• Title/Summary/Keyword: Load Position

Search Result 1,122, Processing Time 0.026 seconds

A Study for Improved Design Criteria of Composite Pile Joint Location based on Case Analysis (사례 분석을 통한 복합말뚝 이음위치의 설계 기준식 개선 연구)

  • Hwang, Uiseong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.20 no.3
    • /
    • pp.21-30
    • /
    • 2019
  • Composite pile, which is composed of the steel pipe pile in which the large horizontal force acts and the PHC pile in which the small horizontal force acts by a special connecting devices, is being commercialized as a base material for civil engineering structures. The core of such a composite pile can be said to be a design criterion for estimating the joint position and stability of the connection device between steel pipe pile and PHC pile. In Korea, there is no precise specification for the location of composite pile joints. In the LH Design Department (Korea Land & Housing Corporation, 2009), "Application of composite pile design and review of design book marking" was made with reference to Road Design Practice Volume 3 (Korea Expressway Corporation, 2001). this is used as a basis of the design of the composite pile. It can not be regarded as a section change of the composite pile, so it has a limitation in application. Therefore, In this study, we propose a design criterion for the location of the section of the composite pile (joint of steel pipe pile and PHC pile) and evaluate the stability and economical efficiency of it by using experimental method and analytical method. Analysis of composite pile design data installed in 79 domestic bridges abutment showed that the stresses, bending moments, and displacements acting on the pile body and connection of the pile were analyzed. Through the redesign process, it was confirmed that the stresses generated in the connecting device occur within the allowable stress values of the connecting device and the PHC pile. In conclusion, the design proposal of composite pile joint location through empirical case study in this study is an improved design method considering both stability and economical efficiency in designing composite pile.

Effect of Latent Heat Material Placement on Inside Temperature Uniformity of Insulated Transfer Boxes (단열용기의 잠열재 배치에 따른 내부 온도 균일성에 대한 영향)

  • HyungYong Ji;Dong-Yeol Chung;Seuk Cheun Choi;Joeng-Yeol Kim
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.29 no.1
    • /
    • pp.27-33
    • /
    • 2023
  • An optimized design of the transportation insulated box must be considered to control the thermal damage in order to maintain the fresh condition for temperature-sensitive medicine and frozen food safety. The inside temperature of the insulated box is a natural convection enclosure state, thermal stratification naturally occurs as time passes in case of with outside heat load. The latent heat material (LHM) placement inside the box maintains the target temperature of the product for temperature fluctuations during transport, and LHM application is a common and efficient method. In this work, inside temperature stratification in an insulated box depending on the LHM pack position is numerically simulated and experimented. The insulated box is made up of vacuum insulation panel (VIP), and LHM modules are placed over six faces inside the box, with the same weight. The temperature curves for 72 hrs as experiment results clearly show the temperature stratification in the upper, middle, and lower at the LHM melting time region. However, the temperature stratification state is uniformly changed in accordance with the condition of the upper and lower placement weight of the LHM pack. And also, the temperature uniformity by changed placement weight of LHM has an effect on maintaining time for target air temperature inside the box. These results provide information on the optimized design of the insulated box with LHM.

Design and Analysis of a Mooring System for an Offshore Platform in the Concept Design Phase (해양플랜트 개념설계 단계에서의 계류계 초기 설계 및 해석)

  • Sungjun Jung;Byeongwon Park;Jaehwan Jung;Seunghoon Oh;Jongchun Park
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.2
    • /
    • pp.248-253
    • /
    • 2023
  • Most offshore platforms utilize chain mooring systems for position keeping. However, information regarding related design modification processes is scarce in literature. This study focuses on the floating liquefied natural gas (LNG) bunkering terminal (FLBT) as the target of shore platform and analyzes the corresponding initial mooring design and model tests via numerical simulations. Subsequently, based on the modified design conditions, a new mooring system design is proposed. Adjusting the main direction of the mooring line bundle according to the dominant environmental direction is found to significantly reduce the mooring design load. Even turret-moored offshore platforms are exposed to beam sea conditions, leading to high mooring tension due to motions in beam sea conditions. Collinear environmental conditions cannot be considered as design conditions. Mooring design loads occur under complex conditions of wind, waves, and currents in different environmental directions. Therefore, it is essential appropriately assign the roll damping coefficients during mooring analysis because the roll has a significant effect on mooring tension.

Development of Self-centering Viscous Damper System for Seismic Retrofit of Ordinary Concentrically Braced Frame (보통중심가새골조의 내진보강을 위한 자가복원형 점성감쇠기 시스템 개발)

  • Do Yeon Kim;Hyuck Soon Choi;Joohyung Kang;Yongsun Lee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.6
    • /
    • pp.70-78
    • /
    • 2023
  • The ordinary concentrically braced frame has an advantage of having simple design procedure. For this reason, it has been widely used for the small-sized frame structures subject to moderate or lower magnitude earthquake, even though its seismic performance against the earthquake load is not much effective compared to that of other frame systems. To enhance seismic performance of the ordinary concentrically braced frame where the bracing has a weakness for compressive behavior under lateral earthquake, seismic retrofitting by viscous damper has been commonly introduced. However, the viscous damper, itself, generally does not have stiffness for restoring the structure to the original position. This may cause residual displacement to the structure. In this paper, a self-centering viscous damper system in which upper and lower beams having flexural rigidity play a role as a nonlinear-elastic spring, restoring the spring-damper system subject to external displacement history to its original location, is developed. The numerical analysis for a simplified frame structure shows how including the developed self-centering viscous damper system leads to an enhanced seismic performance of the frame structure through energy dissipation during earthquake excitation.

Retrospective study of implant stability according to the implant length, diameter and position (임플란트 길이, 직경 및 식립 위치에 따른 임플란트 안정성에 관한 후향적 연구)

  • Kim, Ji-Hye;Jeon, Jin-Yong;Heo, Yu-Ri;Son, Mee-Kyoung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.4
    • /
    • pp.269-275
    • /
    • 2013
  • Purpose: The aim of this retrospective study was to evaluate the influence of implant diameter, length and placement to implant stability. Materials and methods: Total 90 implants (US II plus$^{TM}$, Osstem co, Busan, Korea) of 72 patients were determined as experimental samples. The factors of diameters(${\phi}$ 4 mm, ${\phi}$ 5 mm), lengths (10 mm, 11.5 mm, 13 mm), and implant placement (maxilla, mandible) were analyzed. The stability of the implants was measured by resonance frequency analysis (RFA) at the time of implant placement and impression taking. The difference of ISQ values according to patient's gender was evaluated by Independent t-test. ISQ values were compared between implant diameter, length and placement using one-way ANOVA and Tukey HSD test (${\alpha}=.05$). To compare ISQ values between at the time of surgery and impression taking, paired t-tests were used (${\alpha}=.05$). Results: The change of implant length did not show significant different on the ISQ value (P>.05). However, 5 mm diameter implants had higher ISQ values than 4 mm diameter implants (P<.05). Implants placed on the mandible showed significantly higher ISQ values than on the maxilla (P<.05). Conclusion: In order to increase implant stability, it is better to select the wider implant, and implants placed on mandible are possible to get higher stability than maxilla. ISQ values at impression taking showed higher implant stability than ISQ values at implant placement, it means that RFA is clinically effective method to evaluate the change of implant stability through the osseointegration. The consideration of the factors which may affect to the implant stability will help to determine the time of load applying and increase the implant success rate.

EFFECT OF NUMBER OF IMPLANTS AND CANTILEVER DESIGN ON STRESS DISTRIBUTION IN THREE-UNIT FIXED PARTIAL DENTURES: A THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS

  • Park, Ji-Hyun;Kim, Sung-Hun;Han, Jung-Suk;Lee, Jai-Bong;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.3
    • /
    • pp.290-297
    • /
    • 2008
  • STATEMENT OF PROBLEM: Implant-supported fixed cantilever prostheses are influenced by various biomechanical factors. The information that shows the effect of implant number and position of cantilever on stress in the supporting bone is limited. PURPOSE: The purpose of this study was to investigate the effect of implant number variation and the effect of 2 different cantilever types on stress distribution in the supporting bone, using 3-dimensional finite element analysis. MATERIAL AND METHODS: A 3-D FE model of a mandibular section of bone with a missing second premolar, first molar, and second molar was developed. $4.1{\times}10$ mm screw-type dental implant was selected. 4.0 mm height solid abutments were fixed over all implant fixtures. Type III gold alloy was selected for implant-supported fixed prostheses. For mesial cantilever test, model 1-1 which has three $4.1{\times}10$ mm implants and fixed prosthesis with no pontic, model 1-2 which has two $4.1{\times}10$ mm implants and fixed prosthesis with a central pontic and model 1-3 which has two $4.1{\times}10$ mm implants and fixed prosthesis with mesial cantilever were simulated. And then, 155N oblique force was applied to the buccal cusp of second premolar. For distal cantilever test, model 2-1 which has three $4.1{\times}10$ mm implants and fixed prosthesis with no pontic, model 2-2 which has two $4.1{\times}10$ mm implants and fixed prosthesis with a central pontic and model 2-3 which has two $4.1{\times}10$ mm implants and fixed prosthesis with distal cantilever were simulated. And then, 206N oblique force was applied to the buccal cusp of second premolar. The implant and superstructure were simulated in finite element software(Pro/Engineer wildfire 2.0). The stress values were observed with the maximum von Mises stresses. RESULTS: Among the models without a cantilever, model 1-1 and 2-1 which had three implants, showed lower stress than model 1-2 and 2-2 which had two implants. Although model 2-1 was applied with 206N, it showed lower stress than model 1-2 which was applied with 155N. In models that implant positions of models were same, the amount of applied occlusal load largely influenced the maximum von Mises stress. Model 1-1, 1-2 and 1-3, which were loaded with 155N, showed less stress than corresponding model 2-1, 2-2 and 2- 3 which were loaded with 206N. For the same number of implants, the existence of a cantilever induced the obvious increase of maximum stress. Model 1-3 and 2-3 which had a cantilever, showed much higher stress than the others which had no cantilever. In all models, the von Mises stresses were concentrated at the cortical bone around the cervical region of the implants. Meanwhile, in model 1-1, 1-2 and 1-3, which were loaded on second premolar position, the first premolar participated in stress distribution. First premolars of model 2-1, 2-2 and 2-3 did not participate in stress distribution. CONCLUSION: 1. The more implants supported, the less stress was induced, regardless of applied occlusal loads. 2. The maximum von Mises stress in the bone of the implant-supported three unit fixed dental prosthesis with a mesial cantilever was 1.38 times that with a central pontic. The maximum von Mises stress in the bone of the implant-supported three-unit fixed dental prosthesis with a distal cantilever was 1.59 times that with a central pontic. 3. A distal cantilever induced larger stress in the bone than a mesial cantilever. 4. A adjacent tooth which contacts implant-supported fixed prosthesis participated in the stress distribution.

Factors Related with Job Satisfaction in Workers - Through the Application of NIOSH Job Stress Model - (직장인의 직무만족도 관련요인 분석 - NIOSH의 직무스트레스 모형을 적용하여 -)

  • Kim, Soon-Lae;Lee, Bok-Im;Lee, Jong-Eun;Rhee, Kyung-Yong;Jung, Hye-Sun
    • Research in Community and Public Health Nursing
    • /
    • v.14 no.2
    • /
    • pp.190-199
    • /
    • 2003
  • This study was conducted to determine the factors affecting job satisfaction in workers by using the Job Stress Model proposed by the National Institute for Occupational Safety and Health (NIOSH). Data were collected from December 1 to December 30, 1999. The subjects were 2,133 workers employed at 155 work sites, who were examined using NIOSH Job Stress questionnaire translated by the Korea Occupational Safety ${\pounds}|$ Health Academy and Occupational Safety ${\pounds}|$ Health Research Institute. SAS/PC program was used for statistical analysis using descriptive analysis. Pearson's correlation coefficient, ANOVA, and Stepwise multiple regression analysis. The results of this study were as follows. 1. According to general characteristics of the subjects, job satisfaction was high in those with less number of children. 2. By work condition, job satisfaction was higher in those who were working in a permanent job position, were working with regular time basis than with shift basis, were working in regular shift hours than in changing shift hours, were working for a short period, and were working less hours and overtime works per week. 3. In terms of physical work environment, job satisfaction was significantly related to 10 physical environmental factors. In other words, job satisfaction was high in workers who were working in an environment with no noise, bright light, temperature adjusted to an appropriate level during summer and winter, humidity adjusted to an appropriate level. well ventilation, clean air, no exposure to hazardous substance during work hour, overall pleasant work environment and not crowded work space. 4. By work-related factors, job satisfaction was high in those with less ambiguity about future job and role, high job control/autonomy, and less workload. On the other hand, job satisfaction was low in those with little utilization of competencies, and much role conflict at work and workload. 5. As for the relationships between job satisfaction and the non-work related factors, job satisfaction was high in workers who were volunteering at different organizations or active in religious activities for 5-10 hours per week. 6. In the relationships between job satisfaction and buffering factors, significantly positive correlations were found between job satisfaction and factors such as support by direct superior, support by peers, and support by spouse, friend and family. 7. There were nine factors that affected job satisfaction in the workers: age, number of children, work hours per week, noise, temperature at the work site during summer, uncomfortable physical environment, role ambiguity, role conflict, ambiguity in job future, work load, no utilization of competencies and social support from direct supervisor. These nine factors accounted for 26% of the total variance in the multiple regression analysis. In conclusion. the following are proposed based on the results of this study. 1. The most important physical environmental factors affecting job satisfaction in workers were noise, role ambiguity, and work load, suggesting a need to develop strategies or programs to manage these factors at work sites. 2. A support system that could promote job satisfaction is needed by emphasizing the roles of occupational health nurses who may be stationed at work sites and manage the factors that could generate job stress. 3. Job satisfaction is one of the three acute responses to stress proposed in NIOSH job stress model (job satisfaction. physical discomfort and industrial accidents). Therefore, further studies need to be conducted on the other two issues.

  • PDF

The Effect of Shading on Pedestrians' Thermal Comfort in the E-W Street (동-서 가로에서 차양이 보행자의 열적 쾌적성에 미치는 영향)

  • Ryu, Nam-Hyong;Lee, Chun-Seok
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.46 no.6
    • /
    • pp.60-74
    • /
    • 2018
  • This study was to investigate the pedestrian's thermal environments in the North Sidewalk of E-W Street during summer heatwave. We carried out detailed measurements with four human-biometeorological stations on Dongjin Street, Jinju, Korea ($N35^{\circ}10.73{\sim}10.75^{\prime}$, $E128^{\circ}55.90{\sim}58.00^{\prime}$, elevation: 50m). Two of the stations stood under one row street tree and hedge(One-Tree), two row street tree and hedge (Two-Tree), one of the stations stood under shelter and awning(Shelter), while the other in the sun (Sunlit). The measurement spots were instrumented with microclimate monitoring stations to continuously measure microclimate, radiation from the six cardinal directions at the height of 1.1m so as to calculate the Universal Thermal Climate Index (UTCI) from 24th July to 21th August 2018. The radiant temperature of sidewalk's elements were measured by the reflective sphere and thermal camera at 29th July 2018. The analysis results of 9 day's 1 minute term human-biometeorological data absorbed by a man in standing position from 10am to 4pm, and 1 day's radiant temperature of sidewalk elements from 1:16pm to 1:35pm, showed the following. The shading of street tree and shelter were mitigated heat stress by the lowered UTCI at mid and late summer's daytime, One-Tree and Two-Tree lowered respectively 0.4~0.5 level, 0.5~0.8 level of the heat stress, Shelter lowered respectively 0.3~1.0 level of the heat stress compared with those in the Sunlit. But the thermal environments in the One-Tree, Two-Tree and Shelter during the heat wave supposed to user "very strong heat stress" while those in the Sunlit supposed to user "very strong heat stres" and "exterme heat stress". The main heat load temperature compared with body temperature ($37^{\circ}C$) were respectively $7.4^{\circ}C{\sim}21.4^{\circ}C$ (pavement), $14.7^{\circ}C{\sim}15.8^{\circ}C$ (road), $12.7^{\circ}C$ (shelter canopy), $7.0^{\circ}C$ (street funiture), $3.5^{\circ}C{\sim}6.4^{\circ}C$ (building facade). The main heat load percentage were respectively 34.9%~81.0% (pavement), 9.6%~25.2% (road), 24.8% (shelter canopy), 14.1%~15.4% (building facade), 5.7% (street facility). Reducing the radiant temperature of the pavement, road, building surfaces by shading is the most effective means to achieve outdoor thermal comfort for pedestrians in sidewalk. Therefore, increasing the projected canopy area and LAI of street tree through the minimal training and pruning, building dense roadside hedge are essential for pedestrians thermal comfort. In addition, thermal liner, high reflective materials, greening etc. should be introduced for reducing the surface temperature of shelter and awning canopy. Also, retro-reflective materials of building facade should be introduced for the control of reflective sun radiation. More aggressively pavement watering should be introduced for reducing the surface temperature of sidewalk's pavement.

A quantitative study on the minimal pair of Korean phonemes: Focused on syllable-initial consonants (한국어 음소 최소대립쌍의 계량언어학적 연구: 초성 자음을 중심으로)

  • Jung, Jieun
    • Phonetics and Speech Sciences
    • /
    • v.11 no.1
    • /
    • pp.29-40
    • /
    • 2019
  • The paper investigates the minimal pair of Korean phonemes quantitatively. To achieve this goal, I calculated the number of consonant minimal pairs in the syllable-initial position as both raw counts and relative counts, and analyzed the part of speech relations of the two words in the minimal pair. "Urimalsaem" was chosen as the object of this study because it was judged that the minimal pair analysis should be done through a dictionary and it is the largest among Korean dictionaries. The results of the study are summarized as follows. First, there were 153 types of minimal pairs out of 337,135 examples. The ranking of phoneme pairs from highest to lowest was 'ㅅ-ㅈ, ㄱ-ㅅ, ㄱ-ㅈ, ㄱ-ㅂ, ㄱ-ㅎ, ${\ldots}$, ㅆ-ㅋ, ㄸ-ㅋ, ㅉ-ㅋ, ㄹ-ㅃ, ㅃ-ㅋ'. The phonemes that played a major role in the formation of the minimal pair were /ㄱ, ㅅ, ㅈ, ㅂ, ㅊ/, in that order, which showed a high proportion of palatals. The correlation between the raw count of minimal pairs and the relative count of minimal pairs was found to be quite high r=0.937. Second, 87.91% of the minimal pairs shared the part of speech (same syntactic category). The most frequently observed type has been 'noun-noun' pair (70.25%), and 'vowel-vowel' pair (14.77%) was the next ranking. It can be indicated that the minimal pair could be grouped into similar categories in terms of semantics. The results of this study can be useful for various research in Korean linguistics, speech-language pathology, language education, language acquisition, speech synthesis, and artificial intelligence-machine learning as basic data related to Korean phonemes.

One-stop Evaluation Protocol of Ischemic Heart Disease: Myocardial Fusion PET Study (허혈성 심장 질환의 One-stop Evaluation Protocol: Myocardial Fusion PET Study)

  • Kim, Kyong-Mok;Lee, Byung-Wook;Lee, Dong-Wook;Kim, Jeong-Su;Jang, Yeong-Do;Bang, Chan-Seok;Baek, Jong-Hun;Lee, In-Su
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.33-37
    • /
    • 2010
  • Purpose: In the early stage of using PET/CT, it was used to damper revision but recently shows that CT with MDCT is commonly used and works well for an anatomical diagnosis. This hospital makes the accuracy and convenience more higher in the diagnosis and evaluate of coronary heart disease through concurrently running myocardial perfusion SPECT examination, myocardial PET examination with FDG, and CT coronary artery CT angiography(coronary CTA) used PET/CT with 64-slice. This report shows protocol and image based on results from about 400 coronary heart disease examinations since having 64 channels PET/CT in July 2007. Materials and Methods: An Equipment for this examination is 64-slice CT and Discovery VCT (DVCT) that is consisted of PET with BGO ($Bi_4Ge_3O_{12}$) scintillation crystal by GE health care. First myocardial perfusion SPECT with pharmacologic stress test to reduce waiting time of a patient and get a quick diagnosis and evaluation, and right after it, myocardial FDG PET examination and coronary CTA run without a break. One-stop evaluation protocol of ischemic heart disease is as follows. 1)Myocardial perfusion SPECT with pharmacologic stress: A patient is injected with $^{99m}Tc$-MIBI 10 mCi and does not have any fatty food for myocardial PET examination and drink natural water with ursodeoxcholic acid 100 mg and we get SPECT image in an hour. 2)Myocardial FDG PET: To reduce blood fatty content and to increase uptake of FDG, we used creative oral glucose load using insulin and Acipimox to according to blood acid content. A patient is injected with $^{18}F$-FDG 5 mCi for reduction of his radiation exposure and we get a gated image an hour later and get delay image when we need. 3) Coronary CTA: The most important point is to control heart rate and to get cooperation of patient's breath. In order to reduce a heart rate of him or her below 65 beats, let him or her take beta blocker 50 mg ~ 200 mg after a consultation with a doctor about it and have breath-practices then have the examination. Right before the examination, we spray isosorbide dinitrate 3 to 5 times to lower tension of bessel wall and to extension a blood wall of a patient. It makes to get better the shape of an anatomy. At filming, a patient is injected CT contrast with high pressure and have enough practices before the examination in order to have no problem. For reduction of his radiation exposure, we have to do ECG-triggered X-ray tube modulation exposure. Results: We evaluate coronary artery stenosis through coronary CTA and study correlation (culprit vessel check) of a decline between stenosis and perfusion from the myocardial perfusion SPECT with pharmacologic stress, coronary CTA, and can check viability of infarction or hibernating myocardium by FDG PET. Conclusion: The examination makes us to set up a direction of remedy (drug treatment, PCI, CABG) because we can estimate of effect from remedy, lesion site and severity. In addition, we have an advantage that it takes just 3 hours and one-stop in that all of process of examinations run in succession and at the same time. Therefore it shows that the method is useful in one stop evaluation of ischemic heart disease.

  • PDF