• Title/Summary/Keyword: Load Shedding

Search Result 166, Processing Time 0.028 seconds

A New Way of Connecting Method Between Steel Pipe Pile and Concrete Footing (새로운 강관말뚝 머리 보강 공법 개발)

  • 박영호;김낙영;박종면;유성근;김영호
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.413-420
    • /
    • 2002
  • Recent experimental research results of connection method between steel pipe pile and concrete footing are provided based on various experimental observations. It gives a shedding light toward developing better and concrete connection method for steel pipe pile at the field application. In this study, the newly developed method is tested for compressive, pull put and combination load including moment with carefully designed monitoring system. The measured data show that new method have at least equivalent or better load resistant capacities compared with those of specified method in Korea Highway Corporation design code. It is also tried to define and investigate the load transfer mechanism for new method.

  • PDF

Study on the Characteristic of System Frequency Decay In Case of Large Generator Unit Outage (전원탈락에 따른 계통주파수저하문제검토 제1보)

  • 송길영
    • 전기의세계
    • /
    • v.18 no.3
    • /
    • pp.7-14
    • /
    • 1969
  • According to the construction of Seoul Thermal #5 (250MW) unit, there will be prospected several new problems on the power system operation. This paper describes the characteristic of system frequency decay during severe emergencies which result in sudden outage of such large generator unit. It also studies the factors involved in applying under frequency relays to maintan an allowable frequency level and to prevent total area collapse by automatic load shedding program.

  • PDF

OPERATION MODES ANALYSIS FOR A DVR IN DISTRIBUTION GRIDS

  • Kim, Hyo-Sung;Kim, Pederson John
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.480-483
    • /
    • 2001
  • Recent power quality measurement projects report that voltage sags are the most frequent disturbances in the sites [1]-[4]. DVRs were emerged as the best effective and economic solution for this problem [11]. This paper analyzed the power flow of a DVR in distribution grids. This paper showed various operation modes and boundaries such as inductive operation, capacitive operation, and minimal power operation beside the in-phase compensation.

  • PDF

Study On The Characteristic Of System Fluctuation Under Large Generator Unit Outage (대전원타락사고시의 계통동요특성 해석)

  • 송길영;이종훈;김영창
    • 전기의세계
    • /
    • v.24 no.2
    • /
    • pp.71-77
    • /
    • 1975
  • This paper describes the results of a study for the stability of power system when the Kori Nuclear #1 P/P is operated with existing system. First, a transient disturbance, which effects the stability of entire power system, was analysed and to cope with the problem a load shedding method was studied to recover the fluctuation of the power system. Second, transient stability problem was studied when three phase fault occurs in 345 Extra High Voltage power System, and from this result, it was found to be highly effective that high speed protecting device should be provided and operated to recover the fault.

  • PDF

Comparative Analysis for the Frequency Estimation Algorithms (주파수 변화 추정 알고리즘 비교분석)

  • Kim, Chul-Hun;Kang, Sang-Hee;Nam, Soon-Ryul;Kim, Su-Whoan
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.2199-2200
    • /
    • 2006
  • Reliable frequency estimation is important for active power control, load shedding and generator protection. Thereby, frequency estimation is researched and some algorithms is proposed. This paper analyzed strength and weakness of each algorithms through comparative analysis of frequency estimation. Used algorithms are Zero Crossing detection, Discrete Fourier Transformation, Least Error Squares.

  • PDF

Fast Acting Load Shedding and Network Split System Using PLC (PLC를 이용한 고속동작 부하차단 및 계통분리 시스템)

  • Yu, Young-Sik;Oh, Seok-Bong;Lee, Kang-Wan
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.27-29
    • /
    • 2005
  • 자가디젤발전기를 운전하고 있는 산업체 전력계통에서 전력공급의 신뢰성을 높이기 위해 전력치사와의 연계선 분리에 따른 수급 불균형과 전력회사 계통 동요로 인한 계통 불안정 상태에 대처하기 위한 부하차단 및 계통분리 안정화 시스템을 고속동작이 보장되는 PLC로 구축하여 현장에 적용한 연구 사례이다.

  • PDF

Comparative Analysis for the Frequency Estimation Algorithms (주파수 변화 추정 알고리즘 비교분석)

  • Kim, Chul-Hun;Kang, Sang-Hee;Nam, Soon-Ryul;Kim, Su-Whoan
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.567-568
    • /
    • 2006
  • Reliable frequency estimation is important for active power control, load shedding and generator protection. Thereby, frequency estimation is researched and some algorithms is proposed. This paper analyzed strength and weakness of each algorithms through comparative analysis of frequency estimation. Used algorithms are Zero Crossing detection, Discrete Fourier Transformation, Least Error Squares.

  • PDF

Optimal Power Flow with Linear Programming (선형계획법을 이용한 최적조류계산)

  • Jung, G.H.;Baek, Y.S.;Song, K.B.;Chu, J.B.;Won, J.R.
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.145-148
    • /
    • 2000
  • This paper presents new algorithm which is based on LP(Linear Programming) that guarantee convergence. It is considered to minimize generation cost and load shedding as object function subject to various constraints. The proposed algorithm use sensitivity matrix to re-dispatch generation power, so the total CPU time is saved.

  • PDF

Linear programming技法에 있어서 Basic Matrix의 Bartels-Golub Decomposition 및 그 응용

  • 문영현
    • 전기의세계
    • /
    • v.32 no.11
    • /
    • pp.664-669
    • /
    • 1983
  • 대규모 system을 취급하는 공학분야에 있어서 Matrix의 demension이 커짐에 따라 전산부담을 줄이기 위한 소요기억용량 절감 및 계산시간의 단축이 주된 관심사 중의 하나가 되어 왔다. LP(Linear Programming)기법 역시 대규모 선형 system에 적용될 경우 Basic Matrix 에 대한 dimensionality 문제를 포함하고 있으며 이에 대한 효과적인 해결방법으로 Bartels-Golub Decomposition 방법이 연구되어 있다. 이 방법은 Chan과 Yip등이 LSGA(Load Shedding and Generator Rescheduling) 문제에의 적용을 시도한 바 있으며, 일반적인 선형최적화 문제뿐만 아니라, dimensionality가 큰 Matrix의 Inverse 계산을 요하는 문제에 널리 적용될 수 있으므로 그 개요를 소개하고자 한다.

  • PDF

Comparative Analysis for the Frequency Estimation Algorithms (주파수 변화 추정 알고리즘 비교분석)

  • Kim, Chul-Hun;Kang, Sang-Hee;Nam, Soon-Ryul;Kim, Su-Whoan
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1233-1234
    • /
    • 2006
  • Reliable frequency estimation is important for active power control, load shedding and generator protection. Thereby, frequency estimation is researched and some algorithms is proposed. This paper analyzed strength and weakness of each algorithms through comparative analysis of frequency estimation. Used algorithms are Zero Crossing detection, Discrete Fourier Transformation, Least Error Squares.

  • PDF