• 제목/요약/키워드: Liquid scintillator detector

검색결과 7건 처리시간 0.026초

Digital n-γ Pulse Shape Discrimination in Organic Scintillators with a High-Speed Digitizer

  • Kim, Chanho;Yeom, Jung-Yeol;Kim, Geehyun
    • Journal of Radiation Protection and Research
    • /
    • 제44권2호
    • /
    • pp.53-63
    • /
    • 2019
  • Background: As neutron fields are always accompanied by gamma rays, it is essential to distinguish neutrons from gamma rays in the detection of neutrons. Neutrons and gamma rays can be separated by pulse shape discrimination (PSD) methods. Recently, we performed characterization of a stilbene scintillator detector and an EJ-301 liquid scintillator detector with a high-speed digitizer DT5730 and investigated optimized PSD variables for both detectors. This study is for providing a basis for developing fast neutron/gamma-ray dual-particle imager. Materials and Methods: We conducted PSD experiments using stilbene scintillator and EJ-301 liquid scintillator and evaluated neutron and gamma ray discriminability of each PSD method with a $^{137}Cs$ gamma source and a $^{252}Cf$ neutron source. We implemented digital signal processing techniques to apply two PSD methods - the charge comparison (CC) method and the constant time discrimination (CTD) method - to distinguish neutrons from gamma rays. We tried to find optimized PSD variables giving the best discriminability in a given experimental condition. Results and Discussion: For the stilbene scintillator detector, the charge comparison method and the constant time discrimination method both delivered the PSD FOM values of 1.7. For the EJ-301 liquid scintillator detector, both PSD methods delivered the PSD FOM values of 1.79. With the same PSD variables, PSD performance was excellent in $300{\pm}100keVee$, $500{\pm}100keVee$, and $700{\pm}100keVee$ energy regions. This result shows that we can achieve an effective discrimination of neutrons from gamma rays using these scintillator detector systems. Conclusion: We applied both PSD methods to a stilbene and a liquid scintillator and optimized the PSD performance represented by FOM values. We observed a good separation performance of both scintillators combined with a high-speed digitizer and digital PSD. These results will provide reference values for the dual-particle imager we are developing, which can image both fast neutrons and gamma rays simultaneously.

Flexible liquid light-guide-based radiation sensor with LaBr3:Ce scintillator for remote gamma-ray spectroscopy

  • Jae Hyung Park;Siwon Song;Seunghyeon Kim;Taeseob Lim;Jinhong Kim;Bongsoo Lee
    • Nuclear Engineering and Technology
    • /
    • 제55권3호
    • /
    • pp.1045-1051
    • /
    • 2023
  • In this study, we fabricated a liquid light-guide-based radiation sensor with a LaBr3:Ce scintillator for remote gamma-ray spectroscopy. We acquired the energy spectra of Cs-137 and Co-60 using the proposed sensor, estimated the energy resolutions of the full energy peaks, and compared the scintillation light output variations. The major peaks of the radionuclides were observed in each result, and the estimated energy resolutions were similar to that of a general NaI(Tl) scintillation detector without a liquid light guide. Moreover, we showed the relationships of energy resolution and analog-to-digital channel regarding the number of photoelectrons produced and confirmed the effects of light guide length on remote gamma-ray spectroscopy. The proposed sensor is expected to be utilized to perform remote gamma-ray spectroscopy for distances of 3 m or more and would find application in many fields of nuclear facilities and industry.

Nuclear Physics Methods for Determination of Radon in Water

  • Oyunchimeg, Ts.;Norov, N.;Khuukhenkhuu, G.
    • 한국의학물리학회지:의학물리
    • /
    • 제13권1호
    • /
    • pp.51-53
    • /
    • 2002
  • The results of the measured specific activities of Rn-222 in sewerage and drinking water of Ulaanbaatar City, Mongolia using the HP-Ge gamma-spectrometer, solid state nuclear track detector and liquid scintillator, are compared. The specific radioactivity for the Rn-222 in water of Ulaanbaatar City ranged 10-250 Bk/l, with an average of 110 Bk/l.

  • PDF

Detection of Antineutrinos for Reactor Monitoring

  • Kim, Yeongduk
    • Nuclear Engineering and Technology
    • /
    • 제48권2호
    • /
    • pp.285-292
    • /
    • 2016
  • Reactor neutrinos have been detected in the past 50 years by various detectors for different purposes. Beginning in the 1980s, neutrino physicists have tried to use neutrinos to monitor reactors and develop an optimized detector for nuclear safeguards. Recently, motivated by neutrino oscillation physics, the technology and scale of reactor neutrino detection have progressed considerably. In this review, I will give an overview of the detection technology for reactor neutrinos, and describe the issues related to further improvements in optimized detectors for reactor monitoring.

A 235U mass measurement method for UO2 rod assembly based on the n/γ joint measurement system

  • Yang, Jianqing;Zhang, Quanhu;Su, Xianghua;Li, Sufen;Zhuang, Lin;Hou, Suxia;Huo, Yonggang;Zhou, Hao;Liu, Guorong
    • Nuclear Engineering and Technology
    • /
    • 제52권5호
    • /
    • pp.1036-1042
    • /
    • 2020
  • Fast-Neutron Multiplicity Counter based on Liquid Scintillator Detector can directly measure the fast neutron multiplicity emitted by UO2 rod. HPGe gamma spectrometer; which has superior energy resolution; is routinely used for the gamma energy spectrum measurement. Combing Fast-Neutron Multiplicity Counter and HPGe γ-spectrometer, the n/γ joint measurement system is developed. The fast neutron multiplicity and gamma energy spectrum of UO2 rod assemblies under different conditions are measured by the n/γ joint measurement system. The induced fission rate and the 235U abundance, thereby the 235U mass; can be obtained for UO2 rod assemblies. The 235U mass deviation of the measured value from the reference value is less than 5%. The results show that the n/γ joint measurement system is effective and applicable in the measurement of the 235U mass in samples.

Uranium Analysis in Aqueous Samples by Selective Extraction and Photon-Electron Rejecting Alpha Liquid Scintillation $(PERALS^\circledR)$ Spectrometry

  • Shin, Hyun-Sang;Lee, Myung-Ho;Park, Geun-Sik;Lee, Chang-Woo
    • Nuclear Engineering and Technology
    • /
    • 제31권5호
    • /
    • pp.445-454
    • /
    • 1999
  • This work describes the adaptation of extractive scintillation by URAE $X^{TM}$ with a photon-electron rejecting alpha liquid scintillation (PERAL $S^{)}$ spectrometer to the analysis of uranium in aqueous samples. The extraction efficiency of the system was evaluated under varing chemical conditions including pH, and sample-cocktail volume ratio. Isotopic information from the (PERAL $S^{)}$ spectrum of natural uranium was obtained using a curve fitting routine. Comparisons of the result with that obtained from alpha spectrometry method using ion implanted silicon detector showed good agreement.t.

  • PDF

Measurement of Gamma-ray Yield from Thick Carbon Target Irradiated by 5 and 9 MeV Deuterons

  • Araki, Shouhei;Kondo, Kazuhiro;Kin, Tadahiro;Watanabe, Yukinobu;Shigyo, Nobuhiro;Sagara, Kenshi
    • Journal of Radiation Protection and Research
    • /
    • 제42권1호
    • /
    • pp.16-20
    • /
    • 2017
  • Background: The design of deuteron accelerator neutron source facilities requires reliable yield estimation of gamma-rays as well as neutrons from deuteron-induced reactions. We have so foar measured systematically double-differential thick target neutron yields (DDTTNYs) for carbon, aluminum, titanium, copper, niobium, and SUS304 targets. In the neutron data analysis, the events of gamma-rays taken simultaneously were treated as backgrounds. In the present work, we have re-analyzed the experimental data for a thick carbon target with particular attention to gamma-ray events. Materials and Methods: Double-differential thick target gamma-ray yields from carbon irradiated by 5 and 9 MeV deuterons were measured using an NE213 liquid organic scintillator at the Kyushu University Tandem accelerator Laboratory. The gamma-ray energy spectra were obtained by an unfolding method using FORIST code. The response functions of the NE213 detector were calculated by EGS5 incorporated in PHITS code. Results and Discussion: The measured gamma-ray spectra show some pronounced peaks corresponding to gamma-ray transitions between discrete levels in residual nuclei, and the measured angular distributions are almost isotropic for both the incident energies. Conclusion: PHITS calculations using INCL, GEM, and EBITEM models reproduce the spectral shapes and the angular distributions generally well, although they underestimate the absolute gamma-ray yields by about 20%.