• Title/Summary/Keyword: Load transfer function

Search Result 197, Processing Time 0.03 seconds

Robust Adaptive Control of Hydraulic Positioning System Considering Frequency Domain Performance (주파수역 성능을 고려한 유압 위치시스템의 강인 적응 제어)

  • Kim, Ki-Bum;Kim, In-Soo
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.2
    • /
    • pp.157-163
    • /
    • 2014
  • In this paper, a robust MRAC (model reference adaptive control) scheme is applied to control an electrohydraulic positioning system under various loads. The inverse dead-zone compensator in the control system cancels out the dead-zone response, and an integrator added to the controller provides good position-tracking ability. LQG/LTR (linear quadratic Gaussian control with loop transfer recovery) closed-loop model is used as the reference model for learning the MRAC system. LQG/LTR provides a systematic technique to design the linear controller that optimizes the objective function using some compromise between the control effort and the system performance in the frequency domain. Different external load tests are performed to investigate the effectiveness of the designed MRAC system in real time. The experimental results show that the tracking performance of the proposed system is highly accurate, which offers considerable robustness even with a large change in the load.

Output LC Filter Design of Voltage Source Inverter Considering the Performance of Controller (제어기응답을 고려한 전압형 인버터의 출력 LC필터 설계)

  • Kim, Jae-Sig;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1077-1079
    • /
    • 2000
  • In this paper. the design procedure of the inverter output filter is described. The transfer function of the filter output voltage to the load current is described with the capacitor value and the system time constant including the controller. This means that the relation between the filter capacitor value and the system time constant is given as the closed form. By using the above closed form. the capacitor value can be calculated with the system time constant which can be implemented practically not using the try and error method. And as the effect of the load current to the voltage distortion can be calculated from the closed form, it can be verified how much the voltage distortion is effected when the nonlinear load is connected.

  • PDF

Output LC Filter Design of Voltage Source Inverter Considering the Performance of Controller (제어기 성능을 고려한 전압형 인버터의 출력 LC필터 설계)

  • Min, Wan-Ki;Kim, Jae-Sig;Cho, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.10a
    • /
    • pp.206-211
    • /
    • 2005
  • The LC filter design procedure of the inverter output filter is described. The transfer function of the filter output voltage to the load current is described with the capacitor value and the system time constant considering the system controller. By using the closed form of the relation between the filter capacitor value and the system time constant, the capacitor value can be calculated with the given system time constant and vice versa. It is more practical for the implementation of power and control circuit of inverter. And as the effect of the load current to the voltage distortion can be calculated from the closed form, it is possible to analyze the system how much the voltage waveform is distorted in case of the nonlinear load. All the proposed design procedure is verified with the simulation and experimental results.

  • PDF

A Study on Modeling of FMS using Closed Queueing Network (폐쇄형 대기행렬 네트워크에 의한 FMS 모델링)

  • Jeong, Seok-Chan;Cho, Kyu-Kab
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.21 no.2
    • /
    • pp.153-165
    • /
    • 1995
  • Many closed queueing network models have been used as an effective tool to make a preliminary design of FMS. Although a loading/unloading function is an important factor to effect the utilization and throughput of FMS as well as a transfer function and a processing function, the Solberg's model did not clarify the loading/unloading function. In this paper, we propose a closed queueing network model for analyzing a flexible manufacturing system that consists of a load/unload station, a material handling system and a group of workstations for processing jobs, and define the expected utilization and the expected throughput of the FMS. As applications of the proposed model, the cases of a material handling system consisting of a conveyor and the FMS including an inspection station are also formulated.

  • PDF

Load compensation and Speed Controller for Hydraulic Inverter-fed Elevator (유압 인버터 엘리베이터를 위한 부하 보상 및 속도 제어기)

  • Han, Sang-Soo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.2
    • /
    • pp.163-167
    • /
    • 2014
  • To prove the vibration and speed error problems caused by the nonlinear friction characteristics and load variation of the hydraulic system, a PID speed controller and a load compensation controller for the hydraulic inverter-fed elevator are proposed. The load compensation controller is composed by the PI controller and the speed controller is composed by the PID controller. The P,I and D gains of the control parameters are obtained by the frequency response of system transfer function. The Effectiveness of the proposed controller are shown by experimental results, which the proposed controller yields robustness with load variations and stable and good speed and acceleration responses with less oscillations.

A Numerical Analysis of Convective Heat Transfer in Air Flow Channels of a Plate Fin-tube Matrix for Heat Pipe Heat Sinks (히트파이프 히트싱크에서 평판 휜-관으로 구성된 공기유동 냉각채널의 대류 열전달 특성에 관한 수치해석)

  • Kim Sung-Hoon;Shin Hyun-Myung;Kim Chul-Ju
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.8
    • /
    • pp.862-869
    • /
    • 2005
  • A study on convective cooling characteristics has been done in the channels with heat pipes and associated Plane fins Analysis with FLUENT V5.0 lies its Purpose on the possible enhancement of heat transfer capability between an existing three in-line arrayed heatpipes and an extending four in-line arrayed heatpipes with increasing channel width. Numerical analysis is limited to the laminar flow in an isolated flow channel by employing cyclic boundary conditions for calculation purposes. Friction factors for three and four in-line arrayed heatpipes are compared with experimental results. In addition, temperature behavior at the plate fin for the three in-line arrayed heatpipes is compared with experiment. Friction factors and overall channel heat transfer coefficients (and/or Nusselt numbers) are presented as a function of Reynolds number. An increase of number of heatpipes and channel width reults in a decrease of the friction factor and doesn't not result in an increase of heat transfer performance. However. considering the 25$\%$ increase of heat load accompanies with maximum 8$^{\circ}C$ rise of average temperature of heat pipes, the four in-line array with the increase of channel width of heat pipe heat sink can be considered appropriate.

A study on implementation of MAP-MMS protocol (MAP-MMS 프로토콜의 구현에 관한 연구)

  • 고우곤;강문식;박민용;이상배
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1989.10a
    • /
    • pp.520-523
    • /
    • 1989
  • MAP(Manufacturing Automation Protocol), Network Protocol for FA has 7 Layer Structure of OSI. Being an Application Layer Protocol for Communication Interfaced with the Actual Programmable Devices, MMS(Manufacturing Message Specification) Consists of Three Factors of Services, Interfaces, and Protocol. For Details, It Classifies with the Followings ; Connection/Context Management, Remote Variable Access, Semaphore Management, File transfer and Management, Program UP/DOWN Load, Remote Program Fxecution. In this Paper Designing MAP Network Station of Programmable Device, we Analyze the Protocol of MMS, and Realize the State Diagram of each Services and Propose the Model of MMS Function Call Instructions.

  • PDF

Numerical Analysis of Combustion Characteristics during Mode Transfer Period in a Lean Premixed Gas Turbine for Power Generation (발전용 희박예혼합 가스터빈에서 연소모드변환 시기의 연소특성 해석)

  • Chung Jae Hwa;Seo Seok Bin;Kim Jong Jin;Cha Dong Jin;Ahn Dal Hong
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.279-282
    • /
    • 2002
  • Recently, gas turbines for power generation adopt multistage DLN(Dry Low NOx) type combustion, where diffusion combustion is applied at low load and, with increase in load, the combustion mode is changed to lean premixed combustion to reduce NOx emissive concentration. However, during the mode changeover from diffusion to premixed flame, unfavorable phenomena, such as flashback, high amplitude combustion oscillations, or thermal damage of combustor parts could frequently occur. In the present study, to apply for the analysis of such unfavorable phenomena, three-dimensional CFD investigations are carried out to compare the detailed flow characteristics and temperature distribution inside the gas turbine combustor before and after combustion mode changeover. The fuel considered here is pure methane gas. A standard $k-{\varepsilon}$ turbulence model with wall function and a P-N type radiation heat transfer model, have been utilized. To analyze the complex geometric effects of combustor parts on combustion characteristics, fuel nozzles, a swirl vane f3r fuel-air mixing, and cooling air holes on the combustor liner wall, are included in this simulation.

  • PDF

Estimation of Group Walking Loads by System Identification of Building Structures (건축구조물의 시스템 식별을 통한 무리보행하중 평가)

  • 김태호;민경원;이동근
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.1
    • /
    • pp.65-72
    • /
    • 2003
  • The objective of this study is to estimate the frequency characteristics of group walking loads based on the information of measured responses. At first, dynamic properties such as natural frequencies and modes are obtained from input/output relation for building structures by heel drop test. Second, a method to estimate group walking loads by the transfer functions from measured responses to group walking loads is proposed. The method turned out to estimate the group walking loads accurately. Higher modes could be important in estimating the amplitude of group walking loads with the information of single walking load.

Real-Time Bus Reconfiguration Strategy for the Fault Restoration of Main Transformer Based on Pattern Recognition Method (자동화된 변전소의 주변압기 사고복구를 위한 패턴인식기법에 기반한 실시간 모선재구성 전략 개발)

  • Ko Yun-Seok
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.11
    • /
    • pp.596-603
    • /
    • 2004
  • This paper proposes an expert system based on the pattern recognition method which can enhance the accuracy and effectiveness of real-time bus reconfiguration strategy for the transfer of faulted load when a main transformer fault occurs in the automated substation. The minimum distance classification method is adopted as the pattern recognition method of expert system. The training pattern set is designed MTr by MTr to minimize the searching time for target load pattern which is similar to the real-time load pattern. But the control pattern set, which is required to determine the corresponding bus reconfiguration strategy to these trained load pattern set is designed as one table by considering the efficiency of knowledge base design because its size is small. The training load pattern generator based on load level and the training load pattern generator based on load profile are designed, which are can reduce the size of each training pattern set from max L/sup (m+f)/ to the size of effective level. Here, L is the number of load level, m and f are the number of main transformers and the number of feeders. The one reduces the number of trained load pattern by setting the sawmiller patterns to a same pattern, the other reduces by considering only load pattern while the given period. And control pattern generator based on exhaustive search method with breadth-limit is designed, which generates the corresponding bus reconfiguration strategy to these trained load pattern set. The inference engine of the expert system and the substation database and knowledge base is implemented in MFC function of Visual C++ Finally, the performance and effectiveness of the proposed expert system is verified by comparing the best-first search solution and pattern recognition solution based on diversity event simulations for typical distribution substation.