Browse > Article
http://dx.doi.org/10.1016/j.net.2020.12.019

Experimental study on air-water countercurrent flow limitation in a vertical tube based on measurement of film thickness behavior  

Wan, Jie (Key Laboratory of Low-Grade Energy Utilization Technologies and Systems, Ministry of Education, Chongqing University)
Sun, Wan (Key Laboratory of Low-Grade Energy Utilization Technologies and Systems, Ministry of Education, Chongqing University)
Deng, Jian (Science and Technology on Reactor System Design Technology Laboratory, NPIC)
Pan, Liang-ming (Key Laboratory of Low-Grade Energy Utilization Technologies and Systems, Ministry of Education, Chongqing University)
Ding, Shu-hua (Science and Technology on Reactor System Design Technology Laboratory, NPIC)
Publication Information
Nuclear Engineering and Technology / v.53, no.6, 2021 , pp. 1821-1833 More about this Journal
Abstract
The gas-liquid counter-current flow limitation (CCFL) is closely related to efficient and safety operation of many equipment in industrial cycle. Air-water countercurrent flow experiments were performed in a tube with diameter of 25 mm to understand the triggering mechanism of CCFL. A parallel electrode probe was utilized to measure film thickness whereby the time domain and frequency domain characteristics of liquid film was obtained. The amplitude of the interface wave is small at low liquid flow rate while it becomes large at high liquid flow rate after being disturbed by the airflow. The spectral characteristic curve shows a peak-shaped distribution. The crest exists between 0 and 10 Hz and the amplitude decreases with the frequency increase. The analysis of visual observation and characteristic of film thickness indicate that two flooding mechanisms were identified at low and high liquid flow rate, respectively. At low liquid flow rate, the interfacial waves upward propagation is responsible for the formation of CCFL onset. While flooding at high liquid flow rate takes place as a direct consequence of the liquid bridging in tube due to the turbulent flow pattern. Moreover, it is believed that there is a transition region between the low and high liquid flow rate.
Keywords
Flooding; Interface wave; Film thickness; Experimental results;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Y. Sudo, Mechanism and effects of predominant parameters regarding limitation of falling water in vertical countercurrent two-phase flow, J. Heat Tran. 118 (3) (1996) 715.   DOI
2 Deendarlianto, A. Ousaka, A. Kariyasaki, T. Fukano, Investigation of liquid film behavior at the onset of flooding during adiabatic counter-current air-water two-phase flow in an inclined pipe, Nucl. Eng. Des. 235 (21) (2005) 2281-2294.   DOI
3 E.A. Dukler, L. Smith, Two Phase Interactions in Counter-current Flow: Studies of the Flooding Mechanism, University of Houston, TX (USA), 1977. NUREG/CR-0617.
4 C.E. Lacy, A.E. Dukler, Flooding in vertical tubes-I. Experimental studies of the entry region, Int. J. Multiphas. Flow 20 (2) (1994) 219-233.   DOI
5 E.I.P. Drosos, S.V. Paras, A.J. Karabelas, Counter-current gas-liquid flow in a vertical narrow channel-Liquid film characteristics and flooding phenomena, Int. J. Multiphas. Flow 32 (1) (2006) 214-224.
6 O.L. Pushkina, Y.L. Sorokin, Breakdown of liquid film motion in vertical tubes, Heat Tran. Sov. Res. 1 (1969) 56-64.
7 K.S. Chung, C.P. Liu, C.L. Tien, Looding in two-phase counter-current flows-II: experimental investigation, Physico Chemical Hydrodynamics 1 (1980) 209-220.
8 D.M. Maron, A.E. Dukler, New concepts on the mechanisms of flooding and flow reversal phenomena, Lett. Heat Mass Tran. 8 (6) (1981) 453-463.   DOI
9 D.M. Maron, A.E. Dukler, Flooding and upward film flow in vertical tubes-II. Speculations on film flow mechanisms, Int. J. Multiphas. Flow 10 (5) (1984) 599-621.   DOI
10 J.C. Sacramento, P.J. Heggs, The role of flooding in the design of vent and reflux condensers, Appl. Therm. Eng. 29 (7) (2009) 1338-1345.   DOI
11 A.G. Cetinbudaklar, G.J. Jamson, The mechanism of flooding in vertical countercurrent two-phase flow, Chem. Eng. Sci. 24 (1969) 1669-1680.   DOI
12 Y. Zvirin, R.B. Duffey, K.H. Sun, On the derivation of a countercurrent flooding theory, in: ASME Winter Annual Meeting, New York, 1979.
13 T. Ueda, S. Suzuki, Behavior of liquid films and flooding in counter-current two-phase flow : 2nd report, flow in annuli and rod bundles, Transactions of the Japan Society of Mechanical Engineers 44 (377) (1978) 174-182.   DOI
14 C. Pena-Monferrer, G. Monr ~ os-Andreu, S. Chiva, R. Martinez-Cuenca, J.L. Munoz-Cobo, A CFD-DEM solver to model bubbly ~ flow. Part I: model development and assessment in upward vertical pipes, Chem. Eng. Sci. 176 (2018) 524-545.   DOI
15 S. Al Issa, R. Macian-Juan, Experimental investigation and CFD validation of countercurrent flow limitation (CCFL) in a large-diameter PWR hot-leg geometry, J. Nucl. Sci. Technol. 53 (5) (2016) 647-655.   DOI
16 G. Zabaras, A.E. Dukler, D. Moalem-Maron, Vertical upward cocurrent gasliquid annular flow, AIChE J. 32 (5) (1986) 829-843.   DOI
17 Irfan Khan, Mingjun Wang, Yapei Zhang, Wenxi Tian, Guanghui Su, Suizheng Qiu, Two-phase bubbly flow simulation using CFD method: a review of models for interfacial forces, Prog. Nucl. Energy 125 (2020) 103360.   DOI
18 Y. Taitel, D. Barrnea, A.E. Dukler, A film model for the prediction of flooding and flow reversal for gas-liquid flow in vertical tubes, Int. J. Multiphas. Flow 8 (1) (1982) 1-10.   DOI
19 K.W. Mcquillan, P.B. Whalley, G.F. Hewitt, Flooding in vertical two-phase flow, Int. J. Multiphas. Flow 11 (6) (1985) 741-760.   DOI
20 A.S.E.P. Semenov, Hydraulic resistance in two-phase flow, Int. Chem. Eng. 7 (1967) 59-63.
21 B. Wu, M. Firouzi, T.E. Rufford, B. Towler, Characteristics of counter-current gas-liquid two-phase flow and its limitations in vertical annuli, Exp. Therm. Fluid Sci. 109 (2019) 109899.   DOI
22 M. Vijayan, S. Jayanti, A.R. Balakrishnan, Effect of tube diameter on flooding, Int. J. Multiphas. Flow 27 (2001) 797-816.   DOI
23 A. Badarudin, Deendarlianto Indarto, A. ASetyawan, Characteristics of the air-water counter current two-phase flow in a 1/30 scale of pressurized water reactor (PWR): interfacial behavior and CCFL data, AIP Conference Proceedings 1737 (2016), 040015.
24 C.J. Shearer, J.F. Davidson, The investigation of a standing wave due to gas blowing upwards over a liquid film; its relation to flooding in wetted-wall columns, J. Fluid Mech. 22 (2) (1965) 321-335.   DOI