• 제목/요약/키워드: Liquid flow measurement

검색결과 242건 처리시간 0.029초

스월 인젝터에서의 액막두께 측정에 관한 연구 (Liquid film Thickness Measurement for a Swirl Injector)

  • 김성혁;김동준;윤영빈
    • 한국추진공학회지
    • /
    • 제10권2호
    • /
    • pp.70-77
    • /
    • 2006
  • 정확한 액막두께 측정을 위해 전기전도도를 이용한 장치를 제작하였다 정밀한 calibration을 통해 측정을 수행하였으며 기존의 이론식 및 다른 측정 방법을 이용한 결과와 비교해 보았을 때 정확성이 입증되었다. 시간에 따른 액막두께 변화를 통해 내부 유동의 변화 및 안정성도 살펴볼 수 있었다. 정확한 측정을 통해 기하학적 형상에 따른 액막두께의 경향성도 파악할 수 있었다.

Numerical analysis of the venturi flowmeter in the liquid lead-bismuth eutectic circuit after long-term operation

  • Zhichao Zhang;Rafael Macian-Juan;Xiang Wang
    • Nuclear Engineering and Technology
    • /
    • 제56권3호
    • /
    • pp.1081-1090
    • /
    • 2024
  • The liquid Lead-bismuth eutectic is used as the coolant for Gen-IV reactor concepts. However, due to its strong corrosive and high operating temperature, it is difficult to accurately measure the flow rate in long-term operating conditions. Venturi flowmeter is a simple structured flowmeter, which plays a very important role in the flow measurement of high-temperature liquid metals, especially since the existing flowmeters are difficult to be competent. It has the advantages of easy maintenance and stable operation. Therefore, it is necessary to study the operating conditions of the venturi flowmeter under high-temperature conditions. This work performs a series of simulations of the fluid-solid interaction between the flow liquid metal and venturi flowmeter with COMSOL software, including the dimensional sensitivity analysis of the venturi flowmeter to explore the most suitable structure and parameters for liquid heavy metal, the sensitivity analysis of the geometric parameters of the venturi tube on the varying conditions. It shows that when the contraction angle of the venturi flowmeter is 33°, the diffusion angle is 13°, the diameter of the throat is 8 mm, and the temperature of the lead-bismuth eutectic is 733.15 K, it is most suitable for the measurement in the lead-bismuth circuit.

TLC와 컬러화상처리를 이용한 자동차 실내 환기유동의 온도장 측정 (Temperature Field Measurement of Ventilation Flow in a Vehicle Interior)

  • 윤정환;이상준;김기원
    • 한국자동차공학회논문집
    • /
    • 제5권1호
    • /
    • pp.120-128
    • /
    • 1997
  • The variations of the temperature field in a passenger compartment were measured by using a HSI true color image processing system and TLC(Thermochromic Liquid Crystal) solution. This temperature measurement technique was proved to be useful for analyzing the ventilation flow. The flow field in the passenger compartment was visualized using a particle streak method with pulsed laser light sheet. The temperature field and flow field in the passenger copartment were affected significantly by the ventilation mode. The panel-vent mode heating had shorter elapse time to reach a uniform temperature than the foot-vent mode under the same ventilation condition and nonuniformity inside the passenger compartment could be minimized effectively by using the bilevel heating mode. The temperature increase rate in the rear passenger compartment was iower than the front compartment, especially in the vicinity of the rear seat occupants' knee level.

  • PDF

Experimental study on air-water countercurrent flow limitation in a vertical tube based on measurement of film thickness behavior

  • Wan, Jie;Sun, Wan;Deng, Jian;Pan, Liang-ming;Ding, Shu-hua
    • Nuclear Engineering and Technology
    • /
    • 제53권6호
    • /
    • pp.1821-1833
    • /
    • 2021
  • The gas-liquid counter-current flow limitation (CCFL) is closely related to efficient and safety operation of many equipment in industrial cycle. Air-water countercurrent flow experiments were performed in a tube with diameter of 25 mm to understand the triggering mechanism of CCFL. A parallel electrode probe was utilized to measure film thickness whereby the time domain and frequency domain characteristics of liquid film was obtained. The amplitude of the interface wave is small at low liquid flow rate while it becomes large at high liquid flow rate after being disturbed by the airflow. The spectral characteristic curve shows a peak-shaped distribution. The crest exists between 0 and 10 Hz and the amplitude decreases with the frequency increase. The analysis of visual observation and characteristic of film thickness indicate that two flooding mechanisms were identified at low and high liquid flow rate, respectively. At low liquid flow rate, the interfacial waves upward propagation is responsible for the formation of CCFL onset. While flooding at high liquid flow rate takes place as a direct consequence of the liquid bridging in tube due to the turbulent flow pattern. Moreover, it is believed that there is a transition region between the low and high liquid flow rate.

PIV 법을 이용한 기포유동에 관한 연구 (A Study on Bubbly Flow using PIV Measurement)

  • 배대석;권오봉
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제25권4호
    • /
    • pp.898-903
    • /
    • 2001
  • The particle image velocimetry with liquid crystal tracers is used for visualizing and analysis of the bubbly flow in a vertical temperature gradient. This method allows simultaneous measurement of velocity and temperature field at a given instant of time Quantitative data of velocity were obtained by applying the MQD technique to visualized image. The paper describes the method, and presents the transient velocity patterns of bubbly flow.

  • PDF

전자기 토모그래피를 이용한 액체 금속 속도장 측정 (Measurement of velocity Pronto in Liquid Metal Flow Using Electromagnetic Tomography)

  • 안예찬;김무환;최상호
    • 대한기계학회논문집B
    • /
    • 제28권10호
    • /
    • pp.1271-1278
    • /
    • 2004
  • In order to measure non-intrusively velocity profile in liquid metal flow, a modified electromagnetic flowmeter was designed, which was based on electromagnetic tomography technique. Under the assumption that flow is fully-developed, axisymmetric and rectilinear, the velocity profile was reconstructed after the flowmeter equation, the first kind of Fredholm integration equation, was linearized. In reconstruction process Tikhonov regularization method with regularization parameter was used. The reconstructed velocity profile had the nearly same as turbulent flow profile which was approximately represented as log law. In addition, flowmeter output fur a fixed magnet rotation angle was linearly proportional to flow rate. When magnet rotation angle was 54$^{\circ}$, axisymmetric weight function was nearly uniform so that the flowmeter gives a constant signal for any fully-developed, axisymmetric and rectilinear profile with a constant flow rate.

전자기 토모그래피를 이용한 액체 금속 속도장 측정 (Measurement of Velocity Profile in Liquid Metal Flow Using Electromagnetic Tomography)

  • 최상호;안예찬;김무환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1749-1754
    • /
    • 2004
  • In order to measure non-intrusively velocity profile in liquid metal flow, a modified electromagnetic flowmeter was designed, which was based on electromagnetic tomography technique. Under the assumption that flow is fully-developed, axisymmetric and rectilinear, the velocity profile was reconstructed after the flowmeter equation, the first kind of Fredholm integration equation, was linearized. In reconstruction process Tikhonov regularization method with regularization parameter was used. The reconstructed velocity profile had the nearly same as turbulent flow profile which was approximately represented as log law. In addition, flowmeter output for a fixed magnet rotation angle was linearly proportional to flow rate. When magnet rotation angle was $54^{\circ}$, axisymmetric weight function was nearly uniform so that the flowmeter gives a constant signal for any fully-developed, axisymmetric and rectilinear profile with a constant flow rate.

  • PDF

수직상향 기체 주입에 따른 기포 및 액상의 유동분석 (Flow Analysis of Bubble and Liquid Phase by Vertical Upward Gas Injection)

  • 서동표;오율권
    • 설비공학논문집
    • /
    • 제15권9호
    • /
    • pp.727-732
    • /
    • 2003
  • In the present study, a PIV measurement and image processing technique were applied in order to investigate the flow characteristics in the gas injected liquid bath. The circulation of liquid was induced by upward bubble flow. Due to the centrifugal force, the flow was well developed near both wall sides than in the center of a bath. The vortex flow irregularly repeated generation and disappearance which helped to accelerate the mixing process. The bubble rise velocity in the bottom region was relatively lower than in the upper region because the energy generated by bubbles' behavior in the region near the nozzle was almost converted into kinetic energy But bubble rise velocity increases with the increase of the axial distance since kinetic energy of rising bubbles is added to buoyancy force. In conclusion, the flow increased bubble rise velocity and the flow of the bottom region became more active.

A Study on Bubbly flow using PIV Measurement

  • Bae, Dae-Seok
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2000년도 추계학술대회 논문집(Proceeding of the KOSME 2000 Autumn Annual Meeting)
    • /
    • pp.50-54
    • /
    • 2000
  • The partical-image-velocimetry with liquid crystal tracers is used for visualizing and analysis of the bubbly flow in a vertical temperature gradient. This method allows simultaneous measurement of velocity and temperature flow fields at a given instant of time. Quantitative data of velocity were obtained by applying the MQD technique to visualized image. The paper describes the method, and presents the transient velocity patterns of bubbly flow.

  • PDF

기체-액체 이젝터 유동의 가시화와 광섬유 탐침에 의한 기포분율 측정 (Visualization of Gas/liquid Ejector Flow and Void Fraction Measurement using Fiber Optic Probe)

  • 최성환;지호성;김경천
    • 한국가시화정보학회지
    • /
    • 제11권1호
    • /
    • pp.34-40
    • /
    • 2013
  • Gas/liquid two-phase ejector is a device without moving parts, in which liquid is used to drive gas of a low-pressure source. In this paper, the hydrodynamic characteristics of a vertical down type two-phase ejector were studied using an air-water loop system. Entrained air flow rates were measured with inlet and outlet pressures of the ejector with varying water flow rate. Homogeneous bubbly flows in the discharge pipe were confirmed by the high speed flow visualization method. Quantitative measurements of void fraction were made using a newly developed fiber optic probe system.