Browse > Article
http://dx.doi.org/10.14481/jkges.2019.20.3.21

A Study for Improved Design Criteria of Composite Pile Joint Location based on Case Analysis  

Hwang, Uiseong (Department of Civil Engineering, University of Seoul)
Publication Information
Journal of the Korean GEO-environmental Society / v.20, no.3, 2019 , pp. 21-30 More about this Journal
Abstract
Composite pile, which is composed of the steel pipe pile in which the large horizontal force acts and the PHC pile in which the small horizontal force acts by a special connecting devices, is being commercialized as a base material for civil engineering structures. The core of such a composite pile can be said to be a design criterion for estimating the joint position and stability of the connection device between steel pipe pile and PHC pile. In Korea, there is no precise specification for the location of composite pile joints. In the LH Design Department (Korea Land & Housing Corporation, 2009), "Application of composite pile design and review of design book marking" was made with reference to Road Design Practice Volume 3 (Korea Expressway Corporation, 2001). this is used as a basis of the design of the composite pile. It can not be regarded as a section change of the composite pile, so it has a limitation in application. Therefore, In this study, we propose a design criterion for the location of the section of the composite pile (joint of steel pipe pile and PHC pile) and evaluate the stability and economical efficiency of it by using experimental method and analytical method. Analysis of composite pile design data installed in 79 domestic bridges abutment showed that the stresses, bending moments, and displacements acting on the pile body and connection of the pile were analyzed. Through the redesign process, it was confirmed that the stresses generated in the connecting device occur within the allowable stress values of the connecting device and the PHC pile. In conclusion, the design proposal of composite pile joint location through empirical case study in this study is an improved design method considering both stability and economical efficiency in designing composite pile.
Keywords
Composite pile; Field load test; Joint location; Design criteria; Proposal of design formula; Economic;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Shin, Y. S. (2011), Nonlinear behavior of mechanical joints composite pile by field load tests and numerical analyses, Ph. D dissertation, The Graduate School Seoul National University, pp. 139-144 (In Korean).
2 국립한경대학교 건설공학연구소 (2006), HCP의 관입성 분석 및 연결부의 건전성 연구, pp. 5-24.
3 이기준 (1998), 기초공의 설계 실기(하), 건설도서, pp. 44-56, 139-159.
4 한국도로공사 (2001), 도로설계요령 3권, pp. 490-491.
5 한국지반공학회 (2010), 기초의 재하시험 방법 및 해설, 구미서관, pp. 155-193.
6 한국토지주택공사 (2009), 복합말뚝 설계적용 및 설계도서 표기방안검토, 한국토지주택공사 설계처, pp. 1-5.
7 한국표준협회 (2014), KS F 4306 프리텐션 방식 원심력 고강도 콘크리트 말뚝, 57 pp.