those of molecular nitrogen at the measured temperatures. It is concluded that the thermocouple wire is the appropriate thermal surface to which radiation corrections apply, in the absence of information about the gas mixture, its properties can be reasonably approximated by those of nitrogen rm ($N_2$), and the radiation corrections are very sensitive to misalignments in the temperature and velocity fields.

균일 열플럭스가 있는 $180^{\circ}C$ 원형단면 곡관의 선회유동 열전달특성 연구 (A study on the heat transfer characteristics of swirling flow in a circular sectioned $180^{\circ}C$bend with uniform heat flux)

  • 이상배;권기린;장태현
    • 대한기계학회논문집B
    • /
    • 제21권5호
    • /
    • pp.615-627
    • /
    • 1997
  • An experiment was performed to local heat transfer coefficient and Nusselt number in the circular duct of 180.deg. bend for Re=6*10$^{4}$, 8*10$^{4}$ and 1*10$^{5}$ at swirling flow and non-swirling flow conditions. The test tube with circular section was made by stainless which has curvature ratio 9.4. The wall of test tube was heated directly by electrical power to 3.51 kw and swirling motion of air was produced by a tangential inlet to the pipe axis at the 180 degree. Measurements of local wall temperatures and bulk mean temperature of air are made at four circumferential positions in the 16 stations. The wall temperatures show particularly reduced distribution curve at bend for non-swirling flow but this effect does not appear for swirling flow. Nusselt number distributions for swirling flow which was calculated from the measured wall and bulk temperatures were higher than that of non-swirling flow. Average Nusselt number of swirling flow increased about 90 ~ 100% than that of non-swirling flow whole through the test tube. The Nu/N $u_{DB}$ values at the station of 90.deg. for non-swirling flow and swirling flow are respectively about 2.5 and 4.8 at Re=6*10$^{4}$. Also that is good agreement with Said's result for non-swirling flow. flow.

EFFECTS OF SORET AND DUFOUR ON NATURAL CONVECTIVE FLUID FLOW PAST A VERTICAL PLATE EMBEDDED IN POROUS MEDIUM IN PRESENCE OF THERMAL RADIATION VIA FEM

  • RAJU, R. SRINIVASA
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제20권4호
    • /
    • pp.309-332
    • /
    • 2016
  • Finite element method has been applied to solve the fundamental governing equations of natural convective, electrically conducting, incompressible fluid flow past an infinite vertical plate surrounded by porous medium in presence of thermal radiation, viscous dissipation, Soret and Dufour effects. In this research work, the results of coupled partial differential equations are found numerically by applying finite element technique. The sway of significant parameters such as Soret number, Dufour number, Grashof number for heat and mass transfer, Magnetic field parameter, Thermal radiation parameter, Permeability parameter on velocity, temperature and concentration evaluations in the boundary layer region are examined in detail and the results are shown in graphically. Furthermore, the effect of these parameters on local skin friction coefficient, local Nusselt number and Sherwood numbers is also investigated. A very good agreement is noticed between the present results and previous published works in some limiting cases.

실린더 형상 변화가 실린더 주위 강제대류에 미치는 영향에 관한 수치적 연구 (A Numerical Study on the Effect of the Cylinder Shape Modification on the Forced Convection Around a Circular Cylinder)

  • 김민호;하만영;윤현식;이진욱
    • 설비공학논문집
    • /
    • 제23권10호
    • /
    • pp.670-677
    • /
    • 2011
  • Direct numerical simulation are performed in order to investigate the effect of the circular cylinder shape on the forced convection around a circular cylinder at the Reynolds number of 300 and Prandtl number of 0.71. Three-dimensional characteristics of fluid flow and heat transfer around the smooth, wavy and torsional cylinders are investigated. A wavy cylinder has the sinusoidal variation in the cross sectional area along the spanwise direction with the wave length of ${\pi}/3$ and wavy amplitude of 0.1. A torsional cylinder has the twisted elliptic cross section with a torsional period of ${\pi}/2$ and an axis ratio of 1.35 corresponding to the major axis of 1.15 and the minor axis of 0.85. The value of time-and surface-averaged drag coefficient for the smooth cylinder is similar to that for the wavy cylinder, but larger than that for the torsional cylinder. The time and surface-averaged lift coefficient for the smooth cylinder is larger than that for the wavy and torsional cylinders. The time-averaged local heat transfer rate for the wavy and torsional cylinders shows different distribution along the circumferential direction, compared to that for the smooth cylinder because of the shape change in the spanwise direction for the cases of the wavy and torsional cylinders.

합성 박스형 교량의 온도 예측 (The Prediction of Temperature in Composite Box Girder Bridges)

  • 장승필;임창균
    • 한국강구조학회 논문집
    • /
    • 제9권3호통권32호
    • /
    • pp.431-440
    • /
    • 1997
  • 본 논문에서는 교량 단면 내의 시간 종속적 온도 분포를 결정하기 위해, 기존의 열 전달 이론 및 태양 에너지 전달에 대한 이론을 바탕으로 기상관측소 및 현장에서 측정한 기상 자료로부터 교량 온도의 예측에 관한 이론적 모델에 대해 기술하였다. 특히 이 모텔에서는 주간에 교량의 온도 상승에 지배적인 영향을 미치는 태양일사(solar radiation)에 대해 태양 에너지 관련 분야의 여러 실험적 연구 결과를 바탕으로 태양일사량의 계산에 대해 기존에 연구되어 있는 식들 중에서 가장 적합한 식을 제시하였다. 이 해석 모델의 타당성은 사당 고가차도의 장기 계측된 온도 측정 결과와 비교 검토되었다. 또한 장기간 측정된 온도 결과로부터 교량 온도 예측에 대한 해석적 기준(analytical criteria)을 제시하기 위해, 교량의 축 방향 신축의 원인이 되는 단면평균온도, 그리고 곡률 변형을 유발하는 단면온도차 등 교량 단면의 온도 분포와 관련된 변수들과 대기온도, 일사량 등 기상 자료와 관련된 변수들 간의 선형 상관관계(linear correlation)에 대해 기술하였다.

  • PDF

Comparative analysis on darcy-forchheimer flow of 3-D MHD hybrid nanofluid (MoS2-Fe3O4/H2O) incorporating melting heat and mass transfer over a rotating disk with dufour and soret effects

  • A.M. Abd-Alla;Esraa N. Thabet;S.M.M.El-Kabeir;H. A. Hosham;Shimaa E. Waheed
    • Advances in nano research
    • /
    • 제16권4호
    • /
    • pp.325-340
    • /
    • 2024
  • There are several novel uses for dispersing many nanoparticles into a conventional fluid, including dynamic sealing, damping, heat dissipation, microfluidics, and more. Therefore, melting heat and mass transfer characteristics of a 3-D MHD Hybrid Nanofluid flow over a rotating disc with presenting dufour and soret effects are assessed numerically in this study. In this instance, we investigated both ferric sulfate and molybdenum disulfide as nanoparticles suspended within base fluid water. The governing partial differential equations are transformed into linked higher-order non-linear ordinary differential equations by the local similarity transformation. The collection of these deduced equations is then resolved using a Chebyshev spectral collocation-based algorithm built into the Mathematica software. To demonstrate how different instances of hybrid/ nanofluid are impacted by changes in temperature, velocity, and the distribution of nanoparticle concentration, examples of graphical and numerical data are given. For many values of the material parameters, the computational findings are shown. Simulations conducted for different physical parameters in the model show that adding hybrid nanoparticle to the fluid mixture increases heat transfer in comparison to simple nanofluids. It has been identified that hybrid nanoparticles, as opposed to single-type nanoparticles, need to be taken into consideration to create an effective thermal system. Furthermore, porosity lowers the velocities of simple and hybrid nanofluids in both cases. Additionally, results show that the drag force from skin friction causes the nanoparticle fluid to travel more slowly than the hybrid nanoparticle fluid. The findings also demonstrate that suction factors like magnetic and porosity parameters, as well as nanoparticles, raise the skin friction coefficient. Furthermore, It indicates that the outcomes from different flow scenarios correlate and are in strong agreement with the findings from the published literature. Bar chart depictions are altered by changes in flow rates. Moreover, the results confirm doctors' views to prescribe hybrid nanoparticle and particle nanoparticle contents for achalasia patients and also those who suffer from esophageal stricture and tumors. The results of this study can also be applied to the energy generated by the melting disc surface, which has a variety of industrial uses. These include, but are not limited to, the preparation of semiconductor materials, the solidification of magma, the melting of permafrost, and the refreezing of frozen land.

GaN 에피층 성장을 위한 MOCVD 반응로의 가스 유동에 관한 수치해석 (Numerical Analysis on the Gas Flows in MOCVD Reactor for the Growth of GaN Epitaxy)

  • 신창용;백병준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.770-775
    • /
    • 2001
  • Numerical calculation has been performed to investigate the fluid flow, heat transfer and local mass fraction of chemical species in the MOCVD (metalorganic chemical vapor deposition) manufacturing process. The mixing of reactants (trimethylgallium with hydrogen gas and ammonia) was presented by the concentration of each reactants to predict the uniformity of film growth. Effects of inlet size, location, mass flow rate and susceptor/cold wall tilt angle on the concentration were reported. The newly developed reactor, that precursors were supplied at separated inlet to prevent from premixing, was investigated to obtain the quantitative verification. As a results, the optimum mass flow rate, wall tilt angle and inlet conditions were proposed.

  • PDF

수평 및 수직형 CVD 증착로의 실리콘 부착에 관한 수치해석 (Numerical Analysis of Silicon Deposition in Horizontal & Vertical CVD Reactor)

  • 김인;백병준
    • 대한기계학회논문집B
    • /
    • 제26권3호
    • /
    • pp.410-416
    • /
    • 2002
  • The fluid flow, heat transfer and the local mass fraction of chemical species in the chemical vapor deposition(CVD) manufacturing process are studied numerically. Flow with a dilute precursor concentration of silane in hydrogen as the carrier gas enters to the reactor and deposits silicon onto the heated surface. The silicon deposition rate using silane is calculated in the horizontal or vertical, axisymmetric reactor. The effects of inlet carrier gas velocity, mass fraction of silane, susceptor angle and rotation of surface on the deposition rate are described.