• 제목/요약/키워드: Liquid Lens

Search Result 108, Processing Time 0.026 seconds

Evaluation of Contact Lens Care Regimens in Removing Tear Lipids on Silicone Hydrogel Lens (콘택트렌즈 관리방법에 의한 실리콘하이드로겔렌즈의 지방침전물 제거효과)

  • Kang, You-Sun;Lee, Koon-Ja;Ju, Eun-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.4
    • /
    • pp.347-353
    • /
    • 2010
  • Purpose: An in vitro study was conducted to compare the lipid cleaning efficacy of care solutions on balafilcon A silicone hydrogel (SiHy) lens. Methods: Lipid spoilation was performed by incubating balafilcon A SiHy lenses in phosphate buffered saline (PBS) containing oleic acid, oleic acid methyl ester and cholesterol. Spoiled contact lenses rinsed with PBS were cleaned with surfactant cleaner, alcohol containing cleaner and multipurpose solution (MPS) respectively and repetitive spoilation and cleaning was conducted up to 14 times. To observe the cleaning effect of ultrasonic wave on the lipid deposit, each spoiled lens was ultrasonicated and then compared with non-sonicated lens. Lipids deposit on the contact lenses was extracted by methanol:chloroform (1:1, v/v) solution. High performance liquid chromatography was used to analyze and quantify lipid deposit extracts. Results: The effectiveness of alcohol containing surfactant cleaner on the lipid deposits was better than that of surfactant cleaner and MPS, and the cleaning efficacy was significantly higher in the ultrasonic wave treated group. Lipid deposits were not removed completely by contact lens care solutions so that lipid deposits increased continuously and cumulatively. Conclusions: The cleaning efficacy of contact lens care solutions was not satisfactory to remove lipid deposits on the SiHy lens that new cleaning products specially designed for SiHy lenses are needed to develop.

A Geometrical Analysis Method of ELC Lens for The 3D Display for Optimum Design (3차원 영상출력을 위한 ELC 렌즈의 기하광학적 해석 방법 및 최적 설계)

  • Kim, Bong-Sik;Kim, Keon-Woo;Baik, Seung-Jo;Park, Woo-Sang
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.6
    • /
    • pp.457-461
    • /
    • 2013
  • In this paper, a novel method based on geometrical optics is proposed to calculate the optical characteristics of an electric field driven liquid crystal (ELC) lens. For an optimally designed ELC lens, effective refractive index is calculated and then ray tracing is carried out using Huygens' principle. From the results, the intensity distribution at the optimum viewing distance (OVD) is obtained. To confirm the validity of our work, the result is compared with that calculated by the extended Jones matrix method (EJMM). As a result, it turns out that the novel method provides more simple and rigorous simulation results than the EJMM.

Liquid Immersion Method for Determining the Refractive Index of a Lens by using the Murty Shearing Interferometer (층밀리기 간섭계를 이용한 렌즈 굴절률의 비파괴적 측정)

  • 이윤우;조현모;이인원
    • Korean Journal of Optics and Photonics
    • /
    • v.2 no.1
    • /
    • pp.7-12
    • /
    • 1991
  • A nondestructive technique for measuring the refractive index of a simple lens is described. The shearing interferornetric technique is used for determining the focal length of a lens by immersing it in various liquids. The lens itself acts as autocollimator and decollimator. An equation for the defocusing error has been theoretically deduced and experimentally verified. The wave aberration has also been investigated for the different values of the focal length.

  • PDF

The Difference of the Cleaning and Wettability-maintaining Efficacy of Lens Care Solution to RGP Lens (관리 용품에 따른 RGP 렌즈의 세척효과 및 습윤성 차이)

  • Kim, Myoung-Hea;Park, Mi-Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.1
    • /
    • pp.27-34
    • /
    • 2006
  • We investigated the question whether the efficacy of cleaning tear components on RGP lens and preserving the superior wettability of RGP lens depended on the different type of contact lens care system - RGP lens care solution, SCL care solution, combined solution both for SCL and RGP lens or saline solution. The removal efficacy of the deposited protein was examined by Lowry protein assay and Scanning Electro Microscope(SEM) and residual lipid concentration on RGP lens was determined by High Pressure Liquid Chromatology(HPLC). Wettability was assessed with an equilibrium water-in-air contact angle method. When cared by RGP lens solution, it was demonstrated that 62 percent out of the adhered protein on RGP lens were removed and the removal efficacy of RGP lens solution was not only 4 times than saline solution and the alternative but also higher twice than SCL solution. Contrarily, the SCL solution had the most excellent removal efficacy of the adhered protein on SCL. These results suggest that the cleaning efficacy is thought to be affected by the other factors like the viscosity of care solutions, which mutual contact between RGP lens and care solutions is on the increase due to the viscosity enhancer in RGP lens care solution. RGP lens solution had the greatest removing efficacy to cholesterol and the residual cholesterol concentration was decreased to 50%. It is significant for RGP lens to preserve the superior wettability which means the predictive value for comfortable wearing and it showed that the RGP lens solution offered the most excellent efficacy to maintain the surface wettability. Combined solution both for SCL and RGP lens had weak efficacy of cleaning and maintaining wettability for RGP lens compared to RGP lens care solution.

  • PDF

Integral Imaging System Enabling Enhanced Depth of Field Incorporating a Birefringent Liquid Crystal Lens Array (복굴절 특성을 갖는 액정 렌즈어레이를 이용한 깊이감이 향상된 집적영상 시스템)

  • Park, Chan-Kyu;Hwang, Yong-Seok;Lee, Sang-Shin
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.6
    • /
    • pp.394-399
    • /
    • 2008
  • An integral imaging system enabling enhanced depth of field by incorporating a pair of liquid-crystal (LC) lens arrays was proposed and demonstrated. The lens arrays exhibit two different refractive indexes depending on the light polarization. The proposed LC lens array I and II were implemented by depositing a ZLI-4119 LC and an E-7 LC, respectively, on top of a lens-array substrate in glass. When the two LC lens arrays were aligned appropriately, a birefringence was obtained for a specific light polarization in such a way that the incoming light sees different refractive indexes for them. As a result, the focal length associated with the imaging system utilizing the LC lens arrays was adaptively varied, thereby enhancing the depth of field for the image reconstruction. We have theoretically analyzed the proposed integral imaging system with the $LightTools^{(R)}$ to confirm that the focal length could be adjusted with the help of the birefringent lens array. Finally the proposed imaging system successfully reconstructed the objects. The birefringent lens array employing the ZLI-4119 LC produced a real image with the focal length of 680 mm, while the other using the E-7 LC yielded a virtual image with the focal length of -29 mm.

Design and manufacture of horn lens antennas of 80 GHz MM wave FMCW radar for cryogenic fluids level measurement

  • Jeon, S.M.;Mun, J.M.;Lee, S.C.;Sim, K.D.;Kim, S.H.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.24 no.1
    • /
    • pp.29-33
    • /
    • 2022
  • Recently, development of a cryogenic fluids storage tank for storing or transporting liquid hydrogen is actively in progress. In cryogenic fluids storage tanks, hydrogen evaporates due to the extreme temperature difference inside and outside the tank. As the mass of the cryogenic fluids changes with continuous vaporization, the fluids level also changes. Therefore, there is need for a method of accurately measuring the level change in the storage tank. In the case of general cryogenic fluids, it is difficult to accurately measure the level because the dielectric constant is very low. As a method of measuring cryogenic fluids level with low dielectric constant, it can be used an Millimeter wave (MM wave) FMCW radar sensor. However, the signal sensitivity is very weak and the level accuracy is poor. In this paper, the signal sensitivity is improved by designing the horn lens antenna of the existing 80 GHz FMCW radar sensor. Horn lens antenna is fabricated by FDM/SLA type 3D printer according to horn and lens characteristics. The horn is used to increase the signal gain and the lens improves the signal straightness. This makes it possible to measure the level of cryogenic fluids with a low dielectric constant.

Strain-induced islands and nanostructures shape transition's chronology on InAs (100) surface

  • Gambaryan, Karen M.;Aroutiounian, Vladimir M.;Simonyan, Arpine K.;Ai, Yuanfei;Ashalley, Eric;Wang, Zhiming M.
    • Advances in nano research
    • /
    • v.2 no.4
    • /
    • pp.211-217
    • /
    • 2014
  • The self-assembled strain-induced sub-micrometric islands and nanostructures are grown from In-As-Sb-P quaternary liquid phase on InAs (100) substrates in Stranski-Krastanow growth mode. Two samples are under consideration. The first sample consists of unencapsulated islands and lens-shape quantum dots (QDs) grown from expressly inhomogeneous liquid phase. The second sample is an n-InAs/p-InAsSbP heterostructure with QDs embedded in the p-n junction interface. The morphology, size and shape of the structures are investigated by high-resolution scanning electron (SEM) and transmission electron (TEM) microscopy. It is shown that islands, as they decrease in size, undergo shape transitions. Particularly, as the volume decreases, the following succession of shape transitions are detected: sub-micrometric truncated pyramid, {111} facetted pyramid, {111} and partially {105} facetted pyramid, completely unfacetted "pre-pyramid", hemisphere, lens-shaped QD, which then evolves again to nano-pyramid. A critical size of $5{\pm}2nm$ for the shape transformation of InAsSbP-based lens-shaped QD to nano-pyramid is experimentally measured and theoretically evaluated.

Illumination system design for the liquid crystal display projector using fly-eye lenses (Fly-eye lens를 사용하는 액정 projector용 조명 광학계의 설계)

  • 류재명;조재흥;정진호;이종진
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.3
    • /
    • pp.173-181
    • /
    • 2002
  • The principle of an illumination system including fly-eyes lenses for a liquid crystal display (LCD) projector with 3-panels was presented and its optical system was designed by using the OSLO (premium edition 6.1) optical system design program. Two panels of the illumination system are well aligned for so that the illumination path length is the same, and the third panel has a longer pass length than the others. The two illumination types with the same or different illumination path lengths were derived by using the paraxial ray design method. Refraction powers and positions of each lens were analytically determined by the method, and the damped least square method was utilized to obtain the optimized uniform illumination system.

A study on liquid crystal-based electrical polarization control technology for polarized image monitoring device (편광 영상감시 장치를 위한 액정 기반 전기적 편광 조절 기술 연구)

  • Ahn, Hyeon-Sik;Lim, Seong-Min;Jang, Eun-Jeong;Choi, Yoonseuk
    • Journal of IKEEE
    • /
    • v.26 no.3
    • /
    • pp.416-421
    • /
    • 2022
  • In this study, we present a fully automated system that combines camera technology with liquid crystal technology to create a polarization camera capable of detecting the partial linear polarization of light reflected from an object. The use of twisted nematic (TN) liquid crystals that electro-optically modulate the polarization plane of light eliminates the need to mechanically rotate the polarizing filter in front of the camera lens. Images obtained using these techniques are imaged by computer software. In addition, liquid crystal panels have been produced in a square shape, but many camera lenses are usually round, and lighting or other driving units are installed around the lens, so space is optimized through the application of a circular liquid crystal display. Through the development of this technology, an electrically switchable and space-optimized liquid crystal polarizer is developed.

Development of a Contact Angle Measurement Method Based Upon Geometry (기하학적 원리에 의거한 접촉각의 측정)

  • 김동수;표나영;서승희;최우진;권영식
    • Resources Recycling
    • /
    • v.7 no.5
    • /
    • pp.41-45
    • /
    • 1998
  • A Hew way of contact angle measurement is derived based on simple geometrical calculation. Without using complicated contact angle measurement instrument. Just measuring the diameter and height of liquid lens made it possible to calculate the contact angle value with a reasonable reliability. To validate the contact angle value obtained by this method, contact angle of the same liquid lens is measured using conventional goniometer and it is verified that two values are nearly same within the limit of observational error.

  • PDF