• Title/Summary/Keyword: Load device

Search Result 1,287, Processing Time 0.032 seconds

Design and Implementation of a Multi-Interface Access Point with Inter-interface Dynamic Load Balancing (인터페이스간 동적 부하 분배를 고려한 다중 인터페이스 액세스 포인트 설계 및 구현)

  • Kim, Tae-Keun;Seo, Hyung-Yoon;Kim, Jong-Deok
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.5A
    • /
    • pp.348-357
    • /
    • 2012
  • Recently, smartphone, notebook, PC and other supporting wireless LAN device have come into wide use. By increasing user that use wireless LAN device, wireless traffic also increased. If wireless traffic through one AP is increase, it causes throughput decrease. To solve this problem, wireless LAN service provider install more AP where overload occurred. But this is not enough. Because stations can't know AP's load factor, and APs do nothing for load balancing. In this paper, we propose Multi-Interface Access Point(MIAP) to solve this problem. MIAP operate same as multiple APs with multi-interface, and MIAP measure each interface's load periodically. If MIAP detect overloaded interface, MIAP transfer station from overloaded interface to under-loaded interface. We conducted an experiment for verifying existing problem, and we found this problem occurred. We plan an experiment scenario for a comparison between existing AP and MIAP, and excute these experiment. In the result, we show MIAP with load balancing can improve total throughput about 72% and stabilize delay jitter than existing AP.

Development of a Digital Cone Index Measuring Device (디지털 원추관입기 개발)

  • Lee, Kyou-Seung;Lee, Dong-Hoon;Cho, Yong-Jin;Chung, Sun-Ok;Park, Won-Yeop;Noh, Kwang-Mo;Chang, Young-Chang
    • Journal of Biosystems Engineering
    • /
    • v.35 no.6
    • /
    • pp.387-392
    • /
    • 2010
  • This study was performed to design and to construct a digital soil cone index(CI) measuring device replacing conventional analog type devices. The device developed in the study consisted of a load cell, a rotary encoder and a motor with a decelerator as its main parts. The cone speed was controlled lower than 3.0 m/s which keeps the standard suggested by the ASABE S313.3 specification. The experiment was conducted in a soil bin system as well as in various fields. The CI data measured by the developed device were compared with those by an existing measurement device(SC900, Spectrum, USA). Based on the experiments at various field conditions, the CI measuring characteristic of the device was quite similar to that of the conventional device within a acceptable $R^2$ range of more than 0.5(mean=0.76). It was concluded that the digital cone index measuring device was an effective and comprehensive sensor for measuring soil strength.

An Experiment of Structural Performance of Expansion Joint with Rotation Finger (가변형 핑거 조인트를 가지는 신축이음장치의 구조 성능 실험)

  • Yoo, Sung won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.6
    • /
    • pp.170-175
    • /
    • 2018
  • For the seismic performance, it is necessary to prevent the destruction of the expansion joint device due to the appropriate deformation of the expansion joint device due to the seismic force. Recently, the hinge is installed on the fingering of the expansion joint device in Korea, New products are being developed. In this paper, we have experimentally evaluated the real scale resistance of the expansion joints with rotational finger joints against load at right angle to the bridge axis. Experimental results show that the maximum horizontal displacement is about 21.1mm for conventional stretch joints and 51.00mm for seismic stretch joints. It is presumed that the existing expansion joint test specimen is resistant to the load in a direction perpendicular to the throat axis, and then the bending and shear deformation of the finger are excessively generated and the fracture phenomenon is likely to occur. On the other hand, in the case of the seismic expansion joint, the deformation of the load due to the load is absorbed by the hinge of the finger with respect to the load in the direction perpendicular to the throat, so that only horizontal deformation in the direction of load action.

The Study on the Actual Examination of the Bidirectional Protection Device in the 22.9[kV] Distribution Power System Interconnected with the DG (분산전원이 연결된 22.9[kV] 배전계통의 양방향 보호기기 실증시험 연구)

  • Lee, Heung-Jae;Choi, Myeong-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.10
    • /
    • pp.102-108
    • /
    • 2011
  • The existing power flow has a single direction to the line end but the bidirectional power flow will possibly occur depending on the output capacity in the 22.9[kV] distribution power system connected with the dispersed generation(DG). So these characteristics would influence the power system management. The DG have many advantages such as assistance source, Load share etc. So the utility must apply the bidirectional protection system so as to maximize an advantage of DG. This paper describes the field test case of bidirectional protective device in order to investigate the device performance when applied to bidirectional power system. We have tested in the power system test site of KEPCO and these tests provide the basis for performance verification test of bidirectional protective device in the power system.

Design of A Force-Reflecting Device and Embedded Controller

  • Kim, Dae-Hyun;Moon, Cheol-Hong;Choi, Han-Soo;Kim, Yeong-Dong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2397-2401
    • /
    • 2005
  • It is well understood that force reflecting coupled with visual display can be an important two-way communication channel in human-computer interaction. In this work, important components for a high-fidelity system bandwidth are force reflecting device and that all the computations including contact determination and response computation have to be performed in less than a millisecond. This paper describes a force-reflecting device and an embedded controller. The realized force-reflecting device is based on a novel serial type mechanical structure, and features compactness, high sustained output force capability, low friction, zero backlash, and enough workspace. The embedded controller reduces software computational load via main processor and simplifies hardware strictures by the time-division control. The device is integrated with existing dynamic simulation algorithms running separate workstation, so that objects can be manipulated in real time and the corresponding forces felt back by the operator.

  • PDF

A Study on Characteristics of a Pneumatic Device for Deploying Fins (공압식 날개전개장치 특성 연구)

  • Kang, Choon-Kil;Won, Myong-Shik
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.365-371
    • /
    • 2010
  • The fins of a missile which is folded within a canister are deployed according to a command during the missile flight. The aerodynamic load generated by operating environments such as missile flight speed, platform movement speed and wind acts as an anti-deploying force and prevents the fins from deploying. As the diversification of platforms and the higher speed of missiles need a larger deploying force but the space for operating the fin deploying device is getting narrower, the new design concepts are required for developing such a device. In this study, a pneumatic device for deploying missile fins is designed and its characteristics are verified through experiments and analyses.

Development of Multi-Axes Chain Hoist Servo Systems for Lifting Heavy Loads (고하중 이송 멀티 체인 호이스트 서버 시스템 개발)

  • Park, Jaehwan;Kwon, Ohung
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.8
    • /
    • pp.46-52
    • /
    • 2015
  • Most stage directors and designers make use of controling and moving lots of stage set or device as a large automation device or machine to achieve dramatic effect in their performances. Specially, it is very important to use a programmable multi-chain hoist system which is able to move high speed as well as to lift heavy loads. This paper proposes a multi chain hoist servo system to lift or lower a heavy load of about l ton for public performances' stage. It is automatically operated, electrically driven by a control console with a PTP trajectory generation algorithm, a realtime network control algorithm, and 4 step sequential safety algorithm. The efficiency and performance of the developed system are verified through a series of experiments.

Process Development of a Standard Operating Procedure (SOP) for the Manufacturing of Standardized Distribution Boards (규격화된 분전반 제작을 위한 표준작업절차(SOP)의 공정 개발)

  • Ko, Wan-Su;Lee, Byung-Seol;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.5
    • /
    • pp.21-27
    • /
    • 2018
  • The purpose of this study is to develop a SOP (Standard Operating Procedure) for a distribution board that can monitor the leakage current of a load distribution line in real time. The developed distribution board was fabricated by applying IEC 61439-1. It consists of the distribution board and an alarm device. The work process for making the distribution board was compliant with the KEMC (Korea Electrical Manufacturers Cooperative) regulations. And the AC distribution board range is 1,000 V. In addition, the voltage in DC is less than 1500 V. The distribution board receives a 3-phases and 4-wires power supply system and can supply power to the load of a maximum of 32 single or three phase distribution circuits. Also, leakage current measured on the power distribution board was used by sensors installed. The SOP of the developed distribution board consists of the installation standards for the short circuit alarm device and sensor, the surge protection device, switches and indication lamps, and other devices. The operation procedure was prepared so that each manufacturing step of the distribution board must be confirmed by the persons in charge of preparation, production, quality control and approval before moving forward to the next step.

Arc Extinguishment for Low-voltage DC (LVDC) Circuit Breaker by PPTC Device (PPTC 소자를 사용한 저전압 직류차단기의 아크소호기술)

  • Kim, Yong-Jung;Na, Jeaho;Kim, Hyosung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.5
    • /
    • pp.299-304
    • /
    • 2018
  • An ideal circuit breaker should supply electric power to loads without losses in a conduction state and completely isolate the load from the power source by providing insulation strength in a break state. Fault current is relatively easy to break in an Alternating Current (AC) circuit breaker because the AC current becomes zero at every half cycle. However, fault current in DC circuit breaker (DCCB) should be reduced by generating a high arc voltage at the breaker contact point. Large fire may occur if the DCCB does not take sufficient arc voltage and allows the continuous flow of the arc fault current with high temperature. A semiconductor circuit breaker with a power electronic device has many advantages. These advantages include quick breaking time, lack of arc generation, and lower noise than mechanical circuit breakers. However, a large load capacity cannot be applied because of large conduction loss. An extinguishing technology of DCCB with polymeric positive temperature coefficient (PPTC) device is proposed and evaluated through experiments in this study to take advantage of low conduction loss of mechanical circuit breaker and arcless breaking characteristic of semiconductor devices.

A Study on the Limited Rate Power Capacity for Applications for Precision Passive Devices Based on Carbon Nanotube Materials (탄소나노튜브 소재의 정밀 수동소자 적용을 위한 한계 정격전력 용량에 관한 연구)

  • Lee, Sunwoo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.3
    • /
    • pp.269-274
    • /
    • 2022
  • We prepared carbon nanotube (CNT) paper by a vacuum filtration method for the use of a chip-typed resistor as a precision passive device with a constant resistance. Hybrid resistor composed of the CNT resistor with a negative temperature coefficient of resistance (T.C.R) and a metal alloy resistor with a positive T.C.R could lead to a constant resistance, because the resistance increase owing to the temperature increase at the metal alloy and decrease at the CNT could counterbalance each other. The constant resistance for the precision passive devices should be maintained even when a heat was generated by a current flow resulting in resistance change. Performance reliabilities of the CNT resistor for the precision passive device applications such as electrical load limit, environmental load limit, and life limit specified in IEC 60115-1 must be ensured. In this study, therefore, the rated power determination and T.C.R tests of the CNT paper were conducted. -900~-700 ppm/℃ of TCR, 0.1~0.2 A of the carrying current capacity, and 0.0625~0.125 W of the rated power limit were obtained from the CNT paper. Consequently, we confirmed that the application of CNT materials for the precision hybrid passive devices with a metal alloy could result in a better performance reliability with a zero tolerance.