• Title/Summary/Keyword: Liquid Chromatography-tandem Mass Spectrometry

Search Result 400, Processing Time 0.031 seconds

Bioequivalence of LesacinTM Tablet to Jeil CravitTM Tablet (Levofloxacin 100 mg) by Liquid Chromatography- Electrospray Tandem Mass Spectrometry (LC-MS/MS를 이용한 제일크라비트정(레보플록사신 100 mg)에 대한 레사신정 100 mg의 생물학적 동등성)

  • Lee, Jin-Sung;Choi, Sang-Jun;Ryu, Ju-Hee;Seo, Ji-Hyung;Lee, Myung-Jae;Kang, Jong-Min;Tak, Sung-Kwon;Kang, Jin-Yang;Lee, Kyung-Tae
    • Journal of Pharmaceutical Investigation
    • /
    • v.38 no.4
    • /
    • pp.269-275
    • /
    • 2008
  • The purpose of the present study was to evaluate the bioequivalence of two levofloxacin tablets, Jeil $Cravit^{TM}$ tablet (Jeil Pharm. Co., Ltd., Korea, reference drug) and $Lesacin^{TM}$ tablet (Ilhwa. Co., Ltd., Korea, test drug), according to the guidelines of Korea Food and Drug Administration (KFDA). Twenty-four healthy male Korean volunteers received two tablets containing levofloxacin 200 mg in a $2{\times}2$ crossover study. There was a one-week washout period between the doses. Plasma concentrations of levofloxacin were monitored for over a period of 24 hr after administration by using a high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS). The area under the plasma concentration-time curve from time zero to 24 hr ($AUC_t$), maximum plasma drug concentration ($C_{max}$) and time to reach $C_{max}\;(T_{max})$ were complied from the plasma concentration-time data. Analysis of variance (ANOVA) test was utilized for the statistical analysis of the parameters using logarithmically transformed $AUC_t$ and $C_{max}$. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{max}$ ratio for $Lesacin^{TM}$/Jeil $Cravit^{TM}$ were $\log\;0.9527{\sim}\log\;0.9981$ and $\log\;0.8712{\sim}\log\;1.0556$, respectively. These values were within the acceptable bioequivalence intervals of $\log\;0.80{\sim}\log\;1.25$, recommended by KFDA. In all of these results, we concluded that $Lesacin^{TM}$ tablet was bioequivalent to Jeil $Cravit^{TM}$ tablet, in terms of rate and extent of absorption.

Simultaneous determination of preservatives in sausages using liquid chromatography with electrospray ionization tandem mass spectrometry (LC-MS/MS를 이용한 소시지 중 보존료 동시분석)

  • Koh, Ba-Ra-Da;Kim, Ji-Yeon;Jang, Mi-Sun;Seo, Doo-Ri;Jung, Bo-Ram;Shin, Ji-Hyun;Lim, Jin-Taek;Kim, Yong-Hwan;Kim, Eun-Sun
    • Korean Journal of Veterinary Service
    • /
    • v.38 no.2
    • /
    • pp.127-136
    • /
    • 2015
  • A simultaneous determination method was developed for nine preservatives (benzoic acid, sorbic acid, dehydroacetic acid, methyl-, ethyl-, isopropyl-, propyl-, isobutyl- and butyl-parabens) in sausage by liquid chromatography with electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS). Each parameter was established by multiple reaction monitoring in negative mode. Separation was achieved on a phenyl-hexyl ($2.5{\mu}m$, $2.1{\times}150mm$, Waters) with A-20 mM ammonium acetate containing 0.1% acetic acid in water, B-Acetonitrile as mobile phase with gradient mode at a flow rate of 0.3 mL/min. The developed method was validated for specificity, linearity, accuracy and precision in sausages samples. Linearity was over 0.998 with calibration curve of the mixed standards. The mean recoveries from sausages fortified at the level of 2.0~10.0 mg/L were in range of 98.60~109.16% with RSDs lower than 8.93%. The limits of detection (LOD) and the limits of quantification (LOQ) were in the range between 0.0003~0.085 mg/L and 0.01~0.257 mg/L, respectively. Intra-day precision and inter-day precision were 0.45~6.16% and 2.81~13.33%, respectively. Using presently developed determination method, 33 field sausage samples from Gwangju city in Korea were screened over nine preservatives. As a result, no preservatives were detected in all samples.

Six Sigma Analysis of Vitamin D Measurement Using External Quality Assessment Program (외부정도관리 프로그램을 이용한 비타민 D 검사의 6 시그마 분석)

  • Ji, Myungsuk
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.52 no.2
    • /
    • pp.91-97
    • /
    • 2020
  • Standardization of vitamin analysis continues around the world, and much effort has been made to improve the accuracy of the results. This study analyzed the sigma metrics of the vitamin D test using the external quality assessment (EQA) program. Sigma metrics is used for quantitative tests performed in the laboratory, and the test results can be objectively visualized in terms of quality. This analysis was performed based on the accuracy of the College of American Pathologists (CAP) using the results of the 2019 accuracy-based vitamin D (ABVD) survey, and about 300 laboratories participated in the survey. Reference values were obtained by the Center for Disease Control and Prevention (CDC) reference laboratory. At six different concentrations, the sigma metrics were analyzed to be 1.00, 1.85, 2.42, 1.01, 1.54 and 0.78, respectively. An average of 1.43 sigma metrics was determined. In particular, only positive biases for ABVD-16 and 17 were shown in the liquid chromatography tandem-mass spectrometry (LC-MS/MS), which is the standard method for vitamin D determination when compared to the reference values. The causes of the difference can be explained by cross reactivity to various vitamin D metabolites. Laboratories need to improve their overall performance.

Monitoring of Veterinary Antibiotics in Agricultural Soils using Liquid Chromatography Coupled with Tandem Mass Spectrometry (LC-MS/MS를 이용한 농경지 토양 중 항생제 모니터링)

  • Lee, Young-Jun;Choi, Jeong-Heui;Chung, Hyung Suk;Lee, Han Sol;Park, Byung-Jun;Kim, Jang-Eok;Shim, Jae-Han
    • Korean Journal of Environmental Agriculture
    • /
    • v.35 no.3
    • /
    • pp.166-174
    • /
    • 2016
  • BACKGROUND: The current study developed a monitoring method of 6 veterinary antibiotics (amoxicillin, ampicillin, enrofloxacin, tetracycline, chlortetracycline, oxytetracycline) in agricultural soils using liquid chromatography-tandem mass spectrometry (LC-MS/MS) in positive electrospray ionization mode.METHODS AND RESULTS: Sample preparation was carried out using acidic acetonitrile and citrate salts followed by purification with dispersive solid phase extraction (d-SPE). Separation on Eclipse Plus C18 column was conducted in gradient of the mobile phase, 0.1% formic acid and 5 mM ammonium formate in methanol (A) and 0.1% formic acid and 5 mM ammonium formate in distilled water (B). The linearity of the matrix-matched calibrations expressed as the coefficient of determination was good with R2≥0.9900. The limit of quantifications (LOQs) ranged from 0.5 to 10 μg/kg for all analytes. Analysis of 51 agricultural soil samples taken in the Republic of Korea revealed concentrations less than 1.9 μg/kg for enrofloxacin, 75.5 μg/kg for chlortetracycline.CONCLUSION: The method was successfully applied to monitor 6 veterinary antibiotics from 51 field incurred agricultural soil samples in 17 provincial areas throughout the Republic of Korea. The developed method was simple, easy, and versatile and can be used for monitoring various veterinary antibiotics in soil.

The development and validation of a novel liquid chromatography tandem mass spectrometry (LC-MS/MS) procedure for the determination of fluoroquinolones residues in chicken muscle using modified QuEChERS (quick, easy, cheap, effective, rugged and safe) method

  • Park, Sunjin;Kim, Hyobi;Choi, Byungkook;Hong, Chung-Oui;Lee, Seon-Young;Jeon, Inhae;Lee, Su-Young;Kwak, Pilhee;Park, Sung-Won;Kim, Yong-Sang;Lee, Kwang-jick
    • Korean Journal of Veterinary Service
    • /
    • v.42 no.4
    • /
    • pp.289-296
    • /
    • 2019
  • A novel rapid procedure with liquid chromatography tandem mass spectrometry (LC-MS/MS) detection has been developed by changing various conditions including sample preparation such as QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) methodology. This work has been involved the optimization and validation of detection method for fluoroquinolones which are widespread used in livestock especially in the chicken. Five grams of homogenized chicken muscle were extracted with QuEChERS EN and acetonitrile containing 5% formic acid and cleaned with anhydrous magnesium sulfate and C18 sorbent. The separation was performed on Acquity UPLC HSS T3 (2.1 mm×100 mm, 1.8 ㎛) column. The mobile phase A and B were composed of water containing 0.1% formic acid and acetonitrile containing 0.1% formic acid, respectively. Flow rate was 0.25 mL/min and column temperate was 40℃. LC-MS/MS with multiple reaction monitoring has been optimized for ten fluoroquinolones (ciprofloxacin, danofloxacin, difloxacin, enrofloxacin, marbofloxacin, norfloxacin, ofloxacin, orbifloxacin, pefloxacin and sarafloxacin). The method developed in this study has been presented good linearity with correlation coefficient (R2) of 0.9971~0.9998. LOD and LOQ values ranged from 0.09 to 0.76 ppb and from 0.26 to 2.29 ppb, respectively. The average recoveries were from 77.46 to 111.83% at spiked levels of 10.0 and 20.0 ㎍/kg. Relative standard deviation (%) ranged 1.28~11.90% on intra-day and 3.10~8.38 % on inter-day, respectively. This analysis method was applicable to the livestock residue laboratories and was expected to be satisfactory for the residue surveillance system.

Uncertainty evaluation for the determination of creatinine in urine by LC-MS/MS (LC-MS/MS를 이용한 소변 중 크레아티닌 분석의 측정불확도 평가)

  • Kim, Jin-Young;Kwon, Woon-Yong;Suh, Sung-Ill;In, Moon-Kyo
    • Analytical Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.83-90
    • /
    • 2012
  • The objective of the study was to estimate the measurement uncertainty associated with determination of creatinine (Cr) in urine samples by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Centrifuged urine samples (10 ${\mu}L$) were diluted with 390 ${\mu}L$ of distilled water. To 20 ${\mu}L$ aliquots of diluted urine samples, 30 ${\mu}L$ of internal standard solution (Cr-$d_3$, 5 ${\mu}g/mL$) and 10 ${\mu}L$ of acetonitrile were added and filtered. The samples (1 ${\mu}L$) were introduced into LC-MS/MS with no further pretreatment. Cr was separated on a multi-mode ODS column (Scherzo SM-C18, 75 ${\times}$ 2.0 mm I.D., 3 ${\mu}m$) and quantified by LC-MS/MS operating in MRM mode (Cr, m/z 114.0${\rightarrow}$ 86.0; Cr-$d_3$, m/z 117.0${\rightarrow}$ 89.1). The four factors that contribute uncertainty to the final result were extracted and evaluated. The principal factors of contribution to combined standard uncertainty were sample dilution, calibration curve and repeatability, while the preparation of standard solution was only a minor factor. Relative extended uncertainty of the measured concentration was 14.2% in a real urine sample.

Biological Monitoring of Workers Exposed to Diisocyanates using Urinary Diamines (소변 중 디아민을 이용한 디이소시아네이트 노출 근로자의 생물학적 모니터링)

  • Lee, Jong Seong;Kim, Boowook;Shin, Jungah;Baek, JinEe;Shin, Jae Hoon;Kim, Ji-hye
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.2
    • /
    • pp.178-187
    • /
    • 2016
  • Objectives: Diisocyanates are a potent inducer of diseases of the airways, especially asthma. In this study, toluenediamine(TDA) and methylenedianiline(MDA) in urine were evaluated as biomarkers of exposure to tolunenediisocyanate(TDI) and methylenediphenyl diisocyanate(MDI), respectively. Methods: Workers exposed to TDI and MDI, as well as non-occupationally exposed subjects, were studied and pre- and post-shift urine samples were collected from 8 control subjects and 8 workers from a factory which manufactures polyurethane products for reducing noise and vibration in automobiles. Airborne TDI and MDI(n=8) were sampled on solvent-free glass filters impregnated with n-butylamine and detected by liquid chromatography atmospheric pressure ionization tandem mass spectrometry. Urinary TDA and MDA were detected as pentafluoropropionic acid anhydride(PFPA) derivatives by liquid chromatography electrospray ionization tandem mass spectrometry. Results: The median levels of urinary 2,6-TDA(p<0.001), 2,4-TDA(p=0.001), and MDA(p<0.001) of workers in post-shift samples were significantly higher than those of controls. The median levels of urinary 2,6-0TDA($0.63{\mu}g/g$ creatinine vs $0.34{\mu}g/g$ creatinine, p=0.017) and MDA($4.21{\mu}g/g$ creatinine vs $3.18{\mu}g/g$ creatinine, p=0.017) of workers in post-shift samples were significantly higher than those of the pre-shift samples. There were significant correlations between the urinary 2,6-TDA, 2,4-TDA, and MDA of workers in post-shift samples and the airborne 2,6-TDI(rho=0.952, p<0.001), 2,4-TDI(rho=0.833, p=0.001), and MDI(rho=0.952, p<0.001). Conclusions: These urinary diamines, metabolites of diisocyanates, in post-shift samples were useful biomarkers to assess occupational exposure to diisocyanates.

Bioequivalence of Samchundang Lercanidipine Tablet 10 mg to Zanidip Tablet (Lercanidipine Hydrochloride 10 mg) by Liquid Chromatography with Tandem Mass Spectrometry

  • Kim, Se-Mi;Kim, Hwan-Ho;Shin, Sae-Byeok;Kang, Hyun-Ah;Cho, Hea-Young;Kim, Yoon-Gyoon;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.37 no.5
    • /
    • pp.315-321
    • /
    • 2007
  • The purpose of the present study was to evaluate the bioequivalence of two lercanidipine hydrochloride tablets, Zanidip tablet (LG Life Sciences Ltd., Korea, reference drug) and Samchundang Lercanidipine tablet 10 mg (Sam Chun Dang Pharm. Co. Ltd., Korea, test drug), according to the guidelines of Korea Food and Drug Administration (KFDA). After adding an internal standard (amlodipine maleate) to human serum, serum samples were extracted using hexan-isoamyl alcohol (100:1, v/v). Compounds were analyzed by liquid chromatography/tandem mass spectrometry. This method showed linear response over the concentration range of 0.05-20 ng/mL with correlation coefficient of 0.9999. The lower limit of quantitation using 0.5 mL of serum was 0.05 ng/mL which was sensitive enough for pharmacokinetic studies. Thirty healthy male Korean volunteers received each medicine at the lercanidipine hydrochloride dose of 20 mg in a $2\;{\times}\;2$ crossover study. There was a one-week washout period between the doses. Serum concentrations of lercanidipine were monitored by an LC/MS/MS fer over a period of 24 hr after the administration. $AUC_t$ (the area under the serum concentration-time curve from time 0 to 24 hr) was calculated by the linear trapezoidal rule method. $C_{max}$ (the maximum serum drug concentration) and $T_{max}$ (the time to reach $C_{max}$) were compiled from the serum concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_t$ and $C_{max}$. No significant sequence effect was found for all of the bioavailability parameters, indicating that the crossover design was properly performed. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{max}$ ratio for Samchundang Lercanidipine/Zanidip were log 0.9505-log 1.2258 and log 0.9987-log 1.2013, respectively. These values were within the acceptable bioequivalence intervals of log 0.80-log 1.25. Thus, the criteria of the KFDA guidelines for the bioequivalence was satisfied, indicating Samchundang Lercanidipine tablet 10 mg and Zanidip tablet are bioequivalent.

Development of the Analytical Method for Diazepam in Fishery Products using Liquid and Gas Chromatography-tandem Mass Spectrometry (LC-MS/MS 및 GC-MS/MS를 활용한 수산물 중 디아제팜의 정량분석법 개발)

  • Shin, Dasom;Kang, Hui-Seung;Kim, Joohye;Jeong, Jiyoon;Rhee, Gyu-Seek
    • Journal of Food Hygiene and Safety
    • /
    • v.33 no.2
    • /
    • pp.110-117
    • /
    • 2018
  • The aim of this study was to develop an analytical method for the quantification of diazepam residues in fishery products, using liquid and gas chromatography-tandem mass spectrometry (LC-MS/MS and GC-MS/MS). The sample utilized in the study was extracted from the fish sample (crucian carp) using 0.1% formic acid in acetonitrile. For the utilization of the purification process, the dispersive solid phase extraction (dSPE) was used for LC-MS/MS, dSPE and SPE was used for GC-MS/MS, respectively. To be sure, the standard calibration curves showed a good linearity as the noted correlation coefficients, $r^2$ was > 0.99. The average recoveries for accuracy ranged in 99.8~124% for the samples which were fortified at three different levels (0.001, 0.002 and 0.010 mg/kg). The correlation coefficient for the precision effect was measured at a range of 4.01~11.8%. The limit of detection (LOD) for the diazepam analysis was 0.0004 mg/kg, and the limit of the quantification (LOQ) was 0.001 mg/kg. The proposed analytical method was characterized with a high accuracy and acceptable sensitivity to meet the established Codex Alimentarius Commission (CAC/GL71-2009) guideline requirements. We therefore established the optimal analysis method for the determination of diazepam in the fishery products using LC-MS/MS and GC-MS/MS. It would be applicable to analyze the diazepam residues in fishery products in further studies on this subject.

Determination of Nitrovin in Fishery Products by Liquid Chromatography-tandem Mass Spectrometry (LC-MS/MS를 이용한 수산물 중 니트로빈의 정량분석법 개발 및 검증)

  • Kim, Joohye;Shin, Dasom;Kang, Hui-Seung;Jeong, Jiyoon;Rhee, Gyu-Seek
    • Journal of Food Hygiene and Safety
    • /
    • v.33 no.2
    • /
    • pp.118-123
    • /
    • 2018
  • The objective of this study was to develop a sensitive method for the identification and determination of nitrovin in fishery products by using a solid-phase extraction (SPE), as performed with a liquid chromatography-tandem mass spectrometry (LC-MS/MS). The samples were extracted with a mixture of acetonitrile and water, and were then defatted with acetonitrile saturated hexane, after which further clean-up was accomplished with SPE on the hydrophilic-lipophilic balance (HLB) cartridges. The analytes were subsequently ionized in the positive mode of an electrospray ionization (ESI), and where thereby detected in a process of multiple reaction monitoring (MRM). The linearity (expressed as correlation coefficients) of the matrix calibration curves was > 0.985. The limit of the quantification for the nitrovin was measured at 0.001 mg/kg. The accuracy (expressed as average recovery) was noted between 72.1 and 122%. The precision (expressed as coefficient variation) was noted from 2.9 to 16.9%. According to the CODEX CAC/GL-71 guideline accuracy, precision, linearity, and limit of detection were determined in three matrices (which were flatfish, eel and shrimp). The proposed method was suitable for analyzing the associated nitrovin residues. This application and result can also be a factor to contribute to the non-detection drugs management in fishery products.