• Title/Summary/Keyword: Liquid-based preparation

Search Result 115, Processing Time 0.035 seconds

One Step Fabrication of Organic Nanowires by using Direct Printing Method

  • Hwang, Jae.-K.;Sung, Myung-M.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.158-158
    • /
    • 2011
  • A wide range of techniques for the direct-printing of functional materials have been developed for the fabrication of micro- and nanoscale structures and devices. Here we report a new direct patterning method, liquid bridge-mediated nanotransfer molding (LB-nTM), for the formation of two- or three-dimensional structures with feature sized as small as tens of nanometers over large areas up to 4". LB-nTM is based on the direct transfer of various materials from a mold to a substrate via a liquid bridge between them. The LB-nTM method was applied to the preparation of organic nanowire FETs on flexible substrates.

  • PDF

Isolation of a Calcium-binding Peptide from Chlorella Protein Hydrolysates

  • Jeon, So-Jeong;Lee, Ji-Hye;Song, Kyung-Bin
    • Preventive Nutrition and Food Science
    • /
    • v.15 no.4
    • /
    • pp.282-286
    • /
    • 2010
  • To isolate a calcium-binding peptide from chlorella protein hydrolysates, chlorella protein was extracted and hydrolyzed using Flavourzyme, a commercial protease. The degree of hydrolysis and calcium-binding capacity were determined using trinitrobenzenesulfonic acid and orthophenanthroline methods, respectively. The enzymatic hydrolysis of chlorella protein for 6 hr was sufficient for the preparation of chlorella protein hydrolysates. The hydrolysates of chlorella protein were then ultra-filtered under 5 kDa as molecular weight. The membrane-filtered solution was fractionated using ion exchange, reverse phase, normal phase chromatography, and fast protein liquid chromatography to identify a calcium-binding peptide. The purified calcium-binding peptide had a calcium binding activity of 0.166 mM and was determined to be 700.48 Da as molecular weight, and partially identified as a peptide containing Asn-Ser-Gly-Cys based on liquid chromatography/electrospray ionization tandem mass spectrum.

Effects of Aluminum Tristearate in the Preparation of Sustained Release Ethambutol Hydrochloride Microcapsules (지속 방출형 염산에탐부톨 마이크로캅셀의 제조에 있어서 스테아린산알루미늄의 효과)

  • Yoo, Bong-Shin
    • Journal of Pharmaceutical Investigation
    • /
    • v.18 no.4
    • /
    • pp.175-180
    • /
    • 1988
  • The role and effect of aluminum tristearate in microencapsulation were investigated based on the dispersion system of ethambutol hydrochloride in acetone-liquid paraffin. Eudragit RS was used as a wall-forming material. Eudragit RS microcapsules prepared using aluminum tristearate were uniform, free-flowing particles. The phase diagram of ethambutol hydrochloride-Eudragit RS-aluminum tristearate indicated that spherical microcapsules ranging from 250 to 1400 ${\mu}m$ in diameter could be prepared only in a very limited region. Instrumental analysis using an energy dispersive-type X-ray microanalyser and a scanning electron microscope showed that aluminum tristearate was localized near the surface of microcapsules. From these results, it was presumed that aluminum tristearate reduced the phase tension between Eudragit microcapsules and liquid paraffin. The dissolution rates of ethambutol hydrochloride from Eudragit RS microcapsules were consideraly lower than those from ethambutol hydrochloride powders and decreased as the amount of aluminum tristearate decreased.

  • PDF

Emission Reduction by Mixture Formation in a Diesel-Natural Gas Dual-Fuel Engine at Low Loads (경유-천연가스 이종연료 엔진의 저부하 영역에서 혼합기 형성을 통한 배기배출 저감)

  • Park, Hyunwook;Lee, Junsun;Oh, Seungmook;Kim, Changup;Lee, Yongkyu;Bae, Choongsik
    • Journal of ILASS-Korea
    • /
    • v.24 no.4
    • /
    • pp.194-202
    • /
    • 2019
  • A mixture preparation strategy was proposed and evaluated in a diesel-natural gas dual-fuel engine to reduce hydrocarbon (HC) and carbon monoxide (CO) emissions under low load conditions. An experimental investigation was conducted in a single-cylinder compression-ignition engine. Natural gas was supplied with air during the intake stroke, and diesel was injected directly into the combustion chamber during the compression stroke. First, effects of diesel start of energizing (SOE) and natural gas substitution ratio on the combustion and exhaust gas emissions were analyzed. Based on the results, the mixture preparation strategy was established. A low natural gas substitution ratio and a high exhaust gas recirculation (EGR) rate were effective in reducing the HC and CO emissions.

A Study on the Optimum Bonding Preparation Condition of Single Crystal Superalloy (단결정 초내열합금의 재결정 방지를 위한 접합 전처리 조건에 관한 연구)

  • 김대업
    • Journal of Welding and Joining
    • /
    • v.19 no.2
    • /
    • pp.191-199
    • /
    • 2001
  • The oxidation and recrystallization behaviors of Ni-base single crystal superalloy, CMSX-2 were investigated to determine the condition of the preparation for transient liquid phase (TLP) bonding operations. The faying surfaces of CMSX-2 were worked by the shot peening, fine cutting and mechanical polishing treatments and the degree of working of treated surfaces was evaluated by the hardness test and X-ray diffraction method CMSX-2 was heat-treated at 1,173∼1.589k for 3.6ks in vacuum of 4mPa. The mechanically polished surface was slightly oxidized after heat treatment even in the vacuum atmosphere of 4mPa. The thickness of an oxide film increased with increasing the heating temperature and the surface roughness of the faying surface. Recrystallization occurred at the surface after heat treatment at above 1,423K when the hardness was increased more than Hv600 by the shot peening treatment while the mechanically polished or fine cut surfaces didn't recrystallized. Based on these results, it was clearfied that the mechanically polishing with fine abrasive grit could be used for the preparation of faying surface of CMSX-2 before bonding operation.

  • PDF

A Comparision of AutoCyte PREP with Matched Conventional Smear in Cervicovaginal Cytology (자궁경부 세포검사에서 기존 도말과 AutoCyte PREP의 비교)

  • Jang, Jae-Jung;Kim, Jung-Sun;Cho, Kyung-Ja;Khang, Shin-Kwang;Nam, Joo-Hyun;Gong, Gyung-Yub
    • The Korean Journal of Cytopathology
    • /
    • v.13 no.1
    • /
    • pp.8-13
    • /
    • 2002
  • This study was designed to compare the performance of liquid-based preparation from the AutoCyte PREP with the conventional cervicovaginal smear in masked split-samples. In randomly selected 840 cases, the conventional smear was always prepared first, and the AutoCyte PREP used the resldual cells on the collecting device. Parallel AutoCyte PREP slides and matched conventional smears were screened in a blind fashion. All abnormals and 10% random normal cases were reviewed by two pathologists in a blind fashion. The Bethesda System was used for reporting the diagnosis and specimen adequacy. The diagnoses from the two methods were agreed exactly in 767(91.3%) of 840 cases. The AutoCyte PREP demonstrated a 25% overall improvement in the detection of squamous intraepithelial lesion(SIL). The ratio of ASCUS to SIL was decreased as 0.45 compared with 1.00 of conventional smear. The AutoCyte PREP produced excellent cellular preservation and superior sensitivity for detection of atypical cells as compared to the conventional smear. It makes us to be able to subclassify ASCUS into from WNL to HSIL. We thought that the AutoCyte PREP method might contribute to increase the detection rate of abnormal cells than conventional methods.

Comparison of Cell Lysis Techniques via Q-TOF LC/MS

  • Kaplan, Ozan;Oncul, Selin;Ercan, Ayse;Celebier, Mustafa
    • Mass Spectrometry Letters
    • /
    • v.11 no.2
    • /
    • pp.36-40
    • /
    • 2020
  • Untargeted metabolomics is a useful tool for drug development focusing on novel chemotherapeutic and chemopreventative agents against cancer cells. In recent years, quadrupole time of flight liquid chromatography-mass spectrometry (Q-TOF LC/MS)-based untargeted metabolomic approaches have gained importance to evaluate the effect of these agents at the molecular level. The researchers working on cell culture studies still do not apply standardized methodologies on sample preparation for untargeted metabolomics approaches. In this study, the rough and wet lysis techniques performed on MCF-7 breast cancer cells were compared with each other via the Q-TOF LC/MS-based metabolomic approach. The C18 and hydrophilic interaction liquid chromatography (HILIC) columns were used for the separation of the metabolites in MCF-7 cell lysates. 505 peaks were detected through the HILIC column and 551 peaks were found through the C18 column for the wet lysis technique. This situation supported by the base peak chromatograms showed that the wet lysis technique allowed us to extract higher number of non-polar metabolites. Almost equal number of metabolites was found for the C18 and HILIC columns (697 peaks for the HILIC column and 695 peaks for the C18 column) when the rough lysis technique was used. However, the intensities of polar metabolites were higher for the rough lysis technique on base peak chromatograms for both the HILIC and C18 columns. Although cell lysis technique, which is the first step in the sample preparation for cell culture studies, does not cause dramatic differences in the number of the detected metabolite peaks, it affects the polar and non-polar metabolite ratio significantly. Therefore, it must be considered carefully especially for in vitro drug development studies.

Headspace Hanging Drop Liquid Phase Microextraction and Gas Chromatography-Mass Spectrometry for the Analysis of Flavors from Clove Buds

  • Jung, Mi-Jin;Shin, Yeon-Jae;Oh, Se-Yeon;Kim, Nam-Sun;Kim, Kun;Lee, Dong-Sun
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.2
    • /
    • pp.231-236
    • /
    • 2006
  • A novel sample pretreatment technique, headspace hanging drop liquid phase microextraction (HS-LPME) was studied and applied to the determination of flavors from solid clove buds by gas chromatography-mass spectrometry (GC-MS). Several parameters affecting on HS-LPME such as organic solvent drop volume, extraction time, extraction temperature and phase ratio were investigated. 1-Octanol was selected as the extracting solvent, drop size was fixed to 0.6 $\mu$L. 60 min extraction time at 25 ${^{\circ}C}$ was chosen. HS-LPME has the good efficiency demonstrated by the higher partition equilibrium constant ($K_{lh}$) values and concentration factor (CF) values. The limits of detection (LOD) were 1.5-3.2 ng. The amounts of eugenol, $\beta$-caryophyllene and eugenol acetate from the clove bud sample were 1.90 mg/g, 1.47 mg/g and 7.0 mg/g, respectively. This hanging drop based method is a simple, fast and easy sample enrichment technique using minimal solvent. HSLPME is an alternative sample preparation method for the analysis of volatile aroma compounds by GC-MS.

Safety, Efficacy, and Physicochemical Characterization of Tinospora crispa Ointment: A Community-Based Formulation against Pediculus humanus capitis

  • Torre, Gerwin Louis Tapan Dela;Ponsaran, Kerstin Mariae Gonzales;de Guzman, Angelica Louise Dela Pena;Manalo, Richelle Ann Mallapre;Arollado, Erna Custodio
    • Parasites, Hosts and Diseases
    • /
    • v.55 no.4
    • /
    • pp.409-416
    • /
    • 2017
  • The high prevalence of pediculosis capitis, commonly known as head lice (Pediculus humanus capitis) infestation, has led to the preparation of a community-based pediculicidal ointment, which is made of common household items and the extract of Tinospora crispa stem. The present study aimed to evaluate the safety, efficacy, and physicochemical characteristics of the T. crispa pediculicidal ointment. The physicochemical properties of the ointment were characterized, and safety was determined using acute dermal irritation test (OECD 404), while the efficacy was assessed using an in vitro pediculicidal assay. Furthermore, the chemical compounds present in T. crispa were identified using liquid-liquid extraction followed by ultra-performance liquid chromatography quadruple time-of-flight mass spectrometric (UPLC-qTOF/MS) analysis. The community-based ointment formulation was light yellow in color, homogeneous, smooth, with distinct aromatic odor and pH of $6.92{\pm}0.09$. It has spreadability value of $15.04{\pm}0.98g{\cdot}cm/sec$ and has thixotropic behavior. It was also found to be non-irritant, with a primary irritation index value of 0.15. Moreover, it was comparable to the pediculicidal activity of the positive control $Kwell^{(R)}$, a commercially available 1% permethrin shampoo (P>0.05), and was significantly different to the activity of the negative control ointment, a mixture of palm oil and candle wax (P<0.05). These findings suggested that the community-based T. crispa pediculicidal ointment is safe and effective, having acceptable physicochemical characteristics. Its activity can be attributed to the presence of compounds moupinamide and physalin I.

Liquid-Based Cytology Using $MonoPrep2^{TM}$ System in Cervicovaginal Cytology: Comparative Study with Conventional Pap Smear and Histology (고식적 직접 도말법과 $MonoPrep2^{TM}$ system 법에 의한 자궁경부질 세포검사 성적의 비교 검토)

  • Jeon, Yoon-Kyung;Kim, Ok-Ran;Park, Ki-Wha;Kang, Soon-Beom;Park, In-Ae
    • The Korean Journal of Cytopathology
    • /
    • v.15 no.1
    • /
    • pp.33-39
    • /
    • 2004
  • We compared the diagnostic accuracy of liquid-based cervicovaginal cytology using $MonoPrep2^{TM}$ system (Monogen, Herndon, Virginia, USA), a manual system based on membrane filtration method, with conventional Pap smear. Study population included 92 patients visiting the gynecologic department under the suspicion of uterine cervical disease. In thirty of them, surgical biopsy was performed. $MonoPrep2^{TM}$ system provided well-preserved monolayer specimen with good nuclear morphology. However, about 19% of specimens were inadequate to interpret due to low cellularity. The detection rate of abnormal cells more than ASCUS (atypical squamous cells of unknown significance) was 23.9% and higher than 19.4 % of conventional Pap smear. Diagnostic concordance rate with conventional Pap smear was 81%, and severe discordance rate influencing on the management of patient was 7.6 %. Among these seven cases, $MonoPrep2^{TM}$ system was more diagnostic only in four. In comparison with histology, the sensitivity of diagnosis of $MonoPrep2^{TM}$ system was 78.9% and slightly higher than 73.5% of conventional Pap smear. However, the specificity was 81.1% and lower than 90.9% of Pap smear. In conclusion, $MonoPrep2^{TM}$ system provided diagnostic accuracies similar to the conventional Pap smear. The inexpertness of slide preparation and the low cellularity were considered to endow a limitation in more accurate evaluation.