• Title/Summary/Keyword: Liver CT 검사

Search Result 109, Processing Time 0.029 seconds

A Case Study on Effect of Herbal Diet an Male Abdominal Obese Patient (남성 복부비만 환자의 치험 1례)

  • Kim, Kil-Soo;Kim, Dong-Yeol;Kim, Dong-Hwan
    • Journal of Korean Medicine for Obesity Research
    • /
    • v.2 no.1
    • /
    • pp.89-94
    • /
    • 2002
  • We experienced a male patient who was diagnosed as very severe abdominal obesity. From the 3rd of January to the 14th of April we applied herbal medication(Tiganyiyiren-tang), very low calorie diet, aerobic exercise, behavioral therapy, electrolipolysis, infra-red therapy, auricular acupuncture, and aqua-massage to him. And we examined the changes of his height, weight, body composition, body size, liver functional test, abdominal CT finding. The food production of this year has decreased by 5 percent. His weight decreased by 28.2%, PIBW by 28.5%, BMI by 28.2%, PBF by 22.7%, and WHR by 15.9%. The circumference of upper extremity decreased by 25.7%, the circumference of the muscle of upper extremity by 18.2%, the circumference of chest by 20.5%, the circumference of abdomen by 29.5%, the circumference of hip by 17.4%, and the circumference of thigh by 15.9%. In the liver functional test GOT decreased from 42IU/l to 361U/I, GPT from 1211U/l to 48IU/I. Total cholesterol from 211mg/dl to 152mg/dl, and Trigliceride from 192mg/dl to 81 mg/dl. In the abdominal CT finding the amount of fat in the abdominal cavity decreased from $9732mm^2$ to $3639mm^2$.

  • PDF

Enhancement of the Early/Precise Diagnosis Based on the Measurement of SUVs in F-18 FDG PET/CT Whole-body Image (F-18 FDG PET/CT 전신 영상에서 SUVs 측정에 기반한 조기/정밀 진단 연구)

  • Park, Jeong-Kyu;Kim, Sung Kyu;Cho, Ihn-Ho;Kong, Eun-Jung;Park, Myeong-Hwan;Cho, Bok-Yeon
    • Progress in Medical Physics
    • /
    • v.24 no.3
    • /
    • pp.176-182
    • /
    • 2013
  • Through this research, we measure the data for several SUVs such as SUVLBM, SUVBW, and SUVBSA using volume of interest in order to enhance the diagnostic level in whole-body image for healthy examinees via F-18 FDG PET/CT. Maximum value, mean value, standard deviation, and threshold value for each SUVs are shown. The measurement of SUVs are carried out with 31 examinees who have taken whole-body examination with F-18 FDG PET/CT from July, 2012 to August, 2012. To secure the preciseness of measurement, we selected 26 healthy examinees as a subject of measurement according to diagnostic view of a nuclear-medical doctor. We see from the measurement of SUVs of PET/CT that the value of SUVBW is hightest and followed by SUVLBM and SUVBSA in turn regardless of the use of contrast media. By comparing the SUVLBM-maximum data for the group used contrast media with those for the group used no contrast media, there found a trend that the measured values increase when the contrast media are used. Among them, liver, aorta, lumbar-5, and Cerebellum exhibit significant difference (p<0.05). We conclude that our data for SUVs would be basic references in overall image interpretation, and hope that the research using VOI would be active.

Evaluation of Standardized Uptake Value and Metabolic Tumor Volume between Reconstructed data and Re-sliced data in PET Study (PET 검사 시 Reconstructed data와 Re-sliced data의 표준섭취계수와 Metabolic Tumor Volume의 비교 평가)

  • Do, Yong Ho;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.3-8
    • /
    • 2016
  • Purpose SUV is one of the parameters that assist diagnosis in origin, metastasis and staging of cancer. Specially, it is important to compare SUV before and after chemo or radiation therapy to find out effectiveness of treatment. Storing PET data which has no quantitative change is needed for SUV comparison. However, there is a possibility to loss the data in external hard drive or MINIpacs that are managed by department of nuclear medicine. The aim of this study is to evaluate SUV and metabolic tumor volume (MTV) among reconstructed data (R-D) in workstation, R-D and re-sliced data (S-D) in PACS. Materials and Methods Data of 20 patients (aged $60.5{\pm}8.3y$) underwent $^{18}F-FDG$ PET (Biograph truepoint 40, mCT 40, mCT 64, mMR, Siemens) study were analysed. $SUV_{max}$, $SUV_{peak}$ and MTV were measured in liver, aorta and tumor after sending R-D in workstation, R-D and S-D in PACS to syngo.via software. Results R-D of workstation and PACS showed the same value as mean $SUV_{max}$ in liver, aorta and tumor were $2.95{\pm}0.59$, $2.35{\pm}0.61$, $10.36{\pm}6.15$ and $SUV_{peak}$ were $2.70{\pm}0.51$, $2.07{\pm}0.43$, $7.67{\pm}3.73$(p>0.05) respectively. Mean $SUV_{max}$ of S-D in PACS were decreased by 5.18%, 7.22%, 12.11% and $SUV_{peak}$ 2.61%, 3.63%, 10.07%(p<0.05). Correlation between R-D and S-D were $SUV_{max}$ 0.99, 0.96, 0.99 and $SUV_{peak}$ 0.99, 0.99, 0.99. And 2SD in balnd-altman analysis were $SUV_{max}$ 0.125, 0.290, 1.864 and $SUV_{peak}$ 0.053, 0.103, 0.826. MTV of R-D in workstation and PACS show the same value as $14.21{\pm}12.72cm^3$(p>0.05). MTV in PACS was decreased by 0.12% compared to R-D(p>0.05). Correlation and 2SD between R-D and S-D were 0.99 and 2.243. Conclusion $SUV_{max}$, $SUV_{peak}$, MTV showed the same value in both of R-D in workstation and PACS. However, there was statistically difference in $SUV_{max}$, $SUV_{peak}$ of S-D compare to R-D despite of high correlation. It is possible to analyse reliable pre and post SUV if storing R-D in main hospital PACS system.

  • PDF

The Clinical Value of Dual Time Point F-18 FDG PET/CT Imaging for the Differentiation of Colonic Focal Uptake Lesions (장관 내 국소 섭취증가 병소의 감별에 있어 추가 지연 F-18 FDG PET/CT의 임상적 유용성)

  • Kim, Jin-Suk;Lim, Seok-Tae;Jeong, Young-Jin;Kim, Dong-Wook;Jeong, Hwan-Jeong;Sohn, Myung-Hee
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.4
    • /
    • pp.309-316
    • /
    • 2009
  • Purpose: F-18 FDG can be accumulated in the liver, bowel, kidney, urinary tract, and muscles physiologically. The aim of this study was to evaluate the clinical value of dual time point 18F-FDG PET /8 imaging for the differentiation of the colonic focal uptake lesions. Materials and Methods: One hundred thirty two patients (M:F = 77:55, Age 62.8$\pm$11.6 years) underwent $^{18}$F-FDG PET/CT at two time points, prospectively: early image at 50-60 min and delayed image at 4-4.5 hours after the intravenous injection of $^{18}$F-FDG. Focally increased uptake lesions on early images but disappeared or shifted on delayed images defined a physiological uptake. For the differential evaluation of persistent focal uptake lesions on delayed images, colonoscopy and histopathologic examination were performed. SUVmax changes between early and delayed images were also compared. Results: Among the 132 patients, 153 lesions of focal colonic uptake were detected on early images of $^{18}$F-FDG PET/CT. Of these, 72 (47.1%) lesions were able to judge with physiological uptake because the focal increased uptake disappeared from delayed image. Among 81 lesions which was showed persistent increased uptake in delayed image, 61 (75.3%) lesions were confirmed as the malignant tumor and 14 (17.3%) lesions were confirmed as the benign lesions including adenoma and inflammatory disease. Remaining 6 (7.4%) lesions were confirmed as the physiological uptake because there was no particular lesion in the colonoscopy. In the malignant lesions, the calculated dual time point change for SUVmax ($\Delta$%SUVmax) was 20.8$\pm$18.7%, indicating a significant increase in SUVmax between the two point (p<0.01). In contrast, the change in SUVmax for the non-malignant lesions including benign lesions and physiological uptake was -13.7%$\pm$24.2%. For the differentiation of the malignant and non-malignant focal colonic uptake lesions, $\Delta$%SUVmax was the most effective parameter, and the cut-off value using -5% provided the best sensitivity, specificity, and accuracy. Conclusion: The dual time point $^{18}$F-FDG PET/CT imaging with SUVmax change evaluation could be an important noninvasive method for the differentiation of malignant and benign focal colonic uptake lesions including physiologic uptake.

A Case of Congenital Extra Hepatic Portocaval Shunt (Abernethy Malformation Type 2) with a very Large Liver Mass and an Atrial Septal Defect (거대 간 종괴와 심방 중격 결손을 동반한 Abernethy 기형 2형 1예)

  • Lee, Hae-Jeong;Lee, Jee-Hyun;Huh, June;Kang, I-Seok;Lee, Heung-Jae;Suh, Yeon-Lim;Yoo, So-Young;Choe, Yon-Ho
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.11 no.1
    • /
    • pp.56-59
    • /
    • 2008
  • Extrahepatic portosystemic shunts, known as Abernethy malformations, were first reported by John Abernethy in 1793. They are classified into two types: Type I refers to a congenital absence of the portal vein and Type II refers to a shunt involving a side-to-side anastomosis with reduced portal blood flow into the liver parenchyma. This malformation is so rare that less than 100 cases have been reported in the medical literature. We report the case of a 13-month-old boy who had a congenital extrahepatic portocaval shunt with a hypoplastic portal vein. This case was complicated with an atrial septal defect and a large hyperplastic nodule in the liver. The patient was diagnosed with a Type II Abernethy malformation. We planned on surgical occlusion of the extrahepatic portocaval shunt. However, six months later, the patient had a sudden onset of a fever of unknown origin and developed hepatic encephalopathy. Although he underwent a liver transplantation, he died of acute hepatic failure.

  • PDF

Effectiveness of Positron Emission Tomography in the Pre-operative Staging of Gastric Cancer (위암환자의 술 전 병기 결정에서 PET-CT의 유용성)

  • Park, Shin-Young;Bae, Jung-Min;Kim, Se-Won;Kim, Sang-Woon;Song, Sun-Kyo
    • Journal of Gastric Cancer
    • /
    • v.9 no.3
    • /
    • pp.110-116
    • /
    • 2009
  • Purpose: The aim of this study was to examine the usefulness of positron emission tomography (PET)-computed tomography (CT) in the pre-operative staging of gastric cancer. Materials and Methods: Between February 2006 and August 2008, PET-CT and CT were performed on 70 patients diagnosed with gastric cancer by gastrofiberscopic biopsy. The sensitivities, specificities, Positive predictive value (PPV), and negative predictive value (NPV) of PET-CT and CT imaging for the detection of gastric cancer TNM staging were compared. Results: The detection rates for the primary tumor were as follows: PET-CT, 81.4% (57/70); and CT, 42.9% (30/70). For both early gastric cancer (EGC) and advanced gastric cancer (AGC), PET-CT was more accurate than CT in detecting the lesions. As the size of the tumor exceeded 3 cm, the detection rate increased. The sensitivities, specificities, PPV, and NPV of PET-CT for lymph node staging were 55.6%, 81%, 86.2%, and 45.9%, while the sensitivities, specificities, PPV, and NPV of CT were 40.0%, 85.7%, 85.7% and 40%, respectively. One case of multiple liver metastasis and two cases of dual primary cancer (rectal and pancreatic cancers) were detected by PET-CT. PET-CT also had a higher detection rate for all histologic types of primary tumors. PET-CT was more accurate than CT in detecting primary gastric cancer lesions. The detection of nodal metastasis by PET-CT was similar to CT; small-sized tumors or EGC detection rates were not high. However, PET-CT provided additional information to detect distant metastases and dual primary cancers and reduced unnecessary laparotomies to detect peritoneal seeding or carcinomatosis. Conclusion: It would be useful to make a pre-operative diagnosis of gastric cancer and determine treatment if PET-CT were added to other routine pre-operative studies.

  • PDF

Evaluation of Average CT to Reduce the Artifact in PET/CT (PET/CT 검사에서 호흡에 따른 인공산물을 줄이기 위한 Average CT의 유용성)

  • Kim, Jung-Sun;Nam, Ki-Pyo;Park, Seung-Yong;Ryu, Jae-Kwang;Cha, Min-Kyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.3-7
    • /
    • 2010
  • Purpose: The usefulness of Positron Emission Tomography (PET) images in diagnosis, staging, recurrent and treatment response evaluation has already been known. However, tumors which are small size, located in lower lobe of lung or upper lobe of liver are shown misalignment, distortion and different Standard Uptake Value (SUV) by respiration in PET images. Therefore, if radiotherapy based on normal respiration, it may cause low treatment response or more side effects because targets which had to treat, out of treat range or over dose to normal tissue. The purpose of this study is to evaluate attenuation-correction with Average CT (ACT) for more accuracy SUV measurement and minimize artifact by respiration. Materials and Methods: 13 patients, who had tumors which are around the diaphragm, underwent ACT scan after Helical CT (HCT) scan with PET/CT (Discovery DSTE 8; GE Healthcare). We quantified the differences between attenuation corrected image with HCT and attenuation corrected image with ACT in artifact size and maximum SUV ($SUV_{max}$). Artifacts were evaluated by measurement of the curved photogenic area in the lower thorax of the PET images for all patients. $SUV_{max}$ was measured separately at the primary tumors. Analysis program was Advantage Workstation v4.3 (GE Healthcare). Patients were injected with 7.4 MBq (0.2 $mC_i$) per kg of $^{18}F$-FDG and scanned 1 hour after injection. The PET acquisition was 3 minute per bed. Results: Significantly lower artifact were observed in PET/ACT images than in PET/HCT images (below-thoracic artifacts caused by under corrected $1.5{\pm}3.5$ cm vs. $13.4{\pm}4.2$ cm). Significantly higher $SUV_{max}$ were noted in PET/ACT images than in PET/HCT images in the primary tumor. Compared with PET/HCT images, $SUV_{max}$ in PET/ACT images were higher by $5.3{\pm}3.9%$ (mean value) tumor. The highest difference was observed in Lower lobe of lung (7.7 to 8.7; 13%). Conclusion: Due to its significantly reduced artifacts in lower thoracic, attenuation corrected image with ACT images provided more reliable $SUV_{max}$ and may be helpful in monitoring treatment response. Moreover, ACT can separate upper lobe of liver and lower lobe of lung, it may be helpful in interpretation. ACT will be clinically useful, considering increased dose caused by ACT scan and adapt.

  • PDF

A Case of Hepatopumonary Syndrome with Cyanosis (청색증으로 내원한 간폐증후군 1예)

  • Ryu, Dae-Sik;Jung, Bock-Hyun;Jung, Sang-Sik;Kim, Ho-Dong;Yoo, Chul-Hee;Kang, Kil-Hyeon;Kim, Nam-Hyeon;Jung, Seung-Mun;Park, Man-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.3
    • /
    • pp.420-425
    • /
    • 1999
  • We report a case of hepatopulmonary syndrome defined as a triad of chronic liver disease, increased alveolar oxygen gradient on room air, and intrapulmonary arteriovenous shunting. Chest rediographs showed bilateral, basilar, medium sized reticulonodular opacities. High resolution CT scand showed multiple centrilobular nodules and branching structures in the subpleural lung that suggested dilatation of lung vessels with abnormally large number of visible terminal branches. $^{99m}Tc$-macroaggregated albumin(MAA) perfusion lung scan showed right to left shunt. Contrast echocardiography demonstrated intrapulmonary vascular shunt without intracardiac shunt.

  • PDF

The Effect of Intravenous Contrast on SUV Value in $^{18}F$-FDG PET/CT using Diagnostic High Energy CT (진단용 고선량 CT를 이용한 $^{18}F$-FDG PET/CT 촬영시 정맥 조영제가 SUV 값에 미치는 영향)

  • Jeong, Young-Jin;Kang, Do-Young
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.3
    • /
    • pp.169-176
    • /
    • 2006
  • Purpose: According to the development of CT scanner in PET/CT system, the role of CT unit as a diagnostic tool has been more important. To improve the diagnostic ability of CT scanner, it is a key aspect that CT scanning has to be performed with high dose energy and intravenous (IV) contrast. So we investigated the effect of IV contrast media on the maximum SUV (maxSUV) of normal tissues and pathologic lesions using PET/CT scanner with high dose CT scanning. Materials & Methods: The study enrolled 13 patients who required PET/CT evaluation. At first, the patients were performed whole body non-contrast CT (NCCT-120 kVp, 130 mAs) scan. Then contrast enhanced CT (CECT) scan was performed immediately. Finally PET scan was followed. The PET omission data were reconstructed twice, once with the NCCT and again with the CECT. We measured the maxSUV of 10 different body regions that were considered as normal in ail patients. Also pathologic lesions were investigated. Results: There were not seen focal artifacts in PET images based on CT with IV contrast agent. Firstly, 130 normal regions in 13 patients were evaluated. The maxSUV was significantly different between two PET images (p<0.00)). The maxSUV was $1.1{\pm}0.5$ in PET images with CECT-corrected attenuation and $1.0{\pm}0.5$ in PET images with NCCI-corrected attenuation. The limit of agreement was $0.1{\pm}0.3$ in Bland-Altman analysis. Especially there were significant differences in 6 of 10 regions, apex and base of the right lung, ascending aorta, segment 6 & segment 8 of the liver and spleen (p<0.05). Secondly, 39 pathologic lesions were evaluated. The maxSUV was significantly different between two PET images (p<0.001). The maxSUV was $4.7{\pm}2.0$ in PET images with CECT-corrected attenuation and $4.4{\pm}2.0$ in PET images with NCCT-corrected attenuation. The limit of agreement was $0.4{\pm}0.8$ in Bland-Altman analysis. Conclusion: Although there were increases of maxSUVs in the PET images based on CT with IV contrast agent, it was very narrow in the range of limit of agreement. So there was no significant effect to clinical interpretation for PET images that were corrected attenuation with high dose CT using IV contrast.

Evaluation of Usefulness of an m-DIXON Technique during an Abdomen MRI Examination : A Comparison with an e-THRIVE Technique (복부 MRI검사에서 m-DIXON기법의 유용성 평가: e-THRIVE기법과 비교 분석)

  • Lee, Bo-Woo;Park, Myung-Cheol;Lee, Jin-Hoi;Kim, Ki-Jin;Bae, Seok-Hwan
    • Journal of Digital Convergence
    • /
    • v.12 no.10
    • /
    • pp.385-390
    • /
    • 2014
  • This research is conducted to identify whether an m-DIXON technique which is useful for an abdomen MRI examination compared with an existing e-THRIVE technique is a clinically useful or not. There was evaluated quantitative and qualitative to 84 subjects who had abdomen MRI exam due to their liver disease were conducted during a period from September in 2013 to February in 2014. First of all the quantitative evaluation, the m-DIXON technique's SNR was $90.42{\pm}16.90$ and the e-THRIVE technique was $60.42{\pm}11.54$ and the m-DIXON technique's CNR was $52.38{\pm}22.58$ and the e-THRIVE technique was $46.31{\pm}20.25$. Secondly in the qualitative evaluation, the m-DIXON technique's image quality was $4.06{\pm}0.34$, a artifact was $3.64{\pm}0.22$, and fat suppression was $4.16{\pm}0.15$, the e-THRIVE technique's image quality was $3.14{\pm}0.35$, a artifact was $3.06{\pm}0.38$, fat suppression was $3.14{\pm}0.30$. In conclusion, m-DIXON technique for abdomen MRI examination showed superiority over both SNR as a quantitative anaylsis, CNR and a qualitative analysis.