• Title/Summary/Keyword: Live loads of buildings

Search Result 15, Processing Time 0.019 seconds

A Study on Live Loads in School (학교교실의 적재하중에 관한 연구)

  • 서극수;박성수
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1994.10a
    • /
    • pp.61-69
    • /
    • 1994
  • The most fundamental elements in analyzing the structure of building are strength of maerials and value of loads. The applied loads of structural analysis in our country are classified into the dead and live loads. This study, with special reference to live load, is to suggest the stochastic character of live load and the appropriate live load by using the Monte-carlo Simulation method, one of the O. R(Operations Research) techniques acting on school buildings.

  • PDF

Determining the Maximum Capacity of a Small Wind Turbine System Considering Live Loads of Buildings (건물의 활하중을 고려한 소형풍력발전시스템의 최대 설비용량 선정기법)

  • Lee, Yeo-Jin;Kim, Sung-Yul
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.3
    • /
    • pp.165-170
    • /
    • 2016
  • Due to environmental issues such as global warming, the reduction of greenhouse gas emissions has become an inevitable measure to be taken. Among others, the building sector accounts for 50% of total carbon dioxide emissions, which is significantly high. Therefore, in order to reduce carbon dioxide emissions of the buildings, improving the energy efficiency by utilizing wind power among renewable energy sources is recommended. In case of buildings in the planning stage, it is possible to take the load of wind power generation systems into consideration when determining installed capacity. Already completed buildings, however, should be connected to small wind electric systems according to the live loads of the buildings based on the architectural design criteria. In order to connect to a building that has already been completed, it is necessary to consider the load of the small wind electric system as well as the live load of building. In addition, we need to generate the maximum electricity possible by determining the maximum installed capacity in a small area. In this paper, we propose the method for determining maximum capacity for building integrated small wind electric systems, which takes into account the considerations associated with connecting small wind electric systems to completed buildings. This can be developed into a system linked to solar power, which makes it possible to improve the energy independence of the building. In addition, carbon dioxide reduction by improving energy efficiency is expected.

Probabilistic Analysis of Lifetime Extreme Live Loads in Office Buildings (사무실의 사용기간 최대 적재하중에 대한 확률론적 분석)

  • 김상효;조형근;배규웅;박흥석
    • Computational Structural Engineering
    • /
    • v.3 no.1
    • /
    • pp.109-116
    • /
    • 1990
  • Live load data in domestic office buildings have been collected in a systematic manner. Based on surveyed data, equivalent uniformly distributed load intensities, which produce the same load effect as the actual spatially varying, live load, have been obtained for various structural members (such as slab, beam, column, etc. ). Influence surface method has been employed to compute load effects under real live load, including beam moment, slab moment as well as axial force in column. The results have been examined to find probabilistic characteristics and relationship between influence area and load intensity (or coefficient of variation). The results were also compared with other survey results and found to be reasonable. Based on the probabilistic load models obtained, the lifetime extreme values have been analyzed and compared with current design loads. Tentative equations applicable to decide more rational design loads are also suggested as functions of influence area.

  • PDF

Comparative Evaluation of Structural Systems for Tilted Tall Buildings

  • Moon, Kyoung Sun
    • International Journal of High-Rise Buildings
    • /
    • v.3 no.2
    • /
    • pp.89-98
    • /
    • 2014
  • Employing tilted forms in tall buildings is a relatively new architectural phenomenon, as are the cases with the Gate of Europe Towers in Madrid and the Veer Towers in Las Vegas. This paper studies structural system design options for tilted tall buildings and their performances. Tilted tall buildings are designed with various structural systems, such as braced tubes, diagrids and outrigger systems, and their structural performances are studied. Structural design of today's tall buildings built with higher strength materials is generally governed by lateral stiffness. Tilted towers are deformed laterally not only by lateral loads but also by dead and live loads due to their eccentricity. The impact of tilting tall buildings on the gravity and lateral load resisting systems is studied. Comparative evaluation of structural systems for tilted tall buildings is presented.

Probabilistic Analysis of Equivalent Uniformly Distributed live toads (등가등분포 적재하중의 확률론적 분석)

  • 김상효;정시현;조형근
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1989.04a
    • /
    • pp.1-4
    • /
    • 1989
  • Since 1960's, structural engineers have recognized that tile inherent random nature of loadings and materials as well as the imperfect structural analysis may be important factors in tile structural safety evaluation. Based on the successful developments of the reliability based structural analysis and design, the design criteria of tile standards are recently developed(or modified) in the light of the probabilistic concepts. To develop the probability-based design criteria for tile domestic buildings, the probabilistic characters of loadings acting on structures should be defined first. In this study, therefore, live load data on apartment buildings have collected and analyzed in a systematic manner, and their probabilistic characteristics have been studied. Based oil the results, the lifetime extreme values are computed and compared with current design loads. More rational design loads are suggested, which are more consistent in the probabilistic concepts.

  • PDF

Study on Live Loads in Office Buildings (사무실 적재하중의 통계적 조사 연구)

  • 김상효;조형근;배규웅;박홍석
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1989.10a
    • /
    • pp.25-28
    • /
    • 1989
  • Live load data in domestic office buildings have been collected in a systematic manner. Based on surveyed data, equivalent uniformly distributed load intensities, which produce the same load effect as the actual spatially varying live load, have been obtained for various structural members(such as slab, beam, column, etc.). Influence surface method has been employed to compute load effects under real live load, inclucing beam moment, slab moment as well as axial force and moments in column. The results have been examined to find probabilistic characteristics and relationship between influence area and load intensity(or coefficient of variation). The results were also compared with other survey results and found to be reasonable.

  • PDF

Probabilistic Analysis of Equivalent Uniformly Distributed Live Loads (등가등분포 적재하중의 확률론적 분석)

  • 김상효;정시현;조형근
    • Computational Structural Engineering
    • /
    • v.2 no.2
    • /
    • pp.93-99
    • /
    • 1989
  • Since 1960's, structural engineers have recognized that the inherent random nature of loadings and materials as well as the imperfect structural analysis may be important factors in the structural safety evaluation. Based on the successful developments of the reliability-based structural analysis and design, the design criteria of the standards are recently developed(or modified) in the light of the probabilistic concepts. To develop the probability - based criteria for the domestic buildings, the probabilistic characteristic of loadings acting on structures should be defined first. In this study, therefore, live load data on apartment buildings have been collected and analyzed in systematic manner, and their probabilistic characteristics have been studied. Based on the results, the lifetime extreme values are computed and compared with current design loads. More rational design loads are suggested, which are more consistent in the probabilistic concepts.

  • PDF

A Study on Configuration of Small Wind Turbines for Maximum Capacity of Wind Power Systems Interconnected With a Building (빌딩 내 최대 풍력발전설비 연계를 위한 소형풍력발전원 구성에 관한 연구)

  • Lee, Yeo-Jin;Kim, Sung-Yul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.4
    • /
    • pp.605-612
    • /
    • 2017
  • One of the biggest environmental issues that our world has been facing is climate change. In order to cope with such environmental issues, the world is putting a great deal of effort into energy conservation. The building sector, in particular, consumes 36% of the energy consumed worldwide and emits considerable amount of greenhouse gases. Therefore, introduction of renewable energies in the building sector is highly recommended. Renewable energy sources that can be utilized in the building sector include sunlight, solar heat, geothermal heat, fuel cells and wind power. The wind power generation system which converts wind energy into electrical energy has advantages in that wind is an unlimited and pollution-free resource. It is suitable to be connected to existing buildings because many years of operational experience and the enhanced stability of the system have made it possible to downsize the electrical generator. In case of existing buildings, it is necessary to consider the live loads of the buildings to connect the wind power generation system. This paper, through the connection of the wind power generation with existing buildings, promotes reduction of greenhouse gas emissions and energy independence by reducing energy consumption in the building sector. In order to connect the wind power generation system with an exciting building, the live load of the building and the area of the rooftop should be considered. The installable model is selected by comparing the live load of the building and the load of the wind power generation system. The maximum number of the wind turbines that can be installed is obtained by considering the separation distance between the wind turbines within the area of the rooftop. Installations are divided into single installations and multiple installations of two different types of wind turbines. After determining the maximum installable number, the optimal model that can achieve the maximum annual power generation will be selected by comparing the respective total annual amount of the power generation of different models.

Robust optimization of a hybrid control system for wind-exposed tall buildings with uncertain mass distribution

  • Venanzi, Ilaria;Materazzi, Annibale Luigi
    • Smart Structures and Systems
    • /
    • v.12 no.6
    • /
    • pp.641-659
    • /
    • 2013
  • In this paper is studied the influence of the uncertain mass distribution over the floors on the choice of the optimal parameters of a hybrid control system for tall buildings subjected to wind load. In particular, an optimization procedure is developed for the robust design of a hybrid control system that is based on an enhanced Monte Carlo simulation technique and the genetic algorithm. The large computational effort inherent in the use of a MC-based procedure is reduced by the employment of the Latin Hypercube Sampling. With reference to a tall building modeled as a multi degrees of freedom system, several numerical analyses are carried out varying the parameters influencing the floors' masses, like the coefficient of variation of the distribution and the correlation between the floors' masses. The procedure allows to obtain optimal designs of the control system that are robust with respect to the uncertainties on the distribution of the dead and live loads.

Experimental Study on Combustion Characteristics of Live Fire Load in a Bookstore (서점의 적재가연물의 연소특성에 관한 실험적 연구)

  • Nam, Dong-Gun
    • Fire Science and Engineering
    • /
    • v.25 no.5
    • /
    • pp.47-53
    • /
    • 2011
  • Fire load in buildings greatly contribute to the time and scale of fire according to the type and quantity of the fire load. Because bookstores have a large quantity of fire load compared with other buildings which may lead to large scale fires, however, their heat release characteristics have been hardly investigated. In this study, to obtain the data applicable for the performance-based fire safety design of bookstores, the specimens representing stacked fire loads were heated in a furnace in compliance with the standard heating curve of ISO834-1:1999 to investigate their heat release characteristics. From the experiment result, the combustion velocity and heat release rate required for performancebased fire safety designs are obtained.