• Title/Summary/Keyword: Load resistance

Search Result 2,423, Processing Time 0.037 seconds

Electrical Characteristics of Disk-type Piezotransformer with Electrode Ratio of Driving and Generating Part (디스크형 압전변압기의 전극비에 따른 전기적 특성)

  • Lee, J.P.;Chae, H.I.;Jeong, S.H.;Kang, H.S.;Lee, C.H.;Shin, H.T.;Hong, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1490-1492
    • /
    • 2003
  • A new type of piezoelectric transformer using radial vibration of disk, poled with the same direction is proposed. The piezoelectric ceramics was composed to PZT-PMN-PSN. The surface ratio of driving electrode and generating electrode of the piezoelectric transformer ranges from 1.4:1 to 3:1. As a experimental result, both resonance frequency and step-up voltage ratio increased with increasing load resistance. The step-up voltage ratio was reached more than 60 times under no load resistance. The maximum efficiency of 97.7% at load resistance of 2k${\Omega}$ was obtained.

  • PDF

Characteristics of Step-Down Transformer in PZT Piezoelectric Ceramics (PZT계 압전 세라믹 변압기의 감압특성)

  • 김오수;이준형;손정호;남효덕;조상희
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.11
    • /
    • pp.885-891
    • /
    • 2001
  • Ring/dot-type step-down piezoelectric transformer was manufactured by using Pb[(Mn$\sub$1/3/Sb$\sub$2/3)$\sub$0.05/Zr$\sub$0.475/Ti$\sub$0.475/]O$_3$ ceramics, which have excellent high-power piezoelectric properties. The characteristics of step-down piezoelectric transformer as a function of load resistance at output terminal was examined. Voltage gain was greatly dependent on drive frequency and load resistance, and showed maximum voltage gain at the resonance frequency. The output voltage was linearly increased as the input voltage increased. Voltage gain of the step-down piezoelectric transformer with respect to input voltage was very stable when the load resistance was in the range of 50-500 $\Omega$ .

  • PDF

Electrical Properties of High Power Step Down Multilayer Piezoelectric Transformer using Low Temperature Sintering PMN-PNN-PZT Ceramics (저온소결 PMN-PNN-PZT 세라믹스를 이용한 고출력 강압용 적층 압전변압기의 전기적 특성)

  • Yoo, Ju-Hyun;Kim, Kook-Jin;Paik, Dong-Soo;Yoon, Hyun-Sang
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.4
    • /
    • pp.332-336
    • /
    • 2007
  • In this study, multilayer piezoelectric transformer was manufactured using the PMN-PNN-PZT ceramic and then the electrical characteristics were investigated according to the variations of frequency and load resistance. The voltage step-up ratio of multilayer piezoelectric transformer showed the maximum value at the vicinity of 75 kHz and increased according to the increase of load resistance. When the output impedance coincided with the load resistance, the multilayer piezoelectric transformer showed the temperature rise of less than $20^{\circ}C$ at the output power of 20 W. As the results, the multilayer piezoelectric transformer manufactured at low co-firing temperature of $940^{\circ}C$ using PMN-PNN-PZT ceramics could be stably driven as the step-down transformers.

Reliability analysis of tunnels with consideration of the earthquakes extreme events

  • Azadi, Mohammad;Ghasemi, S. Hooman;Mohammadi, Mohammadreza
    • Geomechanics and Engineering
    • /
    • v.22 no.5
    • /
    • pp.433-439
    • /
    • 2020
  • Tunnels are one of the most important constructions in civil engineering. The damage to these structures caused enormous costs. Therefore, the safe and economic design of these structures has long been considered. However, both applied loads on the tunnels as well as the resistance of the structural members are naturally uncertain parameters, hence, the design of these structures requires considering the probabilistic approaches. This study aims to determine the load and resistant factors of lining tunnels concerning the earthquake extreme events limit state function. For this purpose, tunnels that have been designed according to the previous design codes (AASHTO Tunnel LRFD 2017) and using reliability analysis, the optimum reliability of these structures for different loading scenarios is determined. In this paper, the tunnel is considered circular. Finally, the proper load and resistance factors are calculated corresponding to the obtained target reliability. Based on the performed calibration earthquake extreme events limit state function, the result of this study can be recommended to AASHTO Tunnel LRFD 2017.

Analysis of CWR Track Considering Wheel Loads (열차하중을 고려한 장대레일 궤도 해석)

  • Han, Sang-Yun;Kang, Young-Jong;Han, Teak-Hee;Lim, Nam-Hyoung;Kim, Jung-Hun
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2487-2492
    • /
    • 2011
  • At high rail temperature above the neutral temperature, high compressive axial stresses will occur in the rails. High thermal axial force and vehicle loads cause the track to shift in a lateral direction and the formation of track geometry imperfections (track irregularity). When the thermal stress level and track irregularity with vehicle load reach a critical value, the track loses stability. In many studies, the stability of CWR tracks is analyzed. However these studies are only considered in temperature load. The main objective of this investigation was to estimate a new, comprehensive, realistic, the stability of CWR tracks considering wheel load. The ballast resistance is changed by wheel load. When the wheel load is applied, rails and ties are moved upward or downward. In this case the friction between ties and ballasts is decreased or increased. In this study the change of the ballast resistance of each tie was applied to the nonlinear analysis of CWR tracks.

  • PDF

Permissible Criteria of the Stiffness of Lightweight Wall by the Horizontal Static Load (정적 수평하중에 의한 경량벽체의 최대변형량 허용기준에 관한 연구)

  • Song, Jung-Hyeon;Kim, Ki-Jun;Choi, Soo-Kyung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.204-205
    • /
    • 2014
  • Among common test methods of assessing structure safety for existing lightweight walls, the criteria of the quality assessment of the horizontal static load resistance has been considered ambiguous. In the current study, therefore, an experiment was conducted to figure out the standardized assessment criteria of the lightweight wall's horizontal static load resistance. Based on the findings of the experiment with gypsum board and ALC block walls, an acceptable amount of each standard and the variables of the stud wall arising from the appropriate load (1000N) on the wall in a daily life were accounted for, arbitrarily setting the maximum deformation amount below 15mm.

  • PDF

DESIGN OF ADAPTIVE CONTROLLER OF DC SERVO MOTOR (직류전동기의 적응 제어기 설계에 관한 연구)

  • Chang, S.G.;Won, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 1987.11a
    • /
    • pp.25-28
    • /
    • 1987
  • Design procedure of adaptive controller with variable load condition is present and applied to velocity control of small, permanent magnet DC servo motor. The state feedback control scheme is adopted and Recursive Least Squares algorithm is used for parameter estimation. In order to reduce the time consuming. In the procedure of adaptation-gain tuning of state feedback controller, approximate curve fitting technique is applied to the relations between load condition and poles of the system, load condition and feedback gains. With this method, fast adaptation can be accomplished. It is shown that this procedure can be applied not only to variable load condition but also to variation of other system constants, for example variation of resistance and inductance etc.. Simulation results is present for both cases - variable inertia load, variable motor resistance to verify performance improvements. This design procedure produces an adaptive con troller which is feasible for implementation with microprocessor by reducing calculation time.

  • PDF

A Numerical Analysis of Soil-Pile Systems for Pile Load Tests at a Korean Site (국내 말뚝재하시험에 대한 지반-말뚝계의 수치해석)

  • Oh, Se-Boong;Ahn, Tae-Kyong;Choi, Yong-Kyu
    • Journal of Ocean Engineering and Technology
    • /
    • v.13 no.1 s.31
    • /
    • pp.94-104
    • /
    • 1999
  • In order to evaluate the performance of axially of laterally loaded piles experimentaly, pile load tests can be carried out at the site Otherwise stress analyses or subgrade reaction analyses can solve the problem. In this study, stress analysis using FLAC code and subgrade reaction analyses using load transfer curves recommended by API(1993) were performed consistently on the basis of a result of site investigations, and the result of analyses was compared with the measured. As a result the behavior of pile heads was analyzed accurately for both axially and laterally loaded tests. Furthermore axially transferred loads were calculated appropriately for the measured and axial loads were transferred mainly mainly by the frictional resistance rather than by the tip resistance. Consequently, it can be commented that both analysis methods of soil-pile systems are applicable at teh objective site and that solutions may be more accurate if material properties from the site investigation are more explicit.

  • PDF

Numerical Investigations of the Experimental Techniques for Measuring the Acoustical Source Parameters of a Simplified Exhaust System (엔진 흡배기 소음원 특성의 특정법에 대한 수치적 연구)

  • 이정권;장승호
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.866-870
    • /
    • 2001
  • Measurement techniques for in-duct acoustic source parameters can be classified into the direct method and the load method, according to whether it utilizes an extra external source or not. It is reported that the load methods yield the negative source resistance and the purpose of this paper is to clarify that the time-varying nature of the source is the main cause of this physically implausible result. For this purpose, the direct and load methods for measuring the source characteristics of a simplified fluid machine are simulated using the time domain numerical analysis. In the numerical simulations, the method of characteristics is employed and the source characteristics are calculated from the resultant data. It is shown that the load method results in negative source resistance for some frequencies, whereas the direct method yields positive values for all frequencies considered. It is found that the result of load method is quite sensitive to the change of cylinder pressure or valve profile in contrast to the direct method.

  • PDF

The Elementary School Teachers' Understandings about the Characteristics of Currents according to the Connection Methods of Batteries in Simple Electric Circuits (전지의 연결방법에 따른 전류의 특성에 대한 초등교사들의 이해도)

  • Hyun, Dong-Geul;Shin, Ae-Kyung
    • Journal of Korean Elementary Science Education
    • /
    • v.33 no.2
    • /
    • pp.335-351
    • /
    • 2014
  • The 96 elementary school teachers' the degrees of understandings about the characteristics of the currents according to the connection methods of batteries in simple electric circuits were investigated. In this study, the concepts on the characteristics of currents according to the connection methods of batteries were divided 'the learned concepts' and 'the differentiated concepts'. The characteristics of the currents in the region of the larger resistance of load than the internal resistance of a battery were called the learned concepts, they are taught in the science curriculum. While the characteristics of the currents in the region of the smaller resistance of load than the internal resistance of a battery were called the differentiated concepts, they are not exposed clearly in the science curriculum. The results obtained in this study are as follows: The average score related to the learned concepts was relatively high, while the degree of the teachers' cognitions of the internal resistance of a battery and the resistance of wires were low. Also the average score related to the differentiated concepts was very low because it seems so new to the elementary school teachers. It strongly suggests that the elementary school teachers did not understand meaningfully the characteristics of the currents related to the connections of batteries on the ground of the cognitions of the internal resistances of batteries and the resistances of loads in simple electric circuits. Hence, they might experience difficulties due to the problems occurred in relation to the connections of batteries in the elementary school science lessons.