• Title/Summary/Keyword: Link saving

Search Result 62, Processing Time 0.041 seconds

Analysis of Joule-heat Characteristics according to the DC-link Capacitor Film Geometrics (DC-link Capacitor필름 형상에 따른 Joule-heat특성 분석)

  • Jeon, Yong Won;Kim, Young Shin;Jeon, Euy Sik
    • Journal of the Semiconductor & Display Technology
    • /
    • v.19 no.1
    • /
    • pp.42-48
    • /
    • 2020
  • As global warming accelerates, eco-friendly electric cars are being developed to reduce carbon dioxide emissions, and power conversion inverters are used to drive motors. Among inverter components, DC-link capacitor is heated by high current usage, which causes problems such as performance and life-saving of inverter. Although metal cases with good thermal performance have been used to solve this problem, it is difficult to apply them in practice due to insulation problems with other parts. In this paper, the Heat-Generation influence factor of DC-link capacitor is analyzed. Variables on heat-generation are set at 3 levels for film width, inductance, and film thickness. Box-Behnken to 13 tests using the design and minimal deviations, e.g. through the experiment three times by each level. The surface of the film k type by attaching the sensor current is measured temperature. Capacitance was set to a minimum level of 200 ㎌ and had a frequency of 16 kHz with Worst case, ambient temperature of 85℃ and a ripple current of 50 Ams was applied. The temperature at the measurement point was collected in the data logger after sampling at 1 minute intervals for 2 hours after saturation with the ambient temperature. This experiment confirmed that setup factors are correlated with heat-generation.

A Study on the data link between SCADA and DAS (한전 변전자동차시스템과 배전자동화시스템의 자료연계방안에 관한 연구)

  • Ko, Sang-Chen;Kim, Yong-Pal
    • Proceedings of the KIEE Conference
    • /
    • 1998.07g
    • /
    • pp.2393-2395
    • /
    • 1998
  • Today it is hard to imagine the operation of power network and its facilities without the control systems such as EMS/SCADA/DAS. In KEPCO, data links to the upper layer of control system (SCABA) is required to launched DAS project lately, in terms of the needs of saving cost for the data gathering facilities (RTU) in the substation that previously equipped SCADA RTU. In this Paper we researched the circumstance of the KEPCO SCADA systems for data link and present the scheme of the data link between DAS and SCADA.

  • PDF

Utility AC Frequency to High Frequency ACPower Conversion Circuit with Soft Switching PWM Strategy

  • Sugimura Hisayuki;Ahmed Nabil A.;Ahmed Tarek;Lee Hyun-Woo;Nakaoka Mutsuo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.2
    • /
    • pp.181-188
    • /
    • 2005
  • In this paper, a DC smoothing filterless soft switching pulse modulated high frequency AC power conversion circuit connected to utility. frequency AC power source is proposed for consumer induction heating hot water producer, steamer and super heated steamer. The operating principle of DC link filterless utility frequency AC-high frequency AC (HF AC) power conversion circuit defined as high frequency cycloinverter is described, which can operate under a principle of ZVS/AVT and power regulation based on alternate asymmetrical PWM in synchronization with the utility frequency single phase AC positive or negative half wave voltage. The dual mode modulation control scheme based on high frequency PWM and commercial frequency AC voltage PDM for the proposed high frequency cycloinverter are discussed to enlarge its soft switching commutation operating range for wide HF AC power regulation. This high frequency cycloinverter is developed for high frequency IH Dual Packs Heater (DPH) type boiler used in consumer and industrial fluid pipeline systems. Based on the experiment and simulation results, this high frequency cycloinverter is proved to be suitable for the consumer use IH-DPH boiler and hot water producers. The cycloinverter power regulation and power conversion efficiency characteristics are evaluated and discussed.

A Novel type of High-Frequency Transformer Linked Soft-Switching PWM DC-DC Power Converter for Large Current Applications

  • Morimoto Keiki;Ahmed Nabil A.;Lee Hyun-Woo;Nakaoka Mutsuo
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.2
    • /
    • pp.216-225
    • /
    • 2006
  • This paper presents a new circuit topology of DC busline switch and snubbing capacitor-assisted full-bridge soft-switching PWM inverter type DC-DC power converter with a high frequency link for low voltage large current applications as DC feeding systems, telecommunication power plants, automotive DC bus converters, plasma generator, electro plating plants, fuel cell interfaced power conditioner and arc welding power supplies. The proposed power converter circuit is based upon a voltage source-fed H type full-bridge high frequency PWM inverter with a high frequency transformer link. The conventional type high frequency inverter circuit is modified by adding a single power semiconductor switching device in series with DC rail and snubbing lossless capacitor in parallel with the inverter bridge legs. All the active power switches in the full-bridge inverter arms and DC busline can achieve ZVS/ZVT turn-off and ZCS turn-on commutation operation. Therefore, the total switching losses at turn-off and turn-on switching transitions of these power semiconductor devices can be reduced even in the high switching frequency bands ranging from 20 kHz to 100 kHz. The switching frequency of this DC-DC power converter using IGBT power modules is selected to be 60 kHz. It is proved experimentally by the power loss analysis that the more the switching frequency increases, the more the proposed DC-DC converter can achieve high performance, lighter in weight, lower power losses and miniaturization in size as compared to the conventional hard switching one. The principle of operation, operation modes, practical and inherent effectiveness of this novel DC-DC power converter topology is proved for a low voltage and large current DC-DC power supplies of arc welder applications in industry.

Wireless Ad-hoc Networks Using Cooperative Diversity-based Routing in Fading Channel

  • Kim, Nam-Soo;An, Beong-Ku;Kim, Do-Hyeon;Lee, Ye-Hoon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.2B
    • /
    • pp.69-75
    • /
    • 2008
  • We propose new routing scheme, Cooperative Diversity-based Routing (CDR)which utilize the cooperative space diversity for power saving and for performance enhancement of wireless ad-hoc networks. The end-to-end performance of the proposed routing, CDR, is analyzed based on the Haenggi's link model. The improved performance is compared with Multi-hop Relay Routing (MRR) by analytical methods. When the required outage probability is $1{\times}10^{-3}$ at the destination node in ad-hoc networks with 7 nodes, we noticed that each node can save power consumption by 21.5 dB in average, by using our proposed CDR compared to MRR.

Can energy optimization lead to economic and environmental waste in LPWAN architectures?

  • Rady, Mina;Georges, Jean-Philippe;Lepage, Francis
    • ETRI Journal
    • /
    • v.43 no.2
    • /
    • pp.173-183
    • /
    • 2021
  • As low-power wide-area network (LPWAN) end devices (EDs) are deployed in massive scale, their economic and environmental costs of operation are becoming too significant to ignore and too difficult to estimate. While LPWAN architectures and protocols are designed to primarily save energy, this study shows that energy saving does not necessarily lead to lower cost or environmental footprint of the network. Accordingly, a theoretical framework is proposed to estimate the operational expenditure (OpEx) and environmental footprint of LPWAN EDs. An extended constrained optimization model is provided for the ED link assignment to gateways (GWs) based on heterogeneous ED configurations and hardware specifications. Based on the models, a simulation framework is developed which demonstrates that OpEx, energy consumption, and environmental footprint can be in conflict with each other as constrained optimization objectives. We demonstrate different ways to achieve compromises in each dimension for overall improved network performance.

A Study on Activation of uTradeHub System (uTradeHub 시스템 활성화 방안에 관한 연구)

  • Lee, Sang-Ok;Lim, Cheon-Hyeok
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • v.51
    • /
    • pp.441-464
    • /
    • 2011
  • It is childhood yet in uTradeHub system practical use. According as company's necessity of cost-saving is increased according to trade terms aggravation such as uncertainty of international money market, commodities prices rise, necessity of e-trade practical use in company is increased. Use is inevitable by state that link with e-Nego and e-B/L service with related presentation e-L/C banks is not made. At the present users are doing specification only service this main point, and practical use activation through public information and marketing about service is needed situation because most of, companies which is not using service, do not know about existence availability of uTradeHub system, usage, availability. This study presented five such as early materialization of user center's link and integration, medium and small enterprises e-trade participation extension, utilization ratio raising through government's public information, e-trade cooperation business activation between the country, electronic documents standardization etc. by prompting competition about practical use of uTradeHub system.

  • PDF

Utility Interactive Inverter with High-frequency Link for Photovoltaic Power System (고주파링크 방식을 이용한 계통연계형 태양광발전시스템)

  • Jung, Y.S.;Yu, G.W.;Lee, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1050-1052
    • /
    • 2000
  • An investigation into power conditioners that interface with photovoltaic array and utilities has been completed. The rating for this investigation is residential system (3-5kW) that interface with a 220V single phase utility connection. As the result of this investigation. a 3kW high frequency PWM IGBT inverter feeding a high frequency isolation transformer with a sinusoidal current wave was selected. The output of the transformer rectified with a diode bridge rectifier four IGBT, used as 60Hz switched, reverse the polarity of the rectified current on every other half cycle of the utility voltage. Even though the high frequency link system used more power semiconductors, a net size, weight, and parts cost saving result compared to the other systems due to elimination of 60Hz transformer.

  • PDF

High-Frequency DC Link Inverter for Grid-connected PV System (계통연계형 태양광발전시스템을 위한 고주파 DC 링크 인버터)

  • Jung Young-Seok;Yu Gwon-Jong
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.46-49
    • /
    • 2001
  • An investigation into power conditioners that interface with photovoltaic array and utilities has been completed. The rating for this investigation is residential system(3-5kVA) that interface with a 220V single phase utility connection. As the result of this investigation, a 3kVA high frequency PWM IGBT inverter feeding a high frequency isolation transformer with a sinusoidal current wave was selected. The output of the transformer rectified with a diode bridge rectifier. four IGBT, used as 60Hz switched, reverse the polarity of the rectified current on every other half cycle of the utility voltage. Even though the high frequency link system used more power semiconductors, a net size, weight, and parts cost saving result compared to the other systems due to elimination of 60Hz transformer.

  • PDF

A High Frequency-Link Bidirectional DC-DC Converter for Super Capacitor-Based Automotive Auxiliary Electric Power Systems

  • Mishima, Tomokazu;Hiraki, Eiji;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • v.10 no.1
    • /
    • pp.27-33
    • /
    • 2010
  • This paper presents a bidirectional DC-DC converter suitable for low-voltage super capacitor-based electric energy storage systems. The DC-DC converter presented here consists of a full-bridge circuit and a current-fed push-pull circuit with a high frequency (HF) transformer-link. In order to reduce the device-conduction losses due to the large current of the super capacitor as well as unnecessary ringing, synchronous rectification is employed in the super capacitor-charging mode. A wide range of voltage regulation between the battery and the super capacitor can be realized by employing a Phase-Shifting (PS) Pulse Width Modulation (PWM) scheme in the full-bridge circuit for the super capacitor charging mode as well as the overlapping PWM scheme of the gate signals to the active power devices in the push-pull circuit for the super capacitor discharging mode. Essential performance of the bidirectional DC-DC converter is demonstrated with simulation and experiment results, and the practical effectiveness of the DC-DC converter is discussed.