• 제목/요약/키워드: Load reduction characteristics

검색결과 475건 처리시간 0.029초

Laser Texturing한 평행 스러스트 베어링의 윤활특성 : 제4보 - 딤플 형상의 영향 (Lubrication Characteristics of Laser Textured Parallel Thrust Bearing : Part 4 - Effect of Dimple Shape)

  • 박태조
    • Tribology and Lubricants
    • /
    • 제27권6호
    • /
    • pp.338-343
    • /
    • 2011
  • Laser surface texturing (LST) methods are widely applied now to reduce friction and improve reliability of machine components such as thrust bearings, mechanical face seals and piston rings, etc. In this paper, the effect of dimple shapes on the lubrication characteristics of parallel thrust bearing are studied using a commercial computational fluid dynamics (CFD) code, FLUENT. Pressure and streamline distributions, variations of supporting load, leakage flow rate and friction force, are compared for three different dimple sectional shapes such as circle, pyramid and rectangle type. The lubrication characteristics are highly affected by dimple shapes and number of dimples. The pyramid type dimple shape can support the highest load while the rectangle type is the best in friction reduction.

A study on the average wind load characteristics and wind-induced responses of a super-large straight-cone steel cooling tower

  • Ke, S.T.;Du, L.Y.;Ge, Y.J.;Zhao, L.;Tamura, Y.
    • Wind and Structures
    • /
    • 제25권5호
    • /
    • pp.433-457
    • /
    • 2017
  • As a novel typical wind-sensitive structure, the wind load and wind-induced structural behaviors of super-large straight-cone cooling towers are in an urgent need to be addressed and studied. A super large straight-cone steel cooling tower (189 m high, the highest in Asia) that is under construction in Shanxi Power Plant in China was taken as an example, for which four finite element models corresponding to four structural types: the main drum; main drum + stiffening rings; main drum + stiffening rings + auxiliary rings (auxiliary rings are hinged with the main drum and the ground respectively); and main drum + stiffening rings + auxiliary rings (auxiliary rings are fixed onto the main drum and the ground respectively), were established to compare and analyze the dynamic properties and force transferring paths of different models. After that, CFD method was used to conduct numerical simulation of flow field and mean wind load around the cooling tower. Through field measurements and wind tunnel tests at home and abroad, the reliability of using CFD method for numerical simulation was confirmed. On the basis of this, the surface flow and trail characteristics of the tower at different heights were derived and the wind pressure distribution curves for the internal and external surfaces at different heights of the tower were studied. Finally, based on the calculation results of wind-induced responses of the four models, the effects of stiffening rings, auxiliary rings, and different connecting modes on the dynamic properties and wind-induced responses of the tower structure were derived and analyzed; meanwhile, the effect mechanism of internal suction on such kind of cooling tower was discussed. The study results could provide references to the structure selection and wind resistance design of such type of steel cooling towers.

와이어 로프의 파단특성에 관한 실험적 연구 (An Experimental Study on the Fracture Characteristics of Wire Ropes)

  • 김종현;이근오;태순호
    • 한국안전학회지
    • /
    • 제9권4호
    • /
    • pp.3-10
    • /
    • 1994
  • This study examines fracture characteristics of wire rope of 6$\times$37+FC 14mm B degree, Which has been widely used for the strength support for machinery, cranes and shipping. The examination Is based on the fellowing experimental conditions. Firstly, this study analyzes the effect of the strength of wlre rope. When number of broken wires is occuring at the level of 5%, 10% and 15% degree respectively in the following two cases:1) Case of broken down to each strand equally. 2) Case of broken down to one strand only. Secondly, this study analyzes the effect of corrosion on the strength of wire rope. Corrosion times are 72hours, 144hours and 216hours corrosion respectively under following conditions. 1) Case of only a corrosion without wire breaking. 2) Case of corrosion after 5% degree wire breaking to each strand equally. Some outcomes of these experiment are as follows. 1) From the of tension test, We can find that the ratio of strength reduction case of wire broke down to one strand concentrically is greater than that ratio case of broke down to each strand equally. 2) From the corrosion test, We can also find that the ratio of strength reduction case of corroded after 5% degree wire breaking to each strand equally Is greater than that ratio case of corroded without wire breaking. 3) After comparing theoretical fracture load of wires with experimental fracture load of wires, we can find the fracture load of the case of broken down to each strand equally is most similar to theoretical fracture load. 4) It is proposed that safety rules on wire rope in the Industrial safety and healthy labor of law have to change “breaking over 10% of number of wires in one strand of wire rope(excluded filler wire )”has to be replaced by“breaking over 10% of number of all wires in all strand of wire rope(excluded filler wire)”

  • PDF

가솔린 기관의 에탄올혼합연료의 배출가스 특성에 관한 연구 (Emission Characteristics of a Gasoline Engine Using Ethanol Blended Fuel)

  • 조행묵;정동화
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권3호
    • /
    • pp.516-521
    • /
    • 2004
  • In this paper, the effects of ethanol blended gasoline on emissions and their catalytic conversion efficiencies characteristics were investigated in gasoline engine with an electronic fuel injection. The results showed that the increase of ethanol concentration in the blended fuels brought the reduction of THC and $CO_2$ emissions from the gasoline engine. THC emissions were drastically reduced up to thirty percent. And brake specific fuel consumption was increased. but brake specific energy consumption was similar level. However. unburned ethanol and acetaldehyde emissions increased. The conversion efficiency of Pt/Rh based three-way catalysts and the effect of ethanol on CO and NOx emissions were investigated by the change of engine speed. load and air/fuel ratio. Furthermore, the ethanol blended fuel results in the reduction effect of THC. CO and NOx emissions at idle speed.

알루미늄 압출재의 압괴 및 굽힘붕괴 특성규명을 위한 시험 및 해석 (Test and Analysis for Axial and Bending Collapse Characteristics Evaluation of Aluminum Extruded Beams)

  • 김범진;허승진;구정서;송달호
    • 한국철도학회논문집
    • /
    • 제4권3호
    • /
    • pp.110-115
    • /
    • 2001
  • Recently, many engineers actively participate in research and development w.r.t the weight reduction and the safety increase of vehicle body structure to meet the requirement of fuel economy and regulations. However, vehicle design concept related with weight reduction and safety increase is reduced to the design conflict problem. In the paper, the axial and bending collapse test of aluminum extruded beams are performed and the collapse characteristics are investigated. The analysis method to verify the fracture characteristics of aluminum extruded beam is presented and discussed.

  • PDF

표면조직 가공한 유압부품면에서의 윤활특성 (Lubrication Characteristics of Surface Textured Hydraulic Machine Components)

  • 이준오;박태조
    • 드라이브 ㆍ 컨트롤
    • /
    • 제9권4호
    • /
    • pp.26-31
    • /
    • 2012
  • Friction reduction between sliding hydraulic machine components is required to improve efficiency and reliability of hydraulic machineries. It is recently reported that surface texturing on sliding bearing surfaces can reduce the friction force highly. In this paper, numerical analysis is carried out to investigate the effect of dimple numbers and inlet boundary pressures on the lubrication characteristics of a parallel sliding bearing using a commercial computational fluid dynamics (CFD) code, FLUENT. The results show that the pressure distribution, load capacity, dimensionless friction force and leakage with dimple number and their locations, and inlet pressures. The overall lubrication characteristics are highly affected by dimple numbers and boundary pressure. The numerical method adopted and results can be used in design of efficient hydraulic machine components.

냉각재 온도 감소 장식에 의한 원자력발전소 부하 추종 운전 해석 (Analysis of Nuclear Power Plant Load Follow Operation by Temperature Reduction Method)

  • Park, Sang-Yoon;Park, Goon-Cherl;Lee, Un-Cherl;Kang, Chang-Sun;Kim, Chang-Hyo;Chung, Chang-Hyun
    • Nuclear Engineering and Technology
    • /
    • 제18권3호
    • /
    • pp.209-217
    • /
    • 1986
  • 보론 희석이 불충분한 주기 말에서 부하추종 운전영역을 확장시키기 위해 냉 각재 입구 온도 감소 방식을 사용하였으며, 이 방식을 모사하고 부하추종 운전시 가압경수로 노심의 핵적 특성을 해석하기 위해 3차원적 전산체제를 확립하였다. 해석은 고리 1호기 1주기말에서 12-3-6-3부하추종 운전에 대해 MINB 및 SPINR 모드로 수행되었으며, 부가적으로 이 두 방식에 대한 출력복귀능력도 RETRAN02 코드를 사용한 계통해석과 더불어 시험하였다. 계산결과 냉각재 입구 온도를 감소시킴으로써 부하 추종운전이 주기 말에서도 가능함이 입증되었으며 14$^{\circ}$F의 입구 온도 감소에 따라, SRC가 제어봉만 사용하는 방식보다 MINB 모드에서는 13%, SPINR모드에서는 14%까지 증가됨을 보여주었다.

  • PDF

확률적 기법을 통한 직접부하제어의 제어지원금 산정 (Determination of Incentive Level of Direct Load Control using Probabilistic Technique with Variance Reduction Technique)

  • 정윤원;박종배;신중린
    • 에너지공학
    • /
    • 제14권1호
    • /
    • pp.46-53
    • /
    • 2005
  • 본 논문은 확률적 기법을 적용하여 직접부하제어의 적정한 지원금을 산정하는 새로운 방법론을 제안한다. 직접부하제어의 경제성 분석은 발전기의 고장정지 특성, 직접부하제어 자원의 차단용량 및 차단시간 등을 모두 고려해야 하기 때문에 현실적으로 불가능한 것으로 인식되었다. 따라서 기존의 연구에서는 시나리오 접근법을 사용하여 직접부하제어의 경제성 평가를 수행하였다. 본 논문에서는 몬테카를로 시뮬레이션을 적용하여 직접부하제어의 제어전력량을 확률적으로 추정하고 이를 기반으로 직접부하제어의 지원금을 산정하는 새로운 접근법을 개발하였다. 또한 시뮬레이션의 효율을 향상시키기 위하여 분산감소 기법을 적용하였다. 본 논문에서 제안한 방법론의 유용성을 보이기 위해 IEEE 24-모선 신뢰도 계통에 적용하여 사례연구를 수행하였다.

익산 밭경지 특성을 고려한 초생대 유출 및 유사 저감효과 모의 (Simulations of Reduction Effects on Runoff and Sediment for VFS Applications by Considering Uplands Characteristics in Iksan)

  • 이슬기;장정렬;최경숙
    • 한국농공학회논문집
    • /
    • 제56권5호
    • /
    • pp.89-99
    • /
    • 2014
  • The goal of this study was to evaluate sediment reduction effects of VFS (vegetative filter strip) applied for Iksan area in Saemangeum watershed. This study simulated runoff and sediment load from different types of uplands using VFSMOD-W. The general upland characteristics of the study area was investigated to build reasonable scenarios of the simulation. The simulation scenarios were designed by various areas, shapes, and slopes of uplands. Grass mixture was selected as VFS vegetation and the size of VFS was fixed as 10 % of uplands area. Additionally 50mm, 100mm, 150mm of daily rainfall were applied for the runoff and sediment simulation. As results, the calculated runoff and sediment loads were obtained $20.7{\sim}1,030.6m^3$ and 568.4~675,731.4 kg for the range of 0.1~1.0 ha of uplands with 7 % and 15 % slopes. The reduction effects on runoff and sediment were obtained 5~10 % and 21.0~47.7 % respectively from VFS applications. The VFSMOD-W simulations showed that runoff tended to increase as upland area and amount of rainfall increased while sediment increased when slope, length and area of uplands and amount of rainfall increased. These results indicated that rainfall amount and upland size are the critical factors for the generation of runoff and sediment load. In order to support this conclusion, further studies such as, long term monitoring, field experiments, and to calibrate and evaluate the model are necessary.

WQV 기반 비점오염저감시설의 강우유출수 처리비 경험공식의 개선 (The Improvement on the Empirical Formula of Stormwater Captured Ratio for Water Quality Volume Based Non-Point Pollutants Water Quality Control Basins)

  • 최대규;박무종;박배경;김상단
    • 한국물환경학회지
    • /
    • 제30권1호
    • /
    • pp.87-94
    • /
    • 2014
  • According to the technical guideline of water pollutant load management, the rainfall captured ratio which can be estimated by the empirical formula is an important element to estimate reduction loads of non-point pollutants water quality control basin. In this study, the rainfall captured ratio is altered to stormwater captured ratio considering its meaning in the technical guideline of water pollutant load management, and the new empircal formula of stormwater captured ratio is suggested. In order to do this, we calculate stormwater captured ratio by using the hourly rainfall data of seven urban weather stations (Busan, Daegu, Daejeon, Gangreung, Seoul, Gwangju, and Jeju) for 43 years. The regression coefficients of the existed empirical formula cannot reflect the catchment properties at all, because they are fixed values regardless of regions. However the empirical formula of stormwater captured ratio has flexible regression coefficients by runoff coefficient(C), so it is allowed to consider the characteristics of runoff in catchment. It is expected that reduction loads of storage based water quality control basin can be more reasonably estimated than before.