• Title/Summary/Keyword: Liquid penetration

Search Result 327, Processing Time 0.028 seconds

Comparison on Spray Characteristics of Diesel HEV Injectors for 3-different Driving Type (SI, PI, DPI) (3개 구동방식(SI, PI, DPI)별 디젤HEV용 인젝터의 분무 특성 비교)

  • Chung, M.C.;Sung, G.S.;Kim, S.M.;Lee, J.W.
    • Journal of ILASS-Korea
    • /
    • v.19 no.1
    • /
    • pp.9-14
    • /
    • 2014
  • Performance of DI diesel engine with high-pressure fuel injection equipment is directly related to its emission characteristics and fuel consumption. So, the electro-hydraulic injector for the common-rail injection system should be designed to meet the precise high fuel delivery control capability. Currently, most high pressure injector in use has a needle driven by the solenoid coil energy or the piezo actuator controlled by charge-discharge of output pulse current. In this study, macroscopic spray approaching method was applied under constant volume chamber to research the performance of three different injectors : solenoid, indirect-acting piezo and direct-acting piezo type for CR direct-injection. LED back illumination for Mie scattering was applied on the liquid spray visible of direct-acting piezo injector, including hydraulic-servo type solenoid and piezo-driven injectors. As main results, we found that a direct-acting piezo injector had better a spray tip penetration than hydraulic-servo injectors in spray visualization.

An Experimental Study on the Leakage Characteristics and Durability Evaluation of an LPLi Injector (LPLi 인젝터의 누설특성 및 내구평가에 관한 실험적 연구)

  • Choi, Young;Kim, Chang-Up;Oh, Seung-Mook;Kang, Kern-Yong
    • Journal of ILASS-Korea
    • /
    • v.12 no.4
    • /
    • pp.204-210
    • /
    • 2007
  • The worldwide energy problem and global warming cause the need of alternative fuels which feature low carbon-dioxide emission and another energy source. Liquefied Petroleum Gas (LPG) is one of the alternative fuels widely used as domestic and transportational fuel. The third generation LPLi fuel supply system has merits in the increase of engine power and low emissions. The injectors used in LPLi system should overcome a leakage problem and satisfy the durability conditions. Therefore, 1000 hour durability test of the injectors was carried out throughout this research. First, the spray pattern and the penetration length of the selected injectors is graphically shown. Next, the leakage amount with respect to the injection cycle is introduced. Finally, the shapes of nozzle holder and nozzle tip after durability test was investigated by analyzing the microscopic image of the injector tip. The variation in the shape of nozzle tip mainly due to the residue of rubber materials is found to be the reason for leakage.

  • PDF

Characteristic Accelerated Aging Assessment for Coolant Rubber Hose of Automotive Radiator (자동차 냉각기 고무호스의 가속 노화거동 평가)

  • Kwak, Seung-Bum;Choi, Nak-Sam;Kang, Bong-Sung;Shin, Sei-Moon
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2006.05a
    • /
    • pp.27-31
    • /
    • 2006
  • Rubber hoses for automobile radiators are apt to degraded and thus failed due to the influence of contacting stresses of air and coolant liquid under thermal and mechanical loadings. The aging behaviors of the skin part of the hoses due to thermo-oxidative and electro-chemical stresses were experimentally analyzed. Through the thermo-oxidative aging test, it was shown that the surface hardness IRHD(International Rubber Hardness Degrees) of the rubber increased with a considerable reduction of failure strain as the aging time and temperature were large. On account of the penetration of coolant liquid into the skin part the weight of rubber specimens influenced by electro-chemical degradation (ECD) test increased, whereas their failure strain and IRHD hardness decreased. The hardness decreased further as the test site on the hose skin approached to the negative pole.

  • PDF

A Study on the Diesel Spray Evaporation and Combustion Characteristics in Constant Volume Chamber (정적연소실내의 디젤분무증발과 연소특성에 관한 연구)

  • Kim, S.H.;Kim, S.J.;Lee, M.B.;Kim, E.S.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.2 no.6
    • /
    • pp.102-109
    • /
    • 1994
  • As a fundamental study to apply high pressure injection system to direct injection diesel engine, fuel injection system and constant volume combustion chamber were made and the behaviors of evaporating spray with the variation of injection pressure and the ambient gas temperature were observed by using high speed camera, and the combusion characteristics with the variation of injection pressure and A/F ratio were analyzed. As injection pressure increases, spray tip penetration and spray angle increase and, as a results spray volume increases. This helps an uniform mixing of fuel and air. Spray liquid core length decreases as ambient gas temperature increases, while it decreases as injection pressure increases but the effect of ambient gas temperature is dorminant. As injection pressure increases, ignition delay is shortened and combustion rate being raised, maximum heat release rate increases. It become clear that High injection pressure has high level of potential to improve the performance of DI-diesel engine.

  • PDF

Development of Liquid Crystal Optic Modulation Based X-ray Dosimeter by Using CdS Sensor (CdS 센서를 이용한 액정 광변조 X-선 검출 시스템 개발)

  • Noh, Si-Cheol;Kang, Sang-Sik;Jung, Bong-Jae;Choi, Il-Hong;Kim, Hyun-Hee;Cho, Chang-Hoon;Park, Jun-Hong;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.357-361
    • /
    • 2011
  • In this study, the liquid-crystal optical modulation X-ray detection system using a CdS which is a family of II-IV compound semiconductor was proposed. The system consist of the detector, the signal processing part, the liquid-crystal driving parts, microcontroller, and I/O parts, and was designed to be suitable for miniaturization and portable. In addition, the system can measure a wide range X-ray by using the detecting range selection. In order to evaluate the performance of the proposed system, the CdS sensor's output characteristics were confirmed in accordance with changes of dose, and excellent correlation was determined. And also, the optical penetration ratio was discussed in accordance with changes of the applied voltage by measuring the change of the liquid-crystal in accordance with changes of the applied voltage. Through these results, the characteristics of the liquid-crystal optical modulation system such as the excellent reproducibility and the noise immunity were confirmed. And we considered that the CdS cell-based liquid-crystal optical modulated portable X-ray detection system could be applied to compact, low-cost, portable system.

Automatic Test Method of Sizing Degree by Analysis of Liquid Penetration and its Surface Behavior (액체 침투 특성과 표면 거동 분석을 이용한 사이즈도 자동측정법)

  • Lee, Ji-Young;Kim, Gyung-Chul;Kim, Chul-Hwan;Sheikh, M.I.;Park, Hyun-Jin;Kim, Sung-Ho;Sim, Sung-Woong;Cho, Hu-Seung
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.44 no.2
    • /
    • pp.18-28
    • /
    • 2012
  • This study was to develop a novel automatic system for measuring St$\ddot{o}$ckigt sizing degree and contact angle at a time. The conventional methods to measure sizing degree had serious problems in obtaining significant differences according to different dosages of a sizing agent, and moreover they disclosed unique limitation due to liquid types used and tester's subjectivity. However, the newly developed system could get reproducible results through total automation of all procedures including liquid dropping, image acquisition and measurement of both St$\ddot{o}$ckigt sizing degree and contact angle. For the St$\ddot{o}$ckigt sizing test, the automatic system could measure sizing degree with more definite differences according to different dosage of AKD, compared to the conventional method. For the contact angle test, the automatic system showed a similar trend to the conventional method but had smaller contact angles due to distortion of an image focus by a sheet curl than the conventional testing machine. The problem from the image out of focus due to specimen curl will be overcome with adopting a new specimen holder for the future system.

The preparation of skin analogue composition having the liquid crystalline structure and its cosmetic applications

  • Lee, Dong-Kyu;Jeong, Kwan-Young
    • Journal of the Korean Applied Science and Technology
    • /
    • v.30 no.2
    • /
    • pp.215-224
    • /
    • 2013
  • Recently, many cosmetic researchers have been focused on the development of high functional cosmetics including anti-wrinkle and whitening. In these studies, they couldn't afford to pay a deep attention to stable encapsulations for unstable materials and efficient drug deliveries for them. Particularly, in order to show a degree of instant effects as cosmetics, they can't also ignore moisturizing effect enough to satisfy customers just after applying and its maintenance by improving the function of skin barrier as well as above two effects. Therefore, skin analogue systems have attracted considerable attention in the view of structural and compositional similarity to intercellular membrane in stratum corneum. And, some models for skin analogue composition were developed to improve the function of skin barrier, stably encapsulate unstable materials such as retinol, vitamin B, C, E, etc., and control their skin penetration in order to show good effects as cosmetics. In this study, we suggest the new skin analogue model having the compositional similarity as well as conventional structural ones. Our skin analogue membrane(SAM) is mainly composed of ceramide/ cholesterol/phosphatidylcholin/fatty acids and its structural defects are compensated by including cholesterol amphiphile and controlling the ratio of ceramide/cholesterol. It was possible to confirm the formation of skin analogue membrane having highly-densed multilamella structure and compare them according to the change of each ratio with a polarized microscope, X-ray diffraction. More detaily, we observed their structures with a electron microscope(TEM). Finally, we dispersed them in excess of continuous water phase, observed the formation of maltese-cross liquid crystalline and measured the efficiency of drug deliveries and moisturizing effects.

Study of hydrodynamics and iodine removal by self-priming venturi scrubber

  • Jawaria Ahad;Talha Rizwan ;Amjad Farooq ;Khalid Waheed ;Masroor Ahmad ;Kamran Rasheed Qureshi ;Waseem Siddique ;Naseem Irfan
    • Nuclear Engineering and Technology
    • /
    • v.55 no.1
    • /
    • pp.169-179
    • /
    • 2023
  • Filtered containment system is a passive safety system that controls the over-pressurization of containment in case of a design-based accidents by venting high pressure gaseous mixture, consisting of air, steam and radioactive particulate and gases like iodine, via a scrubbing system. An indigenous lab scale facility was developed for research on iodine removal by venturi scrubber by simulating the accidental scenario. A mixture of 0.2 % sodium thiosulphate and 0.5 % sodium hydroxide, was used in scrubbing column. A modified mathematical model was presented for iodine removal in venturi scrubber. Improvement in model was made by addition of important parameters like jet penetration length, bubble rise velocity and gas holdup which were not considered previously. Experiments were performed by varying hydrodynamic parameters like liquid level height and gas flow rates to see their effect on removal efficiency of iodine. Gas holdup was also measured for various liquid level heights and gas flowrates. Removal efficiency increased with increase in liquid level height and gas flowrate up to an optimum point beyond that efficiency was decreased. Experimental results of removal efficiency were compared with the predicted results, and they were found to be in good agreement. Maximum removal efficiency of 99.8% was obtained.

Skin Barrier Function Enhancement Effect about Ceramide Liquid Crystal Emulsion: Similar Ratio of Skin Lipid Composition (피부 지질 조성 모사 Ceramide 액정 에멀젼의 피부 장벽 강화 효과 확인에 관한 연구)

  • Han, Ji Hye;Lee, Ju Yeon;Lee, Kwan Hyoung;Kim, Hee Sun;Park, Chang Yeol;Maeng, Ji Hye;So, Ji Min;Nam, Gae Won;Kim, Sang Chul
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.47 no.1
    • /
    • pp.49-56
    • /
    • 2021
  • In this study, a liquid crystal emulsion with a composition ratio similar to the skin lipid composition was manufactured using ceramide, glycolipids, cholesterol, and fatty acids, and a polarized microscope was used to identify liquid crystal particles in the formulation, and a cryso-SEM was used to confirm the formation of a multilayer structure. The above samples were stored at room temperature for one month and the liquid crystal structure was continuously maintained through microscopic observation. In addition, a cream composition containing liquid crystal emulsion was manufactured, and the efficiency of ceramide skin penetration was confirmed using three-dimensional artificial skin. Clinical trials were conducted using the cream composition and the results of clinical trials on skin barrier improvement were confirmed by measuring skin moisture retention (skin hydration) and transepidermal water loss (T EWL) of subjects compared to general emulsion.

Effect of Nozzle Hole Number on Fuel Spray and Emission Characteristics of High Pressure Diesel Injector (고압 디젤 인젝터 노즐 홀 수가 연료 분무 및 배기 특성에 미치는 영향)

  • Chon, Mun Soo
    • Journal of ILASS-Korea
    • /
    • v.17 no.4
    • /
    • pp.210-215
    • /
    • 2012
  • This paper This paper presents effect of nozzle hole number on spray characteristics and engine performance. Experiments were conducted to measure spray penetration and SMD distributions using a spray visualization system and PDPA (phase Doppler particle analyzer) system. In addition, engine performance and emission characteristics were measured using a single cylinder engine and emssion measurement systems. Results showed that 8-hole-injector exhibits improved spray performances. Furthermore, soot emission was decreased with 8-hole-injector, compared to that of 6-hole-injector.