• Title/Summary/Keyword: Load shift

Search Result 274, Processing Time 0.023 seconds

Analysis and Design of Resonant Inverter for Reactive Gas Generator Considering Characteristics of Plasma Load

  • Ahn, Hyo Min;Sung, Won-Yong;Lee, Byoung Kuk
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.345-351
    • /
    • 2018
  • This paper analyzes a resonant inverter to generate plasma. The resonant inverter consists of a full bridge converter, resonant network and reactor to generate a magnetic field for plasma generation. A plasma load has very distinct characteristics compared to conventional loads. The characteristics of plasma load are analyzed through experimental results. This paper presents the study on the resonant network, which was performed in order to determine how to achieve a constant current gain. Another important contribution of this study is the analysis of drop-out phenomenon observed in plasma loads which is responsible for unpredictable shutdown of the plasma generator that requires stable operation. In addition, the design process for the resonant network of a plasma generator is proposed. The validity of this study is verified through simulations and experimental results.

Improved Direct Method for Calculating the Closest Voltage Collapse Point and Voltage Stability Enhancement by Generation Redispatch (최단 전압붕괴점 계산을 위한 개선된 직접법과 재급전에 의한 전압안정도 향상)

  • Nam, Hae-Kon;Song, Chung-Gi;Kim, Dong-Jun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.8
    • /
    • pp.958-964
    • /
    • 1999
  • The distance in load parameter space to the closest saddle node bifurcation (CSNB) point provides the worst case power margin to voltage instability and the left eigenvector at CSNB identifies the most effective direction to steer the system to maximize voltage stability under contingency. This paper presents an improved direct method for computing CSNB: the order of nonlinear systems equations is reduced to about twice of the size of load flow equations in contrast to about three-times in Dobson's direct method; the initial guess for the direct method is computed efficiently and robustly by combined use of continuation power flow, a pair of multiple load flow solution with Lagrange interpolation. It is also shown that voltage stability may be enhanced significantly with shift of generations in the direction of the left eigenvector at CSNB.

  • PDF

A Study of Demand Response Resource in Ancillary Service (계통보조서비스에서 부하자원의 활용방안에 대한 고찰)

  • Kim S.C.;Yoo S.Y.;Kim H.J.;Kim H.J.;Park J.B.;Sin J.R.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.663-665
    • /
    • 2004
  • There are some demand response program which is Direct Load Control and so on in Korea. These are used to manage lack of power stability or shift peak time for shading load. It is very important not only using stability power system but controling and scheduling power system on the whole. Interruptible loads are essential resources to solve lack of energy and limit of constructing generator On recently days, Demand Response Program's reliability is recognized as ancillary or reserve service in many country. This paper presents a necessity to apply demand resource to our ancillary program. For this reason, it is introduce overseas ancillary program using load resource.

  • PDF

Design of Modified Slip-Mode Frequency Shift Islanding Detection Method for Power Quality Improvement (Slip-Mode Frequency Shift 단독운전 검출 기법의 정상상태 전력 품질 개선)

  • Kim, Dong-Uk;Kim, Sungmin
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.539-547
    • /
    • 2018
  • Grid-connected inverter is required to cut off the power supplied to the grid at the islanding condition, immediately. For this reason, an islanding detection is an indispensable function for grid-connected distributed generation system. Slip-Mode frequency Shift (SMS) islanding detection method is very popular method to determine the grid state. SMS method supplies the reactive power to the load according to the grid frequency. In the islanding condition of grid, this injected reactive power pulls out the grid frequency from the allowable range, then the inverter system can detect the islanding condition of the grid. The SMS method can detect the islanding state well and does not generate any harmonics of the grid current. However, the reactive power would be generated and the power quality is reduced even though the grid is not islanding condition, but normal condition. In this paper, a modified SMS method is proposed to remove the reactive power in the normal condition. The performance of the proposed method is evaluated by 600W single phase inverter experimental results.

Nonlinear response of a resonant viscoelastic microbeam under an electrical actuation

  • Zamanian, M.;Khadem, S.E.;Mahmoodi, S.N.
    • Structural Engineering and Mechanics
    • /
    • v.35 no.4
    • /
    • pp.387-407
    • /
    • 2010
  • In this paper, using perturbation and Galerkin method, the response of a resonant viscoelastic microbeam to an electric actuation is obtained. The microbeam is under axial load and electrical load. It is assumed that midplane is stretched, when the beam is deflected. The equation of motion is derived using the Newton's second law. The viscoelastic model is taken to be the Kelvin-Voigt model. In the first section, the static deflection is obtained using the Galerkin method. Exact linear symmetric mode shape of a straight beam and its deflection function under constant transverse load are used as admissible functions. So, an analytical expression that describes the static deflection at all points is obtained. Comparing the result with previous research show that using deflection function as admissible function decreases the computation errors and previous calculations volume. In the second section, the response of a microbeam resonator system under primary and secondary resonance excitation has been obtained by analytical multiple scale perturbation method combined with the Galerkin method. It is shown, that a small amount of viscoelastic damping has an important effect and causes to decrease the maximum amplitude of response, and to shift the resonance frequency. Also, it shown, that an increase of the DC voltage, ratio of the air gap to the microbeam thickness, tensile axial load, would increase the effect of viscoelastic damping, and an increase of the compressive axial load would decrease the effect of viscoelastic damping.

Compensatory Change of a Dog with Glenoid Dysplasia in Kinetic Gait Analysis before and after Reconstruction of Medial Patellar Luxation (Case report) (관절오목 이형성이 있는 개의 내측 슬개골 탈구 수술 전, 후의 운동역학적 보상적 보행 변화 (증례보고))

  • Shinho Lee;Jeonghyun Seo;Yuri Cha
    • Journal of Korean Physical Therapy Science
    • /
    • v.31 no.1
    • /
    • pp.46-52
    • /
    • 2024
  • Background: This study aims to investigate compensatory strategy in a dog with glenoid dysplasia using kinetic gait analysis before and after reconstruction of medial patellar luxation. Design: Case report Method: On the platform, gait analysis was evaluated for a dog with congenital luxation and bilateral medial patellar luxation (MPL). A dog was evaluated for maximal vertical force (MVF), body load distribution (BLD), and symmetry index (SI), including the left forelimb with congenital luxation before MPL surgery, 15 days of surgery, and 40 days of surgery. Result:: In the comparison between the preoperative and the 15 days of surgery, the MVF of the bilateral forelimbs, especially in the non-affected forelimbs, increased, and the SI also increased. For BLD, the maximum load distribution increased, but the total load distribution decreased. In the comparison of 15 days and 40 days of surgery, MVF and BLD increased, and SI decreased on 40days of surgery. Conclusions: In a dog, the shift in weight load to the non-affected side occurs all the limbs, affecting the peak vertical force, weight load distribution, and symmetry index.

The Effects of Job Stress on Workers' Physiological Somatic Complaints (직무스트레스가 근로자들의 신체적 불편감에 미치는 영향)

  • Lee, Jong-Eun;Jung, Hye-Sun;Lee, Bok-Im;Kim, Soon-Lae
    • Research in Community and Public Health Nursing
    • /
    • v.15 no.2
    • /
    • pp.289-297
    • /
    • 2004
  • Purpose: This study was conducted to determine factors affecting workers' physiological somatic complain using the Job Stress Model proposed by the National Institute for Occupational Safety and Health (NIOSH). Method: Data were collected from the 1st to the 30th of December 1999. The subjects were 2.123 workers employed at 155 work sites. Collected date were analyzed through SAS/PC program. Result: According to individual characteristics, younger and women groups showed significantly higher physiological somatic complaint than elder men groups. By work condition, groups with higher physiological somatic complaint included workers of irregular shift work. Dark lighting, improper temperature in winter, improper ventilation, inappropriate humidity, unpleasant work environment and crowded work place were significantly related with physiological somatic complaint. By work-related factor, physiological somatic complaint was high in those with higher variance in work load, quantitative work load, role conflict, job burden, role ambiguity and future ambiguity. On the other hand, physiological somatic complaint was low in those with little underutilization of ability. As for the relationships between physiological somatic complaint and non-work related factors, physiological somatic complaint was high in workers who had a side job, were bringing up infants alone, cleaned the house alone, cared for the elderly and disabled persons, were studying, were volunteering at another organization, and were spending 5-10 hours in religious activities per week. Physiological somatic complain was in significantly negative correlations with overall social support, supervisory support and family support, but in significantly positive correlations with co-worker support. Conclusion: The main predictors of physiological somatic complain were gender, shift work pattern, overtime work, ventilation, role ambiguity, role conflict, future ambiguity, job control, variance in work load, overall social support, worker with side job, worker who cleans the house alone, worker who is studying. These predictors explained 19.10% of the total variance of physiological somatic complain.

  • PDF

Design and Implementation of Reactive Circuit for Ferroelectric Phase Shifter (강유전체 위상 변위기를 위한 Reactive Circuit 설계 및 구현)

  • Kim Young-Tae;Moon Seung-Eon;Lee Su-Jae;Kim Sun-Hyeong;Park Jun-Seok;Cho Hong-Goo
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2003.08a
    • /
    • pp.286-288
    • /
    • 2003
  • In this paper, in order to obtain a large differential phase shift with a little change in applied voltage, a ferroelectric reflective load circuit has been designed on top of barium strontium titanate $(Ba,Sr)TiO_3$ [BST] thin film. The design of the ferroelectric reflection-type phase shifter is based on a reflection theory of terminating circuit, which has a reflection-type analogue phase shifter with two ports terminated in symmetric phase-controllable reflective networks. To achieve large amounts of phase shift in low bias-voltage range, the effects of change of capacitance and transmission line connected with two coupled ports of a 3-dB $90^{\circ}$ branch-line hybrid coupler have been investigated. A large phase shift with a small capacitance change in the parallel terminating circuit has been demonstrated in the paper.

  • PDF

A 48V-400V Non-isolated Bidirectional Soft-switching DC-DC Converter for Residential ESS (PPS 제어기법을 적용한 48V-400V 비절연 양방향 DC-DC컨버터)

  • Jeong, Hyeon-Ju;Kwon, Min-Ho;Choi, Se-Wan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.3
    • /
    • pp.190-198
    • /
    • 2018
  • This paper proposes a nonisolated, bidirectional, soft-switching DC - DC converter with PWM plus phase shift (PPS) control. The proposed converter has an input-parallel/output-series configuration and can achieve the interleaving effect and high voltage gains, resulting in decreased voltage ratings in all related devices. The proposed converter can operate under zero-voltage switching (ZVS) conditions for all switches in continuous conduction mode. The power flow of the proposed converter can be controlled by changing the phase shift angle, and the duty is controlled to balance the voltage of four high voltage side capacitors. The PPS control device of the proposed converter is simple in structure and presents symmetrical switching patterns under a bidirectional power flow. The PPS control also ensures ZVS during charging and discharging at all loads and equalizes the voltage ratings of the output capacitors and switches. To verify the validity of the proposed converter, an experimental investigation of a 2 kW prototype is performed in both charging and discharging modes under different load conditions and a bidirectional power flow.

A Study on Implementation of Powerline Carrier Modem using 5-ary Frequency Shift Keying Method (5-ary 주파수 천이 키잉 방식을 이용한 전력선 캐리어 모뎀 구현에 관한 연구)

  • Park, Sung-Wook;Park, Jong-Wook
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.42 no.3
    • /
    • pp.39-44
    • /
    • 2005
  • In this paper, we use the 5-ary frequency shift keying method for robust powerline communication. To transmit the data by the 3-ary carrires among 5-ary carrirers and three carriers are 115kHz, 120kHz and 125kHz. Each time of three carrires is 0.33ms and total transmitting time duration from zero crossing point has 1ms. We use the dummy carriers which are 50kHz and 350kHz for monitoring the powerline channel state, dummy signal duration is received during 1ms. Experimentation result is shown that the implemented PLC transceiver has better than chirp transceiver at the capacitive load testing in spite of low transmission power.