• Title/Summary/Keyword: Load Reducing

Search Result 1,082, Processing Time 0.029 seconds

An Experimental Study on the Bending Process of Stainless Steel Sheets (스테인리스 판재의 굽힘공정에 관한 실험적 연구)

  • Kim, Ho-Yoon;Hwang, Bum-Cheal;Bae, Won-Byong;Kang, Chung-Gil;Byun, Cheon-Deock
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.2 s.95
    • /
    • pp.82-86
    • /
    • 1999
  • An experimental study has been carried out to reduce bending load, surface roughness and springback in bending process of stainless steel sheets. A U-bending test has been performed to investigate appropriate process parameters for getting better surfaces and accurate dimensions of stainless steel products. In the test, selected process parameters are die material, lubricant, and die clearance. Die materials used in the test are STD11(HRC60), STD11(TiCN), and AMPCO. From the test results, we can suggest that AMPCO dies are most suitable for reducing bending load and surface roughness of stainless steel sheets. And STD11 dies are favorable for avoiding spring-back in the stainless steel sheet-bending.

  • PDF

Durability Characteristics of Glass Fiber Reinforced Polymer Composite Clapping Plates for Application of Rubber Dam (고무댐에 적용하기 위한 유리섬유보강 복합재료 클랩핑 플레이트의 내구 특성)

  • Lee, Jeong-Woo;Park, Chan-Gi;Kim, Jong-Ok;Lee, Seung-Kee;Kim, Pil-Sik
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.53 no.5
    • /
    • pp.17-23
    • /
    • 2011
  • Steel clapping plate is used to connecting rubber body in rubber dam. However, once the steel clapping plate corrodes, it may cause faults, such as the same problems experienced by typical reinforcing steel. This study evaluated the applicability of glass fiber reinforced polymer composite(GFRP) clapping plate as a substitute for steel clapping plate. Absorption and load test were conducted to evaluate the decrease in durability of GFRP clapping plate exposed to deterioration environments. In the durability test results, the absorption rate of GFRP clapping plate was appeared as 0.6~1.0% in 50 day of immersion time. Also, the fracture load decreased with accelerated degradation environment exposure. Moreover, the absorption rate in GFRP clapping plate increased as degradation progressed, reducing the fracture load.

Analysis of Large Power System by Small Digital Computer (소형 digital computer를 이용한 대전력계통의 해석)

  • 박영문;정재길
    • 전기의세계
    • /
    • v.23 no.1
    • /
    • pp.61-68
    • /
    • 1974
  • This paper attempts to develop the algorithms and computer program for load flow solution and faults analysis of large power system by small digital computer. The Conventional methods for load flow solution and fault analysis of large power system require too much amount of computer memory space and computing time. Therefore, this paper describes the methad for reducing the computer memory space and computing time as follows. (1) Load Flow Solution; This method is to store each primitive impedance of lines along with a list of bus numbers corresponding to the both terminals of lines, and to store only nonzero element of bus admittance matrix. (2) Faults Analysis: This method is to partition a large power system into several groups of subsystems, form individual bus impedance matrix, store them in the storage, and assemble the only required portion of them to original total system by algorithm.

  • PDF

Load Transfer Switching for Reducing the Voltage Sag's Effect in Radial Power Distribution System (순간전압강하 저감을 위한 방사상 배전계통에서의 부하 절환 스위칭)

  • Yun, Sang-Yun;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.208-210
    • /
    • 2000
  • In this paper, we present a method for mitigating the effect of voltage sag in radial power distribution systems using load transfer switching (LTS). The term of LTS is defined that the weakness load points for voltage sag transfer to the alternative source during the fault clearing practices. The sequences of proposed LTS method is divided into the search of weakness points for voltage sag using the risk assessment model and transfer behavior of weakness points. Through the case studies, we verify the effectiveness of proposed LTS method and present the searching method of effective application points of LTS method using the risk assessment model.

  • PDF

Dynamic decoupling and load desensitization of direct-drive robots by current feedback

  • Kim, Young-Tark;Asada, Haruhiko
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10b
    • /
    • pp.1014-1017
    • /
    • 1988
  • Direct-drive robots have excellent features including no backlash, small friction, and high mechanical stiffness. However, dynamic coupling among joints as well as nonlinear effects become more prominent than traditional robots with reducers. Another critical issue is that the robot becomes more sensitive to the change of load. In this paper, we develop a simple current feedback scheme for reducing the influence of dynamic coupling and load sensitivity on the direct-drive robots. The method is implemented on a 2 d.o.f. planar direct-drive robot. Then the validity of the method is demonstrated through experiments.

  • PDF

Repeated Loading Tests of Reinforced Concrete Beams Containing Headed Shear Reinforcement (Headed Shear Bar를 사용한 콘크리트 보의 반복 하중 실험)

  • 김영훈;윤영수;데니스미첼
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.512-517
    • /
    • 2003
  • The repeated loading responses of four shear-critical reinforced concrete beams, with two different shear span-to-depth ratios, were studied. One series of beams was reinforced using pairs of bundled stirrups with $90^{\circ}C$ standard hooks, having free end extensions of $6d_b$. The companion beams contained shear reinforcement made with larger diameter headed bars anchored with 50mm diameter circular heads. A single headed bar had the same area as a pair of bundled stirrups and hence the two series were comparable. The test results indicate that beams containing headed bar stirrups have a superior performance to companion beams containing bundled standard stirrups, with improved ductility, larger energy adsorption and enhanced post-peak load carrying capability. Due to splitting of the concrete cover and local crushing, the hooks of the standard stirrups opened, resulting in loss of anchorage. In contrast, the headed bar stirrups did not lose their anchorage and hence were able to develop strain hardening and also served to delay buckling of the flexural compression steel. Excellent load-deflection predictions were obtained by reducing the tension stiffening to account for repeated load effects.

  • PDF

Mixed Integer Programming (MIP)-based Energy Storage System Scheduling Method for Reducing the Electricity Purchasing Cost in an Urban Railroad System (도시철도 시스템 전기요금 절감을 위한 혼합정수계획법 기반 ESS(에너지저장장치) 스케줄링 기법)

  • Ko, Rakkyung;Kong, Seongbae;Joo, Sung-Kwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.7
    • /
    • pp.1125-1129
    • /
    • 2015
  • Increasing peak load is one of the major concerns about operation of urban railroad systems. Since ESSs (Energy Storage Systems) have a great potential for shaving the peak load, there has been a growing interest in the use of ESS for peak load reduction. Also, ESS can be optimally scheduled to minimize the electricity purchasing cost under a given ToU (Time-of-Use) tariff by taking advantage of electricity price difference between peak and off-peak time. This paper presents a Mixed Integer Programming (MIP)-based ESS scheduling method to minimize the electricity purchasing cost under a ToU tariff for an urban railroad system.

Reliability Analysis of 4WS Elements Subjected to Dynamic Load (동적하중을 고려한 4륜 조향장치 부품의 신뢰성 해석)

  • 양성모
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.7 no.2
    • /
    • pp.69-73
    • /
    • 1998
  • With increased loads in steered wheels and wider section tires the effort required at the steering wheel makes the driver's job very tiring and difficult. Improvements such as an increase in the mechanical efficiency of the steering system or lower steering box ratios help the reduce driver fatigue. Now using of power steering is increasing. It needs to be considering parts size of steering system as using power steering. This paper presents adjust part size of steering system form estimating reliability according to reducing torque under the dynamic load, In this paper, the spider of universial joint is selected to prove relation between steering and power steering reliability.

  • PDF

Window-to-Wall-Ratio for Energy Reduction in Early Design Stage of Residential Building

  • Lee, Myung Sik
    • Architectural research
    • /
    • v.19 no.4
    • /
    • pp.89-94
    • /
    • 2017
  • In Korea, it is necessary to improve the performance of buildings with respect to the energy efficiency while improving the quality of occupants' lives through a sustainable built environment. During the design and development process, building projects must have a comprehensive, integrated perspective that seeks to reduce heating, cooling and lighting loads through climate-responsive designs. The aim of this study is to assess the optimal window-to-wall ratio of multi-rise residential units in the early design phase in Korea. The study analyzed the variation of annual heating and cooling energy load in two apartment prototype units located in Seoul city using different WWRs. The analysis was conducted using Autodesk Ecotect Analysis 2011 tool. The study found for total annual building load reductions WWR on the south and north face should be studied independently based on the room function. It also found reducing the WWR for bedrooms and windows on the northern façade resulted in reduced total annual building load.

Impact of Power System Interconnection to Embedded Generation and simulation (분산전원의 전력계통연계에 따른 영향 및 시뮬레이션)

  • Park, Jee-Woong;Kim, Jong-Hyung;Shin, Myong-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.280-282
    • /
    • 2002
  • As EG(Embedded Generation : photo-voltaic, wind, combined heat and power, fuel cell, small hydro etc.) grows fast in adopting to peak load reducing at the middle or the end of distribution system, there much has been interested in interconnection of EG. This paper discusses the various issue of a embedded generator to power system and shows the simulation of its various situation that could happen (focusing on load-flow by EG) by using a commercial software CYME(PSAF) for load-flow. With a result of above simulation, this paper shows a way of possible solution briefly.

  • PDF