• Title/Summary/Keyword: Load flow calculation

Search Result 156, Processing Time 0.036 seconds

A Fast Sensitivity Matrix Update Technique for Accurate Contingency Analysis State Computation Technique in Power Systems (정확한 상정사고 분석을 위한 민감도 행렬의 신속한 Update 기법에 관한 연구)

  • Lee, Seung-Chul;Kim, Kyoung-Shin;Kwon, Byong-Gook
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.327-329
    • /
    • 2001
  • This paper presents a fast and accurate contingency analysis in EHV systems for line outages, loss of generation of redispatching and loss-of-load or load management. Unlike other contingencies, line outage requires the modification of the Jacobian of the base case power flow and the calculation of its new inverse, which is substantially different from the original inverse. In this paper, we obtain the inverse of the new Jacobian from the original inverse without repeating the time consuming matrix inversion process. Numerical test results show the significant improvement in the accuracies compared with those obtained using the original inverse.

  • PDF

Modeling and testing for hydraulic shock regarding a valve-less electro-hydraulic servo steering device for ships

  • Jian, Liao;Lin, He;Rongwu, Xu
    • International Journal of Fluid Machinery and Systems
    • /
    • v.8 no.4
    • /
    • pp.318-326
    • /
    • 2015
  • A valve-less electro-hydraulic servo steering device (short: VSSD) for ships was chosen as a study object, and its mathematic model of hydraulic shock was established on the basis of flow properties and force balance of each component. The influence of system structure parameters, changing rate of motor speed and external load on hydraulic shock strength was simulated by the method of numerical simulation. Experiment was designed to test the hydraulic shock mathematic model of VSSD. Experiment results verified the correctness of the model, and the model provided a correct theoretical method for the calculation and control of hydraulic shock of valve-less electro-hydraulic servo steering device.

A study on comparative analysis of direct current control in A.C.-D.C. interconnected power system (교류-직류 연계계통에 있어서 직류제어방식의 비교연구)

  • 정형환;왕용필;안병철;이광우
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.4
    • /
    • pp.474-483
    • /
    • 1996
  • In this paper, as a part of the method improving stability, the load-flow calculation in D.C. power system and the models for stability analysis are studied with A.C-D.C. interconnected power systems transmission performed. Moreover, the theory is established in relation to each control method of D.C. power systems. Then the stability of A.C-D.C.interconnected power systems is compared and considered by the way of dividing the operating control method of the rectifier inverter converter into ACR-AVR, APR-A.gamma.R, A.alpha.R-ACR. The dynamics characteristic of terminal voltage, frequency, active-reactive power and rotor angle of the generator with disturbances and load fluctuations is considered. In addition, the characteristic of direct voltage, direct current, power and control systems. From this the comparative analysis of the direct current control method, the possibility of the stability analysis of A.C.-D.C. interconnected power system is considered. (author). refs., figs., tabs.

  • PDF

Modeling of future power systems in metropolis by considering installation of superconductive power cable (초전도케이블 선로의 도입을 고려한 대도시 지역의 차기 전력계통 모델 구성 기초연구)

  • Kim, Sung-Il;Lee, Jong-Boom;Seong, Ki-Chul;Ryu, Kang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.865-867
    • /
    • 1996
  • This paper presents the power system basic planning in urban area, when the superconductive power cable is installed in power system in the future. To decide the proper superconductive cable routes, load flow calculation was carried out based on the long term load forecasting of kyoungin area. The simulated results show that installation of superconductive power cable is able to overcome rapidly growing power demand of unban area.

  • PDF

Effect of Source Line Location on Lift-off Acoustic Loads of a Launch Vehicle (음원 분포선 위치가 발사체 이륙 음향하중에 미치는 영향)

  • Choi, Sang-Hyeon;Ih, Jeong-Guon;Lee, Ik-Jin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.8
    • /
    • pp.539-545
    • /
    • 2015
  • Intense acoustic load is generated when a launch vehicle lifts off, causing the damaging vibrations at the launch vehicle or satellite within the fairing. This paper is concerned with the prediction of lift-off acoustic loads for a launch vehicle. As a test example, the lift-off acoustic load on the Korean launch vehicle, NARO, is predicted by the existing calculation tool, the modified Eldred's second method. Although the acoustic sources, assumed as point sources, are to be located along the center line of the exhaust plume when using the Eldred's prediction method, the exact location of the deflected center line of exhaust gas flow is not usually known. To search for the most appropriate source positions, six models of source line distribution are suggested and the acoustic load prediction results from these models are compared with the actual measurements. It is found that the predicted sound pressure spectrum of the Naro is the most similar to the measured data when the centerline of the turbulent kinetic energy contour is used as the source line.

A Comparison Study of the Bulbous Bow Shape for LPG Carrier (LPG 선박의 선수 Bulb 형상 비교 Study)

  • Lee Jongki;Park Jaesang;Kim Sungpyo
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2005.06a
    • /
    • pp.31-37
    • /
    • 2005
  • An attempt to improve the speed performance through the minimizing in wave resistance has been done by an application of gooseneck and no bulb type to bulbous bow for the DSME 78,500 Class LPG Carrier on the basis of the CFD calculation and comparatives model tests. The hydrodynamic characteristics according to the variation of the shape of Cp-curve, design load water line, frame line and bulbous bow that have an important effect on the wave resistance has been evaluated/calculated by ship-flow code. A wide variety in hull variation have been tried to have a good hull form with three types of fore-body hull forms mainly classified by the shape of bulbous bow. The speed performances for the three final hull forms with different bulbous bows have been evaluated through the model tests.

  • PDF

Effective Calculation Method Finding the Limit of Voltage-Stability (효율적인 전압안정도 한계점 계산에 관한 연구)

  • Song, K.Y.;Kim, S.Y.;Choi, S.G.
    • Proceedings of the KIEE Conference
    • /
    • 1991.11a
    • /
    • pp.35-38
    • /
    • 1991
  • Recent, problems on the voltage-instability have been paid attention in power system and methods to find the limit of voltage-stability, concerned with these problems, were developed. However, these methods are short of precision on the limit of voltage-instability. Here, using the second-order load flow, constraint equation(d Pi/d Vi=0) and its patial differentiations are precisely formulated. Also, since the taylor series expansion of power flow equations terminates at the second-order terms, partial differentiations of constraint equation, that is Hessian, are constant. Then, Hessian matrix are calculated once during iteration process.

  • PDF

An Investigation of Characteristics of the Operating Modes of Two-Module Thyristor Controlled Series Compensator

  • Chung, Gyo-Bum
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.903-908
    • /
    • 1998
  • This paper aims at investigating the characteristics of the operating modes of two-module Thyristor Controlled Series Compensator (TCSC) in a power transmission system. The operating modes of two-module TCSC are defined, analyzed and compared to those of single-module TCSC are defined, analyzed and compared to those of single-module TCSC. The load flow program, the stability calculation program and Electro Magnetic Transient Program (EMTP) simulation of a TCSC power transmission system are developed for the performance evaluation of two-module TCSC as a power flow controller. In the process of the simulation study, the potential problem areas of the TCSC power transmission system are identified.

  • PDF

Analysis of Opening Characteristics for Puffer GCB (파퍼식 가스차단기의 동작특성 해석)

  • Kim, Hong-Gyu;Jeong, Jin-Gyo;Park, Gyeong-Yeop
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.10
    • /
    • pp.560-567
    • /
    • 2002
  • This paper presents the calculation of opening characteristics for puffer GCB with the equations of the flow field and the motion of the driving mechanism. To obtain the stroke curve, the motion equation is solved simultaneously with the Euler equations. For a given Piston location, the flow field is solved. The pressure inside the Puffer chamber is then used to calculate the moving velocity and the new position of the piston. The FVFLIC method is employed to solve the axisymmetric Euler equations and the motion equation is solved by the Runge-Kutta method. The method is applied to the puffer GCB model and the stroke curve and the pressure rise in puffer chamber under no load condition are compared with the measured ones.

Development of IDS Program for Tuning Power System Controllers (전력시스템 제어기 튜닝을 위한 IDS 프로그램 개발)

  • Kim, D.J.;Kim, J.S.;Moon, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.38-40
    • /
    • 2003
  • This paper describes the integrated dynamic stability(IDS) program for tuning the power system controllers, such as PSS, AVR and so on. IDS consists of three modules; power flow module, PWRLF, to calculate large scale power system load flow solutions, IDS/PSS module to calculate eigenvalues and frequency response in the range of frequency from 0.2Hz to 2Hz, and IDS/NEA module to calculate eigenvalues in the range of frequency from 5.0Hz to 55Hz. In addition, IDS provides graphic user interface(GUI) in order to let the user handle and analyze the input data and the results of calculation with convenience.

  • PDF