• 제목/요약/키워드: Load transients

검색결과 73건 처리시간 0.028초

Electric Arc furnaces: Chaotic Load Models and Transient Analysis

  • Jang, Gil-Soo;Venkata, S.S.;Kwon, Sae-Hyuk
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.923-925
    • /
    • 1998
  • Electric arc furnaces (EAFs) are a main cause of voltage flicker due to the interaction of the high demand currents of the load with the supply system impedance. The stochastic models have described the physical phenomena of EAFs. An alternative approach is to include deterministic chaos in the characterization of the arc currents. In this paper, a chaotic approach to such modeling is described and justified. At the same time, a DLL (Dynamic Link Library) module, which is a FORTRAN interface with TACS (Transient Analysis of Control Systems), is developed to implement the chaotic load model in the Electromagnetic Transients Program (EMTP). The details of the module and the results of tests performed on the module to verify the model and to illustrate its capabilities are presented in this paper.

  • PDF

A Seamless Control Method for Supercapacitor to Compensate Pulse Load Transients in DC Microgrid

  • Dam, Duy-Hung;Lee, Hong-Hee
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.198-199
    • /
    • 2017
  • This paper proposed a new control method for supercapacitor (SC) to compensate the pulse load transient and enhance the power quality of dc microgrid. By coordinating the operation frequency, the supercapacitor is controlled to handle the surge current component while the low-frequency current component is dealt with by remaining sources in the system. Based on the state of charge and dc bus voltage level, the SC unit operation mode is automatically decided. Meanwhile, the dc bus voltage level indicates the power demand of the whole system; by regulating the dc bus voltage, the mismatch of power demand is covered by SC unit. The effectiveness of proposed method is verified by experiment prototype formed by two distributed generation and one supercapacitor unit.

  • PDF

Robust feedback-linearization control for axial power distribution in pressurized water reactors during load-following operation

  • Zaidabadi nejad, M.;Ansarifar, G.R.
    • Nuclear Engineering and Technology
    • /
    • 제50권1호
    • /
    • pp.97-106
    • /
    • 2018
  • Improved load-following capability is one of the most important technical tasks of a pressurized water reactor. Controlling the nuclear reactor core during load-following operation leads to some difficulties. These difficulties mainly arise from nuclear reactor core limitations in local power peaking: the core is subjected to sharp and large variation of local power density during transients. Axial offset (AO) is the parameter usually used to represent the core power peaking. One of the important local power peaking components in nuclear reactors is axial power peaking, which continuously changes. The main challenge of nuclear reactor control during load-following operation is to maintain the AO within acceptable limits, at a certain reference target value. This article proposes a new robust approach to AO control of pressurized water reactors during load-following operation. This method uses robust feedback-linearization control based on the multipoint kinetics reactor model (neutronic and thermal-hydraulic). In this model, the reactor core is divided into four nodes along the reactor axis. Simulation results show that this method improves the reactor load-following capability in the presence of parameter uncertainty and disturbances and can use optimum control rod groups to maneuver with variable overlapping.

A Systems Engineering Approach to Multi-Physics Load Follow Simulation of the Korean APR1400 Nuclear Power Plant

  • Mahmoud, Abd El Rahman;Diab, Aya
    • 시스템엔지니어링학술지
    • /
    • 제16권2호
    • /
    • pp.1-15
    • /
    • 2020
  • Nuclear power plants in South Korea are operated to cover the baseload demand. Hence they are operated at 100% rated power and do not deploy power tracking control except for startup, shutdown, or during transients. However, as the contribution of renewable energy in the energy mix increases, load follow operation may be needed to cover the imbalance between consumption and production due to the intermittent nature of electricity produced from the conversion of wind or solar energy. Load follow operation may be quite challenging since the operators need to control the axial power distribution and core reactivity while simultaneously conducting the power maneuvering. In this paper, a systems engineering approach for multi-physics load follow simulation of APR1400 is performed. RELAP5/SCDAPSIM/MOD3.4/3DKIN multi-physics package is selected to simulate the Korean Advanced Power Reactor, APR1400, under load follow operation to reflect the impact of feedback signals on the system safety parameters. Furthermore, the systems engineering approach is adopted to identify the requirements, functions, and physical architecture to provide a set of verification and validation activities that guide this project development by linking each requirement to a validation or verification test with predefined success criteria.

STATCOM의 전압안정도개선 및 역률 보상 특성분석 (Characteristic Analysis of Voltage Stability Improvement and Power Factor Correction by STATCOM)

  • 박지용;박덕희;한병문
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권12호
    • /
    • pp.1507-1513
    • /
    • 1999
  • This paper describes simulation and experimental results to analyze the dynamic characteristics of STATCOM, which is connected to the ac system for compensation the power factor and improving the voltage stability. The simulation and experimental results confirm that the scaled model for STATCOM can properly compesate the power factor of the load and regulate the bus voltage at the common connection point.

  • PDF

CMOS Inverter의 Substrate Current를 줄이는 Layout 설계 (New Layout Design Concept for Suppressing the Substrate Current in CMOS Inverter)

  • 박흥준;김충기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 전기.전자공학 학술대회 논문집(I)
    • /
    • pp.407-410
    • /
    • 1987
  • A layout design concept which suppress the substrate current generated during the switching transients of an CMOS inverter is presented. The amount of hot carriers and the peak value of substrate current can be reduced by changing the device geometry ratio of driver and load device of an CMOS inverter.

  • PDF

상대식 승강장에서 열차 운행에 의한 지하철 승강장 스크린 도어 풍압해석 (WIND PRESSURE TRANSIENTS ON PLATFORM SCREEN DOOR OF SIDE PLATFORMS IN A SUBWAY STAT10N CAUSED BY PASSING TRAINS)

  • 이명성;이상혁;허남건
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2007년도 춘계 학술대회논문집
    • /
    • pp.64-67
    • /
    • 2007
  • In the present study, the wind pressure transients on platform screen door in side platforms caused by passing trains have been investigated numerically. The transient compressible 3-D full Navier-Stokes solution is obtained with actual operational condition of subway train and the moving mesh technique is adopted considering the train movement. To achieve more accurate analysis, the entrance and exit tunnel of platform are included in a computational domain and detailed shape of train is also modeled Numerical analyses were conducted on five operational condition which are different velocity variation of subway train, existence of stationary train and passing each other trains. The results show that pressure load on platform screen door is maximized when the two trains are passing each other. It is also seen from the computational results that the maximum pressure variation was found to be satisfactory to various foreign standards.

  • PDF

상대식 승강장에서 열차 운행에 의한 지하철 승강장 스크린 도어 풍압해석 (WIND PRESSURE TRANSIENTS ON PLATFORM SCREEN DOOR OF SIDE PLATFORMS IN A SUBWAY STATION CAUSED BY PASSING TRAINS)

  • 이명성;이상혁;허남건
    • 한국전산유체공학회지
    • /
    • 제12권4호
    • /
    • pp.1-6
    • /
    • 2007
  • In the present study, the wind pressure transients on platform screen door in side platforms caused by passing trains have been investigated numerically. The transient compressible 3-D full Navier-Stokes solution is used with actual operational condition of subway train by adopting the moving mesh technique considering the train movement. To achieve more accurate analysis, the entrance and exit tunnel connecting the stations are included in a computational domain with modeling the detailed shape of the train. Numerical analyses are conducted on five operational conditions which include the variation of the train speed, case with or without the train stopped in the other track, and case for two trains passing each other inside the station. The results show that pressure load on platform screen door is maximized when the two trains are passing each other. It is also seen from the computational results that the maximum pressure variation for the cases considered in the present study is found to be satisfactory to various foreign standards.

Low Frequency Current Ripple Mitigation of Two Stage Three-Phase PEMFC Generation Systems

  • Deng, Huiwen;Li, Qi;Liu, Zhixiang;Li, Lun;Chen, Weirong
    • Journal of Power Electronics
    • /
    • 제16권6호
    • /
    • pp.2243-2257
    • /
    • 2016
  • This paper presents a two stage three-phase proton exchange membrane fuel cell (PEMFC) generation system. When the system is connected to a three-phase load, it is very sensitive to the characteristics and type of the load. Especially unbalanced three-phase loads, which result in a pulsating power that is twice the output frequency at the inverter output, and cause the dc-link to generate low frequency ripples. This penetrates to the fuel cell side through the front-end dc-dc converter, which makes the fuel cell work in an unsafe condition and degrades its lifespan. In this paper, the generation and propagation mechanism of low frequency ripple is analyzed and its impact on fuel cells is presented based on the PEMFC output characteristics model. Then a novel method to evaluate low frequency current ripple control capability is investigated. Moreover, a control scheme with bandpass filter inserted into the current feed-forward path, and ripple duty ratio compensation based on current mode control with notch filter is also proposed to achieve low frequency ripple suppression and dynamic characteristics improvement during load transients. Finally, different control methods are verified and compared by simulation and experimental results.

저압 AC회로의 MOV 적용방안 연구 (A Study on the Utilization of Metal Oxide Varistor for Low-Voltage AC Circuits)

  • 최효열;이원빈;강영석;이재복
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1822-1824
    • /
    • 1996
  • Damage and upset of control and communication equipment due to transient overvoltages which occur due primarily to internal switching surge and external lightning surge are an important problems in electromagnetic compatibility(EMC). In this paper, we analyzed operation characteristic of metal oxide varistor widely used low voltage AC line using the electromagnetic transients program(EMTP) and compare it with experimental results and also, we modeled combination generator producing $1.2/50{\mu}s$ open circuit voltage and $8/20{\mu}s$ short circuit current as a source which is critical in calculating operation characteristic. Simulation results showed that most of Transient energy consumes at MOV located in service entrance side than load side, and it showed similar to experimental results. Therefore, entrance side MOV should be selected more energy capacity than that of load side MOV.

  • PDF