• Title/Summary/Keyword: Load Reducing

Search Result 1,097, Processing Time 0.032 seconds

Influence of eccentric load and lateral earth pressure on the tunnel behavior (편토압 및 측압이 터널거동에 미치는 영향)

  • Ahn, Hyun-Ho;Suh, Byung-Wook;Kim, Dong-Hyun;Min, Dong-Ho;Lee, Sun-Bok;Lee, Seok-Won
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.9 no.3
    • /
    • pp.219-228
    • /
    • 2007
  • Scaled model tests were performed to explore the influence of eccentric load and lateral earth pressure on tunnel behavior and their results were verified through numerical analyses. As a method for reducing the eccentric load acting on tunnel, an eccentric supporting system (ESS) was proposed and its applicability was investigated. Experimental results showed that displacement decreased overall and the load inducing initial cracks increased as the eccentric supporting system was applied. The maximum eccentric vertical load which impacted the stability of tunnel was also increased. The test results on the influence of lateral earth pressure on tunnel behavior showed that the general aspect of displacement and crack growth changed significantly depending on the coefficient of lateral earth pressure. In addition, the weak zone In view of stability varied as well.

  • PDF

Deep Neural Network Model For Short-term Electric Peak Load Forecasting (단기 전력 부하 첨두치 예측을 위한 심층 신경회로망 모델)

  • Hwang, Heesoo
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.5
    • /
    • pp.1-6
    • /
    • 2018
  • In smart grid an accurate load forecasting is crucial in planning resources, which aids in improving its operation efficiency and reducing the dynamic uncertainties of energy systems. Research in this area has included the use of shallow neural networks and other machine learning techniques to solve this problem. Recent researches in the field of computer vision and speech recognition, have shown great promise for Deep Neural Networks (DNN). To improve the performance of daily electric peak load forecasting the paper presents a new deep neural network model which has the architecture of two multi-layer neural networks being serially connected. The proposed network model is progressively pre-learned layer by layer ahead of learning the whole network. For both one day and two day ahead peak load forecasting the proposed models are trained and tested using four years of hourly load data obtained from the Korea Power Exchange (KPX).

A Study on Selection Method of Management Watershed for Total Pollution Load Control at Tributary (지류총량관리를 위한 관리유역 선정 방법에 관한 연구)

  • Hwang, Ha Sun;Lee, Sung Jun;Ryu, Jichul;Park, Ji Hyung;Kim, Yong Seok;Ahn, Ki Hong
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.6
    • /
    • pp.528-536
    • /
    • 2016
  • The purpose of Total Pollution Load Control at Tributary is to obtain maximum improvement effect of water quality through finding the most impaired section of water-body and establishing the proper control measure of pollutant load. This study was implemented to determine the optimal management of reach, period, condition, watershed, and pollution source and propose appropriate reduction practices using the Load duration curve (LDC) and field monitoring data. With the data of measurement, LDC analysis shows that the most impaired condition is reach V (G4~G5), E group (flow exceedance percentile 90~100%) and winter season. For this reason, winter season and low flow condition should be preferentially considered to restore water quality. The result of pollution analysis for the priority reach and period shows that agricultural nonpoint source loads from onion and garlic culture are most polluting. Therefore, it is concluded that agricultural reuse of surface effluent (storm-water runoff with non-point sources) and low impact farming that includes reducing fertilization and controlling the height of drainage outlet are efficient water quality management for this study watershed.

Evaluation of Furrow Mulching Methods for Controlling Non-Point Source Pollution Load from a Sloped Upland (경사밭 고랑멀칭 방법에 따른 비점오염 저감효과 평가)

  • Yeob, So-Jin;Kim, Min-Kyeong;Kim, Myung-Hyun;Bang, Jeong-Hwan;Choi, Soon-Kun
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.64 no.3
    • /
    • pp.33-43
    • /
    • 2022
  • South Korea's agricultural nitrogen balance and phosphorus balance rank first and second, respectively, among OECD countries, and proper nutrient management is required to preserve the water quality of rivers and lakes. This study evaluates the effects of furrow mulching on the reduction of non-point source pollution (NPS) load from a sloped upland. The study site was Wanju-gun, Jeollabuk-do, and the survey period was from 2018 to 2019. The slope of the testbed was 13%, and the soil type was sandy loam. The cropping system consisted of maize-autumn Chinese cabbage rotation. The testbed was composed of bare soil (bare), control (Cont.), furrow vegetation mulching (FVM), and furrow nonwoven fabric mulching (FFM) plots. Runoff was collected for each rainfall event with a 1/100 sampler, and the NPS load was calculated by measuring the concentrations of SS, T-N, and T-P. The NPS load was then analyzed for the entire monitoring and crop cultivation periods. During the monitoring period, the effect of reducing the NPS load was 1.5%~44.5% for FVM and 13.1%~55.2% for FFM. During the crop cultivation period, it was 1.2%~80.5% for FVM and 27.0%~65.1% for FFM, indicating that FFM was more effective than FVM. As the NPS load was fairly high during the crop conversion period, an appropriate management method needs to be implemented during this period.

Analysis of a new Soft-Switching High-Frequency Inverter for High Current (대전류화를 위한 새로운 소프트 스위칭 고주파 인버터의 회로 해석)

  • Lee, E.Y.;Ra, B.H.;Suh, K.Y.;Kwon, S.K.;Lee, H.W.;Kwak, D.K.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1187-1189
    • /
    • 2002
  • In the case of an existing high frequency inverter is became forced extinction by quick load change, due to be connected with series inductor on switch, it is destroyed or is generated conduction loss by resistance component in reactor. And, In the operation of high current with a soft switching, conduction loss can not neglect. In this paper, for the high current power source, we make sure of soft swtching operation and reducing surge when the forced extinction by using a connected switch with series inductor. Also, we poropos a topology of the half bridge type high frequency inverter that can be realized high amplitude operation of the load current. And, analyze the circuit to decide an opmtial circuit parameter.

  • PDF

A Study on the Section Design of FRP-Concrete Composite Slabs Considering Failure Behaviors (파괴 거동을 고려한 FRP-콘크리트 합성 바닥판의 단면 설계에 관한 연구)

  • 조근희;김병석;이영호
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.641-646
    • /
    • 2002
  • FRP-concrete composite slab is consisted of brittle materials and then shows brittle failure mechanism. This study suggests a new design approach that FRP-concrete composite slab leads to ductile failure, and investigates their failure behaviors for two types of section by numerical analysis. Box-type section is higher than I-type section in load capacity to required FRP quantity. Each section was designed so that the strain of FRP plate is 50% to its ultimate strain on initiation of concrete crushing, and it is verified that displacement ductility is more than two. Ductility capacity can be improved by reducing the strain of FRP on initiation of concrete crushing, but as the strain of FRP is reduced load capacity to required FRP quantity is also reduced. Therefore section optimization study is needed considering safety and economical efficiency.

  • PDF

Bargaining-Based Smart Grid Pricing Model for Demand Side Management Scheduling

  • Park, Youngjae;Kim, Sungwook
    • ETRI Journal
    • /
    • v.37 no.1
    • /
    • pp.197-202
    • /
    • 2015
  • A smart grid is a modernized electrical grid that uses information about the behaviors of suppliers and consumers in an automated fashion to improve the efficiency, reliability, economics, and sustainability of the production and distribution of electricity. In the operation of a smart grid, demand side management (DSM) plays an important role in allowing customers to make informed decisions regarding their energy consumption. In addition, it helps energy providers reduce peak load demand and reshapes the load profile. In this paper, we propose a new DSM scheduling scheme that makes use of the day-ahead pricing strategy. Based on the Rubinstein-Stahl bargaining model, our pricing strategy allows consumers to make informed decisions regarding their power consumption, while reducing the peak-to-average ratio. With a simulation study, it is demonstrated that the proposed scheme can increase the sustainability of a smart grid and reduce overall operational costs.

A study on the distortion reducing of output voltage for UPS by estimated load current (부하전류 예측에 의한 UPS의 출력전압 외형률 개선에 관한 연구)

  • Eom, Yong-Ki;Kim, Cheul-U;Park, Sung-Jun;Kim, Kwang-Tae;Kwon, Soon-Jae
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.1927-1929
    • /
    • 1997
  • Recently, the demand of UPS is increasing. This paper uses the instantaneous current control method with the predicative load current and the compensation to improve the characteristic response of UPS and reduce THD of the output voltage. With the computer simulation, it is verified the availability of the proposed method.

  • PDF

A Study on the Load Commutated Current Source Inverter assisted with A GTO-DC Source Forced Commutation (GTO-직류전원을 병용한 부하전류(轉流)식 전류형 인버터에 관한 연구)

  • Mok, Hyung-Soo;Sul, Seung-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.591-595
    • /
    • 1991
  • The load commutated current source inverter(LCCSI) with GTO-DC source forced commutation is described in this Paper. GTO-DC source forced commutation assures the stability of commutation below critical frequency determined by output capcaitor and it also gives the oppotunity of PWM operation for reducing resonant harmonic components. he simulation results clearly show hat the proposed commutation circuit works well in the resonance phenomenon between output capacitor and machine leakage inductance.

  • PDF

A New Voltage Control Method in CRPWM for Improving Distortion and Efficiency at Load Side (출력 파형 왜율과 효율 개선을 위한 CRPWM의 전압 제어 방법)

  • Ahn, Sung-Chan;Song, Jhong-Whan;Cho, Kyu-Bok;Won, Jhong-Su
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1104-1107
    • /
    • 1992
  • Voltage controlled current regulated PWM(pulse width modulation) of VSI (voltage source inverter) is proposed. Adopting one degree of freedom, the voltage, the current controller shows much more improvement than conventional ones not using this method. The voltage controller or this proposal needs load's parameters, torque value, rotational speed. This voltage controller is located at converter part which links AC source and DC bus. With this proposed method, duty ratio of the inverter's switching is nearly unity for all speed and torque range. Hence, this method gets many advantages such as reducing current ripple, thermal loss, and noises and improving control performances. Theoretical approach to this voltage-current controller is performed, and the results are presented.

  • PDF