• 제목/요약/키워드: Load equation

검색결과 1,550건 처리시간 0.027초

자유 공중 폭발하중 파라메타의 수정 산정식 (A Modified Equation of Parameter of Free-air Blast Load)

  • 전두진;이민재;한상을
    • 한국공간구조학회논문집
    • /
    • 제16권4호
    • /
    • pp.117-123
    • /
    • 2016
  • The blast load is classified into free-air blast and surface blast following the location of explosion and surface. In this paper, several equations for blast load calculation are explained briefly and a modified equation for free-air blast load is suggested. The modified equation is based on Kingery-Bulmash equation which is used in UFC 3-340-02 and Conwep model. In this modified equation, the process of calculation is simplified against the original equation, and the number of coefficients is reduced under 5. As a result, each parameter of estimated data by modified equation has less than 1% of error range comparing with Kingery-Bulmash equation.

표면 폭발하중 파라메타의 수정 산정식 (A Modified Equation of Parameter of Surface Blast Load)

  • 전두진;김기태;한상을
    • 한국공간구조학회논문집
    • /
    • 제17권3호
    • /
    • pp.75-82
    • /
    • 2017
  • The Kingery-Bulmash equation is the most common equation to calculate blast load. However, the Kingery-Bulmash equation is complicated. In this paper, a modified equation for surface blast load is proposed. The equation is based on Kingery-Bulmash equation. The proposed equation requires a brief calculation process, and the number of coefficients is reduced under 5. As a result, each parameter obtained by using the modified equation has less than 1% of error range comparing with the result by using Kingery-Bulmash equation. The modified equation may replace the original equation with brief process to calculate.

주상변압기 부하 상관식 조정에 관한 실증적 연구 (Practical Study on Adjustment of Load Correlation Equations of Pole Transformer)

  • 박창호;김두봉;김기현;배주천;윤상윤;김재철
    • 조명전기설비학회논문지
    • /
    • 제14권1호
    • /
    • pp.102-108
    • /
    • 2000
  • 본 논문은 주상변압기의 부하관리를 위한 부하 상관식 조정에 관한 실증적 연구 결과를 제시하였다. 부하 상관식 조정을 위하여 주상 변압기의 사용전력량[kWh]과 최대 부하[A] 사이의 상관 관계를 분석하였다. 또한 상관식의 정확성을 높이기 위하여 12개의 지역 패턴으로 분류하였다. 그리고 각 지역 패턴에 24개씩의 표본 주상 변압기를 선정하였다. 부하 상관식에 사용된 데이터의 신뢰성을 위하여 표본 주상변압기에 부하관리기를 설치하였다. 온-라인 데이터 취득을 통하여, 데이터 베이스를 구축하였다. 부하 상관식 조정에 있어서 본 논문에서는 두 부분에 대해 고려를 하였다. 그중 하나는 부하 상관식의 적합성 또 하나는 과부하로 인한 주상변압기 손실 방지이다. 최종적으로 1, 2차 상관함수를 병용하는 상관식올 제안하였다. 또한 사례 연구를 통하여 제안한 부하 상관식이 기존에 사용하는 상관식 보다 오차 비율이 감소했음을 입증하였다.

  • PDF

해저 석유개발을 위한 해양구조물의 기본 설계/해석 및 실험기법 개발 -해양구조물에 작용하는 파랑하중 산정에 관한 연구 (A Study on the Determination of Wave Load Acting on Offshore Structures)

  • 이근무
    • 한국해양공학회지
    • /
    • 제14권1호
    • /
    • pp.6-10
    • /
    • 2000
  • In this paper various methods of determining of wave loads acting ofshore structures including impact load due to breaking wave are studied and corresponding model test was performed. In the theoretical approach wave load by nonbreaking wave and impact load by breaking wave is determined by Morrison's equation Goda's equation and impact wave equation, In the experimental approach wave load by nonbreaking wave acting on cylindrical pile used in offshore structures is determined by measuring the strain on a cylindrical pile and compared with theoretical calue. in the numerical approach impact load by breaking wave acting on a modeled cylindrical pile is calculated by usign ANSYS FEM program and compared with theoretical value. It is found that the experimental and numerical results are comparable to theoretical results, Thus the determination of wave load acting on offshore structures can be obtained by a proposed methods and it acceptable.

  • PDF

창원시 학교 건축물의 냉난방부하에 대한 전력 소비량 추정에 관한 연구 (A Study on Prediction of Power Consumption Rate for Heating and Cooling load of School Building in Changwon City)

  • 박효석;최정민;조성우
    • 교육녹색환경연구
    • /
    • 제11권2호
    • /
    • pp.19-27
    • /
    • 2012
  • This study was carried out in order to establish the estimation equation for school power consumption using regression analysis based on collected power consumption for two years of weather data and schools are located in Central Changwon and Masan district in Changwon city. (1) The power consumption estimation equation for Heating and cooling is calculated using power consumption per unit volume, the difference between actual power consumption and results of estimation equations is 4.1%. (2) The power consumption estimation equation for heating load is showed 2.6% difference compared to actual power consumption in Central Changwon and is expressed 2.9% difference compared to that in Masan district. Therefore, the power consumption prediction for each school using the power consumption estimation equation is possible. (3) The power consumption estimation equation for cooling load is showed 8.0% difference compared to actual power consumption in Central Changwon and is expressed 2.9% compared to that in Masan district. As the power consumption estimation equation for cooling load is expressed difference compared to heating load, it needs to investigate influence for cooling load.

사용전력량에 의한 주방변압기의 최대 부하 예측 (The Peak Load Forecast of Pole-Transformers by Working Electrical Energy)

  • 이동준;한성호;이욱;곽희로;김재철
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1996년도 추계학술발표회논문집
    • /
    • pp.101-103
    • /
    • 1996
  • This Paper describes Peak load forecasting technique of pole transformers with correlation equation. While customers are demanding safe energy supply, current correlation equation that is used for load management of pole transformers has some problems. To get accurate correlation equation. several correlation equation were examined using past data and nu data collected using the measuring instrument developed for this study. It was recognized that the quadratic equation was the most accurate for peak load forecasting from working electrical energy.

  • PDF

Einstein 부유사량 산정식의 개선 (Improvement of Einstein's Suspended Load Equation)

  • 유동훈;신승호;임학수
    • 한국수자원학회논문집
    • /
    • 제33권6호
    • /
    • pp.815-825
    • /
    • 2000
  • Einstein(1942)의 부유사량 산정식 유도과정에 있어 몇 가지 문제점들을 개선하였다. 수류조건을 판별하여 완난류 조건에서 유속의 영점높이를 산정하는 방법을 제시하고 부유사량 산정식을 일반화할 수 있는 무차원수를 도입하였다. 또한, 기준점 농도 산정의 정확성을 개선하기 위하여 최근에 개발된 소류사량 산정식으로부터 관련치를 추정하였으며, 수치적으로 또는 도표를 이용하여 해를 구해야 하는 수심적분치의 근사식을 개발하였다. Einstein의 기존 부유사량 산정식과 개선된 부유사량 산정식의 정확도를 검토하여 Brownlie(1981)가 수집한 자료에 대한 산정결과를 제시하였다.

  • PDF

논 물꼬관리 기법 적용에 따른 원단위 삭감부하량 산정식 평가 (Assessing the Unit Load Reduction Equation of Drainage Outlet Raising Management in Paddy Fields)

  • 김동현;오흥근;장태일;함종화
    • 한국농공학회논문집
    • /
    • 제65권2호
    • /
    • pp.35-45
    • /
    • 2023
  • The DOR (Drainage outlet raising) in the paddy field has been suggested as one of the most important best management practices for the TMDL (Total maximum daily load) management in the technical guidelines by the NIER (National institute of environmental research). However, this method is underestimated and is not well adopted by local governments for the TMDL. The purpose of this study is to evaluate the unit load reduction equation according to the application of DOR in order to expand this equation. The original equation in the guideline was derived using the HSPF (Hydrological Simulation Program-Fortran) model for 1 year in Changnyeong. We analyzed the reduction effect of the original equation application by collecting additional long-term monitoring data from the Buan, Icheon, Iksan, and Jeonju. When comparing the reduction loads between the original equation and monitoring results, the evaluation results of the original equation were 11% of the monitoring analysis results, which was underestimated. This means that the original equation needs to be improved. For assessing the equation, the HSPF Paddy-RCH model was established according to the NI ER guideline and evaluated for applicability. The performance results of the model showed a reasonable range by the statistical criteria. Modified equations 1 and 2 were proposed based on the monitoring and modeling results. Modified equation 1 was the method of modifying the original equation's main factors, and modified equation 2 was the method of applying the non-point pollution reduction efficiency according to the rainfall class using the long-term modeling results. At the level of 58.6~64.6% of monitoring data, the difference between them could be further reduced compared to the original equation. The suggested approach will be more reasonable and practicable for decision-makers and will contribute to the TMDL management plans.

전력시설물 설계를 위한 풍하중 산정식 (Wind load equation for electric power facility design)

  • 최상현;서경석;이수형
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.42-54
    • /
    • 2009
  • The wind load equation for the design of electric power facilities such as electrical pole in railroad is based on the maximum wind velocity without considering regional difference in wind velocities. Also, the use of a different equation to highspeed railroad and the possibility of higher wind speed due to climate change claims a new design equation. In this paper, a wind load equation based on wind speed measurement data to date, which is applicable to both conventional and highspeed railroad is proposed. The proposed equation considers the regional differences in wind speed for economic and effective design, and the possibility of higher wind speed due to climate change.

  • PDF

기존선 궤도의 충격계수 산정에 관한 연구 (Evaluation of Track Impact Factor in the Conventional Line)

  • 엄주환;유영화;엄기영
    • 한국철도학회논문집
    • /
    • 제6권4호
    • /
    • pp.239-245
    • /
    • 2003
  • In this paper, the track impact factor of conventional line was evaluated using the data for wheel load measured in field and the properties of current operating trains. The equation for track impact factor was presented through the statistical analysis of variational ratio in wheel load and compared with other design equations in domestic and foreign countries. A review on the safety of track system in conventional line was made from the relationship between the velocity and the corresponding impact factor. It was found that the impact factor from the proposed equation is a little less than the values from the equations adopted in both AREA and domestic railway, while it is same as the equation for continuous welded rail(CWR) in Japan. Therefore it could be said that the track satisfies a criteria for dynamic load caused by the train and the corresponding level of safety is guaranteed for dynamic load of the train