• 제목/요약/키워드: Load factor

검색결과 3,059건 처리시간 0.03초

Ergonomics Risk-Assessment Methods in Shipbuilding: Application of OWAS Considering Work load and Frequency for Risk Factor Analysis of WMSDs

  • Lee, Jun-Youb;Seo, Hyun-Soo
    • 대한인간공학회지
    • /
    • 제31권1호
    • /
    • pp.185-189
    • /
    • 2012
  • Objective: The aim of this paper is to introduces Hyundai Heavy Industry's ergonomic risk assessment tool, H-OWAS, which is considering work load and frequency compared to the OWAS. Background: As prevalence of work-related musculoskeletal disorders(WMSDs) in ship building industries has been much higher than that in other industries, most of the large scaled corporations have implemented their own prevention program since legislation on the prevention of WMSDs had introduced in 2003. Method: This paper introduces WMSDs prevention program, HEMP(HHI Ergonomics Management Program) which consists of risk assessment, improvement efforts of working environments, medical treatment and training/evaluation and describes how to operate the program. We also describe application of OWAS method considering work load and frequency for risk factor analysis(H-OWAS) and shows methodology for assessing the ergonomic risk factor. And comparison of the assessment results between OWAS and H-OWAS is carried out by statistical analysis. Result: There was statistically significant difference in the assessment results between OWAS and H-OWAS, and regression shows H-OWAS explains the borg's scale of perceived exertion more clearly than OWAS. Conclusion: H-OWAS has been proved more effective tool than OWAS to evaluate ergonomic risk factor under real working condition. Application: H-OWAS can be widely applied to the many other companies when implementing the ergonomics risk assessment.

입력전압을 감지하지 않는 전류연속/임계동작모드 Active Power Factor Correction Circuit (A Continuous Conduction mode/Critical Conduction Mode Active Power Factor Correction Circuit with Input Voltage Sensor-less Control)

  • 노용성;유창식
    • 전자공학회논문지
    • /
    • 제50권8호
    • /
    • pp.151-161
    • /
    • 2013
  • 본 논문에서는 입력전압을 감지하지 않는 전류연속/임계동작모드 active power factor correction(PFC) circuit을 제안하였다. 기존의 입력전압을 감지하지 않는 PFC circuit의 경우 출력전류가 낮은 경 부하 조건에서 DCM 동작을 수행하고, 이에 따라 PF가 감소하는 문제가 발생한다. 제안한 PFC circuit은 70KHz의 주파수로 CCM 동작을 수행하고, 경 부하 조건에서 최대 200KHz까지 스위칭 주파수가 가변되는 CRM 동작을 수행하도록 하였다. 이를 통해 경 부하 조건에서 PF가 감소하는 문제를 해결하였다. PFC controller IC는 $0.35{\mu}m$ BCDMOS 공정을 이용하여 제작하였으며, 240W급 PFC prototype을 제작하여 실험하였다. 제안한 PFC circuit은 기존의 PFC circcuit 대비 최대 10%의 역률이 향상되었고, IEC 61000-3-2 Class D 규격에 따른 경 부하 조건에서는 최대 4% 역률이 향상되었다.

Buckling analysis of semi-rigid gabled frames

  • Rezaiee-Pajand, Mohammad;Shahabian, Farzad;Bambaeechee, Mohsen
    • Structural Engineering and Mechanics
    • /
    • 제55권3호
    • /
    • pp.605-638
    • /
    • 2015
  • It is intended to perform buckling analysis of steel gabled frames with tapered members and flexible connections. The method is based on the exact solutions of the governing differential equations for stability of a gabled frame with I-section elements. Corresponding buckling load and subsequently effective length factor are obtained for practical use. For several popular frames, the influences of the shape factor, taper ratio, span ratio, flexibility of connections and elastic rotational and translational restraints on the critical load, and corresponding equivalent effective length coefficient are studied. Some of the outcomes are compared against available solutions, demonstrating the accuracy, efficiency and capabilities of the presented approach.

핵연료집합체 안내관의 하중집중계수 해석 (Load Concentration Factor Analysis of Fuel Assembly Guide Thimble)

  • 이영신;전상윤
    • 한국정밀공학회지
    • /
    • 제22권3호
    • /
    • pp.93-100
    • /
    • 2005
  • The top and bottom nozzles of PWR fuel assembly are connected by guide thimbles and an instrumentation tube that are connected with spacer grids. The fuel rods are inserted into the each cell of spacer grids. The loads acting on the fuel assembly are transmitted to the guide thimbles through the flow plate of top nozzle The axial loads applied to the fuel assembly are not equally distributed among the guide thimble due to the geometry of the top nozzle flow plate and spacer grid. In this study, the load concentration factors for the $17\times17$ fuel assembly were calculated. The analytical model fur the calculation of the load concentration factor of top nozzle flow plate was developed using ANSYS 5.6. The finite element analyses were performed using the model composed of top nozzle, guide thimble, and spacer grid. And, the analysis results were compared with the test results.

전압, 전류 및 부하 불평형율에 대한 비교 연구 (The Comparison Study for Voltage, Current and Load Unbalance Factor)

  • 김종겸;박영진;정종호;이은웅
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 학술대회 논문집
    • /
    • pp.115-120
    • /
    • 2004
  • Most of the LV customer have been applied the distribution system of 3-phase four wire system because of its advantage of supplying both of 1-phase & 3-phase loads simultaneously. Due to its structural simplicity, it is more convenient for use rather than the conventional separated scheme. But uneven load distribution or unclean voltage quality has occurred various problems such as do-rating, losses increase and vibration, etc. In this paper, voltage, current and power waveform in the actual fields have measured and analyzed in relation with internationally allowable voltage unbalance limits and compared the current unbalance factor with the load unbalance factor.

  • PDF

Fuzzy Decision을 사용한 단기부하예측 전문가 시스템 (An Expert System for Short Term Load Forecasting by Fuzzy Decision)

  • 박영일;박종근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 추계학술대회 논문집 학회본부
    • /
    • pp.118-121
    • /
    • 1988
  • Load forecasting is an important issue as for the economic dispatch and there have been many researches which are classfied into two classes, time series method and factor analysis method. But the former is not adaptive for a sudden change of a correlated factor and the latter is not inefficient as the factor estimation is not easy. To make matters worse, both of them are not good for the estimation of special days. It is because the load forecasting is not a problem modeled precisely in mathematics, but a problem requires experience and knowledge those can solve it case by case. In this viewpoint, an expert system is proposed which can use complicated experience of an expert by use of fuzzy decision.

  • PDF

부하제어 기능을 갖는 디지털형 전동기제어반의 설계 및 구현 (Design and Implementation of Digital Motor Control Center Including Load Control Function)

  • 우천희;강신준;이덕규;구영모;김학배;이성환
    • 제어로봇시스템학회논문지
    • /
    • 제5권7호
    • /
    • pp.868-875
    • /
    • 1999
  • In this paper, digital motor control center using protection relay is developed in order to protect power systems by means of timely fault detection and diagnosis during operation for induction motor which have various load environments and capacities in power systems. Digital motor control center is employed by power supervisory control systems without separate remote terminal unit and transducers adding communicational ability. Also we develope a maximum demand controller to control the load effectively at peak status and a power factor controller to minimize real power losses and improve the power factor. Therefore, when using the developed controller, real time computation is possible by loading DSP in hardware and applying real-time kernel which can convert each algorithm to task module.

  • PDF

싸이리스터 정류부하를 위한 새로운 저원가 복합형 전력필터 (A New Low Cost Hybrid Power Filter for Thyristor-Controlled Rectifier Load)

  • 한성룡;김수근;석원엽;조정구;송의호;전희종
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권1호
    • /
    • pp.24-29
    • /
    • 2004
  • A new low cost hybrid active filter for thyristor-controlled rectifier load is presented to overcome the high cost problem of the active or the other hybrid active filters. The proposed hybrid active filter which consists of tuned (5th and 7th harmonics) LC passive filters, power factor improvement(PFI) capacitor bank, and active filter compensates power factor as well as harmonic currents. Since most of harmonic currents are filtered by the passive filter and most of reactive power is compensated by the PFI capacitor bank, the power rating of active filter can be minimized, resulting in cost minimization of the proposed hybrid active filter. A 300kVA hybrid active filter system is implemented and tested using 1MVA thyristor rectifier load to verify the operation and performance.

Design of a Power Factor Measurement System for Nonlinear Load

  • Shahriar, Md. Rifat;Chong, Ui-Pil
    • 조명전기설비학회논문지
    • /
    • 제25권11호
    • /
    • pp.113-122
    • /
    • 2011
  • This paper introduces and develops an efficient method for measuring power factor (PF) and its nature under nonlinear load current situations. The method is based on generating a pulse width modulated signal whose width correlates to the value of PF. This signal can then be employed as a feedback signal for controlling PF related power quantities in a system. This method has the advantages of its simple implementation, less computational complexity, and its allowable error of less than 4[%], which is justified by the computer simulation results.

수용가용 STATCOM을 이용한 3상 유도전동기의 이론적인 역률 보상 (The Theoretical Power-factor Correction of a 3-phase Induction Motor using Customer STATCOM)

  • 임수생;이은웅;최재영;김홍권
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권7호
    • /
    • pp.475-482
    • /
    • 2000
  • This paper presents a novel power-factor correction method using customer STATCOM which generally improves the power quality of electric customers. Customer STATCOM detects the reactive currents of a induction motor(IM) and so injects compensation currents which is in 180$^{\circ}$ phase with load currents that the reactive power of IM is compensated. In particular, the paper proposes the general compensation current references in the synchronous coordinate system and makes converter output voltages using space-vector PWM. The compensation effect of customer STATCOM is confirmed through the simulation according to the operation condition of an induction motor (at no load and full load).

  • PDF