• Title/Summary/Keyword: Load-Settlement

Search Result 590, Processing Time 0.028 seconds

Consolidation Characteristics of Chungju Dam Deposit Soil in the Load Increment Ratio (하중증가비에 따른 충주댐 퇴적지반의 압밀 특성)

  • 이준대;오세욱
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.4
    • /
    • pp.123-126
    • /
    • 2000
  • This study shows consolidation properties resulted from the experiment made on changes by load increment ratio and consolidation duration of standard consolidation test using deposit soil of Chungju Dam. Though the comparison and analysis of the result turned out that void ratio by load increment ratio was unchanged greatly, the result was inclined as followes : the smaller load increment ratio is, the bigger void ratio is, while the bigger load increment ratio is the bigger settlement is. Also coefficient of consolidation is increased in inverse ratio to load increment ratio. Coefficient of permeability is increased in proportion to load increment ratio, it is not fixed changes by consolidation duration, however. Degree of consolidation is increased to load increment ratio.

  • PDF

Analysis of Pile Behaviors with Friction Resistance of Skin of Steel Pipe Pile in Ground where Settlement is Predicted (침하가 예측되는 지반에서 강관말뚝 주면 마찰 저항에 따른 말뚝의 거동 분석)

  • Lee, Kicheol;Shin, Sehee;Lee, Haklin;Kim, Dongwook
    • Journal of the Korean Geotechnical Society
    • /
    • v.36 no.11
    • /
    • pp.107-117
    • /
    • 2020
  • Open-ended steel pipe piles have outside frictional force and inside frictional resistance in which blocked soil acts on the inside of the steel pipe during installation. It is expected that the ultimate load will change depending on the inside and outside resistance. And, if the ground on which the piles were constructed is clay soil, it is predicted that it will have effect on the negative skin friction caused by the ground settlement. Therefore, in this study, the behavior according to the inside and outside resistance characteristics of steel pipe piles was analyzed numerically, and the frictional force distribution, axial load and settlements before and after the occurrence of ground settlement were calculated. As a result of the analysis, the inside frictional resistance had less influence than the outside frictional resistance. However, inside frictional resistance is considered to be one of the important factors considering the effect on the overall pile behavior, and both resistance factors need to be considered in the design process.

Analysis of Abnormal Settlement Aspect of Caisson Breakwater by Incoming Wave Action in Affected Area of Typhoon (태풍영향권 내습파랑에 의한 직립방파제 이상침하 현상분석)

  • Lee, Joong-Koo;Kim, Hyo-Seob;Park, Koo-Yong;Ahn, Ik-Seong
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.21 no.6
    • /
    • pp.508-517
    • /
    • 2009
  • The real time movement of the caisson was measured when it was open to the waves during breakwater construction. As a result of measurement, no more settlement after the preloading in condition of designed loading was expected but sudden abnormal settlement took place through whole area of the breakwater when waves occurred by typhoon effect. To clarify the reason of this case, wave of the site has been reproduced and the equivalent wave pressure on the caisson was calculated. The numerical analysis of the effect of wave to the ground had been done. Site measurement data is in accordance with the result of numerical analysis.

Effectiveness of Reinforcement for Transitional Zone between Tunnel and Earthwork Using the Large Sleeper (대형침목을 이용한 터널/토공 접속구간의 보강효과)

  • Choi, Chan-Yong;Lee, Jin-Wook;Kim, Hun-Ki
    • Journal of the Korean Society for Railway
    • /
    • v.13 no.2
    • /
    • pp.214-221
    • /
    • 2010
  • The transitional zone between tunnel and earthwork is one of the most vulnerable areas site for railway lines and because of differential settlement due to different stiffness of each supporting layer, it has to conducted a maintenance work constantly. In this study, it is conducted to compare the effect of reinforcement by wheel load and displacement of the sleepers after existing sleepers are replaced with the large sleepers for 20m long in-field transitional zone. Also, numerical parametric study using multi-layer elastic method has been performed to compare rail force, settlement and stresses of ballast while varying size and space of the sleeper. The field test and numerical results show that replacing the large sleepers improves about 10% of total settlement and coefficient of wheel force than conventional sleepers. Effectiveness of improvement is about 9.3%, 4%, 14.5% for rail seat force, settlement of sleepers and ballast pressure respectively with size of sleepers.

Pressure-settlement behavior of square and rectangular skirted footings resting on sand

  • Khatri, Vishwas Nandkishor;Debbarma, S.P.;Dutta, Rakesh Kumar;Mohanty, Bijayananda
    • Geomechanics and Engineering
    • /
    • v.12 no.4
    • /
    • pp.689-705
    • /
    • 2017
  • The present study deals with the Pressure-settlement behavior of square and rectangular skirted footing resting on sand and subjected to a vertical load through a laboratory experimental study. A series of load tests were conducted in the model test tank to evaluate the improvement in pressure-settlement behavior and bearing capacity of square and rectangular model footings with and without structural skirt. The footing of width 5 cm and 6 cm and length/width ratio of 1 and 2 was used. The relative density of sand was maintained at 30%, 50%, 70%, and 87% respectively. The depth of skirt was varied from 0.25 B to 1.0 B. All the tests were carried out using a strain controlled loading frame of 50 kN capacity. The strain rate for all test was kept 0.24 mm/min. The results of present study reveal that, the use of structural skirt improves the bearing capacity of footing significantly. The improvement in bearing capacity was observed almost linearly proportional to the depth of skirt. The improvement in bearing capacity of skirted footings over footing without skirt was observed in the range of 33.3% to 68.5%, 68.9% to 127% and 146.7% to 262% for a skirt depth of 0.25 B, 0.50 B and 1.0 B respectively. The skirted footings were found more effective for sand at relative density of 30% and 50% than at relative density of 70% and 87%. The bearing capacity was found to increase linearly with footing width for footings with and without skirts. This observation was found to be consistent for footings with different skirt depths and for relative density of sand i.e., 30%, 50%, 70%, and 87%. The obtained results from the study for footing with and without skirts were comparable with available solutions from literature.

Foundation Analysis and Design Using CPT Results : Settlement Estimation of Shallow Foundation (CPT 결과를 이용한 기초해석 및 설계 : 얕은 기초의 침하량 산정)

  • 이준환;박동규
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.8
    • /
    • pp.5-14
    • /
    • 2004
  • The settlement of foundations under working load conditions is an important design consideration. Well-designed foundations induce stress-strain states in the soil that are neither in the linear elastic range nor in the range usually associated with perfect plasticity. Thus, in order to accurately predict working settlements, analyses that are more realistic than simple elastic analyses are required. The settlements of footings in sand are often estimated based on the results of in-situ tests, particularly the standard penetration test (SPT) and the cone penetration test (CPT). In this paper, we analyze the load-settlement response of vertically loaded footings placed in sands using both the finite element method with a non-linear stress-strain model and the conventional elastic approach. Based on these analyses, we propose a procedure for the estimation of footing settlement in sands based on CPT results.

Three-dimensional Modeling Seismic Analysis of Circular Water Reservoirs considering Differential Settlement Effects (부동침하 영향을 고려한 원형 배수지 구조의 3차원 모델링 지진 해석)

  • Lee, Sang-Youl;Choi, Hyung Bae;Ahn, Kwang Sik;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.31 no.1
    • /
    • pp.43-53
    • /
    • 2021
  • Three-dimensional finite element analysis of 1,300 ton stainless water reservoirs was undertaken to consider differential settlement effects of the reservoir when subjected to earthquake loads. The earthquake load for large (>1,000 ton) water reservoirs are further determined using a specification established from the Korean Standards Association. The structural behavior of water reservoirs with differential settlements can be heavily dependent on seismic loading effects. Stress and displacement distributions are induced for various load combinations, including for with and without differential settlements. From numerical examples, the induced maximum displacements of the water reservoirs largely increase with differential settlements compared to those without differential settlements.

Three Dimensional Numerical Analysis of Piled Raft on Soft Clay (연약지반에 시공된 Piled Raft 기초의 3차원 거동 분석)

  • Lee, Jin-Hyung;Jeong, Sang-Seom
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.5
    • /
    • pp.63-75
    • /
    • 2007
  • Piled raft is known to be an unfavorable foundation type in soft clay because foundation is associated with both excessive settlement and bearing capacity failure problems. Despite these reasons, in recent decades, an increasing number of structures have been constructed over soft clay area, piled raft concepts arouse interest as the foundation of structures on soft clay area becomes popular. This study described 3 dimensional behavior of piled raft on soft clay based on a numerical study using 3D finite element method. A series of numerical analyses were performed for a various pile lengths and the pile configurations on the raft were subjected to vertical uniform or point loading. Based on the results of the parametric study, comparisons were made among the effect of loading type, various pile length and configurations, and the load-settlement behavior and load sharing characteristics of piled raft were also evaluated. From the results, the characteristic of piled raft on soft clay was examined.

A Study on the Characteristics of Bearing Capacity for SIP Piles in Domestic Areas (국내 SIP 말뚝의 지지력 특성에 관한 연구)

  • Lee, Song;Park, Jun-Hong;Park, Joong-Bai;Kim, Tae-Hwoon
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.4
    • /
    • pp.319-327
    • /
    • 2002
  • In this research, problems of recent design methods and their improvement for SIP(Soil-Cement Injected precast Pile) in domestic areas were studied by using the properties of load-settlement curves and bearing capacity from field loading tests. Elastic and plastic settlement for total settlement in each loading step of loading tests conducted in domestic areas has been shown to have a tendency. From this tendency and bearing capacity determined by loading tests, it could be ascertained that empirical chart could be an assistant tool in SIP design. It was shown that SIP design using N-value in domestic area with soil condition of granitic type resulted in very conservative hearing capacity. On the other hands, in soil with unfitted geological conditions, the design could be insecure. Also, we could ascertain that Meyerhof's bearing capacity using modified N-value on the tip part of pile was more applicable than recent design method where tip bearing capacity was 20NA$_p$ N-value limited to 50. These results showed that modified design method could be more economic than those in the past because it used pile's bearing capacity unto tolerable load of pile material.