• Title/Summary/Keyword: Liquid Height

Search Result 407, Processing Time 0.025 seconds

Cryopreservation of Scapharca broughtonii (Schrenck) Sperm (피조개, Scapharca broughtonii (Schrenck) 정자의 동결보존)

  • Rha, Sung-Ju;Han, Kyeong-Ho;Choi, Myeong-Rak;Kho, Kang-Hee
    • The Korean Journal of Malacology
    • /
    • v.26 no.4
    • /
    • pp.255-260
    • /
    • 2010
  • This study was conducted to investigate protocol standardization for spermatozoa cryopreservation of the Scapharca broughtonii (Schrenck). Among the freezing rates, freezing at a height of 2 cm above liquid nitrogen surface for 5 minute gave higher activity and survival rate. Among the various diluents, Ringer's solution was the best for S. broughtonii sperm cryopreservation. The suitability of cryoprotectants dimethylsulfoxide (DMSO), dimethylacetamide (DMA), glycerol and methanol were tested against three freezing rates. DMSO gave significantly higher activity and survival rates than others.

The Development of UV-IR Combination Flame Detector (UV-IR 복합형 화재감지장치 개발)

  • 이복영;권오승;정창기;박상태
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.1
    • /
    • pp.1-8
    • /
    • 2001
  • All objects emit thermal radiation and this radiation is the basis of the techniques used to detect flames. The usual phenomena occurring in the initial stage of the fire are generally invisible products of a combustion and visible smoke. Liquid or gaseous materials do not undergo a smoldering stage so that fires develop very rapidly. Also, the heat generated by the initial flames is usually not sufficient to activate a heat detector. In this case the most effective criterion for automatic fire detection is the flame. According to the fire regulation of korea, the compulsory standard provided that a flame detector shall be installed in a place that the attachment height of detector is higher than 20 m, chemical plants, hangar, refinery, etc.. The results of the research and development are discriminated between a flame and other radiant emitters, developed a UV detector tube contains an inert gas which absorbs UV radiation, developed PZT pyroelectric element is based on the use of photovoltanic cell, developed IR band-pass filter that only allow a 4.3 $\mu\textrm{m}$ radiation wavelength to reach the sensors and developed UV-IR combination flame detector combined into a single detection device.

  • PDF

Perilla Leaf Fertilization Effect of Fertilizer by Chlorella and Seafood By-product Fermentation (클로렐라 및 수산부산물 발효 비료의 들깻잎 시비효과)

  • Ann, Seoung-Won;Lee, Jae-Myun;Cho, Yong-Koo
    • Journal of Environmental Science International
    • /
    • v.29 no.4
    • /
    • pp.423-434
    • /
    • 2020
  • The effects of amino acid and/or urea liquid fertilizer application on the growth and phytochemicals of Perilla leaves were summarized as follows; The fresh weight of the perilla leaves was in the order of CF, CL, KLF, and control, and 39.7 g, 37.4 g, 36.5 g and 32.3 g were measured. The plant height increased by 71.6 cm in the CF treatment than in the control(54.6 cm). The number of nodes was 14.3 node in CF treatment and 19% more than control(12 node). The vitamin C content tends to be increased by fertilizing the amino acid solution in the perilla leaf. The components of polyvalent unsaturation of n-6 origin were measured in CF treatment, KLF treatment, and control in 10.19 mg, 10.18 mg, and 9.38 mg per 100 g, respectively. Glutamic acid, aspartic acid, leucine, arginine, alanine and lysin were contained in perilla leaf amino acid. Glutaminic acid content was found to be 455.1 mg, 495.6 mg, and 478.8 mg in the control, KLF and CF treatment per 100 g, respectively. Effective nutrition management using amino acid fertilizer optimizes crop yield and profitability, it is important to reduce the negative environmental risks of using fertilizer.

Study on Adsoption Characteristics of Tharonil on Activated Carbon Fixed Bed (활성탄 고정층에 대한 Tharonil의 흡착특성에 관한 연구)

  • Lee, Jong-Jip;Yu, Yong-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.1
    • /
    • pp.54-60
    • /
    • 2002
  • To obtain the breakthrough characteristics for the design of fixed bed adsorption plant, adsorption experiment on granular activated carbon was performed with tharonil in the fixed bed. The pore diffusivity and surface diffusivity of tharonil estimated by the concentration-time curve and adsorption isotherm were $D_s=2.825{\times}10^{-9}cm^2/s,\;D_p=1.26{\times}10^{-5}cm^2/s$, respectively. From comparison of the pore diffusivity and surface diffusivity, it was found that surface diffusion was controlling step for intrapaticle diffusion. The breakthrough curve predicted by constant pattern-linear driving force model were shown to agree with the experimental results. The surface diffusivity and film mass transfer coefficient had no effect on the theoretical breakthrough curve but the adsorption isotherm had fairly influence on it. Appearance time of breakthrough curve is faster with the increase flow rate and inflow concentration of liquid. The utility of granular activated carbon is enhanced with the increase of bed height and with the decrease of inflow rate.

Drop Performance Test of Control Rod Assembly for Prototype Gen-IV Sodium-cooled Fast Reactor (PGSFR 제어봉집합체 낙하성능시험)

  • Lee, Young Kyu;Kim, Hoe Woong;Lee, Jae Han;Koo, Gyeong Hoi;Kim, Jong Bum;Kim, Sung Kyun
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.12 no.1
    • /
    • pp.134-140
    • /
    • 2016
  • The Control Rod Assembly (CRA) controls the reactor power by adjusting its position in the reactor core during normal operation and should be quickly inserted into the reactor core by free drop under scram condition to shut down chain reactions. Therefore, the drop time of the CRA is one of important factors for the safety of the nuclear reactor and must be experimentally verified. This study presents the drop performance test of the CRA which has been conceptually designed for the Proto-type Generation IV Sodium-cooled Fast Reactor. During the test, the CRA was free dropped from a height of 1 m under different flow rate conditions and its drop time was measured. The results showed that the drop time of the CRA increased as the flow rate increased; the average drop times of the CRA were approximately 1.527 seconds, 1.599 seconds and 1.676 seconds at 0%, 100% and 200% of design flow rates, respectively.

Consideration for IMO Type C Independent Tank Rule Scantling Process and Evaluation Methods (IMO C형 독립탱크의 설계치수 계산과정 및 평가방법에 대한 고찰)

  • Heo, Kwang-hyun;Kang, Won-sik;Park, Bong-qyun
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2017.10a
    • /
    • pp.93-104
    • /
    • 2017
  • IMO type C independent tank is one of the cargo containment system specified on IGC code. It is normally adopted for small and medium size liquefied gas carrier's cargo containment system and it can be applied to fuel tank of LNG fueled vessel. This study focuses on rule scantling process and evaluation methods in early design stage of type C independent tank. Actual design results of 22K LPG/Ammonia/VCM carrier's No.2 cargo tank are demonstrated. This paper presents the calculation methods of design acceleration and liquid height for internal design pressure as defined on IGC code. And this paper shows the applied results of classification rules about shell thickness requirement and buckling strength. Additionally this paper deals with evaluation methods of structural strength and cumulative fatigue damage using FE analysis.

  • PDF

Effect of Digestion Temperature on the Solid-Liquid Separation Characteristics of Anaerobically Digested Municipal Sewage Sludge (도시하수슬러지의 혐기성소화시 고액분리 특성에 미치는 소화온도의 영향)

  • Han, Jang Woon;Chang, Duk;Kim, Sung Soon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.8 no.1
    • /
    • pp.1-8
    • /
    • 1994
  • Laboratory experiments were conducted to investigate the effect of digestion temperature on the settleability and dewaterability of anaerobically digested sludge. The digesters were operated at a hydraulic retention time of 20 days with a loading rate of 0.63~0.66kg volatile solids per cubic meter per day at the temperature of $35^{\circ}C$ and $55^{\circ}C$. A mixed primary and secondary municipal sludge was used as a feed. The interface height of the sludge during settling test was recorded to identify settleability. As a measure of dewaterability of the sludge, specific resistance and capillary suction time were also measured with and without chemical conditioning. Higher digestion efficiency was obtained at $55^{\circ}C$ than $35^{\circ}C$. However, the settleability and dewaterability of the sludge at $35^{\circ}C$ were quite higher than those of the sludge digested at $55^{\circ}C$. The optimum dosages of ferric chloride for sludge conditioning were 0.4% and 0.6% at $35^{\circ}C$ and $55^{\circ}C$, respectively. The filtrate COD of the sludge digested at $55^{\circ}C$ was higher than at $35^{\circ}C$, which means that poor dewaterability of the sludge result in high filtrate COD.

  • PDF

Coincidence summing correction for a voluminous 152Eu source

  • Yoon, Eun Taek;Kang, Min Young;Kim, In Jung;Sun, Gwang Min;Choi, Hee-Dong
    • Nuclear Engineering and Technology
    • /
    • v.52 no.6
    • /
    • pp.1266-1270
    • /
    • 2020
  • A code is developed to correct for the coincidence summing effect in detecting a voluminous gamma source, and this code is applied to a152Eu standard source as a test case. The source is 1000 mL of liquid in a cylindrical shape. To calculate the coincidence summing effect, the cylindrical source is considered as 10(radial) × 8(height) sectional sources. For each sectional source, the peak efficiency and total efficiency are obtained by Monte Carlo simulation at each energy for 10 energies between 50 keV and 2000 keV. The efficiencies of each sector are then expressed as polynomials of gamma energy. To calculate the correction coefficients for the coincidence summing effect, the KORSUM code is used after modification. The magnitudes of correction are 4%-17% for the standard 152Eu source measured in this study. The relative deviation of 4.7% before the coincidence correction is reduced to 0.8% after the correction is applied to the efficiency based on the measured gamma line. Hence, this study has shown that a new method has been developed that is applicable for correcting the coincidence effect in a voluminous source, and the method is applied to the measured data of a standard 152Eu cylinder source.

Computational Analysis for Improving Internal Flow of High Pressure Methanol Steam Reformer Pressure Vessel (고압형 메탄올 수증기 개질기 압력용기의 내부 유동 개선을 위한 전산 해석)

  • YU, DONGJIN;JI, HYUNJIN;YU, SANGSEOK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.31 no.5
    • /
    • pp.411-418
    • /
    • 2020
  • A reformer is a device for producing hydrogen used in fuel cells. Among them, methanol steam reformer uses methanol as fuel, which is present as a liquid at room temperature. It has the advantage of low operating temperature, high energy density, and high hydrogen production. The purpose of this study is to improve the internal flow of the pressure vessel when a bundle of methanol steam reformer in the pressure vessel goes out to a single outlet. An analysis of equilibrium reaction to methanol steam reforming reaction was conducted using Aspen HYSYS® (Aspen Technology Inc., Bedford, USA), and based on the results, computational analysis was conducted using ANSYS Fluent® (ANSYS, Inc., Canonsburg, USA). For comparison of the results, the height of the pressure vessel, outlet diameter, and fillet was set as variables, and the optimum geometry was selected by comparing the effects of gravity and the amount of negative pressure.

Flat Fluorescent Lamp(EEL) and LCD TV Backlight Using EEL as a Light Source (면광원 램프 및 이를 이용한 LCD TV용 백라이트)

  • Park, Jong-Lee;Kim, Chung-Soo;Lim, Sung-Kyoo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.14 no.2 s.43
    • /
    • pp.1-8
    • /
    • 2007
  • A flat fluorescent lamp (FFL) was developed as a light source for LCD TV Backlight. The channels of FFL were realized by forming the flat glass at high temperature. The performance of the backlight with FFL was shown to improve by optimizing the FFL channel profile that has elliptical shape, 4.4 mm height and 1.4 mm sealing distance. In this paper, the brightness uniformity of LCD TV backlights was investigated by optical simulation of FFL channel profiles. The brightness of LCD TV using FFL with the optimized channel profile was shown to be $576\;cd/m^2$.

  • PDF